Measurements of In-phantom Neutron Flux Distribution at the HANARO BNCT Facility

  • Published : 2004.06.01

Abstract

In-phantom neutron flux distribution is measured at the HANARO BNCT irradiation facility. The measurements are performed with Au foil and wires. The thermal neutron flux and Cd ratio obtained at the HANARO BNCT facility are $1.19{\times}10^9\;n/cm^{2}s$ and 152, respectively, at 24 MW reactor power. The measured in-phantom neutron flux has a maximum value at a depth of 3 mm in the phantom and then decreases rapidly. The maximum flux is about $25\%$ larger than that of the phantom surface, and the measured value at a depth of 22 mm in the phantom is about a half of the maximum value. In addition, the neutron beam is limited well within the aperture of the neutron collimator. The two-dimensional in-phantom neutron flux distribution is determined. Significant neutron irradiation is observed within 20 mm from the phantom surface. The measured neutron flux distribution can be utilized in irradiation planning for a patient.

Keywords

References

  1. D.N. Slatkin, 'A History of Boron Neutron Capture Therapy of Brain Tumors', Brain, 114, 1609 (1991) https://doi.org/10.1093/brain/114.4.1609
  2. 'Boron-Neutron Capture Therapy for Tumors', edited by H. Hatanaka, Nishimura Co. Ltd., (1986)
  3. H. Yanagie , T. Tomita, H. Kobayashi, Y. Fujii, Y. Nonaka, Y. Saegusa, K. Hasumi, M. Eriguchi, T. Kobayashi and K. Ono, 'Inhibition of human pancreatic cancer growth in nude mice by boron neutron capture therapy', British Journal of Cancer 75(5),660 (1997)
  4. 'Advances in Neutron Capture Therapy Volume I, Medicine and Physics', Proceedings of the Seventh International Symposium on Neutron Capture Therapy for Cancer, ed. B. Larsson, J. Crawford and R. Weinreich, Zurich, Switzerland (1996)
  5. 'Research and Development in Neutron Capture Therapy', Proceedings of the 10th International congress on Neutron Capture Therapy, ed. W. Sauerwein, R. Moss and A. Wittig, Essen, Germany (2002)
  6. C.Y. HAN, J.K. KIM, and K.S. CHUNG, 'An Epithermal Neutron Beam Design for BNCT Using $^2H(d,n)^3He$ Reaction', Journal of the Korean Nuclear Society 31(5),512 (1999)
  7. B.C. Lee, S.J. Park, M.S. Kim and B.J. Jun, 'BNCT Facility Development in HANARO', Proceedings of the International Group on Research Reactors 9th meeting(IGORR9), Sydney, Australia (2003)
  8. S.Y. Hwang, M.S. Kim, B.J. Jun, J.B. Lee, S.J. Park, B.H. Lee, B.C. Lee, J.H. Lee, K.H. Lim and M.J. Kim, 'Installation of BNCT Irradiation Facility and Measurement of Neutron and Gamma-ray Leakages', Proceedings of the Korean Nuclear Society Spring Meeting, Korea (2001) (in Korean)
  9. M.S. Kim, S.J. Park, B.C. Lee and B.J. Jun, 'Neutron Flux Measurements of Irradiation Facility with BNCT Neutron Filter of Room Temperature', Proceedings of the Korean Nuclear Society Spring Meeting, Korea (2002) (in Korean)
  10. G.Y. Lee, S.Y. Hwang and B.J. Jun, 'Development of Mixed Shielding Materials using Li-6 enriched Lithium Carbonate and HDPE for the BNCT Beam Collimator of the HANARO', Proceedings of the Korean Association for Radiation Protection Autumn Meeting, Korea (2001) (in Korean)
  11. T. Yamamoto, A. Matsumura, K. Yamamoto, H. Kumada, Y. Shibata and T. Nose, 'Inphantom two-dimensional thermal neutron distribution for intraoperative boron neutron capture therapy of brain tumours', Phys. Med. BioI. 47, 2387 (2002) https://doi.org/10.1088/0031-9155/47/14/302
  12. K. Tanaka, T. Kobayashi, Y. Sakurai, Y. Nakagawa, S. Endo and M. Hoshi, 'Dose distributions in a human head phantom for neutron capture therapy using moderated neutrons from the 2.5 MeV proton-$^7Li$ reaction or from fission of $^{235}U$', Phys. Med. BioI. 46, 2681 (2001) https://doi.org/10.1088/0031-9155/46/10/311
  13. Y. Sakurai and T. Kobayashi, 'Characteristics of the KUR Heavy Water Neutron Irradiation Facility as a neutron irradiation field with variable energy spectra', Nucl. Instr. and Meth. A453, 569 (2002) https://doi.org/10.1016/S0168-9002(00)00465-4