• Title/Summary/Keyword: fracture repair

Search Result 254, Processing Time 0.024 seconds

Numerical Analysis of Interfacial Fracture Behavior in Repaired Structures. (구조 보강재와 피보강재 접합경계면의 역학적 특성에 관한 해석적 연구)

  • 박진완;신승교;임윤묵;김문겸
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.471-474
    • /
    • 1999
  • An interface always appears when a repair is applied to an aged infrastructure system for repair. These repaired structures have the high chance to fail along the interface because of the stress concentration/discontinuity along the interface. So, mechanical properties of the interface have much influence on the behavior of repaired structure systems. In this paper, numerical tool that can predict effectively the interfacial fracture behavior is developed using axial deformation link elements, and this numerical technique is applied to the interfacial failure behavior. The results coincide with the ultimate strength and failure profile on the interfacial behavior of carbon fiber sheets for strengthening with epoxy adhesion. Thus, the mechanical behavior of the interface up to failure can be predicted using numerical technique with the proposed axial deformation link elements.

  • PDF

Free Flap Transplantation in Open Tibial Fracture with Vessel Injury in the Elderly

  • Yu, Chang Eun;Yoo, Myung-Jae;Lee, Jun-Mo
    • Archives of Reconstructive Microsurgery
    • /
    • v.23 no.1
    • /
    • pp.18-20
    • /
    • 2014
  • Two aged patients who had open tibial fractures with arterial injury caused by high energy accidents underwent emergency arterial reconstruction using a greater saphenous vein and soft tissue repair using free flaps. In the patients, soft tissue necrosis developed and tibias were exposed at postoperative third week. Follow-up angiography through the superficial femoral artery showed occlusion of the anterior tibial artery. The anterior tibial artery was reconstructed using the contralateral greater saphenous vein graft and the latissimus dorsi myocutaneous and rectus abdominis muscle free flaps were transplanted for repair of necrotic soft tissue. The reconstructed arteries showed good perfusion to the new free flaps until union of the tibias occurred. The patients were followed-up for 21 years and 17 years postoperatively, respectively. In management of open comminuted fracture of the tibia, injury of the arterial system must be ruled out by angiography in addition to evaluation of the degree of soft tissue injury.

Longitudinal Supraspinatus Tear Associated with Antegrade Humeral Intramedullary Nailing: A Case Report and Literature Review with Focus Placed on Nail Entry Point

  • Shon, Min Soo;Bang, Tae Jung;Yoo, Jae Chul
    • Clinics in Shoulder and Elbow
    • /
    • v.18 no.1
    • /
    • pp.47-51
    • /
    • 2015
  • Iatrogenic damage of the rotator cuff followed by postoperative shoulder function loss is a potential complication after antegrade intramedullary nailing (AIN) for a humeral fracture. The authors present a case of arthroscopic rotator cuff repair and subacromial decompression of a non-healed rotator cuff tendon (mainly supraspinatus) and secondary impingement syndrome caused either by the tear or a proud nail after AIN for a mid-shaft humeral fracture. At presentation, the patient complained of right shoulder pain and 'snapping', especially during forward elevation and abduction of the shoulder, of 4 years duration. Right shoulder pain started sometime after pain due to the humeral shaft fracture, operation had subsided, and persisted after nail removal. Arthroscopic findings showed a longitudinal rotator cuff tear at the nail entry point that had not healed and severe fibrous hypertrophy on the acromion underspace, which is a unique finding since most longitudinal splits of tendon fibers are more likely to heal than conventional rotator cuff tears detached from bone. The torn rotator cuff was repaired after debridement and placing side-to-side sutures. At his 34-month follow-up after rotator cuff repair, the patient showed complete recovery and had excellent clinical scores.

Ruptured Posterior Tibial Tendon in Closed Ankle Fracture - A Case Report - (폐쇄성 족관절 골절에 동반된 후경골건 파열 - 1예 보고 -)

  • Choi, Joong-Geun;Woo, Seung-Han
    • Journal of Korean Foot and Ankle Society
    • /
    • v.6 no.1
    • /
    • pp.92-95
    • /
    • 2002
  • Traumatic ruptures of tibialis posterior tendon are much less common and consequently have received little attention. A tibialis posterior tendon rupture associated with a closed medial malleolar fracture occured in a 32 years old man due to slip down. The tendon rupture was not diagnosed before surgery but was recognized at the time of open operation. The treatment was open reduction and internal fixation at the bony fragments with primary repair of the tendon. This tendon injury, although rare, should be considered in the management of ankle fracture because the tendon rupture could easily have been overlooked and failure to recognize this at the time of injury may result in poor long - term ankle function despite a well- healed fracture.

  • PDF

Avulsion Fracture of Medial Cuneiform by Tibialis Anterior Tendon (A Case Report) (내측 설상골에 발생한 전 경골건에 의한 견열 골절 (1예 보고))

  • Ahn, Su-Han;Kim, Hyung-Chun;Kim, Kwang-Yeol;Yoon, Hyeong-Jo;Kim, In-Yeol
    • Journal of Korean Foot and Ankle Society
    • /
    • v.14 no.2
    • /
    • pp.194-196
    • /
    • 2010
  • Avulsion fracture of medial cuneiform by tibialis anterior tendon is quite rare. It has been reported about the avulsion fracture and surgical repair of tibialis anterior tendon rupture at distal insertion site of medial cuneiform in Korea. We report a case of right foot medial cuneiform avulsion fracture by tibialis anterior tendon after autobike accident and describe this case with a review of literature.

Achilles Tendon Rupture Associated with Ipsilateral Bimalleolar Fracture (A Case Report) (아킬레스건 파열과 동반된 동측 족관절 양과 골절(1예 보고))

  • Chung, Hyung-Jin;Bae, Su-Young;Min, Byoung-Kwon;Song, Min-Cheol
    • Journal of Korean Foot and Ankle Society
    • /
    • v.15 no.2
    • /
    • pp.107-109
    • /
    • 2011
  • We report here on a case of Achilles tendon rupture associated with ipsilateral bimalleolar fracture that was caused by ski injury. The association of an ankle fracture with rupture of the Achilles tendon is even more infrequent, although both injuries alone are extremely common. We treated as a operation of Achilles tendon repair with Krackow method and open reduction with Tension-band wiring technique for bimalleolar fracture.

Displaced Scapula Fracture (Ideberg Type IIb) Combined with a Large Rotator Cuff Tear in Anterior Shoulder Dislocation: A Case Report

  • Noh, Young-Min;Kim, Chul-Hong;Lee, Seung-Hyun;Im, Chul-Soon
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.3
    • /
    • pp.162-166
    • /
    • 2017
  • Traumatic anterior shoulder dislocation combined with scapular fracture in elderly patients is relatively rare. In this case, a patient visited Emergency Room of Dong-A University Hospital for shoulder pain after falling off a ladder. Radiographs demonstrated anterior shoulder dislocation with displaced Ideberg type IIb scapula (glenoid fossa) fracture combined with a large rotator cuff tear on magnetic resonance imaging. We performed arthroscopic rotator cuff repair, but a large fragment in the inferior glenoid was left untreated. At the 1 year follow-up visit, the pain visual analogue scale of the patient was 2, the American Shoulder and Elbow Society score was 88 and the patient had gained nearly full range of motion without any apprehension.

Numerical study of bonded composite patch repair in damaged laminate composites

  • Azzeddine, Nacira;Benkheira, Ameur;Fekih, Sidi Mohamed;Belhouari, Mohamed
    • Advances in aircraft and spacecraft science
    • /
    • v.7 no.2
    • /
    • pp.151-168
    • /
    • 2020
  • The present study deals with the repair of composite structures by bonding composite patches. The composite structure is a carbon/epoxy laminate with stacking sequence [45/-45/0/90]S. The damaged zone is simulated by a central crack and repaired by bonding symmetrical composite patches. The repair is carried out using composite patches laminated from the same elemental folds as those of the cracked specimen. Three-dimensional finite element method is used to determine the energy release rate along the front of repaired crack. The effects of the repair technique used single or double patch, the stacking sequence of the cracked composite patch and the adhesive properties were highlighted on the variations of the fracture energy in mode I and mixed mode I + II loading.

Minimally invasive distal biceps tendon repair: a case series

  • Paul Jarrett;Anna-Lisa Baker
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.3
    • /
    • pp.222-230
    • /
    • 2023
  • Background: Distal biceps tendon repairs are commonly performed using open techniques. A minimally invasive distal biceps tendon repair technique using a speculum and hooded endoscope was developed to improve visualization, reduce soft-tissue dissection, and minimize complications. This paper describes the technique and reports the outcomes of 75 minimally invasive distal biceps tendon repairs. Methods: The operation reports and outcomes of 75 patients who underwent distal biceps tendon repair using this technique between 2011 and 2021 were retrospectively reviewed. Results: Median time to follow-up was 12 months (interquartile range [IQR], 6-56 months). Primary outcomes were function as measured by the Disabilities of Arm, Shoulder and Hand Score (DASH) questionnaire, and rate of complications. Median DASH score was 1.7 of 100 (IQR, 0-6.8). There were 2 of 75 (2.7%) re-ruptures of the distal tendon. There were no cases of vascular injury, proximal radius fracture, or posterior interosseous nerve, median, or ulnar nerve palsy. Conclusions: In this series, minimally invasive distal biceps repair was safe and effective with a low rate of major complications. Recovery of function, as indicated by low DASH scores, was satisfactory, and inconvenience during recovery was minimized. Level of evidence: IV.

Open Reduction of Proximal Interphalangeal Fracture-Dislocation through a Midlateral Incision Using Absorbable Suture Materials

  • Lee, Jae Jun;Park, Hyoung Joon;Choi, Hyun Gon;Shin, Dong Hyeok;Uhm, Ki Il
    • Archives of Plastic Surgery
    • /
    • v.40 no.4
    • /
    • pp.397-402
    • /
    • 2013
  • Background Fracture-dislocation of the proximal interphalangeal (PIP) joint is a relatively common injury. Various treatments for fracture-dislocation of the PIP joint have been reported. In the present study, we performed open reduction through a midlateral incision using absorbable sutures to reduce the small bone fragments and performed volar plate repair. Methods We treated nine patients with fracture-dislocation of the PIP joint with small fractured bone fragments too small for pinning or screw fixation. Patients with volar plate injury were treated with open reduction and volar plate repair at the periosteum of the middle phalangeal bone base by the modified Kessler method using absorbable sutures. All patients were placed in a dorsal aluminum extension block splint, which maintained the PIP joint in approximately 30 degrees of flexion to avoid excessive tension on the sutured volar plate. Results At a mean final follow-up of postoperative 9 months, all patients were evaluated radiographically and had adequate alignment of the PIP joint and reduction of the displaced bone fragments. Range of motion was improved and there were no complications. Conclusions This technique is an excellent alternative to the current method of treating patients with fracture-dislocations that include small fragments that are too small for pinning or screw fixation. It is a less invasive surgical method and enables stable reduction and early exercise without noticeable complications.