• Title/Summary/Keyword: frequency shifts

Search Result 184, Processing Time 0.027 seconds

The Removal of Trembling Artifacts for FORMOSAT-2

  • Chang Li-Hsueh;Wu Shun-Chi;Cheng Hsin-Huei;Chen Nai-Yu
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.142-145
    • /
    • 2005
  • Since the successful launch of FORMOSAT -2 satellite by National Space Organization of Taiwan in May 2004, the Remote Sensing Instrument (RSI) on- board the FORMOSAT -2 has continuously acquired images at one panchromatic and four multi-spectral bands (http://www.nspo.org.tw). In general, the RSI performs well and receives high quality images which proved to be very useful for various applications. However, some RSI panchromatic products exhibit obvious trembling artifact that must be removed. Preliminary study reveals that the trembling artifact is caused by the instability of the spacecraft attitude. Though the magnitude of this artifact is actually less than half of a pixel, it affects the applicability of panchromatic products. A procedure removing this artifact is therefore needed for providing image products of consistent quality. Due to the nature of trembling artifact, it is impossible to describe the trembling amount by employing an analytic model. Relied only on image itself, an algorithm determining trembling amount and removing accordingly the trembling artifact is proposed. The algorithm consists of 3 stages. First, a cross-correlation based scheme is used to measure the relative shift between adjacent scan lines. Follows, the trembling amount is estimated from the measured value. For this purpose, the Fourier transform is utilized to characterize random shifts in frequency domain. An adaptive estimation method is then applied to deduce the approximate trembling amount. In the subsequent stage, image re-sampling operation is applied to restore the trembling-free product. Experimental results show that by applying the proposed algorithm, the unpleasant trembling artifact is no longer evident.

  • PDF

[ $^1H$ ] Nuclear Magnetic Resonance Study of Ferroelectric $(NH_4)_3H(SO_4)_2$

  • Choi, S.H.;Han, K.S.;Kwon, S.K.;Nam, S.K.;Choi, H.H.;Lee, Moo-Hee;Lim, Ae-Ran
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.11 no.2
    • /
    • pp.64-72
    • /
    • 2007
  • [ $^1H$ ] nuclear magnetic resonance (NMR) experiments have been performed at 30 - 300 K and 7 T to investigate dynamics of hydrogen bond network in the single crystal $(NH_4)_3H(SO_4)_2$. The two proton sites, ammonium proton and hydrogen-bond proton, are identified from the $^1H$ NMR MAS spectrum at 340 K. As temperature decreases, the $^1H$ NMR spectrum shifts to the higher frequency side with a larger linewidth. The spectrum at 65 K shows a distinctive change in line shape toward the ferroelectric transition at 63 K. The measured values of $T_1$ for ammonium and hydrogen-bond protons are similar in the whole range of temperature. $T_1$ of $^1H$ NMR shows a gradual decrease down to 120 K and starts to steeply increase below 100 K. Then $T_1$ shows abrupt decrease below 70 K with a sharp minimum at 63 K, where the ferroelectric transition occurs. This temperature dependence of spectrum and $T_1$ clearly prove that the large change in the dynamics of hydrogen bond network is associated with the ferroelectric phase transition at 63 K.

  • PDF

Design of CFD Structured Microstrip Line Bandpass Filter (CFD 구조의 마이크로스트립 라인 가변 대역통과필터 설계)

  • Yoon, Giwan;Chai, Dongkyu;Linh, Mai;Yim, Munhyuk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.8
    • /
    • pp.1292-1296
    • /
    • 2002
  • In this paper, a 3-coupled microstrip line tunable bandpass filter has been designed on the basis of a tonductoriFerroelectricfDielectric (CFD) structure. This tunable filter basically exploits the fact that the increase in the bias voltage leads to the reduction of the effective dielectric constant (eon). This reduced $\varepsilon$eff shifts the center frequency (fc) to the higher value. The characteristics of designed filter are as follows; Return loss (RL) is larger than 10 dB; Insertion loss (IL) is les.i than 3.5 dB: 3-dB bandwidth (BW) is less than 1.18 GHz fc can be tuned from 25.4 GHz to 28.8 GHz over the variation of $\varepsilon$eff, from 10 to 13. Therefore, the tunability comes up to 3.4 GHz. The dimension of the filter designed is 7.0 mm ${\times}$ 5.0 nm ${\times}$ 0.5 mm.

Relationship between Shift Work, and Sleep Problems and Fatigue Symptoms of Nurses for General Hospitals (일부 종합병원 간호사들의 교대근무와 수면문제 및 피로자각증상과의 관련성)

  • Park, Young-Nam;Yang, Hye-Kyeong;Kim, Hyunli;Cho, Young-Chae
    • Korean Journal of Occupational Health Nursing
    • /
    • v.16 no.1
    • /
    • pp.37-47
    • /
    • 2007
  • Purpose: To find out the relationship between the shift work, and disrupted sleep and consequent fatigue symptoms. Methods: The questionnaires were given to 345 nurses of 4 hospitals with over 400 beds in Daejeon. Results: The shift workers showed worse subjective quality of sleep than the daytime workers, and had significantly higher frequency of "cannot get to sleep within 30 minutes", "wake up in the middle of the night" and "wake up in the early morning". The shift workers had significantly higher scores of subjective symptoms of fatigue than the daytime workers, and the fatigue was found to be the mental type. The subjective symptoms of fatigue scores were significantly higher in the group who had "cannot get to sleep within 30 minutes", "wake up in the middle of the night" and "wake up in the early morning". Conclusion: The study results indicated that the shift workers had the higher level of subjective symptoms of physical fatigue as well as the worse quality of sleep than the daytime workers. It is speculated that the factors attributable to the poor quality of sleep or sleep induction disorders of nurses of hospitals could be due in major part to adaptational difficulties resulting from frequent night shifts.

  • PDF

Aeroacoustic Characteristics and Noise Reduction of a Centrifugal Fan for a Vacuum Cleaner

  • Jeon, Wan-Ho;Rew, Ho-Seon;Kim, Chang-Joon
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.185-192
    • /
    • 2004
  • The aeroacoustic characteristics of a centrifugal fan for a vacuum cleaner and its noise reduction method are studied in this paper. The major noise source of a vacuum cleaner is the centrifugal fan. The impeller of the fan rotates at over 30000 rpm, and generates very high-level noise. It was revealed that the dominant noise source is the aerodynamic interaction between the rotating impeller and stationary diffuser. The directivity of acoustic pressure showed that most of the noise propagates backward direction of the fan-motor assembly. In order to reduce the high tonal sound generated from the aerodynamic interaction, unevenly pitched impeller and diffuser, and tapered impeller designs were proposed and experiments were performed. Uneven pitch design of the impeller changes the sound quality while the overall sound power level (SPL) and the performance remains similar. The effect of the tapered design of impeller was evaluated. The trailing edge of the tapered fan is inclined. This reduces the flow interaction between the rotating impeller and the stationary diffuser because of some phase shifts. The static efficiency of the new impeller design is slightly lower than the previous design. However, the overall SPL is reduced by about 4 dB(A). The SPL of the fundamental blade passing frequency (BPF) is reduced by about 6 dB (A) and the 2$\^$nd/ BPF is reduced about 20 dB (A). The vacuum cleaner with the tapered impeller design produces lower noise level than the previous one, and the strong tonal sound was dramatically reduced.

On the Fabricability of Planar Integrable Optical Band-pass Filters with Phase-shifted Gratings (집적형 ${\lambda}/4$ 위상 천이 회절격자 필터의 제작성 연구)

  • Kim, Sang-Bae
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.6
    • /
    • pp.52-60
    • /
    • 1999
  • Fabricability of phase shifted grating filters has been theoretically studied by an effective index transfer matrix method. In the optical band-pass filter with multiple ${\lambda}/4$ phase-shifts, the phase-shift error and random variation of the grating period should be suppressed such that corresponding resonance frequency lies within, the filter pass-band. The tolerance for the relative error is less than $10^3$, and is quite stringent in typical filters for WDM application. End facet reflection produces ripple in the transmission spectra and the reflectivity should be less than 1% in order to keep the ripple less than 0.25dB. Also, the effect of waveguide absorption loss is enhanced by the resonance in the filter, and the absorption should be limited to 1dB/cm for the signal loss of less than 0.2dB.

  • PDF

A New Driving Method for High Resolution AC PDP (고해상도 AC PDP를 위한 새로운 구동방식)

  • Cho, Young-Wan;Kwon, Oh-Kyong
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.38 no.4
    • /
    • pp.45-53
    • /
    • 2001
  • We have proposed a new driving method of AC PDP for both high resolution over HDTV and high luminance. The new driving method can reduce data and scan pulse width to 0.85${\mu}s$ by utilizing both rising and falling edges of sustain pulse and can provide high resolution AC PDP with high luminance by increasing the number of addressing discharge using sustain pulses with phase shifts. As a result, the proposed driving scheme makes it possible to drive 2080 horizontal resolution panel with high luminance. The experimental results using 4-inch color AC PDP with $30{\times}58$ pixels indicate that the luminance can achieved up to 850 $cd/m^2$ without image noise when we employ the four phase shifted sustain pulses with the amplitude of 140V and the frequency of 125KHz.

  • PDF

A Study on Aircraft Sensitivity Analysis for C.G Variation of Longitudinal Axis (항공기 세로축 무게중심의 변화에 따른 민감도 해석에 관한 연구)

  • 김종섭
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.6
    • /
    • pp.83-91
    • /
    • 2006
  • An advanced method of Relaxed Static Stability (RSS) is utilized for improving the aerodynamic performance of modern version supersonic jet fighter aircraft. The flight control system utilizes RSS criteria in longitudinal axis to achieve performance enhancements and improve stability. The flight control law of T-50 advanced trainer employs RSS concept in order to improve the aerodynamic performance and guarantee aircraft stability. The longitudinal center of gravity(X-c.g) varies as a function of external stores, fuel state and gear position. Shifts in X-c.g relate directly to longitudinal static margin in aircraft stability. This paper deals the maximum aft X-c.g for critical aircraft loadings and checks static margin limits using sensitivity such as damping, natural frequency, gain and phase margin. And nonlinear analysis was conducted for such as short period input. And also, this paper shows the T-50 aircraft stability based on the result of high angle of attack flight such as upright and inverted departure.

The Association between Perceived Job Performance of Hospital Coordinators and the Satisfaction of Medical Workers (의료기관 종사자가 인지한 병원코디네이터의 업무수행도와 종사자의 직무만족도와의 관련성)

  • Seo, Eun Kyung;Han, Mi Ah;Park, Jong;Ryu, So Yeon;Choi, Seong Woo;Kim, Hae-Ran
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.3
    • /
    • pp.221-230
    • /
    • 2017
  • Objectives: This study was conducted to investigate general characteristics, job characteristics, characteristics of hospitals, and hospital coordinators, and to investigate the factors affecting the job satisfaction of medical workers. Methods: The data was collected through a self-reported questionnaire among 435 workers in plastic surgery and dermatology clinics in metropolitan city G. We investigated general characteristics, job-related characteristics, characteristics of medical institutions and hospital coordinators, job performance of hospital coordinators, and job satisfaction of medical workers. T-tests, ANOVA, correlation, and multiple regression analyses were conducted to investigate the factors related with job satisfaction. Results: The job satisfaction of the medical workers and the perceived job performance of hospital coordinators were $3.55{\pm}0.40$ and $3.74{\pm}0.43$, respectively. In multiple regression analysis, drinking frequency, number of night shifts, number of work days, and hospital coordinator introduction years were associated with the job satisfaction of medical workers. The more the overall job performance of hospital coordinators increased, the higher was job satisfaction(B=0.458, p<0.001). In detail, the more job roles(B=0.218, p<0.001), core competency(B=0.145, p=0.005), and leadership(B=0.099, p=0.037) increased, the higher was the job satisfaction of medical workers. Conclusions: The job satisfaction of the medical institution workers was associated with the perceived job performance of the hospital coordinator. In order to increase the job satisfaction of medical institution workers, a hospital coordinator with specialized job performance will be able to improve job satisfaction by carrying out efficient work in the medical institution.

Monitoring the failure mechanisms of a reinforced concrete beam strengthened by textile reinforced cement using acoustic emission and digital image correlation

  • Aggelis, Dimitrios G.;Verbruggen, Svetlana;Tsangouri, Eleni;Tysmans, Tine;Van Hemelrijck, Danny
    • Smart Structures and Systems
    • /
    • v.17 no.1
    • /
    • pp.91-105
    • /
    • 2016
  • One of the most commonly used techniques to strengthen steel reinforced concrete structures is the application of externally bonded patches in the form of carbon fiber reinforced polymers (CFRP) or recently, textile reinforced cements (TRC). These external patches undertake the tensile stress of bending constraining concrete cracking. Development of full-field inspection methodologies for fracture monitoring are important since the reinforcing layers are not transparent, hindering visual observation of the material condition underneath. In the present study acoustic emission (AE) and digital image correlation (DIC) are applied during four-point bending tests of large beams to follow the damage accumulation. AE helps to determine the onset of fracture as well as the different damage mechanisms through the registered shifts in AE rate, location of active sources and change in waveform parameters. The effect of wave propagation distance, which in large components and in-situ can well mask the original information as emitted by the fracture incidents is also discussed. Simultaneously, crucial information is supplied by DIC concerning the moments of stress release of the patches due to debonding, benchmarking the trends monitored by AE. From the point of view of mechanics, conclusions on the reinforcing contribution of the different repair methodologies are also drawn.