• Title/Summary/Keyword: fractured aquifer

Search Result 56, Processing Time 0.027 seconds

Hydraulic Eroperty of Groundwater Flow Controlled by Vertical Geologic Structure and its field Example (수직 지질구조에 의해서 지배되는 암반지하수 유동의 수리적 성질과 그 예)

  • 함세영;김형찬;임정웅
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.5 no.2
    • /
    • pp.101-109
    • /
    • 1998
  • Hydraulic property of fissured aquifers often depends on geologic structure which acts main channel of groundwater flow. We treated theories of linear flow related to vertical geologic structure. Then, we analyzed the result of two pumping tests conducted in Okmyeong-ri area (Kyeongbook province) using fractal model and found hydraulic characteristic of the fissured aquifer in this area. According to the pump test analyses, groundwater flow around the holes (pumping well D9; observation wells C3 and D7) of test 1 is linear. and is controlled by vertical geologic structure with infinite length and infinitesimally small width. On the other hand, around the hole D10 (pumping well) of test 2, groundwater flow is pseudo-radial (n=1.9) or radial (n=2). Thus, the characteristic of fractured aquifer often shows variable groundwater flow spatially and temporally.

  • PDF

Analysis of oscillatory responses of slug tests in a crystalline rock aquifer (암반대수층 내 순간충격시험 시 관찰된 요동반응의 해석)

  • Ryu, I.;Ji, S.H.;Koh, Y.
    • Tunnel and Underground Space
    • /
    • v.19 no.4
    • /
    • pp.348-354
    • /
    • 2009
  • Slug test is a common characterization method that estimates aquifer hydraulic conductivity rapidly and economically. To characterize the hydraulic property near the borehole YS-4 in the Korea Atomic Energy Research Institute (KAERI) site, slug tests were performed, and oscillatory hydraulic responses were observed. We analyzed the observations with the modified Hvorslev and Bouwer&Rice methods considering the casing inertia, and then the results were compared with those from the general Hvorslev and Bouwer&Rice methods. The estimated hydraulic conductivities from the modified methods are ranged from $4.85{\times}10^{-6}$ to $5.44{\times}10^{-6}$ m/sec, but those from the general ones are ranged from $3.10{\times}10^{-6}$ to $3.63{\times}10^{-5}$ m/s, which shows that the oscillatory responses should be analyzed with consideration of the flowing water inertia effect.

A Pole-pole Electrical Survey for Groundwater (2극법 전기비저항 탐사에 의한 지하수탐사)

  • Cho Dong-heng;Jee Sang-keun
    • Geophysics and Geophysical Exploration
    • /
    • v.3 no.3
    • /
    • pp.88-93
    • /
    • 2000
  • The present study may be summarized as follows. By means of a pole-pole electrical survey, major geological features, i.e, fresh rocks, fractured & weak & saturated rocks, fresh water bearing aquifer, were successfully delineated in the surveyed area of a granite region in Korea. The subsequent Schlumberger sounding and drilling confirmed the existence of the acquifer at 60 m depth as expected. But one more minor acquifer which does not show up in the resistivity depth section was met at 100 m depth. A simple forward modelling leads the authors to believe that any other electrode configuration, e.g., Wenner, Schlumberger, dipole-dipole, pole-dipole, would not detect the deeper aquifer. Under these circumstances, further studies remain to be done in connection with the spatial resolution in the vertical direction.

  • PDF

Analysis of transmissivity tensor in an anisotropic aquifer (이방성 대수층에서의 투수량계수텐서 해석)

  • 강철희;이대하;김구영;이철우;김용제;우남칠
    • Journal of Soil and Groundwater Environment
    • /
    • v.7 no.2
    • /
    • pp.53-61
    • /
    • 2002
  • An Aquifer test was carried out on five boreholes to determine the hydrologic anisotropy and the major groundwater flow direction in the aquifer system of the study area. With an assumption of the aquifer's anisotropy and homogeneity, the major transmissivity(T(equation omitted)), the minor transmissivity( $T_{ηη}$ ), and primary tensor direction ($\theta$) for each borehole were determined from the test. Besides the boreholes BH-1, BH-4 and BH-5, the anisotropy transmissivity tensor values of BH-2 and BH-3 did not correspond with the assumption. Thereafter the values were plotted on the polar coordinate, and showed that the tensor values were out of the anisotropy ellipsoid due to the high heterogeneity of BH-2 and BH-3 comparing with the other boreholes. Therefore. the anisotropy of the aquifer was examined from BH-1, BH-4. and BH-5. In BH-1, T(equation omitted) is 171.9 $\m^2$/day. $T_{ηη}$ is $71.01\m^2$/day, and the principal tensor direction is Nl5.39$^{\circ}$E. In BH-4. T(equation omitted) is $268.2 \m^2$/day, $T_{ηη}$ / is $28.75\m^2$/day and the principal tensor direction is N7.55$^{\circ}$E. In BH-5, T(equation omitted) is $168.4\m^2$/day, $T_{ηη}$ is 66.80 $\m^2$/day, and the principal tensor direction is $N76.59^{\circ}$E. On the basis of teleview logging performed on each borehole. the principal fracture directions were revealed as $N0^{\circ}$~4$^{\circ}$E/$30^{\circ}$~$50^{\circ}$SE and $N30^{\circ}$~$80^{\circ}$W/$20^{\circ}$~$50^{\circ}$NE that are the most frequently occurred sets as well as that correspond well with the calculated transmissivity tensor.

Numerical Simulation of Groundwater Flow in Feterogenetic Rockmass of Unsaturated Condition (암반의 불균질성을 고려한 불포화대 지하수 유동 평가)

  • Ha, Jaechul;Lee, Jeong Hwan;Cheong, Jae-yeol;Jung, Haeryong
    • The Journal of Engineering Geology
    • /
    • v.26 no.1
    • /
    • pp.87-99
    • /
    • 2016
  • We present the results of two-dimensional numerical simulations predicting the flow of groundwater in a fractured unsaturated zone. We applied the k-field distribution of permeability derived from discrete fracture network (DFN) modeling as the hydraulic properties of a model domain. To model an unsaturated zone, we set the depth from the ground surface to the underground aquifer. The rate of water infiltration into the unsaturated zone was divided into two parts, an artificial structure surface and unsaturated soil zone. The movement of groundwater through the unsaturated zone was simulated with particular emphasis on contaminant transport. It was clearly observed that the contaminants dissolved in groundwater transported vertically from the ground surface to the saturated zone.

Determination of Aqnifer Characteristics from Specific Capacity Data of Wells in Cheju Island (제주도 지하수의 우물 비양수량자료를 이용한 대수층상수 결정방법)

  • 최병수
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.6 no.4
    • /
    • pp.180-187
    • /
    • 1999
  • Transmissivity is often estimated from specific capacity data because of the expense of conducting standard aquifer test to obtain transmissivity and the relative availability of specific capacity data. Most often, analytic expression relating specific capacity to transmissivity derived by Theis (1963). Brown (1963). and Logan (1964) are used in this analysis. The analytic solution typically used to predict transmissivity from specific capacity in alluvial aquifers assuming influence radius and/or storage coefficient of the aquifers. But those do not agree well with the measured transmissivity in fractured rock aquifers and in heterogeneous aquifers. Razack-Huntely (199l). Huntely-Steffey (1992). and Mace (1997) proposed emphirical rotations between specific capacity and transmissivity in heterogeneous alluvial aquifers. fractured rock aquifers, and karst aquifers. This study focuses on comparison between transmissivity and specific capacity data in volcanic rock aquifers of Jeju Island. Emphirical relation between the log of transmissivity and the log of specific capacity suggests they no linearly related (correlation coefficient 0.951) and the width of $\pm$0.25 log cycles in transmissivity includes 96.6% of data.

  • PDF

Analysis of Aquifer Test Data in Fractured Aquifers and the Application of the Generalized Radial Flow (균열암반에서의 양수시험자료 해석과 일반 방사상 유동모델의 적용성 연구)

  • Seong Hyeonjeong;Kim Yongie;Lee Chul-Woo;Kim Kue-Young;Woo Nam-Chil
    • Economic and Environmental Geology
    • /
    • v.38 no.2 s.171
    • /
    • pp.177-185
    • /
    • 2005
  • Data from 122 pumping tests were obtained from 100 boreholes in granites, volcanic rocks, metamorphic rocks, and Cretaceous and Tertiary sedimentary rocks, and then were analyzed using AQTESOLV. Results from 86 of the 122 tests ($71\%$) have an analytical solution corresponding to Theis (1935), Cooper-Jacob (1946), Papadopulos-Cooper (1967), Hantush (1962), Moench (1985), or Hantush-Jacob (1955), whereas the remaining 36 results ($29.5\%$) do not correspond to any of the analytical methods. Of the 86 results, only 17 match the Theis and Cooper-Jacob methods, indicating that the basic methods fer pumping test analysis are useful far only $14\%$ of the total data. This suggests that analytical solutions derived using leaky boundary conditions are appropriate for the analysis of pumping test data in fractured aquifers in this study. Furthermore, the results show the importance of carefully selecting an appropriate model for the analysis of pumping test data. Results from the 122 pumping tests were also analyzed using the GRF model. Using the Barker method, the results show that 77 of the 122 tests ($63\%$) have dimensions ranging between 1.1-2.9. Of these 77 solutions, ($39(44.2{\%})$) have a fractional dimension of 1.1-1.9, ($26(6.5{\%})$) show 2-dimensional radial flow also applicable to the Theis method, and ($38(49.3{\%})$) have dimensions of 2.1-2.9. The results show that groundwater flows according to a fractional flow dimension in fractured aquifers.

Detection of inflow permeable zones using fluid conductivity logging in coastal aquifer (공내수 치환기법을 이용한 연안지역 대수층의 수리특성 평가)

  • Hwang Seho;Park Yunsung;Shim Jehyun;Park Kwon Gp;Choi Sun Young;Lee Sang Kyu
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2005.09a
    • /
    • pp.83-92
    • /
    • 2005
  • Fluid conductivity logging has been applied in the boreholes to identify the permeable fi:actures and estimate the origin of saline groundwater in coast area. Fluid replacement technique measures the fluid electrical conductivity with depth at different times in a well after the borehole is first washed out with different water by passing a tube to the borehole bottom. Then formation water flows into the borehole through aquifer such as permeable fractures or porous formation during ambient or pumping condition. Measured conductivity profiles with times therefore indicate the locations of permeable zone or fractures within the open hole or the fully slotted casing hole. As a result of fluid conductivity logging for three boreholes in the study area, it is interpreted that saline groundwater is caused by seawater intrusion through fractured rock, although the effect by land reclamation partially remains. We are planning the quantitative analysis to estimate the hydraulic characteristics using fluid replacement technique, and this approach might be usefully utilized for assessing the characteristics of seawater intrusion, the design of optimal pumping, and estimating the hydraulic properties in coastal aquifer.

  • PDF

Hydrogeologic Structure derived from Electrical and CSMT Surveys in the Chojung Area (전기 및 CSMT 탐사를 이용한 초정지역의 수리지질 구조 해석)

  • Song Sung-Ho;Yong Hwan-Ho;Kim Jin-Ho;Song Seung-Yup;Chung Hyung-Jae
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.2
    • /
    • pp.118-125
    • /
    • 2002
  • The hydrogeologic structure in the Chojung area was evaluated from a set of geological and geophysical investigations: detailed geological survey, vertical electric sounding (VES), borehole logging, and controlled-source magnetotelluric (CSMT) survey. Among these, CSMT soundings were taken for integrated interpretation to extend hydrogeologic structure with depth. The result of CSMT survey along with VES and borehole logging provides the vertical geologic boundary connected with hydrogeologic structure, and also indicates the depth of aquifer in granite basement. To interpret the geologic boundary and aquifer characteristics using CSMT data, we adopted the technique of 1-D inversion with smoothness-constrained method and 2-D continuous profiling with 1-D Bostick inversion and spatial filtering. The methodology tested and adopted in this study would be useful and required for providing a more information to the structure of fractured aquifer system.

Preliminary study for hydraulic properties of fractured rock aquifer using the deep borehole (심부시추공을 활용한 결정질암반 대수층에 대한 수리적 예비연구)

  • Cho, Chung-Ho;Park, Kyung-Woo;An, Sang-Won;Kim, Kyung-Su;Han, Woon-Woo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1929-1933
    • /
    • 2009
  • 수자원 수요가 급증함에 따라 단열 암반 대수층의 지하수를 개발해 이용하려는 연구가 많이 이루어지고 있다. 본 연구에서는 단열암반 대수층의 지하수 유동 특성을 알아보기 위해 한국원자력연구원 연구 지역 내에 NX 규격의 직경 78mm를 갖는 500m 심도의 심부시추공 (DB-01)을 굴착하였다. DB-01에 대한 시추공 단열조사 (BHTV) 및 시추코아 분석을 통해서 심부 시추공에 대한 예비 투수성 구조를 도출하였으며, 투수성이 큰 구조로 단열과 연결된 지점으로 판단되는 심도에 대해서 현장 수리시험을 수행하여, 결정질 암반의 투수성 구조에 대한 수리특성을 규명하였다. 그 결과를 분석하여 비교적 투수성이 큰 심도를 결정질 암반의 대수층이라 정의하였다. 수리특성이 비슷한 3가지의 그룹 중 3그룹은 투수계수도 가장 크고 단열빈도도 밀집되어 있는 것으로 나와 심부 200m에서 250m이하의 이 단열구간은 수자원으로 지하수의 활용이 가능하다고 여겨진다.

  • PDF