• Title/Summary/Keyword: flux ratio

Search Result 1,013, Processing Time 0.025 seconds

Experimental Study on Fuel/Air Mixing using Inclined Injection in Supersonic Flow (경사 분사에 의한 초음속 유동 연료-공기 혼합에 관한 실험적 연구)

  • Lee, Dong-Ju;Jeong, Eun-Ju;Kim, Chae-Hyoung;Jeung, In-Seuck
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.281-284
    • /
    • 2008
  • The flow of combustor in scramjet engine is supersonic speed. So residence time and mixing ratio are very important factors for efficient combustion. This study used open cavity on fuel/air mixing model and laser schlieren was carried out to investigate flow characteristics around a jet orifice and a cavity. A source of illumination has 10 ns endurance time so it can observe unsteady flow characteristics efficiently. Pressure was measured by varying momentum flux ratio. And the change of critical ignition point was observed to change of momentum flux ratio.

  • PDF

Experimental Study on Fuel/Air Mixing using Inclined Injection in Supersonic Flow (경사 분사에 의한 초음속 유동 연료-공기 혼합에 관한 실험적 연구)

  • Lee, Dong-Ju;Jeong, Eun-Ju;Kim, Chae-Hyoung;Jeung, In-Seuck
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.13 no.4
    • /
    • pp.9-15
    • /
    • 2009
  • The flow of combustor in scramjet engine has supersonic speed so that the residence time and mixing ratio are very important factors for the efficient combustion. This study used open cavity(L/D=4.8) as a fuel/air mixing model. Laser schlieren visualization and pressure measurement were carried out to observe the flow characteristics around a jet orifice and a cavity at the time of fuel injection. As a result of 10ns laser schlieren, unsteady flow which was around the cavity could be observed effectively. Pressure was measured that momentum flux ratio(J) was changed. And the change of critical ignition point could be observed by the momentum flux ratio changed.

A Comparison of the Heat Transfer Performance of Thermosyphon Using a Straight Groove and a Helical Groove

  • Han Kyuil;Cho Dong-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.12
    • /
    • pp.2296-2302
    • /
    • 2005
  • This study is focused on the comparison of heat transfer performance of two thermosyphons having 60 straight and helical internal grooves. Distilled water has been used as working fluid. Liquid fill charge ratio defined by the ratio of working fluid volume to total internal volume of thermosyphon, the inclination angle and operating temperature were used as experimental parameters. The heat flux and heat transfer coefficient are estimated from experimental results. The conclusions of this study may be summarized as follows; Liquid fill charge ratio, inclination angle and geometric shape of grooves were very important factors for the operation of thermosyphon. The optimum liquid fill charge ratio for the best heat flux were $30\%$. The heat transfer performance of helically grooved tube was higher than that of straight grooved tube in low inclination angle (less than $30^{\circ}$), but the results were opposite in high inclination angle (more than $30^{\circ}$). As far as optimum inclination angle concerns, range of $25^{\circ}\~30^{\circ}$ for a helically grooved tube and about $40^{\circ}$ for a straight grooved tube are suggested angles for the best results.

Measurements of In-phantom Neutron Flux Distribution at the HANARO BNCT Facility

  • Kim Myong Seop;Park Sang Jun;Jun Byung Jin
    • Nuclear Engineering and Technology
    • /
    • v.36 no.3
    • /
    • pp.203-209
    • /
    • 2004
  • In-phantom neutron flux distribution is measured at the HANARO BNCT irradiation facility. The measurements are performed with Au foil and wires. The thermal neutron flux and Cd ratio obtained at the HANARO BNCT facility are $1.19{\times}10^9\;n/cm^{2}s$ and 152, respectively, at 24 MW reactor power. The measured in-phantom neutron flux has a maximum value at a depth of 3 mm in the phantom and then decreases rapidly. The maximum flux is about $25\%$ larger than that of the phantom surface, and the measured value at a depth of 22 mm in the phantom is about a half of the maximum value. In addition, the neutron beam is limited well within the aperture of the neutron collimator. The two-dimensional in-phantom neutron flux distribution is determined. Significant neutron irradiation is observed within 20 mm from the phantom surface. The measured neutron flux distribution can be utilized in irradiation planning for a patient.

Characteristics of SMD and Volume Flux of Two-phase Jet Injected into Cross-flow with Various Gas-liquid Ratio and Reynolds Number (횡단 유동장의 기액비 및 레이놀즈수 변화에 따른 외부혼합형 이상유체 제트의 액적크기 및 체적유속 특성)

  • Kim, Jong-Hyun;Lee, Bong-Soo;Koo, Ja-Ye
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.2
    • /
    • pp.75-81
    • /
    • 2009
  • A study was performed to investigate the characteristics of two-phase jet injected into subsonic cross-flow using the external mixed gas blast two-phase nozzle. The shadowgraph method was adopted for the cross-flow jet visualization and PDPA system was used to measure droplet size, velocity, and volume flux. The atomization of two-phase jet is initially determined according to gas to liquid mass flow-rate ratio and the Reynolds number of cross-flows. The highest penetration trajectories of two-phase jet injected into cross-flow are governed by the momentum ratio at subsonic cross-flow. As GLR of two-phase jet injected into cross-flow increases, the droplet size decreases and the distribution area of volume flux increases. The distribution of volume flux that influenced by the counter vortex pair at the downstream of cross-flow is symmetric in shape of horseshoe.

The Degumming and Sericin Recovery of the Silk fabric Using the Electrolytic Water(II) (전해수를 이용한 견섬유 정련 및 세리신 회수(II)-분리막에 의한 세리신 농축을 중심으로-)

  • 배기서;이태상;노덕길;홍영기
    • Textile Coloration and Finishing
    • /
    • v.16 no.4
    • /
    • pp.10-18
    • /
    • 2004
  • In this work, Aqueous sericin solution was prepared by degumming process with electrolytic reduction water. Then, the microfiltration and ultrafiltration systems were applied to the concentration of aqueous sericin solution. The objective of this study was to select the optimum operating condition among the different pressure. The permeate flux and rejection ratio were observed with time, pressure, flow rate and concentration. and, the wastewater and permeated water quality values such as pH, BOD, COD, and NH levels were measured. In order to see the influence of electrolytic reduction water, the flux of pure water and electrolytic reduction water by PVDF22(MF) and PS100(UF) membrane was measured. In microfiltration system, the relative flux reduction decreased rapidly to 0.02 in the 30min, as the concentration polarization and gel layer formation were increased. and then the sericin concentration rejection ratio was 40%. In ultrafiltration system, the permeate flux decreased with time and concentration, and increased with the operating pressure and flow rate. Optimal condition in PS100 membrane system for sericin concentration was operating pressure 1.464kgf/$cm^24, operating flow rate $7\ell/min at\; 40^{\circ}C$. At that time, sericin concentration rejection ratio was 83% respectably. The sericin solution was concentrated from 0.1wt% solution to 0.2 wt % solution during about 2 hrs by the UF filteration membrane system.

An Approximate Analytical Solution for the Unsteady Close-Contact Melting on a Flat Surface with Constant Heat Flux (등열유속에 의한 평판위 비정상 접촉융해에 대한 근사적 해석해)

  • Yoo, Hoseon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.12
    • /
    • pp.1726-1734
    • /
    • 1998
  • This paper focuses on the unsteady close-contact melting phenomenon occurring between a phase change material kept at its melting temperature and a flat surface on which constant heat flux is imposed. Based on the same simplifications and framework of analysis as the case of constant surface temperature, an approximate analytical solution which depends only on the liquid-to-solid density ratio is successfully derived. In order to keep consistency with the known solution procedure, both the dimensionless wall heat flux and the Stefan number are properly redefined. The obtained solution proves to agree quite well with the published numerical data and to be capable of resolving the fundamental features of unsteady close-contact melting, especially in the presence of the solid-liquid density difference. The density ratio directly affects the film growth rate and the initial value of solid descending velocity, thereby controlling the duration of unsteady process. The effects of other parameters can be evaluated readily from the steady solution which is implied in the normalized result. Since the dimensionless surface temperature for the present boundary condition increases from zero to unity along the evolution path of the liquid film thickness, the unsteady process lasts longer than that for the case of isothermal heating.

A Transformer protective Relaying Algorithm Based on Increment of Flux Linkages (쇄교자속비를 이용한 변압기 보호 알고리즘)

  • Kang, Y.C.;Lee, B.E.;Jin, E.S.;Won, S.H.;Lim, U.J.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.53-55
    • /
    • 2003
  • This paper propose a transformer protective relaying algorithm based on the increment of flux linkages (RIFL) of the Primary and secondary windings. The RIFL is equal to the turn ratio for all operating conditions except an internal faults. For a single-phase transformer and three-phase Y-Y transformer, the increments of flux linkages are calculated and their ratios are compared with the turn ratio. For a three-phase Y-$\triangle$ transformer, the difference of the increments of flux linkages are calculated to use the line currents instead of the delta winding currents, which are practically unavailable. Their ratios are compared with the turn ratio. The results of various tests show that the algorithm successfully discriminates internal faults from normal operation conditions such as magnetic inrush and overexcitation. The algorithm can not only detect internal winding faults, but reduce the relay's operating time.

  • PDF

A Appropriate Flux Generating Conditions for Semiconductor Etching Simulation (반도체 식각 전산모사에 적합한 플럭스 생성 조건)

  • Jeong, Seunghan;Gwun, Oubong;Shin, Seongsik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.3
    • /
    • pp.105-115
    • /
    • 2015
  • In semiconductor etching simulation, The source modeling for generating plasma species is required. In this paper, we modeled the source of plasma etching process with probability distribution and the feature profile with simple geometry objects, then got the flux on the feature profile. The distance between the source and the cell on the modeling parameters of the source, there are a number of particles to be emitted from a source, there is a number (area of the cell) of the cell on the profile with additional parameters to give the calculation of flux. The flux error ratio on both gaussian(Incident Flux) and cosine probability distribution(Incident Neutral Flux) is much decreased as the number of ray is increased but the processing time is more increased than that. The increase of the number of cell and distance makes increase the flux error ratio and the processing time moderately. In view of the processing time through the experimental results in this paper, it is possible to analogize the calculation of appropriate fluxes.

Development of Mass Transfer Models for Ammonia Flux Estimation from Sewage Treatment Plants (하수처리장에서의 암모니아 플럭스 산정을 위한 물질전달모형 개발)

  • Sa, Jae-Hwan;Jeon, Eui-Chan;Jeong, Jae-Hak
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.5
    • /
    • pp.701-711
    • /
    • 2006
  • Sewage treatment plants located near to large cities emit extremely higher concentration of odorous materials. This study evaluated flux profiles of ammonia emitted from the water surface of sewage treatment plants using a dynamic flux chamber. Also, an ammonia overall mass transfer coefficient and a mass transfer model was developed in order to estimate fluxes of ammonia using environment parameters and the flux from the sewage treatment plants. The developed mass transfer model was evaluated through a fitness analysis. Comparison modeled flux applying empirical overall mass transfer coefficients of ammonia and measured ammonia flux show a high linearity with 0.977. The flux ratio of 1.282 demonstrated highly statistical fitness, also. Modeled flux using the mass transfer model was compared with measured flux. In result, it indicated that empirical overall mass transfer coefficients were similar to measured flux. The mass transfer model using the empirical overall mass transfer coefficient developed in this study was proved to be an easy and effective method to make accurate and precise predictions for ammonia flux discharged from sewage treatment plants.