• Title/Summary/Keyword: forced degradation study

Search Result 19, Processing Time 0.026 seconds

Numerical analysis of the temperature distribution of the EM pump for the sodium thermo-hydraulic test loop of the GenIV PGSFR

  • Kwak, Jaesik;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • v.53 no.5
    • /
    • pp.1429-1435
    • /
    • 2021
  • The temperature distribution of an electromagnetic pump was analyzed with a flow rate of 1380 L/min and a pressure of 4 bar designed for the sodium thermo-hydraulic test in the Sodium Test Loop for Safety Simulation and Assessment-Phase 1 (STELLA-1). The electromagnetic pump was used for the circulation of the liquid sodium coolant in the Intermediate Heat Transport System (IHTS) of the Prototype Gen-IV Sodium-cooled Fast Reactor (PGSFR) with an electric power of 150 MWe. The temperature distribution of the components of the electromagnetic pump was numerically analyzed to prevent functional degradation in the high temperature environment during pump operation. The heat transfer was numerically calculated using ANSYS Fluent for prediction of the temperature distribution in the excited coils, the electromagnet core, and the liquid sodium flow channel of the electromagnetic pump. The temperature distribution of operating electromagnetic pump was compared with cooling of natural and forced air circulation. The temperature in the coil, the core and the flow gap in the two conditions, natural circulation and forced circulation, were compared. The electromagnetic pump with cooling of forced circulation had better efficiency than natural circulation even considering consumption of the input power for the air blower. Accordingly, this study judged that forced cooling is good for both maintenance and efficiency of the electromagnetic pump.

Experimental damage evaluation of prototype infill wall based on forced vibration test

  • Onat, Onur
    • Advances in concrete construction
    • /
    • v.8 no.2
    • /
    • pp.77-90
    • /
    • 2019
  • This paper aims to investigate vibration frequency decrease (vibration period elongation) of reinforced concrete (RC) structure with unreinforced infill wall and reinforced infill wall exposed to progressively increased artificial earthquake load on shaking table. For this purpose, two shaking table experiments were selected as a case study. Shaking table experiments were carried on 1:1 scaled prototype one bay one storey RC structure with infill walls. The purpose of this shaking table experiment sequence is to assess local behavior and progressive collapse mechanism. Frequency decrease and eigen-vector evolution are directly related to in-plane and out-of-plane bearing capacities of infill wall enclosure with reinforced concrete frame. Firstly, frequency decrease-damage relationship was evaluated on the base of experiment results. Then, frequency decrease and stiffness degradation were evaluated with applied Peak Ground Acceleration (PGA) by considering strength deterioration. Lastly, eigenvector evolution-local damage and eigenvector evolution-frequency decrease relationship was investigated. Five modes were considered while evaluating damage and frequency decrease of the tested specimens. The relationship between frequency decrease, stiffness degradation and damage level were presented while comparing with Unreinforced Brick Infill (URB) and Reinforced Infill wall with Bed Joint Reinforcement (BJR) on the base of natural vibration frequency.

Numerical Study of the Effect of Fan Arrangement on the Cooling Performance of the ONAF Type Radiator for Power Transformer (변압기용 ONAF 방식 방열기의 팬 배치에 따른 냉각특성 연구)

  • Kim, Kuk-Kyeom;Suh, Yong Kweon;Kang, Sangmo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.4
    • /
    • pp.449-455
    • /
    • 2015
  • Owing to the trend of an increase in capacity and high-efficiency requirement, the life and reliability of power transformer depend significantly on the amount of heat generation per unit volume and the degradation of insulation oil. These problems can be solved by enhancing the cooling performance of the radiator. The purpose of this study was to find a suitable position of fans for a better cooling effect given by the forced-convection of air in an ONAF (Oil Natural Air Forced) type transformer. In the simulation, commercial software was used for flow analysis, and the cooling passage of the oil was simplified to shorten the time taken for computation. With the diameter of the fan fixed at a constant value, the analysis was performed only by changing the position of the fans. As a result, a vertical position change of the fans does not affect the cooling performance significantly. However, the temperature drop given by the fans positioned on the front region of the transformer is larger than that on the rear region.

Preliminary Design of the Forced Gas Drying System for Spent Nuclear Fuel Dry Storage (사용후핵연료 건식저장을 위한 기체강제순환 건조장치 예비설계)

  • Chae, Gyung-sun;Shin, Kyung-wook;Park, Byeong-mok;Han, Jae-hyun;Lee, Geon-hui;Park, Jae-seok
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.15 no.4
    • /
    • pp.403-409
    • /
    • 2017
  • For dry storage of the spent nuclear fuel (SNF) stored in the storage pool of a nuclear power plant, essentially all moisture must be removed to prevent corrosion of the assembly and canister internals and/or degradation of fuel cladding integrity after SNF canister loading operation. R&D work is now in progress on a forced gas drying system that can be used to remove residual water in canisters. In this work, preliminary design is performed to manufacture the forced gas drying system. This process includes a case study of dry methods for canister moisture removal, relative codes and standards, confirmation of adequate dryness, needs analysis at plant sites, and characteristics of SNF stored in pools. Through this preliminary design work, we obtained a conceptual flow diagram and preliminary P&ID of the forced gas drying system. The results of this study can be used to determine details of the design to manufacture the forced gas drying system.

A Study on the Heat Sink with internal structure using Peltier Module in the Forced Convection (강제대류에서 펠티에 소자를 이용한 내부터널 구조를 가지는 히트싱크에 관한 연구)

  • Lee, Min;Kim, Tae-Wan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3410-3415
    • /
    • 2014
  • The heat generated by electronic devices can result in performance degradation. Therefore, a heat sink has been used to release the operating heat into the air outside. This study addressed a methodology for a heat sink with an inner tunnel. Under forced convection conditions, the heat transfer characteristics were different so the cooling and heating performances were studied for the heat sink with an inner tunnel. This was evaluated by performing the experimental test examining the heat transfer characteristics related to the variance in time and temperature distribution. In the cooling experiment, the temperature of the A-shape was lower than that of the B-shape, when the voltage was 10 V. These experimental results indicate the optimal cooling effect. In a heating experiment, the temperature of the A-shape was higher than that of the B-shape, when the voltage was 13 V. The experimental results showed that the temperature and efficiency of the A-shape were higher than those of the B-shape.

Flow Analyses around the Battery Pack for a NEV (전기자동차용 배터리 팩 주위의 유동장 해석)

  • Kim, H.S.;Han, B.Y.;Park, H.K.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.135-140
    • /
    • 2011
  • The battery pack, a main component of NEV(Neighborhood Electric Vehicle), needs cooling system when it is charging or discharging to prevent the degradation of the battery charging efficiency. The purpose of this study is to analyse the effects of cooling methods, changing positions of inlet and outlet and changing area ratios of inlet and outlet. It has been observed that in the point of uniform cooling suction from the exit side is more efficient than blowing from the inlet. And there is a suitable inlet/outlet area ratio in maximizing the mass flow rate. The numerical analyse using a commercial code STAR-CCM+ version 4.02 were used for the study.

  • PDF

FLOW ANALYSES AROUND THE BATTERY PACK FOR A NEV (전기자동차용 배터리 팩 주위의 유동장 해석)

  • Kim, H.S.;Han, B.Y.;Park, H.K.
    • Journal of computational fluids engineering
    • /
    • v.16 no.3
    • /
    • pp.82-87
    • /
    • 2011
  • The battery pack, a main component of NEV(Neighborhood Electric Vehicle), needs cooling system when it is charging or discharging to prevent the degradation of the battery charging efficiency. The purpose of this study is to analyse the effects of cooling methods, changing positions of inlet and outlet and changing area ratios of inlet and outlet. It has been observed that in the point of uniform cooling, suction from the exit side is more efficient than blowing from the inlet. And there is a suitable inlet/outlet area ratio in maximizing the mass flow rate. A commercial code, STAR-CCM+(ver. 4.02), was used for the numerical study.

Novel stability indicating high-performance liquid chromatography method for the separation and simultaneous quantification of acalabrutinib and its impurities in pharmaceutical formulation

  • Venu Gopal Kamani;Sujatha M;Guna Bhushana Daddala
    • Analytical Science and Technology
    • /
    • v.36 no.1
    • /
    • pp.32-43
    • /
    • 2023
  • This study reports for the first time about a stability indicating RP-HPLC method for qualitative and quantitative determination of acalabrutinib in bulk and dosage form and in presence its impurities 1, 2 and 3. The chromatographic separation was carried on Zorbax XDB-C18 (250×4.6 mm; 5 µ id) as stationary phase, Phosphate buffer pH 6.4 and methanol 80:20 (v/v) as mobile phase at a flow rate of 1.0 mL/min, UV detection was carried at wavelength of 238 nm and the analysis was completed with a run time of 15 min. In these conditions the retention time of acalabrutinib and its impurities 1, 2 and 3 was observed to be 3.50, 4.83, 8.40 and 9.93 min respectively. The method was validated for system suitability, range of analysis, precision, specificity, stability and robustness. Spiked recovery at 50 %, 100 % and 150 % was carried for both standard and impurities and the acceptable % recovery of 98-102 was observed for acalabrutinib and both impurities studied and the % RSD in each spiked level was found to be less than 2. Stability tests were done through exposure of the analyte solution to five different stress conditions i.e expose to 1N hydrochloric acid, 1 N sodium hydroxide, 3 % peroxide, 80 ℃ temperature and UV radiation at 254 nm. In all the degradation condition, standard drug acalabrutinib was detected along with both the impurities studied and the degradation products were successfully separated. In the formulation analysis there is no other chromatographic detection of other impurities and formulation excipients. Hence the developed method was found to be suitable for the quantification of acalabrutinib and can separate and analyse impurities 1 and 2.

Performance Evaluation Study of Solarwall-Photovoltaic Module to Generate Solar Electric Power (SWPV 태양 열-전기 복합생산 모듈 성능평가 연구)

  • Naveed Ahmed T;Kang E. C.;Lee E. J.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.397-402
    • /
    • 2005
  • Photovoltaic (PV) module can generate electricity using sunlight without causing any environmental degradation. Due to higher fossil fuel prices and environmental awareness, PV applications are becoming more popular as clean source of electricity generation. PV output is sensitive to the operating temperature and can be drastically affected in Building Integrated PV (BIPV) systems. PV Solarwall (SWPV) combination and PV systems have been evaluated in this study for improvement in electrical output and system costs. PV modules under forced ventilation. A 75W polycrystalline silicon PV module was fixed on SW in front of the ventilation fan as it was indicated to be the coolest position on the SW in phoenix simulations. The effectiveness of cooling by means of the forced ventilating air stream has been studied experimentally. The results indicate that there appears to be significant difference in temperature as well as electricity output comparing the SWPV and BIPV options. Electrical output power recovered is about $4\%$ during the typical day of the month of February. RETScreen(R) analysis of a 3kW PV system hypothetically located at Taegu has shown that with typical temperature reduction of $15^{{\circ}C$, it is possible to reduce the simple payback periods by one year. The work described in this paper may be viewed as an appraisal of a SWPV system based on its improved electrical and financial performances due to its ability to operate at relatively lower temperatures.

  • PDF

A study of TV Animation broadcasting for system circumference by an unguarded position and lose (TV animation 총량제에 의한 외주제작 시스템의 허와 실에 대한 방향 연구)

  • Kim, Jae-ho
    • Journal of Science of Art and Design
    • /
    • v.11
    • /
    • pp.37-49
    • /
    • 2007
  • TV animation has come a long way to this date since popular animation programs were aired on TV, such as 'Run Little Tiger', 'Run Honey', 'Hurry-Scurry Yeongsimi', beginning with 'Wandering Magpie' on KBS in 1978. However, problematic production process has resulted in the degradation of quality. Consequently, the dwindling viewing rate forced animation advertisers to leave, and the animation production shrank. Under those unfavorable circumstances, the government started to heed messages transmitted from animation producers and went ahead with the 'animation broadcasting quota' in a bid to help revitalize Korean animation industry. This study aimed to identify problems and set the direction for the animation industry by analyzing its fundamental and structural problems.

  • PDF