• Title/Summary/Keyword: frequency problem

Search Result 3,568, Processing Time 0.034 seconds

Design of Battery System for Smoothing Wind Power Variations in Power System based on Frequency Response Analysis

  • Nakajima, Kyouhei;Umemura, Atsushi;Takahashi, Rion;Tamura, Junji
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.3
    • /
    • pp.342-348
    • /
    • 2013
  • As a number of wind power generation systems have been installed in power systems in the world, frequency fluctuations due to output power variations from wind farms have become a serious problem. Battery systems have been studied for smoothing the output variations and decreasing the resulting frequency fluctuations. Among these studies, efficient design of battery systems is one of the most important subjects from a point of view of cost. This paper presents a comparative analysis of the smoothing effect between the conventional moving average method and a new method based on frequency response analysis.

A Frequency Assignment Heuristic for the Efficient Deployments of Digital TV Systems (디지털 TV로의 효율적 전환을 위한 주파수할당 근사해법 연구)

  • Paik, Chun-Hyun
    • IE interfaces
    • /
    • v.13 no.4
    • /
    • pp.694-702
    • /
    • 2000
  • For the graceful transition from the analog to digital TV systems, a systematic frequency assignment scheme must be incorporated into the transition planning procedure. In this study, we have studied the frequency assignment methodology for the efficient management of the limited spectrum resources. By applying the graph-theoretic approach, this study developed a new solution method for additional frequency assignment problem whose objective is to assign available frequencies for newly generated requirements (digital TV stations) with minimum reassignment of the preassigned frequencies to LPTV stations while meeting the interference-related constraints. The proposed algorithm can be effectively applied not only to the current digital TV introduction phase but also to the development phase with some further development. This study can be utilized as the basis for the future study on frequency assignments that aims at graceful transition from analog TV to digital TV.

  • PDF

S-Domain Equivalent System for Electromagnetic Transient Studies PART II : Frequency Dependent AC System Equivalent (전자기 과도현상 해석을 위한 S 영역 등가시스템 PART II: 주파수 의존 교류 시스템 등가)

  • Chung Hyeng-Hwan;Wang Yong-Peel
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.4
    • /
    • pp.165-171
    • /
    • 2005
  • Electromagnetic transient simulation can be used to model complex non-linearities that very difficult to represent adequately in the frequency domain. This problem is greatly reduced with the use of frequency dependent network equivalents for the linear part of the system. S-domain rational function fitting techniques for representing frequency dependent equivalents have been developed using Least Squares Fitting(LSF). However it does not suffer the implementation error that exited in this work as it ignored the instantaneous term. This paper presents the formulation for developing 2 port Frequency Dependent AC System Equivalent(FDACSE) with the instantaneous term in S-domain and illustrates its use. This 2 port FDNE have been applied to the New Zealand AC system. The electromagnetic transient package PSCAD/EMTDC is used to assess the transient response of the 2 port (FDACSE) developed with Norton Equivalent network. The study results have indicated the robustness and accuracy of 2 port FDACSE for electromagnetic transient studies.

Sliding Mode Control with Fixed Switching Frequency for Four-wire Shunt Active Filter

  • Hamoudi, Farid;Chaghi, A. Aziz;Amimeur, Hocine;Merabet, El Kheir
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.5
    • /
    • pp.647-657
    • /
    • 2011
  • The present paper proposes a sliding mode control with fixed switching frequency for three-phase three-leg voltage source inverter based four-wire shunt active power filter. The aim is to improve phase current waveform, neutral current mitigation, and reactive power compensation in electric power distribution system. The performed sliding mode for active filter current control is formulated using elementary differential geometry. The discrete control vector is deduced from the sliding surface accessibility using the Lyapunov stability. The problem of the switching frequency is addressed by considering hysteresis comparators for the switched signals generation. Through this method, a variable hysteresis band has been established as a function of the sliding mode equivalent control and a predefined switching frequency in order to keep this band constant. The proposed control has been verified with computer simulation which showed satisfactory results.

Source Localization of an Impact on a Plate using Time-Frequency Analysis (시간 주파수 분석을 이용한 충격발생 위치 추정)

  • Park, Jin-Ho;Choi, Young-Chul;Lee, Jeong-Han
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.107-111
    • /
    • 2005
  • It has been reviewed whether it would be suitable that the application of the time-frequency signal analysis techniques to estimate the location of the impact source in plate structure. The STFT(Short Time Fourier Transform), WVD(Wigner-Ville distribution) and CWT(Continuous Wavelet Transform) methods are introduced and the advantages and disadvantages of those methods are described by using a simulated signal component. The essential of the above proposed techniques is to separate the traveling waves in both time and frequency domains using the dispersion characteristics of the structural waves. These time-frequency methods are expected to be more useful than the conventional time domain analyses fer the impact localization problem on a plate type structure. Also it has been concluded that the smoothed WVD can give more reliable means than the other methodologies for the location estimation in a noisy environment.

  • PDF

An Enhancement of Image Segmentation Using Modified Watershed Algorithm

  • Kwon, Dong-Jin
    • International journal of advanced smart convergence
    • /
    • v.11 no.4
    • /
    • pp.81-87
    • /
    • 2022
  • In this paper, we propose a watershed algorithm that applies a high-frequency enhancement filter to emphasize the boundary and a local adaptive threshold to search for minimum points. The previous method causes the problem of over-segmentation, and over- segmentation appears around the boundary of the object, creating an inaccurate boundary of the region. The proposed method applies a high-frequency enhancement filter that emphasizes the high-frequency region while preserving the low-frequency region, and performs a minimum point search to consider local characteristics. When merging regions, a fixed threshold is applied. As a result of the experiment, the proposed method reduced the number of segmented regions by about 58% while preserving the boundaries of the regions compared to when high frequency emphasis filters were not used.

Design of the Extended Kalman Filter for Frequency-amplitude Tracker (확장칼만필터 주파수-진폭 추적기 설계)

  • 윤종락;노용주;전재진
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.3
    • /
    • pp.256-263
    • /
    • 2002
  • In this study, the tracking of the temporal variation of the frequency and the amplitude in the presence of additive white Gaussian noise is considered using the Extended Kalman filter (EKF. The EKF has many applications and it has been applied to the problem of tracking the time-variable frequency. However the existing EKF frequency trackers could was driven in the small time-variable amplitude or required the additional amplitude tracker in the large time-variable amplitude. In this study, the EKF frequency-amplitude tracker, which could track both frequency and amplitude simultaneously from the measured signal in the relatively large time-variable amplitude environment, is proposed for improving the performance of the time-variable frequency tracking and its performance is verified by the simulation and the experimental work.

Frequency Control of Battery Energy Storage System with a Deadband and Restoration Control in Microgrid (마이크로그리드에서의 데드 밴드와 회복 제어를 적용한 배터리 에너지저장시스템 주파수 제어)

  • Lee, Hak-Ju;Choi, Jin-Young;Choi, Jong-Chan;Won, Dong-Jun;Chae, Woo-Kyu;Park, Jung-Sung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.11
    • /
    • pp.1584-1589
    • /
    • 2012
  • The grid-interconnected microgrid can be able to operate with and without the utility microgrid to supply electricity. when the microgrid operates in grid-connected mode, the frequency of the microgrid synchronizes with the system frequency. In this case, the frequency of the microgrid has small variation which is able to change the output of distributed generation with a droop controller. Thus, the small variation of frequency can make the distributed generation generate unnecessary electricity consistently. In this paper, we propose a frequency droop control with a dead band so as to prevent the distributed generations from generating unnecessary output while in grid-interconnected mode. In addition, a distributed generation can have a restoration control to restore the frequency changed by a droop control as a rated frequency. Also, we state the problem of restoration control with a dead band, and propose its solution when the microgrid operates in stand alone mode. We simulate the proposed droop control using PSCAD/EMTDC to verify the validity of the control.

An OFDM Frequency Offset Estimation Scheme Robust to Timing Error (시간 오차에 강인한 OFDM 주파수 옵셋 추정 기법)

  • Kim Sang-Hun;Yoon Seok-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.6C
    • /
    • pp.623-628
    • /
    • 2006
  • This paper addresses the frequency offset estimation problem in the presence of the timing error for OFDM systems. When the timing error exists, the correlation value used for the frequency offset estimation could be reduced significantly due to the timing error, resulting in considerable degradation in estimation performance. In this paper, using the coherence phase bandwidth (CPB) and a threshold, a novel frequency offset estimation scheme is proposed and based on which, an efficient timing error estimation scheme is also proposed for the re-estimation of the frequency offset. The performance comparison results show that the proposed frequency offset estimation scheme is not only more robust to the timing error but also has less computational complexity, as compared with the conventional schemes. It is also demonstrated by simulation that theproposed timing error estimation scheme gives a reliable estimate of the timing error.

Ripple Free Multirate Controller Design Using Lifting Technique (리프팅 기법을 이용한 리플 제거 멀티레이트 제어기 설계)

  • Jeong, Dong-Seul;Cho, Kyu-Nam;Chung, Chung-Choo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.11
    • /
    • pp.1040-1047
    • /
    • 2007
  • This paper presents ripple-free method that can occur in multirate controller design. The conventional multirate input controller has the problem that the ripple occurs in track-following because of chattering phenomenon in control input signal. In order to resolve the problem of rippling, it was proposed to eliminate the ripple phenomenon using feedforward compensator. This paper makes explains problems in conventional ripple-tree multirate controller and introduces a multirate controller design method applying lifting technique based on current estimators in condition space. Using the ripple-tree multirate controller, we show that chattering does not occur in the control input signal through applying the final value theorem from the viewpoint of discrete-time transformation. Also, this study proves that the ripple of the proposed controller decreases with the increase of this sampling frequency and, when sampling frequency is fixed, it decreases with the increase of the control input period.