• Title/Summary/Keyword: fracture pressure

Search Result 891, Processing Time 0.036 seconds

Full mouth rehabilitation of an asthma patient with severe tooth wear and occlusion disharmony (심한 마모 및 교합 부조화를 가진 천식 환자의 전악 수복 증례)

  • Jo, Yu-Jin
    • Journal of Korean society of Dental Hygiene
    • /
    • v.22 no.4
    • /
    • pp.225-230
    • /
    • 2022
  • Objectives: Patients with excessive tooth wear should first be diagnosed for the etiology of the tooth wear. Causes of tooth wear include bruxism, clenching, and taking medications for systemic diseases. After identifying the cause of tooth attrition, the final prosthesis should be restored with an appropriate vertical dimension. Methods: A 79-year-old man with worn out teeth desired a whole dental treatment. He was on medications for high blood pressure and asthma. The treatment proceeded with a consultation with a medical doctor. The medications for asthma evoked multiple teeth wear and a loss of the vertical dimension. After recovery of 3 mm of vertical dimension, 2 months of evaluation was followed by an interim prosthesis. Results: The increased vertical dimension caused no problem in function and esthetics, and the final restoration was performed with a full monolithic zirconia crown. Group function, adequate anterior guidance, and the occlusal plane were determined. Conclusions: After the final restoration, the patient was both esthetically and functionally satisfied, and a night guard splint was delivered to prevent prosthesis fracture. The patient was informed about the potential tooth wear associated with asthma drugs and educated to visit the clinic regularly.

Analysis of Failure Behavior of the Box Culvert with 3-Axes Loading System (3축 가력시스템에 의한 박스형 암거의 파괴거동 분석)

  • Woo, Sang-Kyun;Kwon, Yong-Gil;Cho, Jun-Hyong;Han, Sang-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.5 s.57
    • /
    • pp.142-148
    • /
    • 2009
  • This paper is to investigate the fracture behavior characteristics of box culvert and incremental crack width of upper slab for the incremental loading by the 3-axis loading system. In the 3-axes loading system, loading directions are upper side, left and right side which simulate earth pressure and static traffic load. With the incremental load, crack patterns is investigated on the upper slab, left and right wall. Especially, on the upper slab, crack width is measured by crack gage. Based on the experimental results, structural internal force indices of box culvert are estimated quantitatively.

Acquisition and Verification of Dynamic Compression Properties for SHPB of Woven Type CFRP (Woven Type CFRP의 SHPB에 대한 동적 압축 물성 획득 및 검증)

  • Park, Ki-hwan;Kim, Yeon-bok;Kim, Jeong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.5
    • /
    • pp.363-372
    • /
    • 2020
  • Dynamic compressive material properties at high strain rates is essential for improving the reliability of finite element analysis in dynamic environments, such as high-speed collisions and high-speed forming. In general, the dynamic compressive material properties for high strain rates can be obtained through SHPB equipment. In this study, SHPB equipment was used to acquire the dynamic compressive material properties to cope with the collision analysis of Woven tpye CFRP material, which is being recently applied to unmanned aerial vehicles. It is also used as a pulse shaper to secure a constant strain rate for materials with elastic-brittle properties and to improve the reliability of experimental data. In the case of CFRP material, since the anisotropic material has different mechanical properties for each direction, experiments were carried out by fabricating thickness and in-plane specimens. As a result of the SHPB test, in-plane specimens had difficulty in securing data reproducibility and reliability due to fracture of the specimens before reaching a constant strain rate region, whereas in the thickness specimens, the stress consistency of the specimens was excellent. The data reliability is high and a constant strain rate range can be obtained. Through finite element analysis using LS-dyna, it was confirmed that the data measured from the pressure rod were excessively predicted by the deformation of the specimen and the pressure rod.

A Study on Integrated Control and Safety Management Systems for LNG Membrane Storage Tank (멤브레인식 LNG 저장탱크용 통합제어안전관리시스템에 대한 연구)

  • Kim, Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.2
    • /
    • pp.40-46
    • /
    • 2010
  • In this study, the integrated control and safety management system for a super-large LNG membrane storage tank has been presented based on the investigation and analysis of measuring equipments and safety analysis system for a conventional LNG membrane storage tank. The integrated control and safety management system, which may increase a safety and efficiency of a super-large LNG membrane storage tank, added additional pressure gauges and new displacement/force sensors at the steel anchor between an inner tank and a prestressed concrete structure. The displacement and force sensors may provide clues of a membrane panel failure and a LNG leakage from the inner tank. The conventional leak sensor may not provide proper information on the membrane panel fracture even though LNG is leaked until the leak detector, which is placed at the insulation area behind an inner tank, send a warning signal. Thus, the new integrated control and safety management system is to collect and analyze the temperature, pressure, displacement, force and LNG density, which are related to the tank system safety and leakage control from the inner tank. The digital data are also measured from measurement systems such as displacement and force of a membrane panel safety, LNG level and density, cool-down process, leakage, and pressure controls.

A Study on Applicability and External / Internal Stability of true MSEW abutment with slab (순수형 보강토교대의 슬래브교에 대한 적용성 및 외적/내적 안정성 검토)

  • Park, Min-Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.263-274
    • /
    • 2018
  • In this study, the applicability and external/internal stability of a MSEW abutment with a slab were investigated. Structural analysis of slab bridges between 10 ~ 20.0 m and thicknesses of 0.7 ~ 0.9 m was carried out to calculate the reaction forces due to dead and live loads acting on the bridge supports. The slab bridge with a length of 20.0 m satisfied the allowable contact pressure of 200 kPa for the true MSEW abutment. Because the external stability of the true MSEW abutment was dominated by the geometry of the MSE wall, the change in the factor of safety due to the load of the super-structure is small. Because the stiffness of the foundations is fixed and the load of the super-structure is increased, the factor of safety of the bearing capacity was reduced. As the load of the super-structure was increased, the horizontal earth pressure of the true MSEW abutment increased greatly. As a result, the pullout and fracture of the uppermost reinforcement, which are the factors of safety, did not meet the design criteria. Therefore, it is necessary to increase the pullout resistance and the long-term allowable tensile force of the reinforcement placed on the top of the reinforced soils to ensure efficient design and performance of a true MSEW abutment.

Structure/Property of Adhesives and Adhesion Performance (접착제의 구조물성과 접착특성)

  • Hiroshi Mizumachi
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.29 no.1
    • /
    • pp.73-83
    • /
    • 1997
  • Most of the materials used in various industrial fields and also in our daily life are multi-component materials or composite materials, and it is well known that there are many cases where adhesion between the constituents within the bonded systems plays an important role. There are various types of performance evaluation tests for the bonded materials, among which tests for evaluating the bond performance under various conditions may be regarded as the most interesting ones for those engaged in work related to adhesion. I have studied on the mechanism of adhesion form the rheological standpoint with my colleagues, including some students from Korea, and I am very happy to be able to have a talk on some of our research works. In Japan, the so-called "adhesives" are usually classified into two categories;adhesives and pressure sensitive adhesives (PSA). Adhesives are the materials which solidify after bonding and are after used as the structural adhesives because the adhesive strength is comparatively strong. On the other hand, the pressure sensitive adhesives never solidify and are used as PSA tapes, labels or decals. About the adhesives, we have examined the dependence of adhesive strength(shear, tensile, peel) upon both temperature and rate of deformation, and found out some empirical rules which are applicable to most of the adhesive systems. We have also developed a simplified theory of adhesion, which is deseribed in terms of mechanical equivalent mode1 and a few failure criteria. Although some of the common rules can be accounted for according to this theory, it must be pointed out that a fracture mechanical approach ms inevitable especially in the region where the meehanical relaxation time of the adhesive is extremely large [W. W. Lim and H. Mizumachi]. About the pressure sensitive adhesives, we have studied on the PSA performance (peel, tack, holding power) as a function of both the viscoelastic properties and surface chemical properties of the materials, and found out some rules, and again we have developed a theory which deseribes the mechanism. And in addition, we have studied on the miscibility between linear polymers and oligomers, because PSA is generally manufactured by blending gums and tackifier resins. Many phase diagrams have been found and some of them have been analyzed on thermodynamic basis, and it became evident that the miscibility is a very important factor in PSA [H. J. Kin and H. Mizumachi]. In this presentation, I want to emphasize the fact that the adhesion performance is closely related to the structure/property of the adhesives.adhesives.

  • PDF

Effect of amount of magnesia on wear behavior of silicon nitride (마그네시아 양이 질화규소의 마모거동에 미치는 영향)

  • 김성호;이수완;엄호성;정용선
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.9 no.2
    • /
    • pp.231-239
    • /
    • 1999
  • The microstructure of ceramic composite has been found to be governed by the type and amount of the secondary phase, the sintering aid, and the sintering conditions such as sintering temperature, pressure and holing time. Moreover, tribological properties are strongly dependent on microsturcture of composite and operating conditions. In this study, silicon nitride with various amount of magnesia as a sintering aid were prepared and sintered by a hot pressing (HP) technique. Microstructure, mechanical properties (hardness, strength, and fracture toughness), and tribological properties in different environments of $Si_{3}N_{4}$ (in air, water, and paraffine oil) were investigated as a function of MgO content in $Si_{3}N_{4}$. As increasing the amount of MgO in $Si_{3}N_{4}$, the glassy phase in the grain boundaries enlarged the $\beta$-phase elongated grains, and also degraded the Hertzian contact damage resistance. Tribological behaviors in air was seemed to be determined by fracture toughness of $Si_{3}N_{4}$, and those in water and paraffin oil was seemed to be determined by hardness as well as strength. Since glassy grain-boundary phase (MgO) in $Si_{3}N_{4}$ expected to be reacted with water during sliding, such tribochemical reaction reduced wear. In paraffin oil under a higher applied load, the initial sliding dominated wear rate because of Hertzian contact damage.

  • PDF

Clinical Characteristics of Unstable Pelvic Bone Fractures Associated with Intra-abdominal Solid Organ Injury (불안정성 골반골 골절 손상에서 동반 복부 고형장기 손상의 임상적 특성)

  • Lee, Sang Won;Kim, Sun Hyu;Hong, Eun Seog;Ahn, Ryeok
    • Journal of Trauma and Injury
    • /
    • v.25 no.1
    • /
    • pp.1-6
    • /
    • 2012
  • Purpose: This study analyzed the characteristics of unstable pelvic bone fractures associated with intra-abdominal solid organ injury. Methods: Medical records were retrospectively collected from January 2000 to December 2010 for patients with unstable pelvic bone fractures. Unstable pelvic bone fracture was defined as lateral compression types II and III, antero-posterior compression types II and III, vertical shear and combined type by young classification. Subjects were divided into two groups, with (injured group) and without (non-injured group) intra-abdominal solid organ injury, to evaluate whether the characteristics of the fractured depended on the presence of associated solid organ injury. Data included demographics, mechanism of injury, initial hemodynamic status, laboratory results, revised trauma score (RTS), abbreviated injury scale (AIS), injury severity score (ISS), amount of transfusion, admission to the intensive care unit (ICU), and mortality. Results: The subjects were 217 patients with a mean age of 44 years and included 134 male patients(61.8%). The injured group included 38 patients(16.9%). Traffic accidents were the most common mechanism of injury, and lateral compression was the most common type of fracture in all groups. The initial blood pressure was lower in the injured group, and the ISS was greater. The arterial pH was lower in the injured group, and shock within 24 hours after arrival at the emergency department was more frequent in the injured group. The amount of the transfused packed red blood cells within 24 hours was higher in the injured group than the non-injured group. Invasive treatment, including surgery and angiographic embolization, was more common in the injured group, and the stay in the ICU was longer in the injured group. Conclusion: A need exists to decide on a diagnostic and therapeutic plan regarding the possibility of intra-abdominal solid organ injury for hemodynamically unstable patients with unstable pelvic bone fractures and multiple associated injuries.

THE PHYSCIAL PORPERTIES OFY Y2O3-CONTAINING GLASS INFILTRATED ALUMINA CORE MADE BY PRESSURELESS POWDER PACKING METHOD (무가압 분말충전 알루미나에 이트리아를 함유한 붕규산염 유리를 침투시킨 코아 도재의 물성)

  • Whang, Seung-Woo;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.1
    • /
    • pp.221-243
    • /
    • 1997
  • The objective of this study was to characterize the mechanical properties of $Y_{2}O_{3}$-containing glass infiltrated ceramic core material, which was made by pressureless powder packing method. A pure alumina powder with a grain size of about $4{\mu}m$ was packed without pressure is silicon mold to form a bar shaped sample, and applied PVA solution as a binder. Samples were sinterd at $1350^{\circ}C$ for 1 hour. After cooling, $Y_{2}O_{3}$-containing glass($SiO_{2},\;Y_{2}O_{3},\;B_{2}O_{3},\;Al_{2}O_{3}$, ect) was infiltrated to the sinterd samples at $1300^{\circ}C$ for 2 hours and cooled. Six different proportions $Y_{2}O_{3}$ of were used to know the effect of the mismatch of the thermal expansion coefficient between alumina powder and glass. The samples were ground to $3{\times}3{\times}30$ mm size and polished with $1{\mu}m$ diamond paste. Flexural strength, fracture toughness, hardness and other physical properties were obtained, and the fractured surface was examined with SEM and EPMA. Ten samples of each group were tested and compared with In-Ceram(tm) core materials of same size made in dental laboratory. The results were as follows : 1. The flexural strengths of group 1 and 3 were significantly not different with that of In-Ceram, but other experimental groups were lower than In-Ceram. 2. The shrinkage rate of samples was 0.42% after first firing, and 0.45% after glass infiltration. Total shrinkage rate was 0.87%. 3. After first firing, porosity rate of experimental groups was 50%, compared with 22.25% of In-Ceram. After glass infiltration, porosity rate of experimental groups was 2%, and 1% in In-Ceram. 4. There was no statistical difference in hardness between two materials tested, but in fracture toughness, group 2 and 3 were higher than In-Ceram. 5. The thermal expansion coefficients of experimental groups were varied to $4.51-5.35{\times}10^{-6}/^{\circ}C$ according to glass composition, also the flexural strengths of samples were varied. 6. In a view of SEM, many microparticles about $0.5{\mu}m$ diameter and $4{\mu}m$ diameter were observed in In-Ceram. But in experimental group, the size of most particles was about $4{\mu}m$, and a little microparticles was observed. The results obtained in this study showed that the mismatch of the thermal expansion coefficients between alumina powder and infiltrated glass affect the flexural strength of alumin/glass composite. The $Y_{2}O_{3}$-containing glass infiltrated ceramic core made by powder packing method will takes less time and cost with sufficient flexural strength similar to all ceramic crown made with slip casting technique.

  • PDF

Effect of HAZ Softening Zone on Creep Rupture Properties of 1.0Cr-1.0Mo-0.25V Turbine Rotor Steels - Part I : Creep Rupture Life- (1.0Cr-1.0Mo-0.25V 터어빈 로터강의 열영향부 연화층이 크립 파단 특성에 미치는 영향 -Part I : 크립 파단 수명 -)

  • ;Indacochea, J. E.
    • Journal of Welding and Joining
    • /
    • v.15 no.1
    • /
    • pp.92-100
    • /
    • 1997
  • Weld repair of ASTM A-470 class 8 high pressure (HP) steam turbine rotor steel has been performed to extend the service life of older fossil units. Microhardness measurements were conducted across the weldment from unaffected base metal (BM) to weld metal (WM). The hardness of the BM was VHN 253, however it dropped up to VHN 227 at the heat affected zone (HAZ) close to unaffected BM for multipass SAW. This area of hardness drop is called "siftening zone" and has a width of 0.5-0.6mm. During creep rupture test, failure occurred around the softening zone and rupture time was 772.4hr at 19Ksi (132 Mpa) and 593.deg. C. Multipass MIG and TIG welding have been employed to reduce the softening zone width. The softening zone width for MIG was 0.3-0.4mm and for TIG was zero-0.4mm depending on heat inputs. However creep rupture time was decreased as softening zone width reduced. Creep rupture time also showed a close relationship with heat inputs in TIG process. The higher heat input, the longer rupture time. Most failure occurred at intercritical HAZ (ICHAZ), however rupture location was shifted to coarse grained HAZ (CGHAZ) as heat input decreased. The rupture surface showed tearing and dimple which indicated transgranular fracture. fracture.

  • PDF