• Title/Summary/Keyword: force spectroscopy

Search Result 516, Processing Time 0.036 seconds

Synthesis of ZnO/Zn(OH)2 Nanosheets Using Ionic Layer Epitaxy (이온층 에피택시법을 이용한 ZnO/Zn(OH)2 나노시트의 합성)

  • Jeong, Gyu Hyun;Nam, Dong Hyun;Ryu, Gyeong Hee
    • Korean Journal of Materials Research
    • /
    • v.32 no.3
    • /
    • pp.153-160
    • /
    • 2022
  • ZnO nanosheets have been used for many devices and antibacterial materials with wide bandgap and high crystallinity. Among the many methods for synthesizing ZnO nanostructures, we report the synthesis of ZnO/Zn(OH)2 nanosheets using the ionic layer epitaxy method, which is a newly-developed bottom-up technique that allows the shape and thickness of ZnO/Zn(OH)2 nanosheets to be controlled by temperature and time of synthesis. Results were analyzed by scanning electron microscopy and atomic force microscopy. The physical and chemical information and structural characteristics of ZnO/Zn(OH)2 nanosheets were compared by X-ray photoelectron spectroscopy and X-ray diffraction patterns after various post-treatment processes. The crystallinity of the ZnO/Zn(OH)2 nanosheets was confirmed using scanning transmission electron microscopy. This study presents details of the control of the size and thickness of synthesized ZnO/Zn(OH)2 nanosheets with atomic layers.

Experimental and computational insights into the adsorption of a hydrazone-based heterocyclic compound on steel rebar in synthetic concrete pore solution (합성 콘크리트 공극 솔루션에서 철근에 히드라존 기반 헤테로고리 화합물의 흡착에 대한 실험 및 계산 통찰력)

  • Lgaz, Hassane;Karthick, Subbiah;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.73-74
    • /
    • 2022
  • The corrosion inhibitive effect of a new hydrazone-based heterocyclic compound for steel in simulated concrete pore solution with 3.5 wt.% sodium chloride was investigated by experimental and computational techniques. Electrochemical studies, up to 30 days of immersion, and surface analysis (X-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM), and scanning electron microscope (SEM)) were performed to assess the corrosion protection abilities of investigated compound for steel rebar. Results showed that adding the organic compound to the chloride contaminated concrete pore solution decreased the corrosion rate of the steel rebar thanks to the effective adsorption of inhibitor molecules. After 30 days of immersion of steel rebar in inhibited chloride contaminated synthetic concrete pore solution, the inhibition efficiency exceeded 80% at low concentration of 1 mmol/L. Computational studies by Density Functional based Tight Binding (DFTB) method revealed the formation of covalent bonds between the hydrazone molecule and the iron surface.

  • PDF

Assessment of Abnormality in Skeletal Muscle Metabolism in Patients with Chronic Lung Desease by $^{31}P$ Magnetic Resonance Spectroscopy ($^{31}P$ 자기 공명분석법을 이용한 만성 폐질환 환자에서의 골격근대사 이상에 관한 연구)

  • Cho, Won-Kyoung;Kim, Dong-Soon;Lim, Tae-Hwan;Lim, Chae-Man;Lee, Sang-De;Koh, Youn-Suck;Kim, Woo-Sung;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.3
    • /
    • pp.583-591
    • /
    • 1997
  • The functional derangement of skeletal muscles which may be attributed to chronic hypoxia has been accepted as a possible mechanism of exercise impairment in patients with chronic obstructive pulmonary disease (COPD). The metabolic changes in skeletal muscle in patients with COPD are characterized by impaired oxidative phosphorylation, early activation of anaerobic glycolysis and excessive lactate and hydrogen ion production with exercise. But the cause of exercise limitation in patients with chronic lung disease without hypoxia has not been known. In order to evaluate the change in the skeletal muscle metabolism as a possible cause of the exercise limitation in chronic lung disease patients without hypoxia, we compared the muscular metabolic data of seven male patients which had been derived from noninvasive $^{31}P$ magnetic resonance spectroscopy(MRS) with those of five age-matched normal male control persons. $^{31}P$ MRS was studied during the sustained isometric contraction of the dominant forearm flexor muscles up to the exhaustion state and the recovery period. Maximal voluntary contraction(MVC) force of the muscle was measured before the isometric exercise, and the 30% of MVC force was constantly loaded to each patient during the isometric exercise. There were no differences of intracellular pH (pHi) and inorganic phosphate/phosphocreatine(Pi/PCr) at baseline, exhaustion state and recovery period between two groups. But pHi during the exercise was lower in patients group than the control group (p < 0.05). Pi/PCr during the exercise did not show significant difference between two groups. These results suggest that the exercise limitation in chronic lung disease patients without hypoxia also could be attributed to the abnormalities in the skeletal muscle metabolism.

  • PDF

Surface characteristics and biocompatibility of bioinert nitrides ion plated titanium implant (생불활성 질화물 이온도금된 티타늄 임프란트의 표면특성 및 생체적합성)

  • Chang, Kap-Sung;Kim, Heung-Joong;Park, Joo-Cheol;Kim, Byung-Ock;Han, Kyung-Yoon
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.1
    • /
    • pp.209-231
    • /
    • 1999
  • Even though titanium(Ti) and its alloys are the most used dental implant materials, there are some problems that Ti wears easily and interferes normal osteogenesis due to the metal ions. Ti coated with bioactive ceramics such as hydroxyapatite has also such problems as the exfoliation or resorption of the coated layer, Recent studies on implant materials have been proceeding to improve physical properties of the implant substrate and biocompatibility of the implant surfaces. The purpose of the present study was to examine the physical property and bone tissue compatibility of bioinert nitrides ion plated Ti, Button type specimens(14mm in diameter, 2.32rrun in height) for the abrasion test and cytotoxicity test and thread type implants(3.75mm in diameter, 6mm in length) for the animal experiments were made from Ti(grade 2) and 316LVM stainless steel. Ti specimens were ion plated with TiN, ZrN by the low temperature arc vapor deposition, and the depth profile of the TiN/Ti, ZrN/Ti ion plated surface was examined by Auger Electron Spectroscopy. Three kind of button type specimens .of TiN/Ti, ZrN/Ti and Ti were used for abrasion test, and HEPAlClC7 cells and CCD cells were cultivated for 4 days with the specimens for cytotoxicity test. Thread type implants of TiN/Ti, ZrN/Ti, Ti, 316LVM were implanted on the femur of 6 adult dogs weighing 10kg-13kg. Two dogs were sacrified for histological examination after 45 days and 90 days, and four dogs were sacrified for the removal torque test of the implant') after 90 days. The removal torque force was measured by Autograph (Shimadzu Co., AGS-1000D series, Japan). Abrasion resistance of TiN/Ti was the highest, and that of ZrN/Ti and Ti were followed. The bioinert nitride ion plated Ti had much better abrasion resistance, compared with Ti, In the cytotoxicity test, the number of both cells were increased in all specimens, and there were no significant difference in cytotoxic reaction among all groups (p>0.1), In histological examination, 316LVM showed the soft tissue engagement in interface between the implant and bone, but the other materials after 45 days noted immature new bone formation in the medullary portion along the implant surface, and those after 90 days showed implant support by new bone formation in both the cortical and the medullary portion, The removal torque force of Tilv/Ti showed significantly higher than that of Ti(p(O,05). The difference in removal torque force between TiN/Ti and ZrN/Ti was not significant(p>0.05), and that of 316LVM was lowest among all groups(p<0.05). These results suggest that bioinert nitrides ion plated Ti can resolve the existing problems of Ti and bioactive ceramics, and it may be clinically applicable to human.

  • PDF

Surface Modification of Polymethylmethacrylate(PMMA) by Ion-assisted reaction (이온 보조 반응법(Ion-assisted-reaction)을 이용한 Polymethylmethacrylate (PMMA)의 표면개질)

  • Jung, Sun;Cho, Jun-Sik;Choi, Sung-Chang;Koh, Seok-Keun
    • Korean Journal of Materials Research
    • /
    • v.9 no.5
    • /
    • pp.446-451
    • /
    • 1999
  • Surface of Polymethylmethacrylate (PMMA) was modified by ion assisted reaction in which ion beam of Ar or$ O_2$is irradiated on polymer in reaction gas environment. Ion beam energy was changed from 600 to 1000eV, and ion doses were varied from $5\times10^{14} ions/cm^2 to 1\times10^{17} ions/cm^2$. Contact angle and surface energy of modified PMMA were measured by contact angle micrometer using distilled water and formamide. In the case of $Ar^+$ ion irradiation only, the contact angle reduced from $68^{\circ} to $35^{\circ}$ and the surface energy was changed from 46 dyne/cm to 60 dyne/cm. The contact angle significantly decreased to $14^{\circ}$and the surface energy increased to 72 dyne/cm when the surface of PMMA was modified by oxygen ion irradiation in oxygen gas environment. Improvement of wettability results from the formation of new hydrophilic group which is identified as C-O chain by XPS analysis. Recovery of wettability in dry air and maintenance of it in water condition were explained in view of the formation of hydrophilic group.

  • PDF

INFLUENCE OF TUNGSTEN CARBIDE/CARBON COATING ON THE PRELOAD OF IMPLANT ABUTMENT SCREWS (임플랜트 지대주 나사의 텅스텐 카바이드/탄소 코팅이 전하중에 미치는 영향에 관한 연구)

  • Choi Jin-Uk;Jeong Chang-Mo;Jeon Young-Chan;Lim Jang-Seop;Jeong Hee-Chan;Eom Tae-Gwan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.2
    • /
    • pp.229-242
    • /
    • 2006
  • Statement of problem: In order to increase preload with reducing the friction coefficient, abutment screws coated with pure gold and Teflon as dry lubricant coatings have been introduced. But the reported data indicate that if screw repeated tightening and loosening cycle, an efficiency of increasing preload was decreased by screw surface wearing off. Purpose: This study was to evaluate the influence of tungsten carbide/carbon coating, which has superior hardness and frictional wear resistance, on the preload of abutment screws and the stability of coating surface after repeated closures. Material and method: The rotational values of abutment screws and the compressive forces between abutment and fixture were measured in implant systems with three different joint connections, one external butt joint and two internal cones. Moreover the stability and the alteration of coating surface were examined by comparison of the compressive force and the removable torque values during 10 consecutive trials, observation with scanning electron microscope and analyzed the elemental composition with energy dispersive x-ray spectroscopy Results and conclusion: 1. Application of coating resulted in significant increase of compressive force in all implant systems(P<.05). The increasing rate of compressive force by coating in external butt joint was gloater than those in internal cones (P<.05). 2. Coated screw showed the significant additional rotation compared to non-coated screw in all implant systems (P<.05). There were no significant differences in the increasing rate of rotation among implant systems (P>.05). 3. Removable torque values were greater with non-coated screw than that with coated screw (P<.05). 4. Coated screw showed insignificant variations in the compressive forces during 10 consecutive trials(P>.05) 5. After repeated trials, the surface layer of coated screw was maintained relatively well. However surface wearing and irregular titanium fragments were found in non-coated screw.

Effect of crude fibre additives ARBOCEL and VITACEL on the physicochemical properties of granulated feed mixtures for broiler chickens

  • Jakub Urban;Monika Michalczuk;Martyna Batorska;Agata Marzec;Adriana Jaroszek;Damian Bien
    • Animal Bioscience
    • /
    • v.37 no.2
    • /
    • pp.274-283
    • /
    • 2024
  • Objective: The aim of the study was to evaluate the physicochemical properties (nutrient composition, pH, water content and activity, sorption properties) and mechanical properties (compression force and energy) of granulated feed mixtures with various inclusion levels of crude fibre concentrates ARBOCEL and VITACEL for broiler chickens, i.e. +0.0% (control group - group C), +0.3%, +0.8%, +1.0%, +1.2%. Methods: The feed mixtures were analyzed for their physicochemical properties (nutrient composition by near-infrared spectroscopy, pH with the use a CP-401 pH meter with an IJ-44C glass electrode, water content was determined with the drying method and activity was determined with the Aqua Lab Series 3, sorption properties was determined with the static method) and mechanical properties (compression force and energy with the use TA-HD plus texture analyzer). The Guggenheim-Anderson-de Boer (GAB) model applied in the study correctly described the sorption properties of the analyzed feed mixtures in terms of water activity. Results: The fibre concentrate type affected the specific surface area of the adsorbent and equilibrium water content in the GAB monolayer (p≤0.05) (significantly statistical). The type and dose of the fibre concentrate influenced the dimensionless C and k parameters of the GAB model related to the properties of the monolayer and multilayers, respectively (p≤0.05). They also affected the pH value of the analyzed feed mixtures (p≤0.05). In addition, crude fibre type influenced water activity (p≤0.05) as well as compression energy (J) and compression force (N) (p≤0.001) (highly significantly statistical) of the feed mixtures. Conclusion: The physicochemical analyses of feed mixtures with various inclusion levels (0.3%, 0.8%, 1.0%, 1.2%) of crude fiber concentrates ARBOCEL or VITACEL demonstrated that both crude fiber types may be used in the feed industry as a feedstuff material to produce starter type mixtures for broiler chickens.

Study on the hydrophobic modification of zirconia surface for organic-inorganic hybrid coatings (유-무기 하이브리드 코팅액 제조를 위한 지르코니아 표면의 소수화 개질 연구)

  • Lee, Soo;Moon, Sung Jin;Park, Jung Ju
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.2
    • /
    • pp.260-270
    • /
    • 2017
  • Zirconia has white color and physical, chemical stability, also using in high temperature materials and various industrial structural ceramics such as heat insulating materials and refractories due to their low thermal conductivity, excellent strength, toughness, and corrosion resistance. If hydrophobically modified zirconia is introduced into a hydrophobic acrylate coating solution, the hardness, chemical, electrical, and optical properties will be improved due to the better dispersibility of inorganic particle in organic coating media. Thus, we introduced $-CH_3$ group through silylation reaction using either trimethylchlorosilane(TMCS) or hexamethyldisilazane(HMDZ) on zirconia surface. The $Si-CH_3$ peaks derived from TMCS and HMDZ on hydrophobically modified zirconia surface was confirmed by FT-IR ATR spectroscopy, and introduction of silicon was confirmed by FE-SEM/EDS and ICP-AES. In addition, the sedimentation rate result in acrylate monomer of the modified zirconia showed the improved dispersibility. Comparison of the sizes of a pristine and the modified zirconia particles, which were clearly measured not by the normal microscope but by particle size analysis, provided a pulverizing was occurred by physical force during the silylation process. From the BET analysis data, the specific surface area of zirconia was approximately $18m^2/g$ and did not significantly change during modification process.

Synthesis of P3HT-b-P4VP via Anionic Polymerization and its Physical Properties in Various Solvents (음이온 중합법 기반 P3HT-b-P4VP 블록공중합체 정밀 합성 및 이의 용매에 따른 물리적 특성 변화 연구)

  • Hwang, Sung Yeon;Park, Jeyoung;Oh, Dongyeop X.
    • Applied Chemistry for Engineering
    • /
    • v.29 no.3
    • /
    • pp.336-341
    • /
    • 2018
  • In general, the synthesis of poly(3-hexylthiophene)(P3HT)-based block copolymers requires at least a 4-5 step process. To control the molecular weight, molecular weight distribution, and block ratio, the reaction conversion and time should be monitored. In addition, the reaction scale usually limited to several mg to g was difficult to increase due to the limitations of living radical polymerizations. In this study, we synthesized P3HT-b-poly(4-vinylprydine) (P3HT-b-P4VP) with a final product quantity of > 19 g via a 2-step synthetic method with an anionic polymerization. In this method, the molecular weight and molecular weight distribution of P3HT-b-P4VP can be well controlled without monitoring the reaction conversion. We also studied physical properties of P3HT-b-P4VP depending on different solvent systems, which were investigated by UV-vis spectroscopy, atomic force microscopy, and ultraviolet photoelectron spectroscopy.

Effect of the catalyst deposition rates on the growth of carbon nanotubes

  • Ko, Jae-Sung;Choi, In-Sung;Lee, Nae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.264-264
    • /
    • 2010
  • Single-walled carbon nanotubes (SWCNTs) were grown on a Si wafer by using thermal chemical vapor deposition (t-CVD). We investigated the effect of the catalyst deposition rate on the types of CNTs grown on the substrate. In general, smaller islands of catalyst occur by agglomeration of a catalyst layer upon annealing as the catalyst layer becomes thinner, which results in the growth of CNTs with smaller diameters. For the same thickness of catalyst, a slower deposition rate will cause a more uniformly thin catalyst layer, which will be agglomerated during annealing, producing smaller catalyst islands. Thus, we can expect that the smaller-diameter CNTs will grow on the catalyst deposited with a lower rate even for the same thickness of catalyst. The 0.5-nm-thick Fe served as a catalyst, underneath which Al was coated as a catalyst support as well as a diffusion barrier on the Si substrate. The catalyst layers were. coated by using thermal evaporation. The deposition rates of the Al and Fe layers varied to be 90, 180 sec/nm and 70, 140 sec/nm, respectively. We prepared the four different combinations of the deposition rates of the AI and Fe layers. CNTs were synthesized for 10 min by flowing 60 sccm of Ar and 60 sccm of $H_2$ as a carrier gas and 20 sccm of $C_2H_2$ as a feedstock at 95 torr and $810^{\circ}C$. The substrates were subject to annealing for 20 sec for every case to form small catalyst islands prior to CNT growth. As-grown CNTs were characterized by using field emission scanning electron microscopy, high resolution transmission electron microscopy, Raman spectroscopy, UV-Vis NIR spectroscopy, and atomic force microscopy. The fast deposition of both the Al and Fe layers gave rise to the growth of thin multiwalled CNTs with the height of ${\sim}680\;{\mu}m$ for 10 min while the slow deposition caused the growth of ${\sim}800\;{\mu}m$ high SWCNTs. Several radial breathing mode (RBM) peaks in the Raman spectra were observed at the Raman shifts of $113.3{\sim}281.3\;cm^{-1}$, implying the presence of SWCNTs (or double-walled CNTs) with the tube diameters 2.07~0.83 nm. The Raman spectra of the as-grown SWCNTs showed very low G/D peak intensity ratios, indicating their low defect concentrations.

  • PDF