• Title/Summary/Keyword: frequency coordination

Search Result 204, Processing Time 0.026 seconds

Inter-cell Interference Coordination Method Based on Active Antenna System in Heterogeneous Networks (이종망 환경에서 능동 안테나 시스템 기반의 셀간 간섭 제어 방법)

  • Kim, Byoung-June;Park, Haesung;Kim, Duk Kyung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39A no.9
    • /
    • pp.548-556
    • /
    • 2014
  • To cope with recently increasing demand for data traffics, heterogeneous networks have been actively studied, where small cells are deployed within a macro cell coverage with the same frequency band. To mitigate the interference from the macro cell to small cells, an enhanced Inter-cell Interference Coordination (eICIC) technique has been proposed, where ABS (Almost Blank Subframe) is used in time domain. However, there is a waste of resource since no data is transmitted in a macro-cell in ABS. In this paper, we propose a new interference management method by using a 3D sector beam based on Active Antenna System (AAS), where Genetic Algorithm (GA) is applied to reduce the antenna gain toward a small-cell. With the proposed scheme, the macro-cell and small cells can transmit data at the same time with the AAS antenna pattern generating reduced interference to small cells. The performance of the proposed scheme is evaluated by using an LTE-Advanced system level simulator.

A Study on Protective Coordination Setting of Positive Offset Mho Loss of Field Relay (Positive Offset Mho 계자 상실 계전기 보호 협조 정정에 관한 연구)

  • Kim, Kwnag-Hyun;Park, Ji-Kyung;Kim, Jun-Hyeok;Kim, Doo-Ung;Kang, Sung-Bum;Kim, Chul-Hwan;Lyu, Young-Sik;Yang, Jeong-Jae;Ko, Yun-Tae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.8
    • /
    • pp.1326-1333
    • /
    • 2016
  • It is important to clear the fault and prevent resulting in damage to power system. Although the frequency of generator internal fault is relatively low, it can lead to incalculable damage to power system as well as generator. Especially, loss of field on generator can cause the generator to lose synchronism for a short time if it is not removed promptly. Therefore, it is needed to conduct research on loss of field relay for detecting or clearing the loss of field. However, the setting of the relay may vary in generator operator or engineer, and the relay is not coordinated well with other elements associated with loss of field. In this paper, we address specifically the coordination of positive offset mho loss of field relay which is one of the protection schemes for loss of field. Computer simulations are performed by using ElectroMagnetic Transients Program-Restructured Version (EMTP-RV) based on actual data.

Inter-Cell Interference Coordination Scheme for OFDM-based 4G Cellular Systems (OFDM 기반의 4G 셀룰러 시스템을 위한 인접 셀간의 간섭 조정 기법)

  • Yoon, Gil-San;Lee, Jeong-Hwan;Cho, In-Sik;Seo, Chang-Woo;You, Cheol-Woo;Hwang, In-Tae
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.46 no.8
    • /
    • pp.16-21
    • /
    • 2009
  • OFDM is a key technology for 4G cellular systems in the future. But when OFDM is used in cellular system environment, it has severe inter-cell interference problems. In this paper, we propose an ICIC scheme that can reduce inter-cell interference for OFDM-based 4G cellular systems. and we analyze the efficiency of the proposed scheme. Simulation is carried out according to the simplified 3GPP LTE system level simulation parameters. We have confirmed the improvement of Geometry efficiency about 4dB at the results.

On the Coexistence among WiMAX-TDD, TD-LTE, and TD-SCDMA

  • Cho, Bong-Youl;Kim, Jin-Young
    • Journal of electromagnetic engineering and science
    • /
    • v.10 no.3
    • /
    • pp.104-116
    • /
    • 2010
  • With several advantages such as flexible downlink-to-uplink(DL-to-UL) ratio and flexible spectrum usage, Time Division Duplexing(TDD) is emerging as an alternate to Frequency Division Duplexing(FDD), especially in wireless broadband systems. We already have at least four different TDD systems in the industry: Time Division-Synchronous Code Division Multiple Access(TD-SCDMA), IEEE 802.16e-TDD, IEEE 802.16m-TDD, and Time Division-Long Term Evolution(TD-LTE). A disadvantage of TDD is that tight coordination such as time synchronization between adjacent operators is required to prevent interference between the adjacent TDD systems. In this paper, we investigate coexistence scenarios among the above four well-known TDD systems and calculate spectral efficiency(SE) loss in each scenario. Our findings are that SE loss can be significant if TDD ratios of the adjacent operators are considerably different. However, as long as the TDD ratios of the adjacent operators are similar, configurations in the systems permit perfect time synchronization between the two heterogeneous TDD systems, and the resulting SE loss is zero or reasonably low. We believe that the above findings and the configurations of the TDD systems recommended tominimize SE loss will be helpful for operators who deploy TDD systems in system parameter determination and cross-operator coordination.

FT-Raman Studies on Ionic Interactions in ${\pi}$-Complexes of Poly(hexamethylenevinylene) with Silver Salts

  • Kim Jong-Hak;Min Byoung-Ryul;Won Jong-Ok;Kang Yong-Soo
    • Macromolecular Research
    • /
    • v.14 no.2
    • /
    • pp.199-204
    • /
    • 2006
  • Remarkably high and stable separation performance for olefin/paraffin mixtures was previously reported by facilitated olefin transport through ${\pi}$-complex membranes consisting of silver ions dissolved in poly(hexamethylenevinylene) (PHMV). In this study, the ${\pi}$-complex formation of $AgBF_4,\;AgClO_4\;and\;AgCF_{3}SO_3$ with PHMV and their ionic interactions were investigated. FT-Raman spectroscopy showed that the C=C stretching bands of PHMV shifted to a lower frequency upon incorporation of silver salt, but the degree of peak shift depended on the counter-anions of salt due to different complexation strengths. The symmetric stretching modes of anions indicated the presence of only free ions up to [C=C]:[Ag]=1:1, demonstrating the unusually high solubility of silver salt in PHMV. Above the solubility limit, the ion pairs and higher-order ionic aggregates started to form. The coordination number of silver ion for C=C of PHMV was in the order $AgBF_4$ > $AgClO_4$ > $AgCF_{3}SO_3$, but became similar at [C=C]:[Ag]=1:1. The different coordination number was interpreted in terms of the different transient crosslinks of silver cations in the complex, which may be related to both the interaction strength of the polymer/silver ion and the bulkiness of the counteranion.

Performance Analysis of Inter-cell Interference Coordination through Zone Distribution in Cell (각 셀 영역의 사용자 분포에 따른 셀간 간섭 조정 기법의 성능 분석)

  • Yoon, Gil-Sang;Seo, Chang-Woo;Hwang, In-Tae
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.3
    • /
    • pp.36-40
    • /
    • 2011
  • OFDM technology is already commonplace in the current mobile communication system environment. However, inter-cell interference causes many problems in the cellular system as seen from the problem caused by the surge in the use of smart phones. In this paper, we will research how user distribution influences a performance of a conventional proposed algorithm in the certain cell area and confirm it through computer simulations. As a result, we proved that there is an appropriate user distribution in the cell. In addition, it has an effect on the performance of inter-cell interference coordination.

Variation in IR and Raman Spectra of CD3CN upon Solvation of InCl3 in CD3CN: Distinctive Blue Shifts, Coordination Number, Donor-Acceptor Interaction, and Solvated Species

  • Cho, Jun-Sung;Cho, Han-Gook
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.4
    • /
    • pp.803-809
    • /
    • 2009
  • Notable blue shifts of the ν2 $C{\equiv}N$ stretching, $_{v4}$ C-C stretching and $_{v8}$ CCN deformation bands of $CD_3CN$ are observed upon solvation of $InCl_3$, resulting from the donor-acceptor interaction. The Raman spectrum in the $_{v2}$ region shows further details; at least two new bands emerge on the blue side of the $_{v2}$ band of free $CD_3CN$, whose relative intensities vary with concentration, suggesting that there exist at least two different cationic species in the solution. The strong hydrogen bonds formed between the methyl group and ${InCl_4}^-$ result in a large band appearing on the red side of the ν1 $CD_3$ symmetric stretching band. The solvation number of $InCl_3$, determined from the Raman intensities of the $C{\equiv}N$ stretching bands for free and coordinated $CD_3CN$, increases from $\sim$1.5 to $\sim$1.8 with decreasing concentration.

A Study on Protection of Generator Asynchronization by Impedance Relaying (임피던스 계전기를 이용한 발전기 비동기 투입 보호 연구)

  • Lee, Jong-Hweon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.11
    • /
    • pp.2000-2006
    • /
    • 2011
  • Asynchronous phenomenon occurs on the synchronous generators under power system when a generator's amplitude of electromagnetic force, phase angle, frequency and waveform etc become different from those of other synchronous generators which can follow instantly varying speed of turbine. Because the amplitude of electromagnetic force, phase frequency and waveform differ from those of other generators with which are to be put into parallel operation due to the change of excitation condition for load sharing and the sharing load change, if reactive current in the internal circuit circulates among generators, the efficiency varies and the stator winding of generators are overheated by resistance loss. Where calculation method of protection settings and Logic for Protection of Generator Asynchronization will be recommended, A distance relay scheme is commonly used for backup protection. This scheme, called a step distance protection, is comprised of 3 steps for graded zones having different operating time. As for the conventional step distance protection scheme, Zone 2 can exceed the ordinary coverage excessively in case of a transformer protection relay especially. In this case, there can be overlapped protection area from a backup protection relay and, therefore, malfunctions can occur when any fault occurs in the overlapped protection area. Distance relays and overcurrent relays are used for backup protection generally, and both relays have normally this problem, the maloperation, caused by a fault in the overlapped protection area. Corresponding to an IEEE standard, this problem can be solved with the modification of the operating time. On the other hand, in Korea, zones are modified to cope with this problem in some specific conditions. These two methods may not be obvious to handle this problem correctly because these methods, modifying the common rules, can cause another coordination problem. To overcome asynchronizing protection this paper describes an improved backup protection coordination scheme using a new Logic that will be suggested.

A Double Band Hysteresis Current Control Method (이중밴드 히스테리시스 전류 제어 방식)

  • Oh W.H.;Yoo C.H.;Shin E.C.;Park S.M.;Noh H.Y.;Yoo J.Y.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.579-583
    • /
    • 2003
  • Hysteresis controllers are intrinsically robust to system parameters, exhibit very high dynamic response and are suitable for simple implementation. But the current control using a conventional hysteresis controller has the disadvantage that high switching frequency may happen due to lack of coordination among individual hysteresis controllers of three phases. This will of course increase the switching loss. In addition, the current error is not strictly limited. So, in this paper to reduce the switching frequency, a double band hysteresis current controller is proposed. The presented control system was tested with digital simulation in the Borland C++ program and demonstrate the advantage of proposed hysteresis current controller.

  • PDF

A case Study for Protection Relay System of small Cogeneration intertie (단순병렬 자가발전 설비 보호방식 검토 사례)

  • Lee, S.J.;Kim, K.S.;Yoon, K.K.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.234-236
    • /
    • 2002
  • The Co-Gen System which maximize energy efficiency was installed at the industrial plants at the initial stage. However Small Scale Co-Gen System was expanded even to the general end-users such as housing and building owing to ESCO business recently. For this SSC, inter-connected operation to the utility is desirable due to voltage and frequency fluctuation following to unbalance between power output and load. Then voltage unbalance with utility system, frequency, increase of short circuit capacity, reclosing, and ALTS etc. should be fully considered for the inter-connected operation. Voltage variation, protection coordination, Co-Generators single running, and short circuit capacity should also be solved. To research the method and solve the problems through the field test and application, we study individual customers Co-Gen System as a case study.

  • PDF