• 제목/요약/키워드: foamed cellular concrete

검색결과 3건 처리시간 0.019초

Analytical model of stress-strain curve for foamed cellular concrete in compression

  • Facundo A. Retamal;Viviana C. Rougier
    • Advances in materials Research
    • /
    • 제13권5호
    • /
    • pp.355-374
    • /
    • 2024
  • Several mathematical models describe the compressive behaviour of different types of concretes, but no specific one for foamed cellular concrete (FCC) has been developed. In this work, simple compression tests on FCC specimens of different mixes were conducted to study this material's compression behaviour curve until failure. Using continuous load and displacement measurement equipment, it was possible to obtain stress-strain curves up to peak for FCC of different strengths (from 1.20 to 47.34 MPa). Elastic modulus, compressive strength and failure strain values were also determined. Through the analysis of the mentioned curves, a mathematical model of them was obtained, through which it is possible to describe the compression behaviour of FCC up to failure. The comparison between the predicted curve against experimental data shows the effectiveness of the proposed model.

양생온도에 따른 다공성 경량골재를 활용한 샌드위치 패널심재의 강도 특성 (Strength Properties of Sandwich Panel core using Cellular lightweight Aggregate according to Curing Temperature)

  • 노정식;김대규;도정윤;문경주;소양섭
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.35-38
    • /
    • 2003
  • The purpose of this study is to investigate the manufacture of light weight concrete panel using the artificial light-weight aggregate as a part of the substitution of foamed styrene and polyurethane because of narrow allocable temperature Bone in use. The experimental parameter of this study is 40, 60 and 8$0^{\circ}C$ of curing temperature at 100% relative humidity and the type of admixture such as cement, 6mm glass fiber and St/BA emulsion. Testing item is compressive and flexural strength and strength of specimen cured at standard condition is compared to that of specimen cured at 40, 60 and 8$0^{\circ}C$ of curing temperature at 100% relative humidity. As a result or this, it was revealed that the maximum or strength is developed in 6$0^{\circ}C$ or cure temperature at 100% relative humidity in case of the most of the specimen. Specimens modified by St/BA emulsion show the highest development of strength dependent on the curing tmeperature. So, it seems to be effective that evaporation curing method shoud be considered to curing the specimen as the panel core.

  • PDF

건조수축에 따른 균열 억제를 위한 규사 혼입 CLC의 특성 (Properties of CLC using Silica to Suppress Cracking due to Drying Shrinkage)

  • 이창우;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.125-126
    • /
    • 2021
  • In order to improve the housing culture, construction changes for the utilization of diverse and multifunctional spaces are appearing in response to the increasing diverse needs of consumers. Cellular Light-weight Concrete (CLC) is being developed for use in fire-resistant heat-insulating walls and non-bearing walls. However, manufacturing non-uniformity has become a problem as a drawback due to the use of foamed bubbles and normal temperature curing, and additional research is required. Therefore, in order to suppress cracks due to drying shrinkage, silica sand is mixed with CLC to try to understand its characteristics. In the experiment, the compressive strength from 7 to 28 days of age was measured via a constant temperature and humidity chamber, and the drying shrinkage was analyzed according to each condition using a strain gauge. The compressive strength of matrix tends to decrease as the substitution rate of silica sand increases. This is judged by the result derived from the fact that the specific surface area of silica sand is smaller than that of slag. Based on KS F 2701 (ALC block), the compressive strength of 0.6 products is 4.9 MPa or more as a guide, so the maximum replacement rate of silica sand that satisfies this can be seen at 60%. Looking at the change in drying shrinkage for just 7 days, the shrinkage due to temperature change and drying is 0.7 mm, and the possibility of cracking due to shrinkage can be seen, and it seems that continuous improvement and supplementation are needed in the future.

  • PDF