• Title/Summary/Keyword: fractures

Search Result 2,684, Processing Time 0.031 seconds

Operative Treatment of Distal Clavicle Fracture with Acromioclavicular Joint Injury (견봉 쇄골 관절의 손상을 동반한 원위 쇄골 골절의 수술적 치료)

  • Kang, Ho-Jung;Koh, Il-Hyun;Joo, Jong-Hwan;Chun, Yong-Min;Kim, Hyung-Sik
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.1
    • /
    • pp.59-66
    • /
    • 2011
  • Purpose: We wanted to evaluate the clinical and radiological outcomes and the prognosis of various surgical treatments for the distal clavicle fracture with an acromioclavicular joint injury. Materials and Methods: A retrospective study of 21 patients with a minimum of 12 months follow up was done. We classified acromioclavicular (AC) injury into type I (only intra-articular fracture (IAF), 5 cases), type II (IAF with widening of the AC joint > 7 mm, 9 cases) and type III (IAF with AC joint superior subluxation > 50%, 7 cases). The distal clavicle fractures were fixed using plate (9 cases), mini screws (1 case), K wire and tension band wiring (10 cases) and transarticular pinning (1 case). Acromioclavicular or coracoacromial ligament reconstruction was not done in all the cases. Results: In 20 of 21 cases, bone union was achieved at an average of 8.4 weeks. Traumatic arthritis (5 cases), AC joint widening (4 cases) and AC joint subluxation (2 cases) were noted at the last follow up. The average UCLA score was 32.6 in the type I AC joint injuries, 34 in type II and 34.1 in type III. There was no relationship between the clinical outcomes and the preoperative AC joint injury pattern, postoperative traumatic arthritis, AC joint widening or AC joint subluxation (p>0.05). Conclusion: Satisfactory results were achieved by acute reduction and firm fixation of the distal clavicle fracture with AC joint injury. There was no relationship between the pattern of AC joint injury, the residual radiologic findings and the functional outcome.

Application of the Homogenization Analysis to Calculation of a Permeability Coefficient (투수계수 산정을 위한 균질화 해석법의 적응)

  • 채병곤
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.1
    • /
    • pp.79-86
    • /
    • 2004
  • Hydraulic conductivity along rock fracture is mainly dependent on fracture geometries such as orientation, aperture, roughness and connectivity. Therefore, it needs to consider fracture geometries sufficiently on a fracture model for a numerical analysis to calculate permeability coefficient in a fracture. This study performed new type of numerical analysis using a homogenization analysis method to calculate permeability coefficient accurately along single fractures with several fracture models that were considered fracture geometries as much as possible. First of all, fracture roughness and aperture variation due to normal stress applied on a fracture were directly measured under a confocal laser scaning microscope (CLSM). The acquired geometric data were used as input data to construct fracture models for the homogenization analysis (HA). Using the constructed fracture models, the homogenization analysis method can compute permeability coefficient with consideration of material properties both in microscale and in macroscale. The HA is a new type of perturbation theory developed to characterize the behavior of a micro inhomogeneous material with a periodic microstructure. It calculates micro scale permeability coefficient at homogeneous microscale, and then, computes a homogenized permeability coefficient (C-permeability coefficient) at macro scale. Therefore, it is possible to analyze accurate characteristics of permeability reflected with local effect of facture geometry. Several computations of the HA were conducted to prove validity of the HA results compared with the empirical equations of permeability in the previous studies using the constructed 2-D fracture models. The model can be classified into a parallel plate model that has fracture roughness and identical aperture along a fracture. According to the computation results, the conventional C-permeability coefficients have values in the range of the same order or difference of one order from the permeability coefficients calculated by an empirical equation. It means that the HA result is valid to calculate permeability coefficient along a fracture. However, it should be noted that C-permeability coefficient is more accurate result than the preexisting equations of permeability calculation, because the HA considers permeability characteristics of locally inhomogeneous fracture geometries and material properties both in microscale and macroscale.

Change in the Measured Value at 99mTc-MDP Administration before and after Bone Density Measurement using the Dual Energy X-ray Absorptiometry (이중에너지 X선 흡수법을 이용한 골밀도 측정시 99mTc-MDP 투여 전·후 측정값의 변화)

  • Kang, Yong-Gil;Won, Do-Yeon;Jung, Hong-Moon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.43-48
    • /
    • 2017
  • Measurement of bone marrow measurements may occur if bone marrow examination performed with bone marrow examination (bone marrow examination) and bone density (bone scan) are performed together recently. Thus, it was examined in clinical aspects that $^{99m}Tc-MDP$ compounds were affected by bone mineral density measurements. The average age of the participants in the experiment was $35.17{\pm}9.45$ and the patient fractures of the lumbar vertebrae that could affect the metabolic disease and bone density measurements affecting the metabolic disease of the 17 subjects. 6 patients with normal bone mineral density T-scores>-1.0 in 12 patients were analyzed before and after the administration of $^{99m}Tc-MDP$. In the lumbar spine, the average of $0.975{\pm}0.084g/cm^2$ and $0.966{\pm}0.078g/cm^2$ were increased by $0.009g/cm^2$. respectively In the right proximal femur, mean values were $0.909{\pm}0.078g/cm^2$ and $0.913{\pm}0.086g/cm^2$. In the right proximal thigh, mean values were $0.909{\pm}0.078g/cm^2$ and $0.913{\pm}0.08 g/cm^2$, respectively, which decreased by $0.004g/cm^2$. In the left side proximal femur, mean $0.887{\pm}0.099g/cm^2$ and $0.881{\pm}0.103g/cm^2$, respectively, increased by $0.007g/cm^2$. Therefore, the BMD changes in the lumbar region were larger than that in the proximal thigh. In addition, $^{99m}Tc-MDP$ did not affect the BMD. And a bone scan test using a technetium-labeled compound emitting a gamma-ray energy of 140 keV did not significantly affect bone density measurements. However, if the nuclear medical examination and the osteoporosis test are to be performed together, the examination should be carried out at intervals considering the exposures of the patient.

Clinical Outcomes and Prognosis of Patients with Stent Fracture after Successful Drug-Eluting Stent Implantation (관상동맥 약물 방출 스텐트 삽입 후 스텐트 골절에 대한 임상결과 및 예후)

  • Kim, In-Soo;Han, Jae-Bok;Jang, Seong-Joo
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.109-116
    • /
    • 2014
  • Many studies have suggested that in the era of Drug-Eluting Stents(DES) are one of the causes of In-Stent Restenosis(ISR) of Stent Fracture(SF). The present study sought to evaluate clinical characteristics of patients with stent fracture after successful DES implantation. The 4,701 patients were selected for analysis who underwent a follow-up coronary angiography irrespective of ischemic symptoms. The overall incidence of SF was 32 patients(male:female=19:13, Av. age $62.44{\pm}9.8$year, 0.68%). Fractures of Sirolimus-Eluting Stents(SES), Paclitaxel-Eluting Stents(PES), Biolimus A9-Eluting Stents(BES), Everolimus-Eluting Etents(EES), Endothelial Progenitor Cell Capture Stent(EPC) and Zotarolimus-Eluting Stents(ZES) are accounted for 19(59.4%), 9(28.1%), 2(6.3%), 1(3.1%), 1(3.1%) and 0(0%) respectively. SF developed in the left Anterior Dscending(LAD) artery in 16 patients(50%) and in complex(type B2, C) lesions in 25 patients(69.4%). Ten patients were treated with heterogenous DES, the rest being treated with either homogenous DES(3 patients), plain old balloon angioplasty(3 patients), or conservative medical treatment(17 patients). None of the patients with SF suffered from cardiac death during a follow-up period of $32.9{\pm}12.4$ months. The overall rate of DES fracture over up to 3.7 years of follow-up was 0.68% with higher incidence in SES than in PES. SF frequently occurred in the LAD artery and in complex lesions. Of the patients with SF, coronary intervention was performed only when the binary restenosis lesion was significant. During the follow-up, patients with SF have continued on combination antiplatelet therapy. There is a very low rate of major adverse cardiac events(post-detection of SF), especially cardiac death associated with SF.

An Analysis for Effects of Stain Family Drugs on Osteogenic Differentiation using Human Periosteum-derived Mesenchymal Stem Cells (스타틴(statin) 약물이 성체줄기세포의 골분화에 미치는 영향)

  • Moon, Dong Kyu;Yun, Jeong-Won;Kim, Bo Gyu;Lee, A Ram;Moon, Sun Young;Byun, June-Ho;Hwang, Sun-Chul;Woo, Dong Kyun
    • Journal of Life Science
    • /
    • v.29 no.12
    • /
    • pp.1337-1344
    • /
    • 2019
  • Osteoporosis is characterized by a reduction in bone mass and typically manifests as an increase in fractures. Because this disease is common in elderly populations and lifespans are rapidly increasing, the incidence of osteoporosis has also grown. Most drugs currently used for osteoporosis treatment target osteoclasts in the bone tissue to prevent absorption. However, these medications also cause certain side effects and, furthermore, cannot increase bone mass. Thus, in order to control osteoporosis, regenerative medicine that utilizes adult stem cells and osteoblasts has been extensively studied. Statins, also known as 3-hydroxy-3-methylglutaryl-coenzyme A (HMG-CoA) reductase inhibitors, are cholesterol-lowering drugs that have been widely prescribed for cardiovascular diseases. Interestingly, recent studies have reported the beneficial effects of various statins on bone formation via the activation of osteoblasts. Thus, the current study investigated the effects of seven statin-family drugs on osteoblast activity during osteogenic differentiation using adult stem cells from human periosteal tissue. Specifically, statin effects on alkaline phosphatase activity, an early marker of bone cell differentiation, and on calcium deposit, a late marker of bone cell differentiation, were assessed. The results demonstrate that some statins (for example, pitavastatin and pravastatin) have a weak but positive effect on bone formation, and the findings therefore suggest that statin treatments can be a novel modulator for osteogenic differentiation and regenerative medicine using periosteal stem cells.

Modelling of Fault Deformation Induced by Fluid Injection using Hydro-Mechanical Coupled 3D Particle Flow Code: DECOVALEX-2019 Task B (수리역학적연계 3차원 입자유동코드를 사용한 유체주입에 의한 단층변형 모델링: DECOVALEX-2019 Task B)

  • Yoon, Jeoung Seok;Zhou, Jian
    • Tunnel and Underground Space
    • /
    • v.30 no.4
    • /
    • pp.320-334
    • /
    • 2020
  • This study presents an application of hydro-mechanical coupled Particle Flow Code 3D (PFC3D) to simulation of fluid injection induced fault slip experiment conducted in Mont Terri Switzerland as a part of a task in an international research project DECOVALEX-2019. We also aimed as identifying the current limitations of the modelling method and issues for further development. A fluid flow algorithm was developed and implemented in a 3D pore-pipe network model in a 3D bonded particle assembly using PFC3D v5, and was applied to Mont Terri Step 2 minor fault activation experiment. The simulated results showed that the injected fluid migrates through the permeable fault zone and induces fault deformation, demonstrating a full hydro-mechanical coupled behavior. The simulated results were, however, partially matching with the field measurement. The simulated pressure build-up at the monitoring location showed linear and progressive increase, whereas the field measurement showed an abrupt increase associated with the fault slip We conclude that such difference between the modelling and the field test is due to the structure of the fault in the model which was represented as a combination of damage zone and core fractures. The modelled fault is likely larger in size than the real fault in Mont Terri site. Therefore, the modelled fault allows several path ways of fluid flow from the injection location to the pressure monitoring location, leading to smooth pressure build-up at the monitoring location while the injection pressure increases, and an early start of pressure decay even before the injection pressure reaches the maximum. We also conclude that the clay filling in the real fault could have acted as a fluid barrier which may have resulted in formation of fluid over-pressurization locally in the fault. Unlike the pressure result, the simulated fault deformations were matching with the field measurements. A better way of modelling a heterogeneous clay-filled fault structure with a narrow zone should be studied further to improve the applicability of the modelling method to fluid injection induced fault activation.

Differential Diagnosis of Metastatic Bone Disease and Benign Bone Disease on Spine SPECT in Patients with Low Back Pain (요통 환자의 척추골 SPECT에서 골전이 병변과 양성골질환의 섭취 양상 분석을 통한 감별진단이 가능한가)

  • Lee, Seung-Hun;Choi, Yun-Young;Cho, Suk-Shin
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.6
    • /
    • pp.371-377
    • /
    • 2001
  • Purpose: One or more abnormal vertebrae detected on bone scintigraphy is a common finding in clinical practice, and it could pose a diagnostic dilemma especially in cancer patients. as either metastasis or benign disease may cause scintigraphic abnormality. The purpose of this study was to determine whether additional spine SPECT has a role in differentiating malignant from benign lesions in patients with back pain. Materials and Methods: We reviewed spine SPECT studios obtained over a three-year period in 108 patients. Among them, forty-five patients with abnormal SPECT and clinically followed records were evaluated (20 cancer patients were included). Uptake patterns were classified as follows: 1. Body: diffusely increased uptake, linear increased uptake of end plate, segmental increased uptake, and cold defect, 2. Posterior element: posterior to body (pedicle), posterior to Intervertebral disc space (facet joint), and spinous process. Lesions were correlated with radiological findings and with final diagnosis. Results: Sixty-nine bone lesions were detected on SFECT images, including 18 metastases, 28 degenerative diseases and 21 compression fractures. Cold defect (6) and segmental increased uptake (5) were dominant findings in metastasis; linear increased uptake (12), and facet joint uptake (15) were in degenerative change; and diffuse increased uptake (9), and linear increased uptake (9) were in compression fracture. Conclusion: Cold defect and segmental increased uptake of body were characteristic findings of metastasis, but care should be taken because compression fracture also shows segmental increased uptake in some cases. Degenerative disease was easily diagnosed because of the typical finding of linear increased uptake of end plate and facet joint. Therefore, additional bone SPECT after planar bone scan would be helpful for differentiating metastasis from benign condition in cancer patients.

  • PDF

Fluid Inclusion Studies on the Wolak Tungsten-Molybdenum Deposits, Korea (월악 중석-몰리브덴 광상의 유체포유물 연구)

  • Lee, In Sung;Park, Hee-In
    • Economic and Environmental Geology
    • /
    • v.15 no.1
    • /
    • pp.17-32
    • /
    • 1982
  • The Wolak tungsten-molybdenum deposits are tungsten-molybdenum bearing quartz veins which filled the fractures in Pre-Cambrian pebble-bearing calcareous hornfels, hornfels and Cretaceous granite. There are two vein groups in this mine, Dongsan vein group in the west and Kwangcheon vein group in the east. The ore minerals are wolframite, scheelite, molybdenite, native bismuth, bismuthinite, pyrite, arsenopyrite, chalcopyrite, cubanite, stannite, pyrrhotite, sphalerite, galena, marcasite, Pb-Bi sulfosalt and ilmenite. Quartz, calcite, beryl, fluorite, muscovite, rhodochrosite and siderite are gangue minerals. Fluid inclusion studies were carried out for the quartz, beryl, scheelite, early and late fluorite. Fluid inclusion studies reveal that liquid-gas inclusions are most common and occur in all of the minerals examined. Filling degree of the inclusions in the late fluorite is much higher than that of the inclusions in quartz and early fluorite. Liquid $CO_2$ bearing liquid-gas inclusions occur in quartz and early fluorite. Liquid, gas and solid phase inclusions occur in quartz, beryl and scheelite. Salinities of inclusions in quartz and beryl from Dongsan vein group range from 3.9 to 8.0, from 5.3 to 7.7 wt.% NaCl equivalent respectively. Salinities in the late fluorite range from 1.5 to 3.2 wt.% NaCl equivalent. In Kwangcheon vein group salinities range from 3.9 to 9.6 wt.% NaCl equivalent in quartz, from 2.8 to 7.3 wt.% NaCl equivalent in early fluorite, from 1.3 to 1.5 wt.% NaCl equivalent in late fluorite. Homogenization temperatures of inclusions range from $239^{\circ}$ to higher than $360^{\circ}C$ in quartz, over $360^{\circ}C$ in scheelite, from $288^{\circ}C$ to higher than $360^{\circ}C$ in beryl, and from $159^{\circ}$ to $202^{\circ}C$ in late fluorite of the Dongsan vein group. In Kwangcheon vein group, homo genization temperatures of inclusions range from $240^{\circ}C$ to higher than $360^{\circ}C$ in quartz and from $240^{\circ}$ to $328^{\circ}C$ in early fluorite. As a whole, in Dongsan and Kwangcheon vein groups it seems that there are no distinct differences in mineralogy, salinities and homogenization temperatures. No distinct variations in homogenization temperatures are revealed through about 300 m vertically in both district. The faint trend of increase in salinities in the lower level can be detected. The salinity, $CO_2$ content and the temperature of ore fluid were much higher in the early vein stage and then dropped off in the late stage of mineralization as represented by the quartz and fluorite inclusion data.

  • PDF

Stable isotope, Fluid Inclusion and Mineralogical Studies of the Samkwang Gold-Silver Deposits, Republic of Korea (삼광 금-은광상의 산출광물, 유체포유물 및 안정동위원소 연구)

  • 유봉철;이현구;최선규
    • Economic and Environmental Geology
    • /
    • v.35 no.4
    • /
    • pp.299-316
    • /
    • 2002
  • The Samkwang gold-silver deposits consist of gold-silver-bearing hydrothermal massive quartz veins which filled the fractures along fault shear (NE, NW) zones within Precambrian banded or granitic gneiss of Gyeonggi massif. Ore mineralization of this deposits occurred within a single stage of quartz vein which was formed by multiple episodes of fracturing and healing. Based on vein mineralogy and paragenesis, massive quartz veins are divided into two main paragenetic stages which are separated by a major faulting event. Main ore mineralization occurred at stage I. Wall-rock alteration from this deposits occur as mainly sericitization, chloritization, silicification and minor amounts of pyritization, carbonitization, propylitization and argillitization. Ore minerals are composed mainly of arsenopyrite (29.21-32.24 As atomic %), pyrite, sphalerite (6.45-13.82 FeS mole %), chalcopyrite, galena with minor amounts of pyrrhotite, marcasite, electmm (39.98-66.82 Au atomic %) and argentite. Systematic studies of fluid inclusions in early quartz veins and microcracks indicate two contrasting physical-chemical conditions: 1). temperature (215-345$^{\circ}$C) and pressure (1296-2022 bar) event with $H_{2}O-CO_{2}-CH_{4}-NaCl$fluids (0.8-6.3 wt. %) related to the early sulfide deposition, 2). temperature (203-441$^{\circ}$C) and pressure (320 bar) event with $H2_{O}$-NaCI $\pm$ $CO_{2}$ fluids (5.7-8.8 wt. %) related to the late sulfide and electrum assemblage. The H20-NaCI $\pm$ $CO_{2}$ fluids represent fluids evolved through fluid unmixing of an $H_{2}O-CO_{2}-CH_{4}-NaCl$fluids due to decreases in fluid pressure and influenced of deepcirculated meteoric waters possibly related to uplift and unloading of the mineralizing suites. Calculated sulfur isotope compositions (${\delta}^{34}S_{fluid}$) of hydrothermal fluids (1.8-4.9$\textperthousand$) indicate that ore sulfur was derived from an igneous source. Measured and calculated oxygen and hydrogen isotope compositions (${\delta}^{18}O_{I120}$, ${\delta}D$) of ore fluids (-5.9~10.9$\textperthousand$, -102~-87$\textperthousand$) indicate that mesothermal auriferous fluids at Samkwang gold-silver deposits were likely mixtures of $H_{2}O$-rich, isotopically less evolved meteoric water and magmatic fluids.

The Effect of Surface Defects on the Cyclic Fatigue Fracture of HEROShaper Ni-Ti rotary files in a Dynamic Model: A Fractographic Analysis (Fractographic 분석을 통한 HEROShaper 니켈티타늄 전동 파일의 피로파절에 미치는 표면결함의 역할)

  • Lee, Jung-Kyu;Kim, Eui-Sung;Kang, Myoung-Whai;Kum, Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.2
    • /
    • pp.130-137
    • /
    • 2007
  • This in vitro study examined the effect of surface defects on cutting blades on the extent of the cyclic fatigue fracture of HEROShaper Ni-Ti rotary files using fractographic analysis of the fractured surfaces. A total of 45 HEROShaper (MicroMega) Ni-Ti rotary flies with a #30/.04 taper were divided into three groups of 15 each. Group 1 contained new HEROShapers without any surface defects. Group 2 contained HEROShapers with manufacturing defects such as metal rollover and machining marks. Croup 3 contained HEROShapers that had been clinically used for the canal preparation of 4-6 molars A fatigue-testing device was designed to allow cyclic tension and compressive stress on the tip of the instrument whilst maintaining similar conditions to those experienced in a clinic. The level of fatigue fracture time was measured using a computer connected the system. Statistical analysis was performed using a Tukey's test. Scanning electron microscopy (SEM) was used for fractographic analysis of the fractured surfaces. The fatigue fracture time between groups 1 and 2, and between groups 1 and 3 was significantly different (p<0.05) but there was no significant difference between groups 2 and 3 (p>0.05). A low magnification SEM views show brittle fracture as the main initial failure mode At higher magnification, the brittle fracture region showed clusters of fatigue striations and a large number of secondary cracks. These fractures typically led to a central region of catastrophic ductile failure. Qualitatively, the ductile fracture region was characterized by the formation of microvoids and dimpling. The fractured surfaces of the HEROShapers in groups 2 and 3 were always associated with pre-existing surface defects. Typically, the fractured surface in the brittle fracture region showed evidence of cleavage (transgranular) facets across the grains, as well as intergranular facets along the grain boundaries. These results show that surface defects on cutting blades of Ni-Ti rotary files might be the preferred sites for the origin of fatigue fracture under experimental conditions. Furthermore this work demonstrates the utility of fractography in evaluating the failure of Ni-Ti rotary flies.