• 제목/요약/키워드: form defect

검색결과 310건 처리시간 0.025초

Tetralogy of Fallot with Subarterial Ventricular Septal Defect

  • Kim, Sam-Hyun;Seo, Dong-Man;Park, Pyo-Won;Song, Meong-Gun;Park, Young-Kwan;Lee, Young-Kyoon
    • Journal of Chest Surgery
    • /
    • 제21권1호
    • /
    • pp.82-86
    • /
    • 1988
  • Tetralogy of Fallot with subarterial ventricular septal defect is known to be relatively common in the Far East. Among the 140 consecutive patients who underwent repair for tetralogy, 15 [10,7@] had this variant form of tetralogy. Though the degree of pulmonic stenosis seems only mild or moderately severe because of the absence of infundibular septum and relatively large size of pulmonary arteries in this type of tetralogy, it has a special surgical implication that a patch widening of the right ventriculotomy is necessary in every case to avoid the postoperative subpulmonic stenosis. A morphological and surgical features of tetralogy with subarterial VSD are presented.

  • PDF

국내 품질경영 및 공산품 안전표지 표준화 대상 연구 (Standardization of Quality Management and Product Safety Sign in Korea)

  • 이익성
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제15권3호
    • /
    • pp.176-180
    • /
    • 2015
  • A defect on the product safety display is defined by a failure to prevent the damage caused by the inappropriate explanation, direction, and caution to warn the users of the related risks. In other words, it lacks the sufficient instructions or caution for proper use and is unable to furnish the possible danger of the product and the instructions to deal with it. The defect is the responsibility of the manufacturers who are supposed to provide the adequate information so as to prevent injuries of the users. However, in order to prove the product safety display defective, there should be a comprehensive consideration in many different ways such as social norms (such as property and expectation of the product), usage form, indication of the expected risk, and awareness of consumer about the harm and possibility of avoidance of danger. The purpose of this research is to propose the content and types of standardized indication of safety in the industrial product by collecting and analyzing domestic safety information.

Speckle Defect by Dark Leakage Current in Nitride Stringer at the Edge of Shallow Trench Isolation for CMOS Image Sensors

  • Jeong, Woo-Yang;Yi, Keun-Man
    • Transactions on Electrical and Electronic Materials
    • /
    • 제10권6호
    • /
    • pp.189-192
    • /
    • 2009
  • The leakage current in a CMOS image sensor (CIS) can have various origins. Leakage current investigations have focused on such things as cobalt-salicide, source and drain scheme, and shallow trench isolation (STI) profile. However, there have been few papers examining the effects on leakage current of nitride stringers that are formed by gate sidewall etching. So this study reports the results of a series of experiments on the effects of a nitride stringer on real display images. Different step heights were fabricated during a STI chemical mechanical polishing process to form different nitride stringer sizes, arsenic and boron were implanted in each fabricated photodiode, and the doping density profiles were analyzed. Electrons that moved onto the silicon surface caused the dark leakage current, which in turn brought up the speckle defect on the display image in the CIS.

분층피부와 분말골로 이식 전 처리된 유리견갑골근피판과 임플란트 보철을 이용한 경구개와 상악골의 기능적 재건 (FUNCTIONAL RECONSTRUCTION OF DENTO-PALATAL AND MAXILLARY DEFECT USING STAGED OPERATION OF PREFABRICATED SCAPULAR FREE FLAP AND DENTAL IMPLANTS)

  • 이종호;김명진;박종철;김영수;안강민;팽준영;김성민;명훈;황순정;서병무;최진영;정필훈
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제30권4호
    • /
    • pp.301-307
    • /
    • 2004
  • The flap considered at first for the reconstruction of large maxillary defect, especially mid-face defect, is scapular free flap, because it provides ample composite tissue which can be designed 3-dimensionally for orbital, facial and oral reconstruction. In case of maxillary defect involving hard palate, however, this flap has some limitations. First, its bulk prevents oral function and physio-anatomic reconstruction of nasal and oral cavity. Second, mobility and thickness of cutaneous paddle covering the alveolar area reduce retention of tissue-supported denture and give rise to peri-implantitis when implant is installed. Third, lateral border of scapula that is to reconstruct maxillary arch and hold implants is straight, not U-shaped maxillary arch form. To overcome these problems, new concept of step prefabrication technique was provided to a 27-year-old male patient who had been suffering from a complete hard palate and maxillary alveolar ridge defect. In the first stage, scapular osteomuscular flap was elevated, tailored to fit the maxillary defect, particulated autologous bone was placed subperiosteally to simulate U-shaped alveolar process, and then wrapped up with split thickness skin graft(STSG, 0.3mm thickness). Two months later, thus prefabricated new flap was elevated and microtransferred to the palato-maxillary defect. After 6 months, 10 implant fixtures were installed along the reconstructed maxillary alveolus, with following final prosthetic rehabilitation. The procedure was very successful and patient is enjoying normal rigid diet and speech.

백서 두개골 부분결손시 골막 유무에 의한 골치유 양상에 관한 연구 (THE STUDY OF BONE HEALING ON PARTIAL DEFECT OF CALVARIAL BONE WITH OR WITHOUT PERIOSTEUM IN RAT)

  • 송영완;조병욱;심정원
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제18권4호
    • /
    • pp.746-757
    • /
    • 1996
  • Bony defects may be found as a result of congenital anomalies, traumatic injury, automobile collisions and industrial accidents in the maxillofacial area. Such conditions are often associated with severs functional and esthetic problem. Various surgical procedure has been utilized in attempts to repair and reconstruct bony defects. Bone is a complex, living, constantly changing tissue. The architecture and composition of cancellous and cortical bone allow the skeleton to perform its essential mechanical functions. Periosteum covers the external surface of bone and consists of two layers : an outer fibrous layer and an inner more cellular and vascular layer. The inner osteogenic layer or cambium layer can form new bone while the outer layer firms part of the insertions of tendons, ligaments and muscles. This study was under taken to evaluate bone healing process on partial defect of calvarial bone with or without periosteum in rat. We made calvarial defects of different size(4mm, 6mm, 8mm) with periosteum or without periosteum in rat to study the effect of defect size on healing process. Control and experimental groups sacrified at 1, 2, 4, 6, 8 weeks, postoperatively. We examed the specimens by gloss findings, light microscophy, and fluorescent microscophy. The results were as follows. 1. Gloss findings: Control groups are larger bony defects than experimental groups after 2 weeks, and than control groups advanced healing of defected bone but experimental groups are lesser after 4, 6 weeks. After 8 weeks, bone defect has not been identified in control and experimental groups. 2. Light microscope: All defects of control groups are larger bony defects than experimental groups after 2 weeks. And than control groups show smaller defect after 4 weeks. After 8 weeks, the control group reveal pin-point sized, hardly identifiable defect space and the experimental group reveal small, but definite defect space. 3. Fluorescent microscope : Each week, new bone formation of control group is very similar to the experimental group. In this study, Osteogenesis of calvarial bone defects with periosteum or without periosteum was examined for 8 weeks in rats. The replaced periosteum had batter new bone formation than the removed periosteum.

  • PDF

Growth and Osteoblastic Differentiation of Mesenchymal Stem Cells on Silk Scaffolds

  • Cho, Hee-Yeon;Baik, Young-Ae;Jeon, Suyeon;Kwak, Yoon-Hae;Kweon, Hae Yong;Jo, You Young;Lee, Kwang Gill;Park, Young Hwan;Kang, Dongchul
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • 제27권2호
    • /
    • pp.303-311
    • /
    • 2013
  • In this study, we compared the efficiency of osteoblast differentiation media (ODM) containing three distinct reagent combinations in osteoblastic differentiation of human bone marrow-derived mesenchymal stem cells (hBMSCs) in monolayer culture. In addition, we analyzed growth and differentiation of hBMSCs on silk scaffolds and examined the bone-forming activity of a nanofibrous silk scaffold in a tibia diaphysis defect model of a rat hind limb with intramedullary nailing. Although all three ODM increased alkaline phosphatase activity to a comparable extent, the ODM containing bone morphogenetic protein-2 (BMP-2) was found to be significantly less effective in promoting mineral deposition than the others. Growth of hBMSCs on sponge-form silk scaffolds was faster than on nanofibrous ones, while osteoblastic differentiation was apparent in the cells grown on either type of scaffold. By contrast, bone formation was observed only at the edge of the nanofibrous scaffold implanted in the tibia diaphysis defect, suggesting that use of the silk scaffold alone is not sufficient for the reconstitution of the long bone defect. Since silk scaffolds can support cell growth and differentiation in vitro, loading MSCs on scaffolds might be necessary to improve the bone-forming activity of the scaffold in the long bone defect model.

음향방출에 의한 평면결함의 위치표정 기술 (AE Source Location Techniques in Planar Defects)

  • 우창기;이장규;박성완;김봉각;윤종의;인승현
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 춘계학술대회 논문집
    • /
    • pp.369-375
    • /
    • 2002
  • The results of source location in terms of AE signal occurred by the spot exciting as suggested in this research, it has been confirmed that AE technique is quite fruitful in figuring out the location of the occurrence, form, size and direction of the defects. Thus, it is expected that the application of the experimental method suggested in this study would make it possible to identify, in the nondestructive way, the location of the defect in the material.

  • PDF

웨이브렛변환을 이용한 기어결함의 진단 (The Detection of Gear failures Using Wavelet Transform)

  • Park Sung-Tae;Gim Jae-Woong
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.363.1-363
    • /
    • 2002
  • This paper presents that the Wavelet Transform can be used to detect the various local defects in a gearbox. Two types of defects which are broken tooth and localized wear, are experimented and the signals are collected by accerometer and acoustic sensors and analyized. Because of the complecity of the signals acquired form sensors, it is needed to identify the interesting signal. (omitted)

  • PDF

다개체군 유전자 알고리즘의 집단간 이주 기법 (The Migration Scheme between Groups in the Multi-population Genetic Algorithms)

  • 차성민;권기호
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 추계종합학술대회 논문집(3)
    • /
    • pp.9-12
    • /
    • 2000
  • Genetic algorithm is a searching method which based on the law of the survival of the fittest. Multi-population Genetic Algorithm is a modified form of Genetic Algorithm, which was devised for covering the defect of general genetic algorithm. The core of multi-population genetic algorithm is said to be the migration schemes. The fitness-based migration scheme and the random migration scheme are currently used. In this paper, a new migration scheme, ‘the migration scheme between groups’, is suggested, and compared to the general two migration schemes.

  • PDF

Thermoelectric Imaging of Epitaxial Graphene

  • 조상희
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.113.2-113.2
    • /
    • 2014
  • Heat is a familiar form of energy transported from a hot side to a colder side of an object, but not a notion associated with microscopic measurements of electronic properties. A temperature difference within a material causes charge carriers, electrons or holes, to diffuse along the temperature gradient inducing a thermoelectric voltage. Here we show that local thermoelectric measurements can yield high sensitivity imaging of structural disorder on the atomic and nanometre scales. Using this imaging technique, we discovered a defect-mediated dimensional evolution of strain-response patterns in epitaxial graphene with increasing thickness.

  • PDF