• Title/Summary/Keyword: flux concentration

Search Result 927, Processing Time 0.026 seconds

Enhanced Iontophoretic Delivery of Risedronate Sodium Across Hairless Mice Skin (무모생쥐 피부에 리제드로네이트 소디움의 이온토포레시스 경피전달)

  • Hwang, In-Young;Lee, Mi-Jung;Jung, Suk-Hyun;Jeong, Seo-Young;Cho, Sun-Hang;Gil, Young-Sig;Jeong, Sang-Young;Shin, Byung-Cheol
    • Journal of Pharmaceutical Investigation
    • /
    • v.40 no.2
    • /
    • pp.79-84
    • /
    • 2010
  • Osteoporosis was traditionally defined by the occurrence of nontraumatic fractures, especially of the spine, in the setting of low bone mass. Bisphosphonates are an important group of therapeutic agents for the management of osteoporosis, as they inhibit bone resorption and increase bone density, thereby potentially decreasing fracture risk. Risedronate sodium is a bisphosphonate class used by oral formulation. In this study, risedronate was transdermally delivered by iontophoresis. Effects of polarity, pH, current density, and drug concentration were studied using a side-by-side diffusion cell including the hairless mice skin. In addition we studied effect of enhancers. The flux was evaluated by HPLC/UV system. The amount of transported drug under iontophoretic delivery was approximately 186 fold higher than that under passive delivery. Flux was proportional to the increase of drug concentration and current density. The flux was observed about 0.68mg/$cm^2$ when the amout of Propyleneglycol monolaurate (PGML) used 1% as enhancer. Results indicated that iontophoresis is an effective method for transdermal administration of risedronate sodium

A Numerical Analysis for Estimations of Osmotic Pressure of Colloidal Suspension and Gradient Diffusion Coefficient of Particles from Permeate Flux Experiments (투과플럭스 실험으로부터 콜로이드 서스펜션의 삼투압과 입자의 구배확산계수 산출을 위한 수치적 해석)

  • 전명석
    • Membrane Journal
    • /
    • v.12 no.2
    • /
    • pp.90-96
    • /
    • 2002
  • A novel methodology on the calculations of osmotic pressure and gradient diffusion coefficient has been provided ill the present study, by applying a succinct numerical analysis on the experimental results. Although both the osmotic pressure and the gradient diffusion coefficient represent a fundamental characteristic in related membrane filtrations such as microfiltration and ultrafiltration, neither theoretical analysis nor experiments can readily determine them. The osmotic pressure of colloidal suspension has been successfully determined from a relationship between the data of the time-dependent permeate flux, their numerical accumulations, and their numerical derivatives. It is obvious that the osmotic pressure is gradually increased, as the particle concentration increases. The thermodynamic coefficient was calculated from the numerical differentiation of the correlation equation of osmotic pressure, and the hydrodynamic coefficient was evaluated from the previously developed relation for an ordered system. Finally, the estimated gradient diffusion coefficient, which entirely depends on the particle concentration, was compared to the previous results obtained from the statistical mechanical simulations.

Scale formation on vacuum membrane distillation for SWRO brine treatment (진공 막증류 공정의 스케일 막오염 형성에 관한 연구)

  • Hwang, Tae-Mun;Jang, Eun-Kyung;Nam, Sook-Hyun;Koo, Jae-Wuk;Kim, Eun-Ju
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.4
    • /
    • pp.311-319
    • /
    • 2017
  • Scale formation is inevitable problem when seawater is treated by vacuum membrane distillation. The reason is the high concentration of calcium ion($Ca^{2+}$), sulfate ion(${SO_4}^{2-}$) and bicarbonate ion(${HCO_3}^-$). These ions form calcium sulfate($CaSO_4$) and calcium carbonate($CaCO_3$) on the membrane. The scale formed on membrane has to be removed, because the flux can be severely reduced and membrane wetting can be incurred. This study was carried out to investigate scale formation and effectiveness of acid cleaning in vacuum membrane distillation for SWRO brine treatment. It was found that permeate flux gradually declined until volume concentration factor(VCF) reached around 1.55 and membrane wetting started over VCF over 1.6 in the formation of precipitates containing $CaSO_4$ during VMD operation. In contrast, when calcium carbonate formed on membrane, permeate flux was gradually reduced until VCF 3.0. The precipitates containing both $CaSO_4$ and $CaCO_3$ were formed on the membrane surface and in the membrane pore.

A Study on the high-flux MBR system using PTFE flat membrane and coagulant(Alum) for removal of phosphorus (PTFE재질의 평판형 분리막과 인제거를 위해 Alum주입을 적용한 고플럭스 MBR시스템에 관한 연구)

  • Lee, Eui-Jong;Kim, Kwan-Yeop;Kwon, Jin-Sub;Kim, Young-Hoon;Lee, Yong-Soo;Lee, Chang-Ha;Jeon, Min-Jung;Kim, Hyung-Soo;Kim, Jung-Rae;Jung, Jin-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.1
    • /
    • pp.95-106
    • /
    • 2011
  • Even though MBR processes have many advantages such as high quality effluents, a small footprint and convenience for operation compared to conventional activated sludge processes, there are some shortcomings in terms of the cost and potential fouling incident that keeps MBR (Membrane bioreactor) processes from being widely applied. To reduce these problems, PTFE (Polytetrafluoroethylene) flat sheet membranes that have excellent permeability and durability were tested instead of PVDF (Polyvinylidene fluoride) membrane which is being used widely in water treatment. Low concentration of sodium hydroxide (NaOH) was also added into the membrane modules in order to prevent the membrane fouling as well as to provide the alkalinity. With conditions mentioned above, a pilot-scale MBR system based on the MLE (Modified Ludzack Ettinger) process was operated at flux of 40 $L/m^{2}/hr$ and over 15,000 mg/L MLSS concentration for about 8 months. And coagulant(alum) was added into the membrane tank to remove phosphorus. Although the more coagulant is added the more effectively phosphorus is removed, that can lead to fouling for a long operation(Ronseca et al.,2009). By the way there is a research that fouling grow up after stopping injection of coagulant(Holbrook, 2004). Stable operation of MBR systems was achieved without major chemical cleaning and the effluent quality was found to be good enough to comply with the treated waste water quality regulations of the Korea.

The Estimating an Effect of Rapid Flux Increase to a Membrane in the Intermittent Aeration MBR Process Using Alum Treatment (응집제를 활용한 간헐포기 MBR공정에서 순간플럭스 증가가 분리막에 미치는 영향 평가)

  • Choi Song-Hyu;Cho Nam-un;Han Myong Su
    • Membrane Journal
    • /
    • v.15 no.1
    • /
    • pp.70-83
    • /
    • 2005
  • By supplying air intermittently in various mode, the effects of oxic/anoxic time ratio and air scrubbing in aeration condition on the membrane flux and permeability were investigated. When suction pump stops, vacuum pressure remains inside the suction pump. Therefore, the effect of remaining vacuum pressure in the suction pump on fouling of membrane was investigated. The effect of EPS (Extra cellular Polymeric Substance) which is generated due to the long SRT and high concentration of MLSS and the dose of coagulant on the membrane were also investigated. The suitable oxic/anoxic time ratio for the best removal efficiency of organic matter and nitrogenous matter was 40 minutes (Oxic) : 20 minutes (Anoxic). At this time ratio, alum was dosed into the aeration tank. The result of dosing alum was that the concentration of alum solution might affect nitrification and denitrification. To remove 1 mg/L of phosphorus in MBR process, it needs 0.75 mg/L of alum solution.

Flow of MHD Powell-Eyring nanofluid: Heat absorption and Cattaneo-Christov heat flux model

  • Sharif, Humaira;Khadimallah, Mohamed A.;Naeem, Muhammad Nawaz;Hussain, Muzamal;Hussain, Sajjad;Tounsi, Abdelouahed
    • Advances in nano research
    • /
    • v.10 no.3
    • /
    • pp.221-234
    • /
    • 2021
  • During the previous few years, phenomenon of bioconvection along with the use of nanoparticles showed large number of applications in technological and industrial field. This paper analyzed the bioconvection phenomenon in magnetohydrodynamic boundary layer flow of a Powell-Eyring nanoliquid past a stretchable cylinder with Cattaneo-Christov heat flux. In addition, the impacts of chemical reaction and heat generation/absorption parameter are considered. By the use of appropriate transformation, the governing PDEs (nonlinear) have been transformed and formulated into nonlinear ODEs. The resulting nonlinear ODEs subjected to relevant boundary conditions are solved analytically through homotopy analysis method which is programmed in Mathematica software. Graphical and numerical results versus physical quantities like velocity, temperature, concentration and motile microorganism are investigated under the impact of physical parameters. It is noted that velocity profile enhances as the curvature parameter A and Eyring-Powell fluid parameter M increases but a decline manner for large values of buoyancy ratio parameter Nr and bio-convection Rayleigh number Rb. In the presence of Prandtl number Pr, Eyring-Powell fluid parameter M and heat absorption parameter ��, temperature profile decreases. Nano particle concentration profile increases for increasing values of magnetic parameter Ha and thermophoresis parameter Nt. The motile density profile has revealed a decrement pattern for higher values of bio-convection Lewis number Lb and bio-convection peclet number Pe. This study may find uses in bio-nano coolant systems, advance nanomechanical bio-convection energy conversion equipment's, etc.

Performance Evaluation of a Closed-Loop Pressure Retarded Membrane Distillation for Brackish Water Desalination and Power Generation (기수담수화와 전력 생산을 위한 폐루프형 압력 지연식 막 증류 공정의 성능 평가)

  • Cho, Gyu Sang;Lee, Jun-Seo;Park, Kiho
    • Korean Chemical Engineering Research
    • /
    • v.60 no.4
    • /
    • pp.525-534
    • /
    • 2022
  • In this study, we investigated the applicability and optimal operating strategy of a closed-loop pressure retarded membrane distillation (PRMD) for brackish water desalination. For effective operation with net power generation, high temperature of heat source over 90 ℃ and feed flow rate at 0.6 kg/s are recommended. At 3 g/L of feed concentration, the average permeate flux and net energy density showed 8.04 kg/m2/hr and 2.56 W/m2, respectively. The average permeate flux and net energy density were almost constant in the range of feed concentration from 1 to 3 g/L. Compared to the case with seawater feed, the PRMD with brackish water feed showed higher average permeate flux and net energy density. Thus, PRMD application using brackish water feed can be more effective than that using seawater feed in terms of power generation.

Measurements of Void Concentration Parameters in the Drift-Flux Model (상대유량 모델내의 기포분포계수 측정에 관한 연구)

  • Yun, B.J.;Park, G.C.;Chung, C.H.
    • Nuclear Engineering and Technology
    • /
    • v.25 no.1
    • /
    • pp.91-101
    • /
    • 1993
  • To predict accurately the thermal hydraulic behavior of light water reactors during normal or abnormal operation, the accurate estimation of the void distribution is required. Up to date, many techniques for predicting void fraction of two-phase flow systems have been suggested. Among these techniques, the drift-flux model is widely used because of its exact calculation ability and simplicity. However, to get more accurate prediction of void fraction using drift-flux model, slip and flow regime effects must be considered more properly In the drift-flux method, these two effects are accounted for by two drift-flux parameters ; $C_{o}$ and (equation omitted). At earlier stage, $C_{o}$ is measured in a circular tube. In this study, $C_{o}$ is experimentally determined by measuring local void fraction and vapor velocity distribution in a rectangular subchannel having 4 heating rods which simulates nuclear subchannels. The measurements are peformed with two-electrical conductivity probes which are known to be adequate for measuring local parameters. The experiments are performed at low flow rate and the system pressure less than 3 atmo spheric pressure. In this experiment, (equation omitted), is not measured, but quoted from well-known empirical correlation to formulate $C_{o}$. Finally, $C_{o}$ is expressed as a function of channel averaged void fraction. fraction.

  • PDF

A Study on Reverse Osmosis Composite Membrane with Polysulfone Supporting Membrane (역삼투 복합막 제조(I) 폴리설폰지지체 계면중합 역삼투용 복합막 제조)

  • 김명만;박종원;민병렬
    • Membrane Journal
    • /
    • v.4 no.1
    • /
    • pp.38-45
    • /
    • 1994
  • The experiment was conducted to evaluate the effects of variables in preparing TFC membrane by interfacial polymerization. Obtained results are as follow: As the concentration of MPD increses, the rejection rate incresed, the total volume flux was decresed. As the dipping time in MPD solution increases, the rejection rate increased, the total volume flux was increased until reach optimum point. As the dipping time in TMC solution increses, the total volume flux increased, the rejection rate was increased until reach optimum point. As the curing temperature increases, the total volume flux increased was an optimum point in the rejection rate. Since the quantity of generating hydrochloric acid was small, the required quantity of NaOH for neutriliztion was small. The post-treatment with ethanol, isopropanol and water in the temprerature ranging of $5~7^{\circ}C$ brought an increment of the rejection and the total volume flux, For water temperature ranging of $5~7^{\circ}C$was the optimum temperature in the post treatment.

  • PDF

Using Coagulant and Activated Carbon as Pretreatment for Membrane Fouling Control in MBR (Membrane Bioreactor) (MBR반응기의 막오염방지를 위한 활성탄과 응집제를 이용한 전처리에 관한 연구)

  • Kim, Dong-Ha
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.1
    • /
    • pp.122-127
    • /
    • 2006
  • The aim of this study was to investigate the characteristics of membrane fouling caused by soluble organic materials in a membrane bioreactor process. For the removal of filterable organic materials (FOC) smaller than $1{\mu}m$, coagulants and activated carbon were added. A membrane bioreactor using a submerged $17{\mu}m$ metal sieve was operated in laboratory scale to examine the possibility of membrane fouling control. As the dosage of GAC and coagulant increased, the residual FOC concentration decreased and the permeate flow rate increased markedly. The permeate flux increased with an increased PACl addition at the range from 0 to 50 mg/l. At coagulant dosage of 27mg/l, the removal of FOC was about 46% and the flux increased to 3.5 times compared to the case without PACl addition. The permeate flux increased gradually with an increase in GAC dosage. At GAC dosage of 50mg/L, the permeate flux was about 2 times higher compared that for raw water. The particle in the range of $0.1{\sim}1.0{\mu}m$ were removed effectively by the addition of GAC and coagulant. Higher osage of GAC and coagulant, led to higher removal of FOC. A different set of experiments was also performed to investigate the effect of pretreatment on the permeation ability of MBR system using the metal sieve membrane. After 40 hours of operation, the permeate flux was about 1,000 ($L/m^2-hr$), which is 20 times higher compared to the results in literature. It is likely that combined pretreatment using coagulant and activated carbon was the most effective to resolve membrane fouling problems. Moreover, the continuous operations could be successful by applying this pretreatment method.