• 제목/요약/키워드: free-vibration decay method

검색결과 15건 처리시간 0.023초

비선형 영역에서의 재료감쇠비 측정을 위한 주파수-위상각법 (Frequency-Phase Method to Measure Material Damping in a Nonlinear Range)

  • 우규석;조성호
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.533-540
    • /
    • 2001
  • Material damping is an important parameter to evaluate the site response by a dynamic loading. Currently the material damping of the subgrade is mainly determined by a resonant column testing. Typical methods to evaluate material damping include half-power bandwidth method and free-vibration decay method. In the large strain range, the half-power bandwidth method gives an erratic damping factor, because the method is based on the assumption of the linear behavior of a specimen. The free-vibration decay method has also limitations in that the damping factors vary with the range of cycles in calculation, and also in that the specific shear strain can not be designated for the free vibration. In this study, the frequency-phase method, which was developed to evaluate material damping of a beam simply supported, is introduced to evaluate the material damping by the resonant column testing. Also, the comparison among half-power method, free-vibration decay method and the frequency-phase method is provided for a remolded sand.

  • PDF

Natural frequency analysis of tractor tire with different ground contacts and inflation pressures

  • Cuong, Do Minh;Sihong, Zhu
    • Coupled systems mechanics
    • /
    • 제9권5호
    • /
    • pp.455-471
    • /
    • 2020
  • This paper presents the results of the study of vertically natural frequency of tractor tires are effected by changing different ground contacts and inflation pressures using the Free Decay Method. The results show that the natural frequencies of the tire are not affected while the vertical acceleration increased strongly due to the increase of inflation pressure when the tire performs free decay vibration on rigid ground. In addition, the number of natural frequency peaks of the tire also increases with increasing tire inflation pressure. On the other hand, the natural frequencies of the tractor tire increases strongly while the vertical acceleration decreases slightly with the increase of tire inflation pressure as the tire performs free decay vibration on soft soil. Further, the natural frequencies of tire-soil system are always higher than that of tire only, and it changed with changing the soil depth. Results also show the natural frequency of tire and tire-soil system is in the range of 3.0 to 10.0 Hz that lie within the most critical natural frequency range of the human body. These findings have to be mentioned and used as design parameters of the tractor suspension system.

측정자료를 이용한 시간영역에서의 구조물의 동특성 추정 (Time Domain Identification of Structures Using Test Data)

  • 한종석;정범석
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1996년도 가을 학술발표회 논문집
    • /
    • pp.159-167
    • /
    • 1996
  • This paper describes the theory and verification of a method which utilizes the free decay response of a structure to determine its vibration parameters. The theory of the method is base on the formulation of a system matrix, contains information characterizing the complete set of modal parameters of the system, and its eigen-solution problem. The applicability of the method is verified by simulated free decay response data of a cantilever bean The method described was used to determined the parameters related to the first five generated modes of vibration of a cantilever beam. It involves two very close natural frequencies which could not be identified using a frequency sweep test(peak amplitude) because of interference between modes.

  • PDF

시험 방법에 따른 바(Bar) 형 시편의 동특성 비교 (Study on the Test Method for Measuring Vibration Damping Properties using Bae Type Specimen)

  • 이용봉;권휴상;정성수;전병수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1939-1944
    • /
    • 2000
  • Different test methods were used to measure and compare the loss factor of a steel beam. They are free vibration logarithmic decay method, half-power bandwidth method using narrow-band analysis, wide-band analysis method with inverse FFT. In these tests, specimens are clamped at one end. Free vibration method and half-power bandwidth method gave good results. Effect of vibration pick-ups were tested. We also tried center excitation method but could not obtain loss factor.

  • PDF

Numerical simulations of two-dimensional floating breakwaters in regular waves using fixed cartesian grid

  • Jeong, Kwang-Leol;Lee, Young-Gill
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제6권2호
    • /
    • pp.206-218
    • /
    • 2014
  • The wave attenuation by floating breakwaters in high amplitude waves, which can lead to wave overtopping and breaking, is examined by numerical simulations. The governing equations, the Navier-Stokes equations and the continuity equation, are calculated in a fixed Cartesian grid system. The body boundaries are defined by the line segment connecting the points where the grid line and body surface meet. No-slip and divergence free conditions are satisfied at the body boundary cell. The nonlinear waves near the moving body is defined using the modified marker-density method. To verify the present numerical method, vortex induced vibration on an elastically mounted cylinder and free roll decay are numerically simulated and the results are compared with those reported in the literature. Using the present numerical method, the wave attenuations by three kinds of floating breakwaters are simulated numerically in a regular wave to compare the performance.

내부마찰 측정장치의 소개

  • 김재환
    • 전기의세계
    • /
    • 제32권3호
    • /
    • pp.142-149
    • /
    • 1983
  • 지금까지 알려진 내부마찰측정방법으로는 자유감쇄법(free decay method), 강제진동법(forced vibration method), 비공진강제진동법(non-resonance forced vibration method) 및 초음파법(ultrasoni method) 등이 있다. 이상의 모든 내부마찰실험방법에 관한 실험장치는 그 기계의 동작특성에 따라 실험주파수가 극히 한정되어 있어 연속적인 변화를 시킬 수 없으므로 완화효과를 연속적으로 추적하기 위하여 온도를 변화시키는 방법이 널리 사용되고 있다. 이상에서 소개한 방법들중 본인들이 국산제작실험에 성공한 바 있는 장치는 자유감쇄법에 속하는 염회진자장치(torsion pendulum device) 이므로 이 장치를 중심으로 내부마찰측정원리와 그의 장치에 관하여 소개하고저 한다.

  • PDF

The use of the semi-empirical method to establish a damping model for tire-soil system

  • Cuong, Do Minh;Ngoc, Nguyen Thi;Ran, Ma;Sihong, Zhu
    • Coupled systems mechanics
    • /
    • 제7권4호
    • /
    • pp.395-406
    • /
    • 2018
  • This paper proposes a linear damping model of tire-soil system using semi-empirical method. A test rig was designed and developed to measure the vertical equivalent linear damping ratio of tire only and tire-soil system using Free-Vibration Logarithmic Decay Method. The test was performed with two kinds of tractor tires using a combination of five inflation pressure levels, two soil depths and four soil moisture contents in the paddy soil. The results revealed that the linear damping ratio of tires increased with decreasing tire inflation pressure; the linear damping ratio of tire-soil system also increased with decreasing tire inflation pressure and increased with the increasing soil depth (observed at 80 and 120 mm). It also increased with a relative increase of soil moisture contents (observed at 37.9%, 48.8%, 66.7% and 77.4%). The results also indicated that the damping ratio of tire-soil system was higher than that of tire only. A linear damping model of tire-soil system is proposed as a damping model in parallel which is established based on experimental results and vibration theory. This model will have a great significance in study of tractor vibration.

Determining minimum analysis conditions of scale ratio change to evaluate modal damping ratio in long-span bridge

  • Oh, Seungtaek;Lee, Hoyeop;Yhim, Sung-Soon;Lee, Hak-Eun;Chun, Nakhyun
    • Smart Structures and Systems
    • /
    • 제22권1호
    • /
    • pp.41-55
    • /
    • 2018
  • Damping ratio and frequency have influence on dynamic serviceability or instability such as vortex-induced vibration and displacement amplification due to earthquake and critical flutter velocity, and it is thus important to make determination of damping ratio and frequency accurate. As bridges are getting longer, small scale model test considering similitude law must be conducted to evaluate damping ratio and frequency. Analysis conditions modified by similitude law are applied to experimental test considering different scale ratios. Generally, Nyquist frequency condition based on natural frequency modified by similitude law has been used to determine sampling rate for different scale ratios, and total time length has been determined by users arbitrarily or by considering similitude law with respect to time for different scale ratios. However, Nyquist frequency condition is not suitable for multimode system with noisy signals. In addition, there is no specified criteria for determination of total time length. Those analysis conditions severely affect accuracy of damping ratio. The focus of this study is made on the determination of minimum analysis conditions for different scale ratios. Influence of signal to noise ratio is studied according to the level of noise level. Free initial value problem is proposed to resolve the condition that is difficult to know original initial value for free vibration. Ambient and free vibration tests were used to analyze the dynamic properties of a system using data collected from tests with a two degree-of-freedom section model and performed on full bridge 3D models of cable stayed bridges. The free decay is estimated with the stochastic subspace identification method that uses displacement data to measure damping ratios under noisy conditions, and the iterative least squares method that adopts low pass filtering and fourth order central differencing. Reasonable results were yielded in numerical and experimental tests.

Structural evaluation of all-GFRP cable-stayed footbridge after 20 years of service life

  • Gorski, Piotr;Stankiewicz, Beata;Tatara, Marcin
    • Steel and Composite Structures
    • /
    • 제29권4호
    • /
    • pp.527-544
    • /
    • 2018
  • The paper presents the study on a change in modal parameters and structural stiffness of cable-stayed Fiberline Bridge made entirely of Glass Fiber Reinforced Polymer (GFRP) composite used for 20 years in the fjord area of Kolding, Denmark. Due to this specific location the bridge structure was subjected to natural aging in harsh environmental conditions. The flexural properties of the pultruded GFRP profiles acquired from the analyzed footbridge in 1997 and 2012 were determined through three-point bending tests. It was found that the Young's modulus increased by approximately 9%. Moreover, the influence of the temperature on the storage and loss modulus of GFRP material acquired from the Fiberline Bridge was studied by the dynamic mechanical analysis. The good thermal stability in potential real temperatures was found. The natural vibration frequencies and mode shapes of the bridge for its original state were evaluated through the application of the Finite Element (FE) method. The initial FE model was created using the real geometrical and material data obtained from both the design data and flexural test results performed in 1997 for the intact composite GFRP material. Full scale experimental investigations of the free-decay response under human jumping for the experimental state were carried out applying accelerometers. Seven natural frequencies, corresponding mode shapes and damping ratios were identified. The numerical and experimental results were compared. Based on the difference in the fundamental natural frequency it was again confirmed that the structural stiffness of the bridge increased by about 9% after 20 years of service life. Data collected from this study were used to validate the assumed FE model. It can be concluded that the updated FE model accurately reproduces the dynamic behavior of the bridge and can be used as a proper baseline model for the long-term monitoring to evaluate the overall structural response under service loads. The obtained results provided a relevant data for the structural health monitoring of all-GFRP bridge.

Aero-elastic wind tunnel test of a high lighting pole

  • Luo, Yaozhi;Wang, Yucheng;Xie, Jiming;Yang, Chao;Zheng, Yanfeng
    • Wind and Structures
    • /
    • 제25권1호
    • /
    • pp.1-24
    • /
    • 2017
  • This paper presents a 1:25 multi-freedom aero-elastic model for a high lighting pole at the Zhoushan stadium. To validate the similarity characteristics of the model, a free vibration test was performed before the formal test. Beat phenomenon was found and eliminated by synthesis of vibration in the X and Y directions, and the damping ratio of the model was identified by the free decay method. The dynamic characteristics of the model were examined and compared with the real structure; the similarity results were favorable. From the test results, the major along-wind dynamic response was the first vibration component. The along-wind wind vibration coefficient was calculated by the China code and Eurocode. When the peak factor equaled 3.5, the coefficient calculated by the China code was close to the experimental result while Eurocode had a slight overestimation of the coefficient. The wind vibration coefficient during typhoon flow was analyzed, and a magnification factor was suggested in typhoon-prone areas. By analyzing the power spectrum of the dynamic cross-wind base shear force, it was found that a second-order vortex-excited resonance existed. The cross-wind response in the test was smaller than Eurocode estimation. The aerodynamic damping ratio was calculated by random decrement technique and the results showed that aerodynamic damping ratios were mostly positive at the design wind speed, which means that the wind-induced galloping phenomenon is predicted not to occur at design wind speeds.