• Title/Summary/Keyword: flux switching

Search Result 204, Processing Time 0.029 seconds

Characteristics of the magnetic flux-offset type FCL by switching component

  • Jung, Byung-Ik;Choi, Hyo-Sang
    • Progress in Superconductivity and Cryogenics
    • /
    • v.18 no.2
    • /
    • pp.18-20
    • /
    • 2016
  • The study of superconducting fault current limiter (SFCL) is continuously being studied as a countermeasure for reducing fault-current in the power system. When the fault occurred in the power system, the fault-current was limited by the generated impedance of SFCLs. The operational characteristics of the flux-offset type SFCL according to turn ratios between the primary and the secondary winding of a reactor were compared in this study. We connected the secondary core to a superconductor and a SCR switch in series in the suggested structure. The fault current in the primary and the secondary winding of the reactor and the voltage of the superconductor on the secondary were measured and compared. The results showed that the fault current in the load line was the lowest and the voltage applied at both ends of the superconductor was also low when the secondary winding of the reactor had lower turn ratio than the primary. It was confirmed based on these results that the turn ratio of the secondary winding of the reactor must be designed to be lower than that of the primary winding to reduce the burden of the superconductor and to lower the fault current. Also, the suggested structure could increase the duration of the limited current by limiting the continuous current after the first half cycle from the fault with the fault current limiter.

A Study on the Comparison of SRMs with 3 Rotor Poles (3개의 회전자 극을 갖는 SRM의 비교 연구)

  • Bae, Jun-Kyung;Oh, Seok-Gyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.5
    • /
    • pp.92-97
    • /
    • 2014
  • The SRM is a doubly salient, singly excited machine. The torque is developed by the tendency for the magnetic circuit to adopt a configuration of minimum reluctance, i.e. for the rotor to move into in line with the stator poles and to maximize the inductance of the coils excited. It is common practice to combine them into groups of poles which are excited simultaneously; for example, 8/6 SRM (8 stator poles and 6 rotor poles) for 4 phases, 6/4, 12/8 SRM for 3 phases, 4/2, 6/3 SRM for 2 phases. Small number of phases in two-phase SRMs allows more cost savings with regards to the switching devices in the converter. The stator back irons of two phase 6/3 SRM and C-core 4/3 SRM does not experience any flux reversal as the flux is in the same direction whether phase A or B is excited. In this study, the similarities, the differences, and structural characteristics between the two SRMs was studied, The magnetic analysis also has been carried out by the finite element method analysis (FEM).

SVPWM Method for Multi-Level System with Reduced HDF (저감된 HDF를 갖는 멀티-레벨 인버터를 위한 새로운 SVPWM 기법)

  • 김동현
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.343-346
    • /
    • 2000
  • In most inverter/converter applications SVPWM method is the preferred approach for it shows good characteristics in linear modulation range and waveform quality. in this paper we propose a new carrier based SVPWM method for multi-level system. First we survey the conventional carrier based SVPWM method and investigate the problem of the conventional one for the multi-level system with the focus on the switching frequency harmonic flux trajectories. Finally we propose a new carrier based SVPWM method that can reduce harmonic distortion. Simulation and experimental results are given for the verification of the proposed SVPWM method.

  • PDF

An Analysis of Capacitance for a 2 MVA Mold Transformer (2MVA 몰드 변압기의 정전용량 계산)

  • Jang, Hyeong-Taek;Chung, Hyun-Koo;Kim, Yong-Bae;Woo, Sung-Hyun;Shin, Pan-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.674_675
    • /
    • 2009
  • 수치해석을 사용하여 2MVA 몰드 변압기의 정전용량을 시뮬레이션(FLUX 2D)하고 계산하였다. 산출한 정전 용량 값을 변압기 모델링 회로에 적용하여 switching surge 등 이상전압이 인가되었을 때 변압기 내부에 있는 권선들의 전압분포를 예상하고 절연설계에 적용 할 수 있음을 보였다.

  • PDF

Analysis of Electromagnetic Repulse Forces of MCCB (배선용 차단기의 전자 반발력에 관한 연구)

  • 김길수;임기조;강성화;조현길
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.593-596
    • /
    • 2001
  • It is necessary for calculation of repulsion forces acting on the closed electric contacts flowing over-current, e.g. inrush current and overload currents, to do optimum design of switching devices. In this paper, the farces and flux densities generated by currents at the contact point when circuit breakers are in closed state are obtained by using 3D finite element methode. To be convinced of the results, we measure electrogmanetic repulsion forces on contacts by measuring voltage between opened contacts in MCCB.

  • PDF

The P/PI Mode Switching Method of Closed Loop Gopinath Flux Observer for Sensorless Control of Induction Motors (유도전동기 센서리스 제어를 위한 폐루프 고피나스 자속관측기의 P/PI모드 전환 기법)

  • Kang, Myeong-Kyu;Choi, Jong-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2015.11a
    • /
    • pp.67-68
    • /
    • 2015
  • 본 논문은 폐루프 고피나스 자속관측기의 P/PI모드를 전환하여 전환점부근 저속에서 모터상수 변동에도 강인한 센서리스 벡터제어가 가능한 전환기법을 제안하였다.

  • PDF

A High-Performance Position Sensorless Control System of Reluctance Synchronous Motor with Direct Torque Control (직접토크제어에 의한 위치검출기 없는 리럭턴스 동기전동기의 고성능 제어시스템)

  • 김민회;김남훈;백원식
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.1
    • /
    • pp.81-90
    • /
    • 2002
  • This paper presents an Implementation of digital high-performance position sensorless control system of Reluctance Synchronous Motor(RSM) drives with Direct Torque Control(DTC). The system consists of stator flux observer, speed and torque estimator, two digital hysteresis controllers, an optimal switching look-up table, Insulated Gate Bipolar Transistor(IGBT) voltage source inverter, and TMS320C31 DSP board. The stator flux observer Is based on the combined voltage and current model with stator flux feedback adaptive control of which inputs are current and voltage sensed on motor terminal for wide speed range. In order to prove the suggested sensorless control algorithm for industrial field application, we have some simulation and actual experiment at low and high speed range. The developed high-performance speed control by fully digital system are shown a good response characteristic of control results and high performance features using 1.0[kW] RSM having 2.57 reluctance ratio of $L_d/L_q$.

Improved Current Source Design to Measure Induced Magnetic Flux Density Distributions in MREIT

  • Oh Tong-In;Cho Young;Hwang Yeon-Kyung;Oh Suk-Hoon;Woo Eung-Je;Lee Soo-Yeol
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.1
    • /
    • pp.30-37
    • /
    • 2006
  • Injecting currents into an electrically conducting subject, we may measure the induced magnetic flux density distributions using an MRI scanner. The measured data are utilized to reconstruct cross-sectional images of internal conductivity and current density distributions in Magnetic Resonance Electrical Impedance Tomography (MREIT). Injection currents are usually provided in a form of mono-polar or bi-polar pulses synchronized with an MR pulse sequence. Given an MRI scanner performing the MR phase imaging to extract the induced magnetic flux density data, the current source becomes one of the key parts determining the signal-to-noise ratio (SNR) of the measured data. Since this SNR is crucial in determining the quality of reconstructed MREIT images, special care must be given in the design and implementation of the current source. This paper describes a current source design for MREIT with features including interleaved current injection, arbitrary current waveform, electrode switching to discharge any stored charge from previous current injections, optical isolation from an MR spectrometer and PC, precise current injection timing control synchronized with any MR pulse sequence, and versatile PC control program. The performance of the current source was verified using a 3T MRI scanner and saline phantoms.

An Improvement on low Speed Operation Performances of DTC for 3-level Inverter-fed Induction Motors (3레벨 인버터로 구동되는 유도전동기 직접토크제어의 저속성능 개선)

  • Lee, Kyo-Beum;Song, Joong-Ho;Choy, Ick;Kim, Kwang-Bae;Yoo, Ji-Yoon
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.10
    • /
    • pp.693-700
    • /
    • 2000
  • A direct torque control algorithm for 3-level inverter-fed induction motors is presented. Conventional voltage selection methods provoke some problems such as stator flux drooping phenomenon and undersirable torque control appeared especially at the low speed operation. To overcome these problems, a proposed method uses intermediate voltage vectors, which are inherently generated in 3-level inverters. In the proposed algorithm, both subdivision of the basic switching sectors and applications of tntermediated voltages improve the low speed operation characteristics. This algorithm basically considers applications in which direct torque controlled induction motors are fed by 3-level inverters with low switching frequency around 500Hz. An adaptive observer is also employed to bring better responses at the low speed operation, by estimating some state-variables, motor speed and motor parameters which take a deep effect on the performance of the low speed operation. Simulation and experiment results verify effectiveness of the proposed algorithm.

  • PDF

A Study on the Integrated Simulation and Condition Monitoring Scheme for a PMSG-Based Variable Speed Grid-Connected Wind Turbine System under Fault Conditions (PMSG 적용 가변속 계통연계형 풍력발전 시스템의 통합 시뮬레이션 및 스위치 개방고장 진단기법 연구)

  • Kim, Kyeong-Hwa;Song, Hwa-Chang;Choi, Byoung-Wook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.3
    • /
    • pp.65-78
    • /
    • 2013
  • To analyze influences under open fault conditions in switching devices, an integrated simulation and condition monitoring scheme for a permanent magnet synchronous generator (PMSG) based variable speed grid-connected wind turbine system are presented. Among various faults in power electronics components, the open fault in switching devices may arise when the switches are destructed by an accidental over current, or a fuse for short protection is blown out. Under such a faulty condition, the grid-side inverter as well as the generator-side converter does not operate normally, producing an increase of current harmonics, and a reduction in output and efficiency. As an effective way for a condition monitoring of generation system by online basis without requiring any diagnostic apparatus, the estimation schemes for generated voltage, flux linkage, and stator resistance are proposed and the validity of the proposed scheme is proved through comparative simulations.