• Title/Summary/Keyword: footing settlement

Search Result 78, Processing Time 0.02 seconds

Application of Scale Effect in Estimating Bearing Capacity and Settlement of Footing from Plate-Load Test (평판재하시험으로부터 실제기초의 지지력 및 침하량 산정시 Scale Effect)

  • 정형식;김도열
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.350-357
    • /
    • 2002
  • The scale effect should be considered to determine the bearing capacity and settlement of footings from Plate-Load Test, because of the size difference between a footing and a loading plate. To analyze characteristics of bearing capacity and settlement according to the difference of loading plate sizes, model tests were peformed with four different sizes of square plate, which is B=10, 15, 20 and 25cm respectively, on five different kinds of subsoil, which is pure sand(100:0), sand-clay mixed soil(75:25, 50:50, 25:75), and pure clay(0:100). Based on the analyzed results, this paper also proposed a method of bearing capacity and settlement determination, where scale effect is considered depending on the mixing ratio of sand and clay. Applying the formular proposed in this research to field problems, it is expected that evaluation of bearing capacity and settlement of footings can be more reliable and more economic construction can be achieved.

  • PDF

The Stability of Strip Footing above Underground Cavity (지하공동에 인접한 연속기초의 안정성)

  • Oh, Se-Wook;Lee, Bong-Jik;Bae, Woo-Seok
    • Journal of the Korean GEO-environmental Society
    • /
    • v.7 no.3
    • /
    • pp.69-76
    • /
    • 2006
  • In this study, an experimental study in sand ground that was prepared by raining method was performed for modeling the bearing capacity behavior of strip footing above a cavity. The critical range of bearing capacity of the strip footing affected by underground cavity was investigated by comparing results between experiment and theory. The size of the critical region depends on several factors such as footing shape, soil property, cavity size and cavity shape. The ultimate bearing capacity was more influenced by the depth of the underground cavity than the eccentricity of the underground. In addition, an underground cavity influences on not only the decrease of the bearing capacity, but also the differential settlement of a strip footing.

  • PDF

Probabilistic Analysis of Shallow Foundation Settlements (얕은기호 침하의 확률론적 해석)

  • 정두영;오병현
    • Geotechnical Engineering
    • /
    • v.9 no.3
    • /
    • pp.77-90
    • /
    • 1993
  • In the settlement analysis of shallow foundation soil properties, loads and soil strata involve many uncertainties so it is necessary to do analysis of settlement that considers the probabilistic properties of each variable. This study is performed to probabilistic analysis for settlement of shallow foundation consisted of individual footings by using Monte Carlo Method. To consider the uncertainty of variables, both the soil properties and loads are assumed to be normal distribution random variables and get settlement mean and coefficient of variation of individual footing. And the settlement of each individual footing is also assumed to be normal distribution. Settlement of each individual footing which considers the probability of soft soil pockets in soil strata follows Markov process. Then it is performed to do sensitivity analysis which is involved to excess probability of allowable criteria of maxi mum settlement and differential settlement according to varity of each variable. It is thought to be proper that the settlement analysis of shallow foundation should be analyzed considering uncertainty of variables and soil stratum conditions.

  • PDF

Analysis of Settlement Characteristics of Shallow Foundation on Sandy Soil Overlained by Rigid Ground (강성지반위 사질토층에 위치한 얕은기초의 침하량특성분석)

  • Hwang, Hui-Seok;Kim, Dong-Geon;Yoo, Nam-Jae
    • Journal of Industrial Technology
    • /
    • v.34
    • /
    • pp.45-52
    • /
    • 2014
  • In this paper the settlement characteristic of shallow foundation on sandy soil overlained by rigid ground was investigated by analyzing results of model tests. For model experiments, model tests were performed with sandy soils sampled from the field, changing the relative density of sandy soil and the ratio of thickness of sandy layer(H) to the width of model strip footing(B). As result of tests, settlement of sandy soils increases as the value of H/B increases, whereas it increases with relative density of soil. Bearing capacity decreases as the thickness of the sand layer relative to the footing width increases. In order to analyze the settlement characteristics of sandy ground, the results of model tests were compared with the predicted values using the empirical formulas proposed by Terzaghi, De Beer and Schmertmann. The method by De Beer was found to be in good agreements with test results.

  • PDF

Behavior of eccentrically inclined loaded footing resting on fiber reinforced soil

  • Kaur, Arshdeep;Kumar, Arvind
    • Geomechanics and Engineering
    • /
    • v.10 no.2
    • /
    • pp.155-174
    • /
    • 2016
  • A total of 104 laboratory model tests on a square footing subjected to eccentrically inclined loads supported by sand reinforced with randomly distributed polypropylene fibers were conducted in order to compare the results with those obtained from unreinforced sand and with each other. For conducting the model tests, uniform sand was compacted in a test box at one particular relative density of compaction. The effect of percentage of reinforcement used, thickness of the reinforced layer, angle of inclination of load to vertical and eccentricity of load applied on various prominent factors such as ultimate load, vertical settlement, horizontal deformation and tilt were investigated. An improvement in ultimate load, vertical settlement, horizontal deformation and tilt of foundation was observed with an increase in the percentage of fibers used and thickness of reinforced sand layer under different inclinations and eccentricities of load. A statistical model using non-linear regression analysis based on present experimental data for predicting the vertical settlement ($s_p$), horizontal deformation ($hd_p$) and tilt ($t_p$) of square footing on reinforced sand at any load applied was done where the dependent variable was predicted settlement ($s_p$), horizontal deformation ($hd_p$) and tilt ($t_p$) respectively.

Load-Settlement Characteristics of Concrete TOP-BASE Foundation on Soft Ground (팽이기초공법(Top-Base Method)의 하중-침하량 분석)

  • Kim, Jae-Young;Jeong, Sang-Seom;Lee, Jae-Hwan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.210-221
    • /
    • 2009
  • A new foundation type which is called Top-Base method has been used frequently in engineering practices in Korea. In this study, the settlement behavior of concrete Top-Base foundation on soft ground is investigated since the consolidation settlement of the embedding depth and the effect of footing dimensions are not included in current Korean criterion (2007). To obtain detailed information, the model tests of the Top-Base foundation are performed using the PLAXIS 3D finite element analysis. It is shown that in-situ measurements and finite element analysis of the behavior of foundations indicate that consolidation settlement is reduced up and bearing capacity of the foundation increases up to 50%~100%, compared to the primary non-treated ground. Based on this study, it is found that the Top-Base foundation prevents the lateral deformation of soft ground and reduces its negative dilatancy to the surface settlement, and that the foundation creates rather uniform stress distribution under it to increase its bearing capacity. It is also found that the total settlement of Top-Base foundation was highly dependent on the consolidation settlement and footing configurations.

  • PDF

Estimation Of Footing Settlement In Sand (사질토 지반에서의 얕은기초 침하량 해석)

  • Lee, Jun-Hwan;Park, Dong-Gyu
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.44-49
    • /
    • 2004
  • The settlements of footings in send are often estimated based on the results of in-situ tests, particularly the standard penetration test (SPT) and the cone penetration test (CPT). In this paper, we analyze the load-settlement response of vertically loaded footings placed in sands using both the finite element method with a non-linear stress-strain model and the conventional elastic approach. Calculations are made for both normally consolidated and heavily overconsolidated sands with various relative densities. For each case, the cone penetration resistance qc is calculated using CONPOINT, a widely tested program that allows computation of qc based on cavity expansion analysis. Based on these analyses, we propose a procedure for the estimation of footing settlement in sands based on CPT results.

  • PDF

Seismic bearing capacity of shallow footings on cement-improved soils

  • Kholdebarin, Alireza;Massumi, Ali;Davoodi, Mohammad
    • Earthquakes and Structures
    • /
    • v.10 no.1
    • /
    • pp.179-190
    • /
    • 2016
  • A single rigid footing constructed on sandy-clay soil was modeled and analyzed using FLAC software under static conditions and vertical ground motion using three accelerograms. Dynamic analysis was repeated by changing the elastic and plastic parameters of the soil by changing the percentage of cement grouting (2, 4 and 6 %). The load-settlement curves were plotted and their bearing capacities compared under different conditions. Vertical settlement contours and time histories of settlement were plotted and analyzed for treated and untreated soil for the different percentages of cement. The results demonstrate that adding 2, 4 and 6 % of cement under specific conditions increased the dynamic bearing capacity 2.7, 4.2 and 7.0 times, respectively.

Numerical Analysis on the Size Effect of a Footing (기초의 크기효과에 관한 수치해석)

  • Lee, Seung-Hyun;Han, Jin-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.1
    • /
    • pp.778-784
    • /
    • 2015
  • Finite element analyses were conducted to investigate the size effect on the bearing capacity and settlement of shallow foundations, and the results were compared with those of theoretical equations. The calculated bearing capacity of the plate by numerical analysis and the theoretical equation was similar. Numerical analyses showed that the ultimate bearing capacity of strip footing on sand was affected by the size effect, whereas the ultimate bearing capacity of strip footing on clay was not affected by the size effect. Numerical analyses showed that the square footing was unaffected by the size effect regardless of the type of foundation soil. In contrast to theoretical equations, settlement of the footing was affected by the size effect and was proportional to the footing width.

Elastic settlements of identical angular footings in close proximity

  • R. Sarvesha;V. Srinivasan;Anjan Patelb
    • Geomechanics and Engineering
    • /
    • v.32 no.2
    • /
    • pp.193-207
    • /
    • 2023
  • In general, the numerous classical approaches available in the literature can anticipate the settlement of shallow foundations. As long as the footings are not in close proximity to other subsurface buildings, the findings achieved using these methods are legitimate and acceptable. However, due to increased urbanisation and land scarcity, footings are frequently built close together. As a result, these footings' settlement behaviour differs from those of isolated footings. A simpler approach for assessing the settlement behaviour of two square or rectangular footings placed in close proximity is presented in this work. A Parametric study has been carried out to examine the interference effect on the settlement of these footings placed in close vicinity on the surface of a homogeneous, isotropic and elastic soil medium. The interaction factors are examined by varying the different aspect ratios (L/B), clear spacing ratio (S/B) and intensity of loading on the right footing with respect to the left footing. Further, variation of the settlement ratio (δ/B) with respect to embedment depth ratio Df/B is examined. For square and rectangular footings, the interference settlement profile is also investigated by varying the clear spacing ratio (S/B) and the degree of loading. The results were compared to 3D finite element analysis and experimental data that were available.