• Title/Summary/Keyword: foot angle

Search Result 590, Processing Time 0.022 seconds

A Study on the Analysis of Foot Shape (I) -on Classification of Foot Type- (발의 형태분석에 관한 연구(I) -발의 형 분류를 중심으로-)

  • Moon Myeng-ok;Kwon Young-suk
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.12 no.1 s.26
    • /
    • pp.45-52
    • /
    • 1988
  • To classify the foot type, direct measurements, metatarso-phalanx angle and foot print angle of the right and left foot were measured and analyzed. The results are as follows. 1. The correlation coefficients between right and left foot were high degree, and except medial malleous height, the diffences between right and left foot are not significant. 2. The correlation coefficient among direct measurements of the foot are high degree, tut the correlation coefficients between direct measurements and metatarso-phalanx angle and foot print angle are no or low degree. Therefore, to recognize the foot type, the direct measurements, metatarso-phalanx angle and foot print angle need to be measured independently. 3. According to foot width/foot $length{\times}100$ which is the slender degree of foot, three groups are distinguished: one is slender type of which foot width/foot $length{\times}100$ is less than $40.14\%$, two is standard type of which foot width/foot $length{\times}100$ is $40.14\%{\~}44.30\%$, three is broad type of which foot width/foot $length{\times}100$ is more than $44.30\%$. 4. On the photographs metatarso-phalanx angle was measured, and two groups are distinguished: one is normal type of which the metatarso-phalanx angle is more than $160^{\circ}$ and the other is the deformed type of which the metatarso-Phalanx angle is less than $159^{\circ}$. 5. By foot print angle $30^{\circ}$ which need reformation of the foot, two groups are distinguished: one is normal foot print angle of which the angle is more than $30^{\circ}$ and the other is flat foot print angle of which the angle is less than $30^{\circ}$. 6. Classifications by foot width/foot $length{\times}100$, metatarso-Phalanx angle and foot Print angle are put together, and then foot types are classified into 12 groups such as Table 11.

  • PDF

Cluster Analysis for Foot Type (II) -The subject of the college men between the age of 19~24 years- (발의 형태 분석을 위한 군집분석(II) -19~24세 남자대학생을 중심으로-)

  • 문명옥
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.18 no.5
    • /
    • pp.637-645
    • /
    • 1994
  • The purpose of this study was to analyze the characteristics of men's foot and the foot type by cluster analysis for men's footwear. The sample size for the study was 200 college men between age 19 and 24 in Pusan urban area. There were measured 17 items of the foot for factor analysis and cluster analysis. The result was as follows: 1. The size of If items of men's foot is larger than women's foot. 2. There were 9 items selected by factor analysis. 3. The cluster analysis of the direct measurement: Cluster 1: The items of the direct measurement is all much the same to mean value of this age group. Cluster 2: The foot size is relatively small to other clusters. Cluster 3: The foot size is relatively large to other clusters. 4. The cluster analysis of indirect measurement: Cluster 1: The foot print angle is the most value and Metatarso-Phalanx angle is nomral Cluster 2: The foot print angle is middle and Metatarso-Phalanx angle is normal. Cluster 3: The foot print angle is high and Metatarso-Phalanx angle is the smallest. Cluster 4: The foot print angle is low and Metatarso-Phalanx angle is all the much same to mean value of this age group.

  • PDF

Study of Suitable Angle of Tibia-Foot and X-ray Tube for Navicular in Foot X-ray Examination (족부 X선 검사에서 주상골 관찰에 용이한 Tibia-Foot angle과 X-ray tube 각도에 대한 연구)

  • Moon, Joo-Wan;Han, Jae-Bok;Choi, Nam-Gil
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.39-46
    • /
    • 2018
  • The purpose of this study was to determine suitable angle of Tibia-foot and the X-ray tube for scaphoid in foot X-ray examination. A total of twenty patients(mean age $32.12{\pm}years)$ are participated in this study. In the positions of Foot AP, internal and external oblique, tibia-foot angle was defined as $90^{\circ}$ and $135^{\circ}$, and x-ray tube angle was defined as $0^{\circ}$, $5^{\circ}$, $10^{\circ}$, $15^{\circ}$ and $20^{\circ}$ respectively. The image quality was evaluated with blind test yielding scores ranging from 0 to 5 by the evaluation team consisted of 2 radiogical technologists, 2 radiologists, and 2 orthopedic surgeons. In case of Foot AP position, the degree of overlap between cuneiform and navicular was 3% and the blind test result was 4.89 at tibia-foot angle of $90^{\circ}$ and $15^{\circ}$ X-ray tube angle. When the tibia-foot angle is $135^{\circ}$, the degree of overlap was 5%, also the blind test result was 4.30 at $15^{\circ}$ X-ray tube angle. The degree of overlap and blind test result were 30% and 3.75 respectively at $0^{\circ}$ X-ray tube angle. In case of internal oblique position, at tibia-foot angle of $90^{\circ}$ and $0^{\circ}$ X-ray tube angle, the degree of overlap was 4% and the blind test result was 4.70. The 5% overlapping and highest score as 4.55 were obtained on tibia-foot angle of $135^{\circ}$ and $0^{\circ}$ X-ray tube angle. In case of external oblique position, at tibia-foot angle of $90^{\circ}$ and $15^{\circ}$ X-ray tube angle, the degree of overlap was 4% and the blind test score was 4.85. The 5% overlapping and highest score as 4.75 were obtained on tibia-foot angle of $135^{\circ}$ and $15^{\circ}$ X-ray tube angle. In conclusion, we confirmed suitable angle of tibia-foot and X-ray tube for scaph46oid in foot X-ray examination in this study. These findings will be helpful for us to reading for navicular fracture.

The Analysis of Foot Shape of Elementary School Boys (학령기 남아의 발 형태 분석)

  • Seok, Eun-Yeong;Jeon, Eun-Gyeong;Park, Sun-Ji;Gwon, Suk-Hui
    • Journal of the Ergonomics Society of Korea
    • /
    • v.23 no.2
    • /
    • pp.1-12
    • /
    • 2004
  • The purposes of this study were to investigate the relationship between anthropometric data of foot and other body sizes. to categorize the foot shape of elementary school boys and to find out determinant factors related the foot that enable us to deduce the foot shape and size for the design of more comfortable shoes. Subjects of this study were 249 elementary school boys of age ranged from 6 to 11 residing Seoul and lncheon area. Anthropometric sizes were measured with the direct measurement method using Martin scales and the indirect measurement method using digital photos. Pearson's correlation, factor analysis. cluster analysis. analysis of variance, post-hoc test, and cross tabs were performed for statistical analysis of the data by SPSS program. From the investigation on the relationship between foot-related items and body items, most items of foot measure were significantly related to body size items. However, angle of the foot did not related to other body sizes although other height items and mass items of the foot did have relationships with other body sizes. Results of ANOVA indicated there were significant differences in foot-related items except for items of foot angle and all body anthropometric items by subjects' age. This implicates big toe angle, little toe angle and foot ratio factors are required in sizing shoes besides foot length. On the basis of cluster analysis using factor scores. three different foot shapes were categorized. Type 1 was large and wide foot, Type 2 was small and narrow foot with large toe angle. and Type 3 was medium foot with no deformity on big toe. These three groups show significant differences in almost all measurement items. However, Rorher index and foot angle didn't show any significant differences among groups. This implicates the foot shape can be a determinant of shoe size.

Cluster Analysis for Foot Type(I) - The subject of the college women between the age of 19~23 years - (발의 형태 분석을 위한 군집분석(I) - 19~23세 여자 대학생을 중심으로 -)

  • 문명옥
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.18 no.2
    • /
    • pp.211-220
    • /
    • 1994
  • The purpose of this study was to analyze the foot type by cluster analysis for footwear. The sample size for the study was 200 college womens between age 19 and 23 in Pusan urban area. There were measured 17 items of the foot for factor analysis and cluster analysis. The result was as follows : 1. 1'here were 9 items selected by factor analysis. 2.'rho cluster analysis of the foot must be analyzed by direct and indirect measurement indivisually. 3. The cluster analysis of the direct measurement ; Cluster 1 : 1'he foot length is all much the same to mean value of this age group and the items of width and circumference are relatively small to other clusters. Cluster 2 ; The foot length is relatively small to other clusters and the items of width and circumference are all much the same to mean value of this age group. Cluster 3 ; The foot sine Is relatively large to other clusters. 4. The cluster analysis of indirect measurement ; Cluster 1 ; The (cot print angle is high find Metatarso-Phalanx angle is transformed Cluster 2 ; The foot print angle is low and Melatarso-Phalanx angle is normal. Cluster 3 : Tho foot print angle Is middle and Metatarso-Phalanx angle is all the mush same to mean value of this age group. Cluster 4 . The foot print angle Is the most value and Metatarso-Phalanx angle is normal.

  • PDF

The Effect of Low Back Pain and Pelvic Displacement on Foot Orthosis (발 보조기 착용이 요통환자의 골반 변위와 통증 변화에 미치는 영향)

  • Lee, Wan-Hee;Park, Dae-Sung
    • Journal of Korean Physical Therapy Science
    • /
    • v.12 no.4
    • /
    • pp.57-67
    • /
    • 2005
  • The purpose of this study is to investigate the effect of low back pain(LBP) and pelvic displacement on foot orthosis. Before and after experiments were designed to compare the effect. 21 LBP patients who were the subjects diagnosed of applying foot orthosis for 3 weeks after, investigated about pelvic obliquity angle, displacement of ilium, lumbo-sacral angle by x-ray test which is one of pelvic displacement tests, visual analogue scale is used for LBP measurement. The result show the followings; First, Pelvic obliquity angle was significantly reduced after applying foot orthosis compared before using it(p<.05). Second, Displacement of ilium was significantly reduced after applying foot orthosis compared before using it(p<.05). Third, Lumbo-sacral angle was significantly reduced after applying foot orthosis compared before using it(p<.05). Fourth, LBP was significantly reduced after applying foot orthosis compared before using it(p<.05). This study tries to suggest new LBP treatment to reduce pelvic displacement by apply foot orthosis. In conclusion, foot orthosis reduces pelvic obliquity angle, displacement of ilium, lumbo-sacral angle and also decrease LBP. Further more, It needs of biomechanical study which can recognize relation between foot arch and pelvic displacement. This study will serve as a clinically useful data for diagnosis and treatment of LBP and biomechanical analysis of lower limb.

  • PDF

Study on Change of the Flatfoot's Ankle Angle in Sagittal plane before and after Wearing FFO (기능성 발보조기 착용 전후의 시상면의 편평족 발목각도 변화에 관한 연구)

  • Park, K.Y.;Park, S.H.
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.1
    • /
    • pp.67-73
    • /
    • 2010
  • The foot performs an important function in supporting the body and keeping body balance. An abnormal walking habit breaks the balance of the human body as well as the normal function of the foot. The influence of a flatfoot(pes planus) occupies a considerable portion of the various causes resulting in the wrong walking habit. But, little studies has been done by the functional foot orthotics for the flat foot. The object of this study, therefore, is to propose a new approach method to reveal the effects of the improvement of the foot function by using orthotics. The essential point of this study is to measure and analyze the change of ankle angle in the sagittal plane for flat foot subjects wearing the orthotics. Before and after wearing the functional orthotics, the gait analysis of flat foot subjects was conducted in three experimental aspects : the change of ankle angle, the change of the total Ankle ROM and the difference of left & right ankle angle in the sagittal plane. 1. The average ankle angle differences of before-and-after wearing the orthotics have declined like this; left : $2.71^{\circ}$, right: $1.91^{\circ}$ (p<0.05). 2. Total ankle ROM also showed decrease in both sides while the left side's is rather slight; left : $0.57^{\circ}$, right : $2.07^{\circ}$ (p<0.05). 3. The difference of left and right ankle angle in the sagittal plane decreased by $0.71^{\circ}$ (p<0.05). In result, it is confirmed that the functional foot orthotics have a significant effect on mechanical movement of ankle joint for flat foot. it is expected that this paper will be further studied and improved as a practical estimation method in the research on the effect of foot-orthotics.

The Application of Foot Orthotic to Chronic Pain Patient with Pelvic Obliquity : 4 Cases Report (골반 경사가 동반된 만성 통증 환자에게 족부 보조기를 적용한 증례 4례)

  • Ahn, Hee-Bin;Kim, Soon-Joong;Jeong, Su-Hyeon
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.21 no.2
    • /
    • pp.309-318
    • /
    • 2011
  • Objectives : To evaluate the effect of foot orthotic in patient with chronic pain and pelvic obliquity in standing. Methods : Four cases of functional spinal scoliosis, were investigated for the changes in the calcaneal stance position angle, pelvic height, pelvic angle, Cobb's angle and walking pattern. Standing full spine X-ray for measuring the pelvic height, pelvic angle, Cobb's angle were checked before and after application of foot orthosis. The foot orthosis was composed of polyprophylen and chamude cover. Results : 1. There was no change in resting calcaneal stance position. 2. Difference of pelvic height and pelvic angle was reduced after application of a foot orthosis. 3. Cobb's angle in 2 cases was reduced after application of a foot orthosis. 4. Walking balance was improved. 5. Visual analogue scale was decreased. Conclusions : The study showed that foot orthosis seemed to be effective for chronic pain, spinal curve, pelvic obliquity and walking balance.

Change of Radiologic Index of Foot according to Radiation Projection Angle: A Study Using Phantom Foot (방사선 투과 각도에 따른 족부 방사선 지표의 변화: Phantom Foot을 이용한 연구)

  • Kim, Eo Jin;Seo, Sang Gyo;Lee, Dong Yeon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.19 no.4
    • /
    • pp.165-170
    • /
    • 2015
  • Purpose: The purpose of this study is to analyze the measurement differences of simple radiographs according to radiation projection angle using a phantom and to propose methods for objective analysis of simple radiographs. Materials and Methods: We took simple radiographs with different projection angles using a C-arm image intensifier and measured five parameters of the foot on the simple radiographic images. Five parameters include lateral tibiocalcaneal angle, lateral talocalcaneal angle, naviculocuboid overlap, lateral talo-first metatarsal angle, and lateral calcaneo-first metatarsal angle. Intraobserver and interobserver reliability were verified, and then intraclass correlations of parameters were analyzed. Results: Radiographic parameters of the foot showed high intraobserver and interobserver reliability. Lateral tibiocalcaneal angle has a strong negative linear relationship with rotation and a moderate negative linear relationship with tilt. Lateral talocalcaneal angle has a moderate positive linear relationship with rotation and a strong positive linear relationship with tilt. Naviculocuboid overlap has a strong positive linear relationship with rotation and a moderate positive linear relationship with tilt. Lateral talo-first metatarsal angle does not have a linear relationship with rotation and a moderate negative linear relationship with tilt. Lateral calcaneo-first metatarsal angle has a moderate positive linear relationship with rotation and tilt. Conclusion: More precise evaluation of the foot with a simple radiograph can be performed by understanding the changes of radiographic parameters according to radiation projection angle.

Characteristics of Knee Joint Flexion Angle and Foot Pressure according Slope Climbing (경사로 오르기 동안 슬관절 굴곡각도와 족저압의 특성 비교)

  • Oh, Tae-Young;Song, Hyeon-Ju;Lee, Seul-Gi;Jung, Ye-Ji;Lim, Jong-Su
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.2
    • /
    • pp.268-276
    • /
    • 2010
  • This study was to investigate the knee joint flexion angle and the foot pressure during climbing with different slope. The 24 healthy subjects were participated. And foot pressure was investigated using Parotec system. The knee joint flexion angle were filmed to using a video camera on each slope($0^{\circ},\;3^{\circ},\;6{\circ},\;9^{\circ}$). And knee joint angle was investigated by Dartfish. The data were analyzed ANOVAs. In conclusion, there was significantly different that knee joint flexion angle related on each slope angle. In foot pressure, there was significantly different in lateral heel area(1 cell), medial midfoot area(9 cell), medial forefoot area(15, 16 cell) of left foot, and in lateral heel area(3 cell) of right foot. There was significantly different of foot pressure in lateral and medial heel when knee joint flexion angle is between $10^{\circ}$ and $20^{\circ}$. There was change of gait cycle according to walking slop angle increasing, and the initial contact phase was shorter, the foot pressure in lateral heel was lower.