• Title/Summary/Keyword: foil system

Search Result 188, Processing Time 0.026 seconds

The Salt Removal Efficiency Characteristics of Carbon Electrodes Using Fabric Current Collector with High Tensile Strength in a Capacitive Deionization Process (인장강도가 뛰어난 직물집전체를 이용한 탄소전극의 축전식 탈염공정에서의 제염효과)

  • Seong, Du-Ri;Kim, Dae Su
    • Korean Chemical Engineering Research
    • /
    • v.58 no.3
    • /
    • pp.466-473
    • /
    • 2020
  • Fabric current collector can be a promising electrode material for Capacitive Deionization (CDI) system that can achieve energy-efficient desalination of water. The one of the most attractive feature of the fabric current collector is its high tensile strength, which can be an alternative to the low mechanical strength of the graphite foil electrode. Another advantage is that the textile properties can easily make shapes by simple cutting, and the porosity and inter-fiber space which can assist facile flow of the aqueous medium. The fibers used in this study were made of woven structures using a spinning yarn using conductive LM fiber and carbon fiber, with tensile strength of 319 MPa, about 60 times stronger than graphite foil. The results were analyzed by measuring the salt removal efficiency by changing the viscosity of electrode slurry, adsorption voltage, flow rate of the aqueous medium, and concentration of the aqueous medium. Under the conditions of NaCl 200 mg/L, 20ml/min and adsorption voltage 1.5 V, salt removal efficiency of 43.9% in unit cells and 59.8% in modules stacked with 100 cells were shown, respectively. In unit cells, salt removal efficiency increases as the adsorption voltage increase to 1.3, 1.4 and 1.5 V. However, increasing to 1.6 and 1.7 V reduced salt removal efficiency. However, the 100-cell-stacked module showed a moderate increase in salt removal efficiency even at voltages above 1.5 V. The salt removal rate decreased when the flow rate of the feed was increased, and the salt removal rate decreased when the concentration of the feed was increased. This work shows that fabric current collector can be an alternative of a graphite foil.

A Development of SEM Applied Microjoining System (SEM을 이용한 미세 접합 시스템 개발)

  • 황일한;나석주
    • Journal of Welding and Joining
    • /
    • v.21 no.4
    • /
    • pp.63-68
    • /
    • 2003
  • Scanning electron microscopy (SEM) has been used as a surface measurement instrument and a tool for lithography in semiconductor process due to its high density localized beam. For those purposes, however, the maximum current of SEM Is less than 100pA, which is not enough fo material processing. In this paper SEM was modified to increase the amount of current reaching a specimen from gun part where current is generated, the possibility of applying SEM to material processing, especially microjoining, was investigated. The maximum current of SEM after modifications was measured up to 10$\mu$A, which is about 10$^{5}$ times greater than before modifications. Through experiments such as eutectic solder wetting on thin 304 stainless steel foil and microjoining of 10$\mu$m thick 304 stainless steel, the intensity of electron beam of SEM proved to be great enough fur material processing as heat source. And a tight jig system was found necessary to hold materials close enough fur successful microloining.

Development of On-line Wrinkle Measurement System Using Machine Vision (머신 비젼을 이용한 실시간 링클 측정 시스템 개발)

  • Shin, Dong-Keun;To, Hoang-Minh;Ko, Sung-Lim
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.3
    • /
    • pp.274-279
    • /
    • 2008
  • Roll to roll (R2R) manufacturing process, also known as 'web processing', has been tried for producing electronic devices on a flexible plastic or metal foil. To increase the performance and productivity the R2R process, effective control and on-line supervision for web quality becomes very important. Wrinkle is one of the defects, which is incurred due to compressive stresses. A system for on-line measurement of wrinkle is developed using area scan camera and machine vision laser. The 2D image, obtained by area scan camera, is produced by Gaussian regression method to characterize the wrinkle on a transparent web. The experiment proves that 0.3mm wrinkle height can be measured successfully with 74fps.

Hydrodynamic characteristics of cambered NACA0012 for flexible-wing application of a flapping-type tidal stream energy harvesting system

  • Sitorus, Patar Ebenezer;Park, JineSoon;Ko, Jin Hwan
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.11 no.1
    • /
    • pp.225-232
    • /
    • 2019
  • In recent years, nonlinear dynamic models have been developed for flapping-type energy harvesting systems with a rigid wing, but not for those with a flexible wing. Thus, in this study, flexible wing designs of NACA0012 section are proposed and measurements of the forces of rigid cambered wings, which are used to estimate the performance of the designed wings, are conducted. Polar curves from the measured lift and drag coefficients show that JavaFoil estimation is much closer to the measured values than Eppler over the entire given range of angles of attack. As the camber of the rigid cambered wings is increased, both the lift and drag coefficients increase, in turn increasing the resultant forces. Moreover, the maximum resultant forces for all rigid cambered wings are achieved at the same angle of attack as the maximum lift coefficient, meaning that the lift coefficient is dominant in representations of the wing characteristics.

A Finite Volume Method for Computations of Two-Dimensional Laminar Flows (이차원 층류유동 해석을 위한 유한체적법)

  • Kim, Ki-Sup;Chung, Myung-Kyoon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.29 no.3
    • /
    • pp.59-70
    • /
    • 1992
  • A Finite volume method for the computation of the two-dimensional, incompressible, steady, laminar Navier-Stokes equation is developed using a non-staggered grid system in a general curvilinear coordinate. The numerical pressure fluctuations, usually encountered when the non-staggered grid system is used, is suppressed by the momentum interpolation method. Flows around a NACA0012 foil section have been computed by the present method and the results show good agreements with other experimental and numerical ones.

  • PDF

Measurement of Micro-Tensile Properties using ESPI technique (ESPI 기법을 이용한 미소 인장 특성 추정)

  • Huh, Yong-Hak;Kim, Dong-Il;Yoon, Kyung-Jin;Kim, Koung-Suk;Oh, Chung-Seog
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.5
    • /
    • pp.90-97
    • /
    • 2001
  • An electronic speckle pattern interferometry (ESPI) system for measuring tensile properties under micro-tensile testing has been developed. The system consists of an optical system and an image processing system. In the optical system, optical components for measurement of in-plane deformation are arranged on the path of He-Ne laser. In the image processing system, the window-based program for acquiring speckle pattern interferometric image was developed and deformation in a small specimen is continuously evaluated during the test. Using this system, tensile strain of copper foil was measured during tensile testing. Tensile specimen had the thickness and width of 22 and 500 ${\mu}{\textrm}{m}$, respectively. Tensile properties, including the elastic modulus, yielding strength and tensile strength, of the copper were evaluated and also plastic exponent and coefficient in the Ramberg-Osgood relationship were evaluated from the stress-strain curve.

  • PDF

A Study on Development of a Ground-Source Heat Pump System Utilizing Pile Foundation of a Building (건물 기초를 이용한 지중열 공조시스템의 개발에 관한 연구 (1))

  • Ryozo, Ooka;Nam, Yu-Jin;Kentaro, Sekine;Mutsumi, Yokoi;Yoshiro, Shiba;Hwang, Suck-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.148-154
    • /
    • 2005
  • Ground-source (Geothermal) heat pump (GSHP) systems can achieve a higher coefficient of performance than conventional air-source heat pump (ASHP) systems. However, GSHP systems are not widespread in Japan because of their expensive boring costs. The authors have developed a GSHP system that employs the cast-in-place concrete pile foundations of a building as heat exchangers in order to reduce the initial boring cost. In this system, eight U-tubes are arranged around the surface of a cast-in-place concrete pile foundation. The heat exchange capability of this system, subterranean temperature changes and heat pump performance were investigated in a foil-scale experiment. As a result, the average values for heat rejection were 186${\sim}$201 W/m (for pile, 25 W/m per Pair of tubes) while cooling. The average COP of this system was 4.6 while cooling; rendering this system more effective in energy saving terms than the typical ASHP systems. The initial cost of construction per unit for heat extraction and rejection is ${\yen}$72/W for this system, whereas it is f300/W for existing standard borehole systems.

  • PDF

Comparison of discharging electrodes for the electrostatic precipitator as an air filtration system in air handling units (에어핸들링 유닛의 공기정화용 전기집진기의 방전극 비교)

  • Shin, Dongho;Woo, Chang Gyu;Kim, Hak-Joon;Kim, Yong-Jin;Han, Bangwoo
    • Particle and aerosol research
    • /
    • v.13 no.1
    • /
    • pp.11-16
    • /
    • 2017
  • Indoor air quality is of increasing concern because it is closely related human health. An air handling unit (AHU) can be used to control the indoor air quality related to particulate matters and $CO_2$ as well as air conditioning such as temperature and humidity of indoor air. An electrostatic precipitator has a high collection efficiency and low pressure drop, however, ozone can possibly generate from its chargers, which is one of drawbacks to apply it for indoor air control. Here we compared four charging electrodes such as a $50{\mu}m$ tungsten wire, a $100{\mu}m$ tungsten wire, a $16{\mu}m$-thickness Al foil and a carbon fabric comprised of $5-10{\mu}m$ fibers. The carbon fabric electrode showed a superior particle collection efficiency and a lower ozone generation at a given power consumption compared to tungsten wires of 50, $100{\mu}m$ and an Al foil electrode. This low ozone generating, micro-sized electrode can be applied to the electrostatic precipitator in AHU for indoor air control.

Design of Hard Coating Resin for In-mold Decoration (IMD) Foil and Effects of EB Irradiation on IMD Foil Layers (In-mold Decoration(IMD) 포일용 경질 코팅 수지 설계 및 전자빔 조사가 IMD 포일 구성층에 미치는 영향)

  • Sim, Hyun-Seog;Kim, Geon-Seok;Shin, Ji-Hee;Lee, Kwang-Hee
    • Polymer(Korea)
    • /
    • v.36 no.3
    • /
    • pp.268-274
    • /
    • 2012
  • The silane coupling agent, 3-(trimethoxysilyl)propyl methacrylate (${\gamma}$-MPTS), was grafted on the surface of alumina nanoparticles. We used the surface modified nanoparticles in the hard coating layer for in-mold decoration (IMD) foils and evaluated the coating properties such as hardness and anti-abrasion property. The effects of electron beam (EB) irradiation on color layer and anchor layer of IMD foils were observed through the difference in color and the cross-cut tape test, respectively. Also, cure kinetics as studied quantitatively under various reaction temperatures by analysis of surface properties and Fourier transform infrared (FTIR) spectroscopy. From these results, we constructed database for the commercial exploitation of EB curing system.

A comparison of marginal fit of glass infiltrated alumina copings fabricated using two different techniques and the effect of firing cycles over them

  • Bhowmik, Hirasankar;Parkhedkar, Rambhao
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.4
    • /
    • pp.196-203
    • /
    • 2011
  • PURPOSE. This study evaluated marginal fit of glass infiltrated alumina cores fabricated using two techniques and their marginal stability after firing cycles of veneering porcelain. MATERIALS AND METHODS. Fifteen standardized all-ceramic crowns were fabricated on a metal die using each technique: slip cast technique of VITA In-Ceram sprint Alumina (Group A as control) and plastic foil matrix technique of Turkom-Cera fused alumina core system (Group B). Copings were compared between groups and within groups at coping stage and after firing each layer of veneering porcelain. A device was used to standardize seating of copings on the metal die and positioning of the specimens under the microscope after each stage of fabrication. The specimens were not cemented and marginal gap was measured using an image analyzing software (Imagepro Express) on the photographs captured under an optical microscope. Two tailed unpaired 't test' was used to compare marginal gaps in two groups and one way ANOVA was used to analyze marginal distortion within each group at 95% confidence interval. RESULTS. The marginal gap was smaller at the coping stage in group B ($60+30{\mu}M$) than group A ($81+21{\mu}M$) with statistical significance. After firing of veneering porcelain the difference was insignificant. At the final stage, both groups exhibited lower mean marginal gaps than at the initial coping stage with the difference of $11.75{\mu}M$ for group A and $11.94{\mu}M$ for group B, but it was statistically insignificant due to high value of standard deviation. CONCLUSION. Within the limitations of this study, it was concluded that both techniques produced copings with comparable and acceptable marginal fit and marginal stability on firing veneering porcelain.