• Title/Summary/Keyword: force-time curve

Search Result 112, Processing Time 0.034 seconds

Compression and Decompression Properties of Some Vegetables (몇가지 채소류의 압축 및 비압축 특성)

  • Min, Young-Kyoo;Jeong, Heon-Sang
    • Korean Journal of Food Science and Technology
    • /
    • v.29 no.2
    • /
    • pp.266-272
    • /
    • 1997
  • In order to investigate the compression and decompression properties of cucumber, radish, garlic, ginger and potato, edible parts of samples were prepared to size of ${\Phi}\;5\;mm{\times}H\;5\;mm$, and force deformation relationship during application and removal of force were observed. Compositions of sample and cell characteristics were measured, and correlations between them were investigated. Deformation rate was large in initial stage of compression and decreased afterward, but the reverse trends were observed in the decompression. The time and deformation to 9 N were large of 5.30 sec and 1.344 mm in potato, and small of 4.62 sec and 0.896 mm in garlic, respectively. Force(y)-deformation(x) curve between compression and decompression were clearly showed hysteresis loop and relationship of x and y were as follows: y=esp (a+b log(x)). The maximum work was $3.888{\sim}5.099{\times}10^{-3}\;J$ for potato in compression and $2.09{\times}10^{-3}\;J$ for garlic in decompression. Irrecoverable work were large as $77{\sim}96%$ in cucumber, radish and potato, and small as $36{\sim}42%$ in garlic. Compression deformation were large as $1.016{\sim}1.344\;mm$ in potato, and small as $0.656{\sim}0.896\;mm$ in garlic. Degree of elasticity were large as $0.756{\sim}0.777$ in garlic, and small as $0.301{\sim}0.465$ in radish and potato. Compression and decompression characteristic values were showed high correlation with moisture, viscosity of juice, ceil size, density and regularity.

  • PDF

PREPARATION OF AMORPHOUS CARBON NITRIDE FILMS AND DLC FILMS BY SHIELDED ARC ION PLATING AND THEIR TRIBOLOGICAL PROPERTIES

  • Takai, Osamu
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.3-4
    • /
    • 2000
  • Many researchers are interested in the synthesis and characterization of carbon nitride and diamond-like carbon (DLq because they show excellent mechanical properties such as low friction and high wear resistance and excellent electrical properties such as controllable electical resistivity and good field electron emission. We have deposited amorphous carbon nitride (a-C:N) thin films and DLC thin films by shielded arc ion plating (SAIP) and evaluated the structural and tribological properties. The application of appropriate negative bias on substrates is effective to increase the film hardness and wear resistance. This paper reports on the deposition and tribological OLC films in relation to the substrate bias voltage (Vs). films are compared with those of the OLC films. A high purity sintered graphite target was mounted on a cathode as a carbon source. Nitrogen or argon was introduced into a deposition chamber through each mass flow controller. After the initiation of an arc plasma at 60 A and 1 Pa, the target surface was heated and evaporated by the plasma. Carbon atoms and clusters evaporated from the target were ionized partially and reacted with activated nitrogen species, and a carbon nitride film was deposited onto a Si (100) substrate when we used nitrogen as a reactant gas. The surface of the growing film also reacted with activated nitrogen species. Carbon macropartic1es (0.1 -100 maicro-m) evaporated from the target at the same time were not ionized and did not react fully with nitrogen species. These macroparticles interfered with the formation of the carbon nitride film. Therefore we set a shielding plate made of stainless steel between the target and the substrate to trap the macropartic1es. This shielding method is very effective to prepare smooth a-CN films. We, therefore, call this method "shielded arc ion plating (SAIP)". For the deposition of DLC films we used argon instead of nitrogen. Films of about 150 nm in thickness were deposited onto Si substrates. Their structures, chemical compositions and chemical bonding states were analyzed by using X-ray diffraction, Raman spectroscopy, X-ray photoelectron spectroscopy and infrared spectroscopy. Hardness of the films was measured with a nanointender interfaced with an atomic force microscope (AFM). A Berkovich-type diamond tip whose radius was less than 100 nm was used for the measurement. A force-displacement curve of each film was measured at a peak load force of 250 maicro-N. Load, hold and unload times for each indentation were 2.5, 0 and 2.5 s, respectively. Hardness of each film was determined from five force-displacement curves. Wear resistance of the films was analyzed as follows. First, each film surface was scanned with the diamond tip at a constant load force of 20 maicro-N. The tip scanning was repeated 30 times in a 1 urn-square region with 512 lines at a scanning rate of 2 um/ s. After this tip-scanning, the film surface was observed in the AFM mode at a constant force of 5 maicro-N with the same Berkovich-type tip. The hardness of a-CN films was less dependent on Vs. The hardness of the film deposited at Vs=O V in a nitrogen plasma was about 10 GPa and almost similar to that of Si. It slightly increased to 12 - 15 GPa when a bias voltage of -100 - -500 V was applied to the substrate with showing its maximum at Vs=-300 V. The film deposited at Vs=O V was least wear resistant which was consistent with its lowest hardness. The biased films became more wear resistant. Particularly the film deposited at Vs=-300 V showed remarkable wear resistance. Its wear depth was too shallow to be measured with AFM. On the other hand, the DLC film, deposited at Vs=-l00 V in an argon plasma, whose hardness was 35 GPa was obviously worn under the same wear test conditions. The a-C:N films show higher wear resistance than DLC films and are useful for wear resistant coatings on various mechanical and electronic parts.nic parts.

  • PDF

Characteristics of perylene OTFT fabricated in UHV (초고진공환경에서 제작된 perylene 박막 트랜지스터의 특성)

  • 박대식;강성준;김희중;노명근;황정남
    • Journal of the Korean Vacuum Society
    • /
    • v.13 no.1
    • /
    • pp.9-13
    • /
    • 2004
  • Perylene is an interesting material known to have P-type and N-type characteristics at the same time. We prepared perylene thin-films in ultrahigh vacuum with two different deposition rates of 0.1 $\AA$/s and 1.0 $\AA$/s in order to study the dependence of film characteristics on the growth condition. The smaller average grain size with larger surface coverage as well as the better crystallinity were observed on the perylene film prepared under 1.0 $\AA$/s deposition rate in x-ray diffraction (XRD) and atomic force microscopy (AFM) study. For studying electrical property of the film, perylene organic thin-film transistor (OTFT) with gold contacts was fabricated on $SiO_2$/Si surface in UHV condition. The prepared perylene OTFT device shows P-type characteristic. The obtained hole mobility in the current-voltage characteristic curve was$2.23\times10^{-5}\textrm{cm}^2$/Vs.

Experimental study on transmission and stability of submerged breakwater (잠제의 전달율과 안정성에 관한 실험적 연구)

  • Kim, Yong-Woo;Yoon, Han-Sam;Kim, Hong-Jin;Ryu, Cheong-Ro;Sohn, Byung-Kyu
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2003.10a
    • /
    • pp.213-219
    • /
    • 2003
  • As the 2-D hydraulic experimental results for the submerged rubble-mound structure, we have concerned with their stability/function characteristics of structures by the effects of wave force, scour/deposition at the toe and wave transmission ratio at the lee-side sea. And as to investigate the variation characteristics of wave transmission ratio which depended to a geometrical structure of the submerged breakwater profiles, the critical conditions for the depth of submergence and crest width obviously presented. In summary, there results lead us to the conclusions that the wave control capabilities of submerged breakwaters by the variation of the submergence depth is high about 4 time degrees at the efficiency than the that of crest width. The destruction of covering block at the crest generated at the region which located between maximum damage curve, it maximum damage/failure station from the toe of the structure were 0.2L. As the wave transmission coefficient and the slope of the structure increase, the damage/failure ratio and the maximum scour depth at the toe was extended, respectively. When maximum scour depth happened. The destruction of covering block which located at the toe generated at the front slope destruction. Finally, it was found from the results that the optimization of structure may be obtained by the efficiently decision of the submergence depth and crest width in the permissible range of wave transmission ratio.

  • PDF

Analytical Modeling for Reinforced Concrete Columns with Relaxed Section Details

  • Kim, Taewan;Chu, Yurim;Park, Hong-Gun
    • Architectural research
    • /
    • v.19 no.3
    • /
    • pp.79-87
    • /
    • 2017
  • In earthquake engineering, dynamic analyses are usually conducted by using a nonlinear analytical model of the entire building in order to identify the performance against earthquakes. At the same time, a large number of dynamic analyses are required to consider uncertainties on analytical models and ground motions. Therefore, it is necessary for the analytical model to be adequate, that is to say, the runtime should not be too long as the entire building is modeled to be in much detail, or the nonlinear model should not yield outputs very far from the actual ones by excluding important behaviors too much. The analytical model is usually developed based on experimental results, which have been already conducted for reinforced concrete columns with relaxed details. Therefore, this study aimed at making analytical models to be able to simulate the hysteretic behavior of the columns simply and easily. The analytical model utilizes a lumped hinge model to represent nonlinear moment-rotation hysteretic behavior of RC columns, which is feasible for nonlinear dynamic analyses usually conducted in earthquake engineering and for matching the analytical model to test results. For the analytical model, elements and material models provided by OpenSees are utilized. The analytical model can define the envelope curve, pinching, and unloading stiffness deterioration, but shortcoming of this model is not to be able to consider axial force-moment interaction directly and to simulate strength deterioration after post-capping completely. However, the analytical model can still represent test results well by considering that the goal of this study is to propose a general way to represent the hysteretic behavior of RC columns with relaxed details, not to provide parameters for a refined hysteretic model that can be just applied case by case.

A Study on the Global Motion Performance of Floater and Mooring Due to Arrangement of Detachable Mooring System (탈착형 계류시스템 배치에 따른 부유식 해양구조물의 운동 및 계류성능에 관한 연구)

  • Kangsu Lee;Hyun-Sung Kim;Byoung Wan Kim
    • Journal of Wind Energy
    • /
    • v.14 no.2
    • /
    • pp.26-33
    • /
    • 2023
  • In this study, the global response characteristics of floater and mooring for floating offshore wind turbine with a detachable mooring system are performed. Global motion and structural response result extracted from the coupled motion analysis of 10MW DTU floating offshore wind turbine with detachable mooring system modeled by high-order boundary element model and finite element mesh, were used to study the characteristics of tension on mooring lines subjected to three different types of ocean loads. Breaking limit of mooring line characterized by wind, current and wave load has a major effect on the distribution of mooring tension found in time domain analysis. Based on the numerical results of coupled motion analysis, governing equation for calculating the motion response of a floater under ocean loads, and excitation force and surge motion and tension respectively are presented using excursion curve. It is found that the response of floater is reliable and accurate for calculating the tension distributions along the mooring lines under complex loadings. This means that the minimun breaking limit of mooring system satisfied a design criteria at ultimate ocean environmental loading condtions.

A Study on Torsional Characteristics of the Car Body Types at Cornering Motion (선회주행 시 차체의 비틀림 특성에 관한 연구)

  • Lee, Joon-Seong;Cho, Seong-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.739-744
    • /
    • 2017
  • Elastic deformation and fatigue damage can cause the permanent deformation of a kart's frame during turning, affecting the kart's driving performance. A kart's frame does not contain any suspension or differential devices and, therefore, the dynamic behavior caused by torsional deformation when driving along a curve can strongly affect these two kinds of deformations. To analyze the dynamic behavior of a kart along a curved section, the GPS trajectory of the kart is obtained and the torsional stress acting on the kart-frame is measured in real time. The mechanical properties of leisure and racing karts are investigated by analyzing their material properties and conducting a tensile test. The torsional stress concentration and frame distortion are investigated through a stress analysis of the frame on the basis of the obtained results. Leisure and racing karts are tested in each driving condition using driving analysis equipment. The behavior of a kart when being driven along a curved section is investigated through this test. Because load movement occurs owing to centrifugal force when driving along a curve, torsional stress acts on the kart's steel frame. In the case of a leisure kart, the maximum torsional stress derived from the torsional fatigue limit was found to be 230 MPa, and the torsional fatigue limit coefficient was 0.65 when driving at a speed of 40 km/h. Furthermore, the driving elements during the cornering of a kart were measured based on an actual auto-test after installing a driving measurement system, and the driving behavior of the kart was analyzed by measuring its vertical displacement.

Analysis of the Contact Pressure Distribution and Kinetics of Knee Implant Using the Simulator (Simulator를 이용한 인공무릎관절 접촉면의 압력분포 및 운동성 분석)

  • 이문규;김종민;김동민;최귀원
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.363-367
    • /
    • 2003
  • Contact area and pressure are important factors which directly influence a life of knee implants. Since implant's mechanical functions should be experimentally evaluated for clinical use, many studies using a knee simulator and a pressure sensor system have been conducted. However it has not been reported that the contact pressure's distribution of a knee implant motion was estimated in real-time during a gate cycle. Therefore. the objective of this study was to analyze the contact pressure distribution for the motion of a joint using the knee simulator and I-scan sensor system. For this purpose, we developed a force-controlled dynamic knee simulator to evaluate the mechanical performance of artificial knee joint. This simulator includes a function of a soft tissue and has a 4-degree-of-freedom to represent an axial compressive load and a flexion angle. As axial compressive force and a flexion angle of the femoral component can be controlled by PC program. The pressure is also measured from I-scan system and simulator to visualize the pressure distribution on the joint contact surfaces under loading condition during walking cycle. The compressive loading curve was the major cause for the contact pressure distribution and its center move in a cycle as to a flexion angie. In conclusion, this system can be used to evaluate to the geometric interaction of femoral and tibial design due to a measured mechanical function such as a contact pressure, contact area and a motion of a loading center.

Preparation and Bioequivalence Test of Acetaminophen Liquid Suppository (아세트아미노펜 액상좌제의 제초 및 생물학적 동등성 평가)

  • 김종국;최한곤;이사원;고종호;이미경
    • Biomolecules & Therapeutics
    • /
    • v.6 no.2
    • /
    • pp.213-218
    • /
    • 1998
  • A novel in situ-gelling and mucoadhesive acetaminophen liquid suppository was developed to improve the patient compliance of conventional solid suppository. In this study, acetaminophen liquid suppository, Likipe $n_{R}$, [aminophen/Poloxamer 407/Poloxamer 188/so4ium alginate (5/15/19/0.6%)] with relation temperature at 30-36 "C and suitable gel strength and bioadhesive force, dissolution pattern similar to conventional solid type suppository, Suspe $n_{R}$, was developed. Furthermore, the bioequivalence of two acetaminophen products was evaluated in 16 normal male volunteers (age 22-27 yr, body weight 56-72 kg) following sidle rectal administration. Test product was Likipe $n_{R}$ suppository (Dong-Wha Pharm. Corp., Korea)and reference product was Suspe $n_{R}$204-212 suppository (Hanmi Pharm. Corp., Korea). Both products contain 125 mg of acetaminophen. Four Suppositories of the test and the reference product were administered to the volunteers, respectively, by randomized two period cross-over study (2$\times$2 Latin square method). The determination of acetaminophen was accomplished using HPLC. Average drug concentrations at each sampling time and pharmacokinetic parameters calculated were not significantly different between two products (p>0.05); the area under the curve to last sampling time (24 hr) (AU $Co_{-2}$4h/) (30.14$\pm$8.64 vs 27.98$\pm$ 6.53 $\mu$g .h/ml), maximum plasma concentration ( $C_{max}$) (3.29$\pm$0.87 vs 3.60$\pm$0.66 $\mu$g/ml) and time to maximum plasma concentration ( $T_{max}$) (2.91 $\pm$0.55 vs 2.69$\pm$0.60 h). The differences of mean AUCo $_{24h}$, C-a. and T-between the two products (7.18%, 9.58% and 7.53%, respectively) were less than 20%. The power (1-7) and treatment difference ($\Delta$) for AU $Co_{24h}$, $C_{max}$ and $T_{max}$ were more than 0.8 and less than 0.2, respectively at $\alpha$=0.1. The confidence limits for AU $Co_{24h}$, $C_{max}$ and $T_{max}$ (-0.81 ~13.55%, -1.56~ 17.60 and -3.81 ~18.87%, respectively) were less than $\pm$ 20% at $\alpha$=0.1. These results suggest that the bioavailability of Likipe $n_{R}$ suppository is not significantly different from that of Suspe $n_{R}$ suppsitory. Therefore, two products are bio-equivalent based on the current results.results.lts.sults.results.lts.

  • PDF

The Properties of a Nonlinear Direct Spectrum Method for Estimating the Seismic Performance (내진성능평가를 위한 비선형 직접스펙트럼법의 특성)

  • 강병두;김재웅
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.6 no.4
    • /
    • pp.65-73
    • /
    • 2002
  • It has been recognized that the damage control must become a more explicit design consideration. In an effort to develop design methods based on performance it is clear that the evaluation of the nonlinear response is required. The methods available to the design engineer today are nonlinear time history analyses, monotonic static nonlinear analyses, or equivalent static analyses with simulated nonlinear influences. Some building codes propose the capacity spectrum method based on the nonlinear static analysis(pushover analysis) to determine the earthquake-induced demand given by the structure pushover curve. These procedures are conceptually simple but iterative and time consuming with some errors. This paper presents a nonlinear direct spectrum method(NDSM) to evaluate seismic performance of structures, without iterative computations, given by the structural initial elastic period and yield strength from the pushover analysis, especially for MDF(multi degree of freedom) systems. The purpose of this paper is to investigate the accuracy and confidence of this method from a point of view of various earthquakes and unloading stiffness degradation parameters. The conclusions of this study are as follows; 1) NDSM is considered as practical method because the peak deformations of nonlinear system of MDF by NDSM are almost equal to the results of nonlinear time history analysis(NTHA) for various ground motions. 2) When the results of NDSM are compared with those of NTHA. mean of errors is the smallest in case of post-yielding stiffness factor 0.1, static force by MAD(modal adaptive distribution) and unloading stiffness degradation factor 0.2~0.3.