• Title/Summary/Keyword: frequency rate

Search Result 6,604, Processing Time 0.035 seconds

A Preliminary Study on the Prediction of School Facilities Repair Frequency and Rate (학교시설 수선주기 및 수선율 예측에 관한 기초적 연구)

  • Jung, Young-Han;Lee, Jae-Sung;Cho, Bong-Ho
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.9 no.2
    • /
    • pp.1-8
    • /
    • 2010
  • This study is to present an engineering solution for the repair frequency and repair rates of a building. The existing data for the repair frequency and repair rates are used to draw the probability distribution for the generalized repair frequency and repair rate in a building. The suggested methodology can be widely used for most buildings to estimate the legal repair frequency and repair rates. Also, the methodology can be applied to resolve the risks on the maintenance costs in LC (Life Cycle) plans or LCC (Life Cycle Cost) analysis. As the future studies, there are the multiple regression analysis including the parameters on incurred costs and the decision methods on efficient repair and replacement.

Comparison of Fragility Using Natural Frequency and Damping Parameter in System (고유주파수와 감쇠비에 대한 시스템 손상도 비교)

  • Lee, Seok-Min;Jung, Beom-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.48-55
    • /
    • 2018
  • The purpose of the present study is to compare the reduction rate of natural frequency and the increase rate of damping parameter with structural damage in system. For this purpose, experiment and numerical simulation analysis are performed for the 2-span H-Beam with lower natural frequency and higher damping parameter from free vibration in structure. The response signal by impact load before and after damage is analyzed at 14 locations. The response signals for all locations are performed fast fourier transform to estimate the natural frequency reduction rate and wavelet transform to estimate the damping parameter increase rate. The time domain function corresponding to each scale(frequency) is separated from the response signal by wavelet parameter. The estimation of damping parameter increase rate using wavelet transform is more sensitive than the estimation of natural frequency reduction rate in structure.

Fatigue Crack Growth Behavior of Austenite Stainless Steel in PWR Water Conditions (모사원전환경에서 오스테나이트 스테인리스강의 피로균열성장 평가)

  • Min, Ki-Deuk;Lee, Bong-Sang;Kim, Seon-Jin
    • Korean Journal of Materials Research
    • /
    • v.25 no.4
    • /
    • pp.183-190
    • /
    • 2015
  • Fatigue crack growth rate tests were conducted as a function of temperature, dissolved hydrogen (DH) level, and frequency in a simulated PWR environment. Fatigue crack growth rates increased slightly with increasing temperature in air. However, the fatigue crack growth rate did not change with increasing temperature in PWR water conditions. The DH levels did not affect the measured crack growth rate under the given test conditions. At $316^{\circ}C$, oxides were observed on the fatigue crack surface, where the size of the oxide particles was about $0.2{\mu}m$ at 5 ppb. Fatigue crack growth rate increased slightly with decreasing frequency within the frequency range of 0.1 Hz and 10 Hz in PWR water conditions; however, crack growth rate increased considerably at 0.01 Hz. The decrease of the fatigue crack growth rate in PWR water condition is attributed to crack closure resulting from the formation of oxides near the crack tips at a rather fast loading frequency of 10 Hz.

Speed Control of DC Motor for Roller Type Seeder (롤러형 파종기 구동용 직류모터의 회전속도 제어)

  • 이중용;김유용;박상래
    • Journal of Biosystems Engineering
    • /
    • v.25 no.5
    • /
    • pp.351-358
    • /
    • 2000
  • This study was conducted to develop a speed control system of a DC motor which drove a barley seeder mounted on a combine harvester. Barley seeder mounted on a combine has been known to reduce labor and cost of barley cultivation. However, development of the seeder has been unsuccessful because the combine, a dedicated rice and barley harvester has not enough space and proper power take-off for barley seeder. To develop a barley seeder, small powered motor speed controller was required. A proximity sensor for detecting working speed of the combine and a programmable one board microprocessor was used to develope a control system. Motor parameters and motor constant, relationship between seeding rate, motor speed, groove volumes of a tested roller, torque were measured. The proximity sensor sent a frequency signal to the microprocessor. In laboratory experiments, the excitation voltage of the motor was shown not to be proportional to the size of pulse width (duty ratio). A table transforming frequency signal, that represented for working speed to proper pulse width was developed from seeding rate experiments. However, seeding rate at low frequency signal was not proportional to the working speed. Seeding rate control proportional to the frequency signal was achieved by shifting of the frequency signal.

  • PDF

Carbon Composite Material Using Nickel Nano-Powder Impregnation Research on Electromagnetic Shielding Effect (니켈나노파우더 함침기법을 이용한 탄소복합소재의 전자파차폐 효과에 관한 연구)

  • Seo, Kwang-Su;Kwac, Lee-Ku
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.12
    • /
    • pp.49-55
    • /
    • 2020
  • In order to improve the electromagnetic shielding rate of Carbon Fiber (CF), it was produced using the nickel nano-powder impregnating method. Using two types of nickel powder having thicknesses of 50 ㎛ and 100 ㎛, and a thermoplastic elastomer resin, a compound containing 10-20% nickel content was mixed and then manufactured through an extruder. The CF coated with the compound was woven and manufactured using a 1-ply specimen. The final nickel content of the specimen was verified using TGA and the distribution of nickel powder on the CF surface was verified using SEM. The metal shows a high shielding rate in the low-frequency band, but the shielding rate decreases at higher-frequency bands. The CF improves at the higher frequency band, and metals reflect electromagnetic waves while carbon absorbs electromagnetic waves. The study of shielding materials, which are stronger and lighter than metal, by using CF lighter than metal and enabling the shielding rate from low-frequency band to high-frequency band, confirmed that the larger the area coated with nickel nano-powder, the better the electromagnetic shielding performance. In particular, CF coated with a thickness of 100 ㎛ has a shielding rate similar to that of copper and can also be used for EV/HEV automotive cables and other applications in the future.

A Study on Post Occupancy Evaluation about the Community Facilities of a Rental Apartment - Focus on the 4 Apartment Built in Pangyo after 2009 - (임대 아파트 내 커뮤니티시설의 거주 후 평가에 대한 연구 - 2009년 이후 신축된 판교 4개 아파트를 중심으로 -)

  • Kim, Min-Gyu
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.2
    • /
    • pp.59-66
    • /
    • 2018
  • The purpose of this study is to investigate the method on improving the frequency of use and satisfaction rate of the community facilities and to evaluate relation between improving the frequency of use and satisfaction rate of the community facilities and improving the sense of community in apartments. The research subjects of this study is the four public lease apartments which is built around same period with same design guide. The survey method is a questionnaire survey, a experimental study, focus group interview, an analysing drawing. The result of study is as follows. The first, the frequency of use and satisfaction rate have been effected by the operation management system as well as the physical circumstance. The second, The frequency of use and satisfaction rate of the community facilities have had positive correlation with sense of community. The third, multimedia room and conference room with low usability need to change a multipurpose space such as cafe, classroom for learning on artistic topic with high demand from occupant. Finally, a mindset shift is required for architects to inspire community facilities as an important mediated space improving the sense of community by suggesting spaces for leisure and hobby activities.

UWB Communication and Ranging System using Frequency Slope Modulated Chirp (주파수 효율 및 성능 향상을 위한 Frequency Slope Modulated Chirp 신호를 이용한 UWB 시스템)

  • Kim, Jung-Hyun;Kim, Ji-Hyun;You, Cheol-woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.2A
    • /
    • pp.127-132
    • /
    • 2011
  • This paper proposes a ranging and communicating system that uses the UWB frequency slope modulated chirp signal. Instead of using only the up-chirp and down-chirp with the same frequency sweeping rate, the proposed system uses several chirps that have different frequency sweeping rates with frequency hopping. This system performs better than the conventional communication and ranging schemes because it is capable of increasing the data transmission rate and at the same time decreasing the interference between sequences used by users. In this paper, we propose simulations of UWB communication system to show validity by using the MATLAB.

A Study on Long-time Electrical Treeing Deterioration Properties According to High Frequency Voltage of Epoxy Resin (에폭시수지의 고전압 전원주파수 변화에 따른 장시간 전기적 트리잉 열화 특성연구)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.11
    • /
    • pp.1571-1577
    • /
    • 2013
  • Electrical tree structure is one of the most important influencing factors for electrical treeing characteristics in polymers. In this paper, we focused on the structure characteristics of electrical treeing in epoxy resins (original) insulation under different high-frequency voltages (60, 500, 1000Hz). Effects of voltage frequency on the ac electrical treeing phenomena in an epoxy resins were carried out in needle-plate electrode arrangement. To measure the treeing initiation and propagation, and the breakdown rate, constant AC of 10 kV with three different voltage frequencies (60, 500 and 1,000 Hz) was applied to the specimen in needle-plate electrode specimen at $30^{\circ}C$ of insulating oil bath. At 60 Hz, the treeing initiation time was 360 min and the propagation rate was $6.85{\times}10^{-4}mm/min$, and the morphology was dense branch type. As the voltage frequency increased, the treeing initiation time decreased and the propagation rate increased. At 1,000 Hz, the treeing initiation time was 0 min and the propagation rate was $7.81{\times}10^{-2}mm/min$, and the morphology was dense bush type.

Mating Call Structure and Variation of the Frog Rana nigromaculata (참개구리(Rana nigromaculata)의 짝짓기 소리의 구조와 변이)

  • 박시룡;양서영
    • The Korean Journal of Ecology
    • /
    • v.20 no.6
    • /
    • pp.423-438
    • /
    • 1997
  • The structure and variation of the mating call in Rana nigromaculata was studied in a population at Da-rak, Chong-won, Chung-buk (36$\circ$ 37' latitude, 127$\circ$ 21' longitude) in Korea. The mating call consists of 3 to 8 pulse groups divided by clear silent intervals. Each pulse group is also composed of fine pulses. Temperature and body size affect the temporal and spectral characteristics of the mating call. Pulse, pulse group repetition rate and dominant frequency rise with increasing temperature, whereas pulse grouprepetition rate and dominant frequency decrease with increasing body size. A playback experiment was designed to establish the effect of a potential intruder on male calling. During the stimulus periods, resident males markedly decreased the pulse repetition rate, and icreased the rate of pulse groups, dominant frequency, and the number of call groups. This results indicate that this species responds in a graded fashion when interacting with other individuals.

  • PDF

Effect of Electric Field Frequency on the AC Electrical Treeing Phenomena in an Epoxy/Layered Silicate Nanocomposite

  • Park, Jae-Jun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.5
    • /
    • pp.278-281
    • /
    • 2013
  • The effects of electric field frequency on the AC electrical treeing phenomena in an epoxy/layered silicate (1.5 wt%) were investigated in a needle-plate electrode arrangement. A layered silicate was exfoliated in an epoxy-base resin with AC electric field apparatus. To measure the treeing initiation and propagation- and the breakdown rate, a constant alternating current (AC) of 10 kV with three different electric field frequencies (60, 500, and 1,000 Hz) was applied to the specimen in the needle-plate electrode specimen in an insulating oil bath at $130^{\circ}C$. At 60 Hz, the treeing initiation time was 12 min, the propagation rate was $0.24{\times}10^{-3}$ mm/min, and the morphology was a dense branch type. As the electric field frequency increased, the treeing initiation time decreased and the propagation rate increased. At 1,000 Hz, the treeing initiation time was 5 min, the propagation rate was $0.30{\times}10^{-3}$ mm/min, and the morphology was a dense bush type.