Fouling of Ion Exchange Membranes and Their Fouling Mitigation (이온교환막의 막오염 및 오염저감)

  • 문승현;이홍주
    • Membrane Journal
    • /
    • v.12 no.2
    • /
    • pp.55-66
    • /
    • 2002
  • fouling phenomena of ion exchange membranes were reviewed for improved design and operation of electodialysis. The membrane fouling index for electrodialysis (EDMFI) was defined for the quantitative analysis of fouling potential as an analogy to the pressure-driven membrane process. fouling phenomena were compared in the electrodialysis experiments with inorganic foulant (silica sol) and organic foulants (humate and bovine serum albumin (BSA)), and their fouling potentials were analyzed using the fouling index. The comparison showed that the EDMFI could be used as a quantitative measure of the fouling tendency in electrodialysis processes. As a novel fouling mitigation method, square wave power was reported to be effective in electrodialysis with organic foulants. The square wave powers having the pulsed electric field enabled to reduce the membrane fouling significantly at an optimal frequency.

Identification of Fouling Phenomena and Establishment for Optimized Removal Process of Alginic Acid Sodium Salt Through Capacitive Deionization (CDI 공정에서 Alginic Acid Sodium Salt의 파울링 현상 확인 및 제거 조건 확립)

  • Lee, Jin Yeon;Rhim, Ji Won
    • Membrane Journal
    • /
    • v.30 no.5
    • /
    • pp.342-349
    • /
    • 2020
  • In this study, we suggest conditions to reduce fouling in capacitive deionization (CDI) caused by alginic acid sodium salt, one of the most common fouling-causing substances in natural water and wastewater management. First, NaCl is used as feed material, which is selected as the control of the experiment. As expected, fouling phenomena is not observed from NaCl. On the other hand, when alginic acid sodium salt is added to the inlet, the fouling phenomena can be observed. In order to minimize the fouling phenomena, the feed concentration of alginic acid sodium salt, applied potential during desorption process, and duration of applied potential to our CDI cell are controlled. With 7 mg/L of feed stream concentration, CDI performed using 1.2 V for 1 min during adsorption followed by desorption with -2 V for 1 min exhibited the highest alginic acid salt removal efficiency reaching 50.07%.

Investigation of Corrosion Fatigue Phenomena in Transient Zone and Preventive Coating and Blade Design against Fouling and Corrosive Environment for Mechanical Drive Turbines

  • Hata, Satoshi;Nagai, Naoyuki;Yasui, Toyoaki;Tsukamoto, Hiroshi
    • International Journal of Fluid Machinery and Systems
    • /
    • v.1 no.1
    • /
    • pp.121-139
    • /
    • 2008
  • For mechanical drive steam turbines, the investigation results of corrosion fatigue phenomena in the transient zone are introduced, including basic phenomena on expansion line and actual design and damage experience. These results were analyzed from the standpoint of stress intensity during the start of cracking. In order to resolve such problems, preventive coating and blade design methods against fouling and corrosive environments are developed. Detailed evaluation test results are given for coating performance using a unique test procedure simulating fouling phenomena and washing conditions. Finally, the results of the successful modification of internals and on-line washing results on site are introduced.

Predictions of Fouling Phenomena in the Axial Compressor of Gas Turbine Using an Analytic Method (해석적 방법을 이용한 가스터빈 축류 압축기의 파울링 현상 해석)

  • Song, Tae-Won;Kim, Dong-Seop;Kim, Jae-Hwan;Son, Jeong-Rak;No, Seung-Tak
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.12
    • /
    • pp.1721-1729
    • /
    • 2001
  • The performance of gas turbines is decreased as their operating hours increase. Fouling in the axial compressor is one of main reasons for the performance degradation of gas turbine. Airborne particles entering with air at the inlet into compressor adhere to the blade surface and result in the change of the blade shape, which is closely and sensitively related to the compressor performance. It is difficult to exactly analyze the mechanism of the compressor fouling because the growing process of the fouling is very slow and the dimension of the fouled depth on the blade surface is very small compared with blade dimensions. In this study, an improved analytic method to predict the motion of particles in compressor cascades and their deposition onto blade is proposed. Simulations using proposed method and their comparison with field data demonstrate the feasibility of the model. It if found that some important parameters such as chord length, solidity and number of stages, which represent the characteristics of compressor geometry, are closely related to the fouling phenomena. And, the particle sloe and patterns of their distributions are also Important factors to predict the fouling phenomena in the axial compressor of the gas turbine.

Performance degradation due to compressor fouling of an industrial gas turbine operating at design point condition (막오염에 의한 압축기 성능 저하가 발전용 가스터빈 설계점 성능에 미치는 영향에 관한 연구)

  • Seo, J.S.;Sohn, J.L.;Kim, J.H.;Kim, T.S.;Ro, S.T.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.6 no.3 s.20
    • /
    • pp.36-43
    • /
    • 2003
  • Operating performance of industrial gas turbines in combined cycle power plants depends upon atmospheric conditions. Compressor fouling caused by airborne particles in the atmosphere and their adhesions on compressor blades is one of critical phenomena related to the performance degradation of industrial gas turbines. Compressor fouling provokes increase of pressure loss in inlet duct, decrease of mass flow rate of intake air and decrease of compressor stage efficiency. In this study, impacts of compressor fouling on the performance of an industrial gas turbine operating at design point condition are investigated analytically. As results, it is found that the reduction of produced power with decreased mass flow rate of intake air caused by narrowed flow area by the adhesion of airborne particles on compressor blades is the most dominant impact on the gas turbine performance by the compressor fouling phenomena.

Confirmation of The Fouling Phenomena in CDI Process and The Establishment of Its Removal Process Conditions (CDI 전극 내 파울링 현상 확인 및 제거공정 조건의 확립)

  • Kim, Tae Yeong;Rhim, Ji Won
    • Membrane Journal
    • /
    • v.29 no.5
    • /
    • pp.276-283
    • /
    • 2019
  • In this study, The experiments of the confirmation of the fouling phenomena in CDI process and the establishment of its removal process conditions were carried out. The foulant concentrations of humic acid sodium salt (HA) added to the feed solution were 5, 10, 15 mg/L, respectively. The occurrence of fouling under the certain adsorption/desorption conditions could be confirmed with an increase in adsorption and desorption concentration curve over time. Both the voltage and time in adsorption and desorption processes were changed to eliminate the fouled pollutants. Typically, the fouling removal condition was found at the adsorption condition 1.2 V/5 min and the desorption condition -3 V/2 min, respectively.

A Study on Fouling Phenomena of in Petroleum Chemical Process (석유화학공정내에서 원유의 파울링 현상에 관한 연구)

  • Lee, Dong Rak;Ryu, Sang Ryoun;Park, Sang Jin;Cho, Wook Sang;Kim, Sang Wook
    • Applied Chemistry for Engineering
    • /
    • v.7 no.3
    • /
    • pp.443-452
    • /
    • 1996
  • Fouling is caused by sedimentation and corrosion of polymer, heavy paraffine, chemicals, heavy organics, asphaltene, etc. in the entire chemical process of heat exchanger, boiler, desalter, etc. Fouling phenomena remains a serious operating problem which results in increased energy consumption, increased pressure drops, reduction or complete loss of products yield, and increased maintenance costs. In order to calculate the separated amounts of foulants and to control the fouling process, the predictive model is developed which is based on Scott & Magat polymer solution theory, Peng-Robinson EOS, BWR EOS, and continuous and multicomponent thermodynamics.

  • PDF

A Comparative Study on the Fouling Characteristics of River and Tap Water in a Heat Exchanging Model (열교환기 모델내 하천수와 시수의 Fouling 특성 비교)

  • Sung, Sun-Kyung;Suh, Sang-Ho;Roh, Hyung-Woon
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.49-54
    • /
    • 2003
  • Scale is formed when hard water is heated or cooled in heat transfer equipments such as heat exchangers, condensers, evaporators, cooling towers, boilers, and pipe walls. When scale deposits in a heat exchanging surface, it is traditionally called fouling. The objective of the present study was to compare the fouling characteristics of river and tap water in a heat exchanging model. FromtheSEM analyses for tap water the $calciteformofCaCO3_{3}$ was formed. For river water, however, the $aragoniteCaCO_{3}$ wasformed.In order to investigate velocity effects on the fouling characteristics in the heat exchanging model, the inlet velocity was varied with 0.5, 1.0 and 1.5 m/s, respectively. The fouling characteristics of river water were quite different from those of tap water. For the case of the 'velocity of 1.5m/s', the overall heat transfer coefficient was reduced up to 26% than that of the 'velocity of 0.5m/s'

  • PDF

Review of Basics Reverse Osmosis Process Modeling: A New Combined Fouling Index Proposed (역삼투 공정을 위한 모델링 총설 및 새로운 복합적 막오염도의 제안)

  • Kim, Albert S.
    • Membrane Journal
    • /
    • v.27 no.4
    • /
    • pp.291-312
    • /
    • 2017
  • Seawater desalination is currently considered to be one of the primary technologies to resolve the global water scarcity problem. A basic understanding of membrane filtration phenomena is significant not only for further technological development but also for integrated design, optimal control, and long-term maintenance. In this vein, the present work reviews the major transport and filtration models, specifically related to reverse osmosis phenomena, provides theoretical insights based on statistical mechanics, and discusses model-based physical meanings as related to their practical implications.

NOM fouling and Removal of Micro-pollutants in RO and NF Membrane processes (RO 및 NF막에서의 부식질에 의한 Fouling 및 미량오염물질의 제거)

  • Wang, Chang-Keun;Cha, Joon-Chul;Lee, Yong-Hyun;Kim, Su-Dong;Liu, Ju-Whan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.1
    • /
    • pp.73-80
    • /
    • 2004
  • This study investigated the phenomena of membrane fouling by NOM and the effect of the fouling on removal of micro-pollutants. NOM has a great effect on decline of permeate flux. Permeate flow rate was reduced by 88% in RO and 34.8% in NF for 323hr operation period. Removal rate of $UV_{254}$, is 87.4% in RO and 78.5% in NF and removal rate of DOC is 42.7% in RO and 32.9% in NF for 2mg/l humic acid. Removal efficiency of the micro-pollutants by the RO and NF membranes fouled by humic acid was mostly lower than that by the new membrane. The concentration polarization which affects the flux and the rejection was thought to occur in the active layer of the membrane, as the membrane was getting fouled.