• Title/Summary/Keyword: flushing time

Search Result 139, Processing Time 0.028 seconds

Temporary Metadata Journaling Scheme to Improve Performance and Stability of a FAT Compatible File System (FAT 파일 시스템의 호환성을 유지하며 성능과 안정성을 향상시키는 메타데이터 저널링 기법의 설계)

  • Hyun, Choul-Seung;Choi, Jong-Moo;Lee, Dong-Hee;Noh, Sam-H.
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.36 no.3
    • /
    • pp.191-198
    • /
    • 2009
  • The FAT (File Allocation Table) compatible file system has been widely used in mobile devices and memory cards because of its data exchangeability among numerous platforms recognizing the FAT file system. By the way. modern embedded systems have tough demands for instant power failure recovery and superior performance for multimedia applications. The key issue is how to achieve the goals of superior write performance and instant booting capability while controlling compatibility issues. To achieve the goals while controlling compatibility issues. we devised a temporary meta-data journaling scheme for a FAT compatible file system. Benchmark results of the scheme implemented in a FAT compatible file system shows that it really improves write performance of the FAT file system by converting small random write for meta-data update to a large sequential write in journaling area. Also, it provides natural way to implement the instant booting capability. Nevertheless, the file system compatibility is temporarily compromised by the scheme because it stores updated meta-data in the temporary journaling area rather than to their original locations. However, the compatibility can be fully recovered at any time by journal-flushing that copies meta-data in journaling area to their original locations. Generally, the journal-flushing is done before un-mounting a memory card so that it can be used in other mobile devices which recognized FAT file system but not the temporary meta-data journaling scheme.

Advanced Water Treatment of High Turbidity Source by Hybrid Process of Multi-channels Ceramic Microfiltration and Activated Carbon Adsorption (다채널 세라믹 정밀여과 및 활성탄 흡착 혼성공정에 의한 고탁도 원수의 고도정수처리)

  • Park, Jin-Yong;Lee, Hyuk-Chan
    • Membrane Journal
    • /
    • v.18 no.4
    • /
    • pp.325-335
    • /
    • 2008
  • In this study, we used multi-channels ceramic membrane having larger permeate volume per unit time rather than tubular membrane. The hybrid process for advanced drinking water treatment was composed of granular activated carbons (GAC) packing between module inside and outside of multi-channels microfiltration membrane. Instead of natural organic matters (NOM) and fine inorganic particles in natural water source, modified solution was prepared with humic acid and kaolin. Kaolin concentration was fixed at 30mg/L and humic acid was changed as $2{\sim}10\;mg/L$ to inspect effect of organic matters. As a result, both resistance of membrane fouling ($R_f$) and permeate flux (J) were highly influenced by concentration of humic acid. Also, in result of water-back-flushing period (FT) effect, the shorter FT was the more effective to reduce membrane fouling and to enhance permeate flux because of frequent water-back-flushing. However, the optimal FT condition was 8 min when operating costs were considered. Then, the hybrid process using multi-channels ceramic membrane and GAC was applied to lake water treatment. As a result, average treatment efficiencies in our experiment using the hybrid process were 98.02% for turbidity, 75.64% for $UV_{254}$ absorbance, 7.18% for TDS and 84.73% for $COD_{Mn}$.

Laboratory Tests for Trichloroethylene (TCE) and Toluene Remediation in Soil Using Soil Vapor Extraction (토양증기추출(Soil Vapor Extraction)을 이용한 토양 내 Trichloroethylene (TCE)과 Toluene정화 실험)

  • 이민희;강현민
    • Economic and Environmental Geology
    • /
    • v.35 no.3
    • /
    • pp.221-227
    • /
    • 2002
  • Column experiments were performed to evaluate the removal efficiency of soil vapor extraction (SVE) iota TCE (trichloroethylene) and toluene in soil. Homogeneous Ottawa sands and real soils collected from contaminated area were used to investigate the effect of soil properties and SVE operation conditions on the removal efficiency. In column teats with two different sizes of Ottawa sand, the maximum effluent TCE concentration in a coarse sand column was 442 mg/L and 337 mg/L in a fine sand column. However, after 20 liter gas flushing, the effluent concentrations were very similar and more than 90% of initial TCE mass were removed from the column. For two real contaminated soil columns, the maximum effluent concentration decreased 50% compared with that in the homogeneous Ottawa coarse sand column, but 99% of initial TCE mass were extracted from the column within 40 liter air flushing, suggesting that SVE is very available to remove volatile NAPLs in the contaminated soil. To investigate the effect of contaminant existing time on the removal efficiency, an Ottawa sand column was left stable for one week after TCE was injected and the gas extraction was applied into the column. Its effluent concentration trend was very similar to those for other Ottawa sand columns except that the residual TCE after the air flushing showed relatively high. Column tests with different water contents were performed and results showed high removal efficiency even in a high water content sand column. Toluene as one of BTEX compounds was used in an Ottawa sand column and a real soil column. Removal trends were similar to those in TCE contaminated columns and more than 98% of initial toluene mass were removed with SVE in both column.

A Study on Removal of Organic Matter and Chromaticity from Urine Using Chemical Oxidization Process (화학적 산화공정을 이용하여 소변의 색도 및 유기물 처리를 통한 재이용 기술 연구)

  • Shin, Sung-Hoon;Jung, Jong-Tai;Cho, Yong-Chul
    • Journal of Korean Society of Water Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.109-115
    • /
    • 2018
  • This study was conducted to solve the water shortage problem by reclaiming urine from homes or public places and using it as cleaning water for toilets. The process used in this experiment is a chemical oxidation process combining ozone, hydrogen peroxide, and UV. We set the key substance that is to be removed as chromaticity and conducted the experiment to remove it. If the quantity or concentration of injected ozone, UV, and hydrogen peroxide is insufficient, then the chromaticity will initially increase due to low oxidizing power, and will later decrease. In addition, the efficiency of removing chromaticity appeared to be higher, depending on the quantity of ozone injected, for medium concentrated urine than highly concentrated urine. However, the absolute quantity of removed chromaticity was about 68% higher for highly concentrated urine, when 16 g/hr of ozone was injected. The higher the pH level, the reaction time and efficiency of removing chromaticity were higher, and in normal conditions, in reference to a pH of 8.55, there was a 6% difference in efficiency between a pH level of 5.05 and a pH level of 10.12. Finally, when processing urine through an ozone-only process, COD decreased steadily over time, but DOC did not decrease. This is because ozone reacts selectively with organic matter.

The Edge Computing System for the Detection of Water Usage Activities with Sound Classification (음향 기반 물 사용 활동 감지용 엣지 컴퓨팅 시스템)

  • Seung-Ho Hyun;Youngjoon Chee
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.2
    • /
    • pp.147-156
    • /
    • 2023
  • Efforts to employ smart home sensors to monitor the indoor activities of elderly single residents have been made to assess the feasibility of a safe and healthy lifestyle. However, the bathroom remains an area of blind spot. In this study, we have developed and evaluated a new edge computer device that can automatically detect water usage activities in the bathroom and record the activity log on a cloud server. Three kinds of sound as flushing, showering, and washing using wash basin generated during water usage were recorded and cut into 1-second scenes. These sound clips were then converted into a 2-dimensional image using MEL-spectrogram. Sound data augmentation techniques were adopted to obtain better learning effect from smaller number of data sets. These techniques, some of which are applied in time domain and others in frequency domain, increased the number of training data set by 30 times. A deep learning model, called CRNN, combining Convolutional Neural Network and Recurrent Neural Network was employed. The edge device was implemented using Raspberry Pi 4 and was equipped with a condenser microphone and amplifier to run the pre-trained model in real-time. The detected activities were recorded as text-based activity logs on a Firebase server. Performance was evaluated in two bathrooms for the three water usage activities, resulting in an accuracy of 96.1% and 88.2%, and F1 Score of 96.1% and 87.8%, respectively. Most of the classification errors were observed in the water sound from washing. In conclusion, this system demonstrates the potential for use in recording the activities as a lifelog of elderly single residents to a cloud server over the long-term.

Effects of laser-assisted hatching and exposure time to vitrification solution on mouse embryo development

  • Kim, Hye Jin;Park, Sung Baek;Yang, Jung Bo;Choi, Young Bae;Lee, Ki Hwan
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.44 no.4
    • /
    • pp.193-200
    • /
    • 2017
  • Objective: This study was conducted to investigate the efficacy of laser-assisted hatching (LAH) and various vitrification times for embryonic development and blastocyst cell numbers. Methods: First, 2-cell and 8-cell embryos were collected by flushing out the oviducts. In the control groups, they were vitrified for 8 or 10 minutes without LAH. The LAH groups underwent quarter laser zona thinning-assisted hatching before vitrification (4, 6, and 8 minutes or 4, 7, and 10 minutes, respectively). After incubation, double-immunofluorescence staining was performed. Results: The hatched blastocyst rate 72 hours after the 2-cell embryos were thawed was significantly higher in the 2LAH-ES8 group (33.3%) than in the other groups (p< 0.05). In the control-8 group ($22.1{\pm}4.6$), the cell number of the inner cell mass was higher than in the LAH groups (p< 0.05). The number of trophectoderm cells was higher in the 2LAH-ES6 group ($92.8{\pm}8.9$) than in the others (p< 0.05). The hatched blastocyst rate 48 hours after the 8-cell embryos were thawed was higher in the 8LAH-ES4 group (45.5%) than in the other groups, but not significantly. The inner cell mass cell number was highest in the 8LAH-ES7 group ($19.5{\pm}5.1$, p< 0.05). The number of trophectoderm cells was higher in the 8LAH-ES10 group ($73.2{\pm}12.1$) than in the other groups, but without statistical significance. Conclusion: When LAH was performed, 2-cell embryos with large blastomeres had a lower hatched blastocyst rate when the exposure to vitrification solution was shorter. Conversely, 8-cell embryos with small blastomere had a higher hatched blastocyst rate when the exposure to vitrification solution was shorter.

Experimental Study for Flushing of Sediment Bypass Pipe underneath Rubber Weir (고무보 저층수 배출관의 유사 배제 성능 실험 연구)

  • Jeong, Seok Il;Lee, Seung Oh
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.133-140
    • /
    • 2016
  • Most small weir installed in Korea is concrete solidated weir. Fixed weir causes stagnant flow, which leads to deposit sediment just upstream of weir. As time goes on, it would induce reduction of water storage capacity and invoke the serious water quality issues. Therefore, there has been a growing interest in movable weir. Especially, the flexible rubber weir is easy to install and possible to operate in extreme environments. However, even though this type can be flatable, it is also not free from sediment deposition problem. Thus, to enhance the ability of releasing deposition the bypass pipe was constructed underneath it. In this study the performance of its ability was examined with hydraulic model test. This bypass pipe was designed with 3 different dimensions to connect between each bottom of upstream and downstream of a weir, such as Type A, B, and C. The efficiency of drainage of deposition upstream was studied under two water of upstream and sediment heights. In addition, the ability of sediment emission through the bypass pipe after the pipe was blocked by debris like soil, vegetation et al. was examined by video monitoring. From this study, it was suggested a dimensionless equation which show the relationship of variable parameters and amount of emission sediment through bypass pipe. And it was found that the most significant factors on efficiency of releasing were elbow angle and discharge, and the ability of emission when the pipe was blocked was most highly influenced in tilting length.

Tidal Exchange of Sea Water in Koje Bay (거제만의 해수교환)

  • KIM Jong-Hwa;CHANG Sun-Duck
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.18 no.2
    • /
    • pp.101-108
    • /
    • 1985
  • The sea water exchange of Koje Bay in the southeastern part of the Korean Peninsula was estimated on the basis of current measurements and oceanographic observation. The exchange ratio was estimated by salinity differences and tidal prism method. The range of exchange ratio at the central part at the entrance of the bay is estimated to be around $26\%$ at spring tide and 5 to $15\%$ at neap tide. The magnitude of exchange ratio, however, can be changed due to water exchange, hydrometeorological and geomorphological conditions. The flushing time deduced by tidal prism was about 48 hours at spring tide and 81 hours at neap tide. Tidal induced eddy motion may play an important role on the seawater exchange in the bay.

  • PDF

Decrease of PEMFC Performance by SO2 in Air (공기 중 SO2에 의한 고분자전해질 연료전지의 성능 감소)

  • Lee, Ho;Song, Jinhoon;Kim, Kijoong;Kim, Saehoon;Ahn, Byungki;Lim, Taewon;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.48 no.3
    • /
    • pp.311-315
    • /
    • 2010
  • The effects of $SO_2$ on the performance of proton exchange membrane(PEMFC) were investigated by introduction air containing $SO_2$ into cathode inlet of PEMFC. And the recovery of the cell performance by applying clean air, cycle voltammetry(CV) and high voltage holding following exposure contaminated air was studied. The $SO_2$ concentration range used in the experiments was from 20 ppb to 1.3 ppm. The performance degradation and recovery were measured by constant-current discharging, I-V polarization and electrochemical impedance spectroscopy(EIS). The cell voltage gradually decayed with time and decreased by 17 mV after 200 hours of 20 ppb $SO_2$ injection. The cell performance can be recovered partially by clean air flushing, CV and high voltage holding due to desorption of S from Pt catalyst.

Wall Contamination of Teflon Bags Used as a Photochemical Reaction Chamber of Ambient Air (실제 대기의 광화학 반응 챔버로 사용되는 테플론 백의 오염도 평가)

  • Lee, Seung-Bok;Bae, Gwi-Nam;Lee, Young-Mee;Moon, Kil-Choo
    • Particle and aerosol research
    • /
    • v.9 no.3
    • /
    • pp.149-161
    • /
    • 2013
  • Experiments on photochemical reactions of purified air alone in an indoor smog chamber were carried out after flushing Teflon bags with purified air for many hours in order to check the level of contamination on the chamber wall. Ozone concentrations were linearly increased from <4 ppb up to about 8 ppb with irradiation time for four hours. Outgassing of NOx from the chamber wall was found to be less than 1 ppb. New ultrafine particles were formed and grown up to about 70 nm during the photochemical reactions, and then total number and mass concentrations of particles were increased from <10 particles/$cm^3$ up to about 4,000 particles/$cm^3$ and $1.3{\mu}g/m^3$, respectively. The wall conditions of these Teflon bags flushed with purified air might not severly affect the chamber experimental results for photochemical reactions of polluted urban ambient air. The difference of gaseous species between two chambers was 2.4 ppb of ozone at most, indicating that the wall cleaning performance of two chambers was nearly similar.