• Title/Summary/Keyword: forearm skin

Search Result 165, Processing Time 0.023 seconds

Factors influencing the bio-impedance data in tissue segments along the three arm meridians: a pilot study

  • Lim, Chi Eung Danforn;Wong, Felix Wu Shun;Smith, Warren
    • CELLMED
    • /
    • v.1 no.1
    • /
    • pp.7.1-7.9
    • /
    • 2011
  • Bioelectric impedance measurements have been reported to show significant variation between individuals. Different physiological conditions like thickened skin, obesity, and fluid retention can affect the impedance measurement. Therefore, it is important to learn what other factors can affect the measurements of impedance even in healthy individuals. Such information is a prerequisite for understanding the changes in impedance associated with acupuncture treatment. This study investigated the bio-impedance properties of tissue segments in the arms of a number of healthy subjects, so as to define the factors that might influence the variation of the bio-impedance data in acupuncture meridians studies. 51 healthy subjects were recruited through Liverpool Hospital, Sydney. Demographic data was collected from each subject including the age, sex, BMI, and time since most recent meal. Electrodes were applied to the forearms of each test subject. Measurements were done by a purpose-built Bio-Impedance Research Device (BIRD-I) which allowed the determination of core resistance (Rc) and core reactance (Xc) of each of the three meridian tissue segments on the anterior surface of the forearm. No significant difference was found in the core resistance attributable to age group, gender, BMI or meal intake. However, a statistically significant trend in increasing resistance from the radial to ulnar aspect of the forearm (p < 0.001) was found. No significant difference was found in the core resistance of test tissue segments among the 51 healthy subjects measured in this study. However, the trend of increasing core resistance from the radial to ulnar aspects of the arm deserves further investigation.

Use of the Tenocutaneous Free Flap In Hand Reconstruction (유리 건 피판을 이용한 수부 재건술)

  • Chung, Duke-Whan;Han, Chung-Soo;Kim, Ki-Bong;Yi, Jin-Woong
    • Archives of Reconstructive Microsurgery
    • /
    • v.10 no.2
    • /
    • pp.93-98
    • /
    • 2001
  • Purpose : This describes our experience with a tenocutaneous free flap from the dorsum of the foot or radial forearm to reconstruct the dorsal skin and extensor tendons of the hand. Material and Methods : Between february 1987 and July 1998, we treated 9 patients with composite tissue loss on the dorsal hand caused by crushing injury. Nine men had an average age of 26.4 years(range, $19{\sim}47$). We treated 5 patients with the free dorsalis pedis flap including the extensor tendons and the superficial peroneal nerve and 4 patients with reverse forearm flap including the brachioradialis tendon and/or superficial radial nerve. Flap size was average 4.4(3,2cm. Evaluation of the results was based on the survived flap rate, the recovery rates for range of motion of the metacarpophalageal joints in the operated fingers. two-point discrimination. Results : All flaps were well vascularized and survived completely. Recovery rates for range of motion of the metacarpophalageal joints in operated fingers range from $78%{\sim}99%$(average, 90%). Two-point discrimination of the transferred flaps in 5 patients average $20{\pm}3.5mm$. Conclusion : The advantages of this procedure are mass action reconstruction with tendon, one-stage operation, faster healing with less adhesion formation, and early mobilization.

  • PDF

Soft Tissue Reconstruction of Finger and Hand Using Arterialized Venous Free Flap (동맥화 정맥 유리 피판술을 이용한 수부와 수지 연부조직 결손의 재건)

  • Kong, Byeong-Seon;Kim, Yong-Jin;Cho, Kwang-Woo
    • Archives of Reconstructive Microsurgery
    • /
    • v.13 no.2
    • /
    • pp.107-116
    • /
    • 2004
  • Flaps are necessary, when important structures such as bone, tendon, nerve and vessel are exposed. Arterialized venous free flap is suited to the coverage of finger and hand because the thickness of venous flap is thin. Authors performed 65 cases arterialized venous free flap for the soft tissue reconstruction of the hand and finger. The size of donor defect were from $1{\times}1cm\;to\;7{\times}12cm$. The mean flap area was $9.1cm^2$. The recipient sites were finger tip in 34 cases, finger shaft in 29 cases and hand in 2 cases. The donor sites were volar aspect of distal forearm in 40 cases, thenar area in 17 cases and foot dorsum in 6 cases. The types of arterialized venous free flap were A-A type in 4 cases and A-V type in 61 cases. The length of afferent vein was from 0.5 cm to 3 cm (mean 1.7 cm) and efferent vein was from 1 cm to 10 cm (mean 2.2 cm). 58 flaps(89.2%) survived eventually. 42 flaps(64.6%) survived totally without any complication. 8 flaps(12.3%) showed the partial necrosis but they were healed without any additional operations. 8 flaps (12.3%) showed the partial necrosis requiring the additional skin graft. We had a satisfactory result by using arterialized venous free flap for the soft tissue reconstruction of finger and hand. We believe that volar aspect of distal forearm, thenar area, foot dorsum are suited as a donor site and the short length of the flap pedicle, the strong arterail inflow affect the survival rate of arterialized venous free flaps.

  • PDF

Reconstruction of the Extremities with Lateral Arm Free Flap (외측 상완 유리 판을 이용한 사지 재건술)

  • Lee, Jun-Mo;Lee, Ju-Hong;Kim, Hak-Ji
    • Archives of Reconstructive Microsurgery
    • /
    • v.13 no.1
    • /
    • pp.51-57
    • /
    • 2004
  • Introduction: To cover the exposed tendons and bones in the foot and hand which need coverage and abundant vascular flow, lateral arm flaps were transferred. Lateral arm flap is a thin and innervated fasciocutaneous flap with a lower lateral cutaneous nerve and posterior radial collateral artery. Materials and methods: From October 1992 through September 2003, we have performed 5 lateral arm flaps for reconstruction of the exposed achilles tendons in 2 cases and the exposed forearm extensors, 2nd to 5th metacarpal bones and scaphoid each 1 case. The causes were traffic accident in 2 cases and machinary injury in 3 cases. Age range was between 31 to 74 (average 50) and all male except 1. Posterior lateral collateral artery and venae comitantes were anastomosed by end to end in 3 cases and vena comitante in 2 cases. Lower lateral cutaneous nerve was anastomosed with a branch of superficial radial nerve in 2 cases. Results: The results were evaluated by survival of the flap, sensory discrimination, cosmesis and comfort in the activities of the daily living. All flaps were survived. Sensory recovery was graded as deep cutaneous pain sensibility in 2 cases. Cosmesis was moderately satisfied and comfort was good except 1 as moderate. Postoperative defatting procedure was done in 1 case and skin abrasion was occurred in 1 case. Conclusion: Lateral arm flap was suitable for coverage of the exposed achilles tendons and exposed forearm extensors, metacarpals and scaphoid in the wrist.

  • PDF

Stratum Corneum Exfoliation Effect with Hydroxy Acid according pH (pH에 따른 하이드록시 산(Hydroxy Acid)의 각질 박리 효과 연구)

  • Nam, Gaewon
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.42 no.4
    • /
    • pp.413-420
    • /
    • 2016
  • Hydroxy acid has been used to enhance anti-aging and skin moisturization by peeling effect on the skin stratum corneum, and thus it has been widely used in topical products and cosmetic products. Among them, the effect that appears most effectively in a short period of time has been reported to be effected by the pH of the cosmetic formulations. However, there are many difficulties in use due to irritation caused by pH and concerns about side effects. The purpose of this study was to evaluate the effect of applying cosmetics with (1) varying concentrations, (2) types and (3) pH of hydroxy acid on human skin. 22 healthy adults were stained with DHA (dihydroxyacetone) and DC (dansyl chloride) on the forearm, and the skin exfoliation effect was measured after application of the test products. (1) The application of GA (glycolic acid) increased the desquamation by concentration dependent. (2) the test product prepared with neutral pH showed no exfoliation effect. In contrast, SA (salicylic acid) showed a statistically significant exfoliation effect at both acidic pH and neutral pH. (3) The neutral pH SA showed excellent exfoliation effect on bot DHA and DC stained stratum corneum. These results suggest that it is possible to manufacture safe cosmetics without damaging the skin barrier, providing an opportunity to use cosmetics that are expected to exfoliate to people, whose skin is sensitive to pH.

The Efficacy of Cleansing Device with a Rotating Brush on the Skin (회전 브러시를 이용한 클렌징 기기의 효과)

  • Yeo, In Kwon;Suk, Jang Mi;Jung, Sang Wook;Park, Jin Oh;Kim, Eun Joo;Nam, Gae Won;Yoo, Kwang Ho;Kim, Beom Joon;Kim, Myeung Nam
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.39 no.2
    • /
    • pp.97-103
    • /
    • 2013
  • Recently, the importance of cleansing is emphasized according to increasing use of cosmetics. Even though many cleansing devices with a rotating brush are commercially available, there are no reports about cleansing devices with rotating brushes in Korean literature. In the present study, we evaluated the efficacy of cleansing device with a rotating brush which was named PBRCF1201 (Amorepacific Co., Korea). 20 volunteers were enrolled in this study. Before and after use of PBRCF1201, we measured the number of black head, skin brightness, desquamation index, sebum, and the number of pores on the face and forearm. Cleansing by cleansing device with a rotating brush was shown to cleanse better than manual cleansing. In addition, the number of black heads, skin brightness, desquamation index, sebum and the number of pore were also improved after cleansing. Therefore, the cleansing device with a rotating brush appears to be an effective cleansing method without causing injury or dryness.

Alteration in Infrared Thermal Imaging by Use of Acupuncture-like Electric Stimulation on Finger Control Gate (체열촬영으로 관찰한 전기수지자극의 효과)

  • Lee, Sang-Hun;Lee, Kyu-Chang;Woo, Nam-Sik;Lee, Ye-Chul;Kim, Sun-Bok;Lee, Hyung-Hoan
    • The Korean Journal of Pain
    • /
    • v.7 no.2
    • /
    • pp.222-230
    • /
    • 1994
  • Acupuncture-like transcutaneous electrical nerve stimulation(ALTENS) on acupuncture site(dorsal and ventral side of finger) were compared with a placebo site(forearm) by infrared thermal imaging. Six disease-free volunteers underwent, on different days, an ALTENS treatment and a placebo treatment in a cross-over sequences of stimulation control and inhibition control in excess of 50 treatments. ALTENS treatments were given at 30Hz at an intensity just below pain threshold delivered to acupuncture points on fingers. Placebo stimulations were administered in similar manner. After every thirty minutes of ALTENS and placebo treatment with stimulation, inhibition control sequence and vice versa, we examined whole body infrared thermal imaging and checked changed skin temperature on frontal, anterior chest, upper and lower abdomen, dorsal and ventral aspect of hand, thoracic and lumbar area, anterior and posterior aspect of lower leg. There were significant skin temperature elevations with ALTENS treatment, especially finger control gate corresponding organ area. Placebo treatment revealed no skin temperature change. We concluded that ALTENS on finger control gate influence physiologic state as opposed to conventional electric stimulation.

  • PDF

How Skin Care Ingredient Concentrations Can Modulate the Effect of polyols and Oils on Skin Moisturization and Skin Surface Roughness (화장품 원료 중 폴리올, 오일 농도에 따른 피부 보습과 피부 표면 거칠기의 변화)

  • Nam, Gae-Won;Kim, Seung-Hun;Kim, Eun-Joo;Kim, Jin-Han;Chae, Byung-Guen;Lee, Hae-Kwang;Moon, Seong-Joon;Kang, Hak-Hee;Chang, Ih-Seop
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.31 no.4 s.54
    • /
    • pp.337-342
    • /
    • 2005
  • The aim of this study was to evaluate the influence of different skin care ingredient concentrations on the effect of polyols and oils on the human skin moisturization and skin surface roughness. Polyols and oils were essential ingredients to make a skin care formulation. But these were still not understood how much concentration(s) were tested on human skin in the aspect of efficacy and sensory. We studied to examine various concentrations of ingredient by cosmetic companies using noninvasive methods. Polyols were composed of glycerol and butylene glycol (BG) as 1:1 ratio, and oils were hydrogenated polydecene, cetyl ethylhexanoate and pentaerythrityl tetraethylhexanoate (PTO(R), Stearinerie Dubois Fils Co., France) as 1:1:1 ratio. All compounds were tested $0{\sim}27%dml$ Polyols and $0{\sim}35%dml$ oils in O/W emulsions. We investigated the effect of water contents and the effect of stratum corneum roughness in forearm skin after application of compounds. Water contents of the skin measured by skin capacitance and skin surface roughness measured visual scoring of skin surface biopsy through the scanning electron microscopy. Water contents of the skin were highly related to amount of polyols (to 20%) and oils (to 12%). Correlation coefficients were 0.971 and 0.985 respectively (p<0.01), 2 h after application. Skin surface roughness was positively correlated with polyol contents in concentration dependent manner, and depend on oils up to 6%. The ratio of coefficient was 2.5 to 1 (polyol to oils) by regression analysis. Further studies will be conducted with other ingredients such as surfactants, lipids and aqueous materials, and with ether methods for noninvasive measurement.

Clinical Cases Analysis of Forearm Free Fasciocutaneous Flaps on Oral Cavity Defect Area (구강 결손부에 적용된 요골 유리전완 피부피판 적용례 분석)

  • Kim, Uk-Kyu;Lee, Kwang-Ho;Song, Won-Wook;Hwang, Dae-Seok;Kim, Yong-Deok;Shin, Sang-Hun;Kim, Jong-Ryoul;Chung, In-Kyo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.4
    • /
    • pp.324-331
    • /
    • 2010
  • The radial forearm free flap (RFFF) has become a workhorse flap as a means of reconstructing surgical defects in the head and neck region. We have transferred 12 RFFFs with fasciocutaneous type on oral cavity defects in 12 patients after cancer resection and submucous fibrotic lesion ablation from 2005 to 2007 at Department of oral and maxillofacial surgery, Pusan National University Hospital. We reviewed retrospectively patients' charts and followed up the patients. Clinical analysis on the cases with RFFFs focusing on flap morbidity, indications and available vessels was done. The results of study are follows: 1. RFFF could be applied for all kind of defects after resection of tongue, floor of mouth, buccal mucosa, denuded bone of palate, maxilla, and mandible. 2. All free flaps could be used for primary reconstruction. The survival rate of 12 RFFFs was 92%. Partial marginal loss of the flaps was shown as 3 cases among 12 cases. Large size-vessels like superior thyroid artery, facial artery, internal jugular vein were favorable for microvascular anastomosis. 3. Parenteral nutrition instead of nasal L-tube also can be favorable for postoperative a week for better healing of the flap if the patients couldn't be tolerable with nasal tubing. 4. Donor sites with thigh skin graft were repaired with wrist band for 2 weeks. The complications included scarring, abnormal sensation on hand, and reduced grip strength in few patients, but those didn't induce major side effects. 5. Most RFFFs were well healed even if mortality rate of cancer patients was shown as 50% (5/10 persons). The mortality of patients was not correlated with morbidity of the flaps. We could identify the usefulness of RFFF for restoration of oral function, esthetics if the flap design, tissue transfer indications, and well controlled operation are proceeded.

Vacuum Assisted Auto-Lancing Technique for Capillary Blood Sampling on the Forearm with Minimized Pain (전완부위 최소통증 채혈을 위한 진공 자동 채혈기법)

  • Park Mi Sook;Park Kyung Soon;Kim Kyung Ah;Jun Myung Hee;Kim Tae Im;Lee Tae Soo;Cha Eun Jong
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.557-563
    • /
    • 2004
  • A new vacuum assisted auto-lancing technique is proposed to minimize pain. Specially designed lancing device was introduced, which applied -100mmHg right after skin puncture on the forearm. Sampled blood volumes were measured in 58 normal females. Mean volume of 464 samples was approximately 2.6$\muL$ and the frequency of more than 0.5$\muL$ was 86%. Thus the success rate of blood sugar test should also be the same when using modern glucose meters capable of testing with only 0.3~0.5$\muL$ of capillary blood. When pain scores were quantitatively evaluated by the visual pain measure, only 23% pain of the traditional finger sampling was experienced, demonstrating that capillary blood sampling was performed on the forearm with almost no pain. The present technique reduced pain to a great degree, though resampling might be unavoidable due to 14% of test failure rate estimated for modern glucose meters. However, minimized pain makes the present technique of great convenience for diabetic patients who need blood sampling a few times a day.