• Title/Summary/Keyword: fluoroscopy time

Search Result 99, Processing Time 0.027 seconds

Reference levels for patient Radiation Dose in interventional radiological procedures (중재적 방사선 시술 시 환자선량에 대한 참고 준위 비교)

  • Park, Hyeok;Kim, Yong-Wan;Jeon, Ju-Seob
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.1
    • /
    • pp.11-17
    • /
    • 2012
  • The purpose of this study is to measure and evaluate radiation dose on patients in interventional radiological(IVR) procedures classified by each procedure, and aid as data for safety management. Fluroscopy time(F-time), dose area product(DAP) and number of acquired images from each kind of procedure was checked. Non-vascular procedures showed low value, and vascular procedure showed high value in all procedures except in IVC filter. F-time was longest in EVAR, which showed also the highest DAP value of all procedures. DAP-rate showed high value in TACE. By this result, we attempt to establish standard guideline of radiation dose on patients in IVR procedure.

Change of Diaphragmatic Level and Movement Following Division of Phrenic Nerve (횡격막 신경 차단 후 횡격막 위치 및 운동의 변화)

  • 최종범;김상수;양현웅;이삼윤;최순호
    • Journal of Chest Surgery
    • /
    • v.35 no.10
    • /
    • pp.730-735
    • /
    • 2002
  • Diaphragm is innervated by phrenic nerve and lower intercostal nerves. For patients with avulsion injury of brachial plexus, an in situ graft of phrenic nerve is frequently used to neurotize a branch of the brachial plexus. We studied short-term and mid-term changes of diaphragmatic level and movement in patients with dissection of phrenic nerve for neurotization. Material and Method : Thirteen patients with division of either-side phrenic nerve for neurotization of musculocutaneous nerve were included in this study. With endoscopic surgical procedure, the intrathoracic phrenic nerve was entirely dissected and divided just above the diaphragm. The dissected phrenic nerve was taken out through thoracic inlet and neck wound and then anastomosed to the musculocutaneous nerve through a subcutaneous tunnel. With chest films and fluoroscopy, levels and movements of diaphragm were measured before and after operation. Result : There was no specific technical difficulty or even minor postoperative complications following endoscopic division of phrenic nerve. After division of phrenic nerve, diaphragm was soon elevated about 1.7 intercostal spaces compared with the preoperative level, but it did not show paradoxical motion in fluoroscopy. More than 1.5 months later, diaphragm returned downward close to the preoperative level (average level difference was 0.9 intercostal spaces; p=NS). Movement of diaphragm was not significantly decreased compared with the preoperative one. Conclusion : After division of phrenic nerve, the affected diaphragm did not show a significant decrease in movement, and the elevated diaphragm returned downward with time. However, the decreased lung volumes in the last spirometry suggest the decreased inspiratory force following partial paralysis of diaphragm.

Computed Tomographic Simulation of Craniospinal Irradiation (전산화 단층 촬영 장치를 이용한 뇌척수 조사의 치료 계획)

  • Lee CI;Kim HN;Oh TY;Hwang DS;Park NS;Kye CS;Kim YS
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.11 no.1
    • /
    • pp.53-59
    • /
    • 1999
  • The aim of this study is to improve the accuracy of field placement and junction between adjacent fields and block shielding through the use of a computed tomography(CT) simulator and virtual simulation. The information was acquired by assessment of Alderson Rando phantom image using CT simulator (I.Q. Xtra - Picker), determination of each field by virtual fluoroscopy of voxel IQ workstation AcQsim and colored critical structures that were obtained by contouring in virtual simulation. And also using a coronal, sagittal and axial view can determine the field and adjacent field gap correctly without calculation during the procedure. With the treatment planning by using the Helax TMS 4.0, the dose in the junction among the adjacent fields and the spinal cord and cribriform plate of the critical structure was evaluated by the dose volume histogram. The pilot image of coronal and sagittal view took about 2minutes and 26minutes to get 100 images. Image translation to the virtual simulation workstation took about 6minutes. Contouring a critical structure such as cribriform plate, spinal cord using a virtual fluoroscopy were eligible to determine a correct field and shielding. The process took about 20 minutes. As the result of the Helax planning, the dose distribution in adjacent field junction was ideal, and the dose level shows almost 100 percentage in the dose volume histogram of the spinal cord and cribriform plate CT simulation can get a correct therapy area due to enhancement of critical structures such as spinal cord and cribriform plate. In addition, using a Spiral CT scanner can be saved a lot of time to plan a simulation therefore this function can reduce difficulties to keep the patient position without any movements to the patient, physician and radiotherapy technician.

  • PDF

Distribution of the Scatter Ray in Fluoroscopy X-ray Room (투시 검사실 내 공간산란선 분포 측정)

  • Cho, Pyong-Kon
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.10
    • /
    • pp.349-354
    • /
    • 2011
  • The results of the scattery distribution in the fluoroscopy X-ray room were as follows. When the measurement was done at the same height with the table, measured value was 0.78 mGy/min ~ 0.04 mGy/min (95%) within 50 cm and 250 cm. At 50 cm below the table, it was 0.17 mGy/min ~ 0.02mGy/min (86%) and at 50 cm above the table was 1.37 mGy/min ~ 0.05 mGy/min (96%), displaying a decrease. At the same time, the amount of rays were reduced in 50 ~ 60% at the same height with the table than the location 50 cm above the table, 90~95% of reduction rate was observed at 50 cm below the table. For the collimator, comparing to the case when it was completely open, the amount of ray was reduced from 0.78 mGy/min to 0.16 mGy/min at 50cm away and 0.04 mGy/min to 0.01 mGy/min at 250cm away thus approximately 80% on average was reduced when the collimator was reduced to 25%. Comparing with the case when there was a object on the table, the amount of scatter ray was reduced by 96.7% at every location when there is not a object on the table.

Removal of Broken Instruments in Soft Tissue at Mandibular Area Using a Dental Mini C-arm: Case Reports (치과용 소형 C자형 투시장치를 이용한 하악 연조직에 위치한 부러진 기구의 제거: 증례보고)

  • Park, Sung-Soo;Yang, Hoon-Joo;Hwang, Soon-Jung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.6
    • /
    • pp.567-572
    • /
    • 2010
  • Intraoperative breakage of instruments can be occurred unexpectedly. To prevent damage of neighboring important anatomic structures and consequent complications, broken instruments should be removed as soon as possible. There have been several methods to remove broken instruments. One of them is the Carm fluoroscopy which is commonly used for locating metal foreign bodies. However, its application for removal of broken instruments in the oral and maxillofacial area is not common. In our experiences with the removal of two broken instruments in mandibular area, the newly developed dental mini C-arm was used to find broken instrument in soft tissue, because it gives real-time in situ information for the intraoperative location. We report two cases with broken instruments, a broken dental needle in the pterygomandibular space and a broken straight bur in the mandibular angle area. They were identified and could be removed safely using a dental mini C-arm.

A brief report on a technical description of ultrasound-guided lumbar sympathetic block

  • Moon, Jee Youn;Choi, Jae Kyu;Shin, Ji Yeon;Chon, Sung Won;Dev, Sushmitha
    • The Korean Journal of Pain
    • /
    • v.30 no.1
    • /
    • pp.66-70
    • /
    • 2017
  • The lumbar sympathetic ganglion block (LSGB) is widely used for diagnosing and treating sympathetically maintained pain disorders. The LSGB has been conventionally carried out under fluoroscopy or computed tomography guidance. However, as ultrasound technology improved, ultrasound-guided interventions have been expanding their territory to deeper structures. Ultrasound guidance provides many benefits including protecting vascular injection, shortening procedure time in some cases, and reducing the emission of radiation. In this report, we describe a successful case of a US-guided LSGB without major complications. We expect that US-guided LSGBs can be implemented and furnished in the daily outpatient clinical setting by highly trained pain physicians.

A Study on Pathological Pattern Detection using Neural Network on X-Ray Chest Image (신경회로망을 이용한 X-선 흉부 영상의 병변 검출에 관한 연구)

  • 이주원;이한욱;이종회;조원래;장두봉;이건기
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.2
    • /
    • pp.371-378
    • /
    • 2000
  • In this study, we proposed pathological pattern detection system for X-ray chest image using artificial neural network. In a physical examination, radiologists have checked on the chest image projected the view box by a magnifying glass and found out what the disease is. Here, the detection of X-ray fluoroscopy is tedious and time-consuming for human doing. Lowering of efficiency for chest diagnosis is caused by lots mistakes of radiologist because of detecting the micro pathology from the film of small size. So, we proposed the method for disease detection using artificial neural network and digital image processing on a X-ray chest image. This method composes the function of image sampling, median filter, image equalizer used neural network and pattern recognition used neural network. We confirm this method has improved the problem of a conventional method.

  • PDF

Diaphragmatic Hernia of the Right Hepatic Lobe Mistaken for Diaphragmatic Paralysis in Adult (성인에서 횡격막마비로 오인한 우엽간 횡격막탈장 1예)

  • Park, Jung-Hyun;Hwang, Ki-Eun;Kim, So-Young;Kim, Hak-Ryul;Yang, Sei-Hoon;Kim, Hwi-Jung;Jeong, Eun-Taik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.68 no.5
    • /
    • pp.298-300
    • /
    • 2010
  • Diaphragmatic paralysis can be demonstrated through diaphragmatic elevation on chest X-ray after thoracic lung surgery or the placement of chest tubing. Additional causes of diaphragmatic paralysis are iatrogenic, mass, atelectasis, etc. For the diagnosis of diaphragmatic paralysis, it required some studies (fluoroscopy, computed tomography [CT], magnetic resonance imaging). Diaphragmatic hernia of the liver is a rare clinical entity, usually found after trauma in adults. Congenital diaphragmatic hernia in neonates requires surgery. Non-traumatic diaphragmatic hernia of the liver in an adult is a rare right-sided diaphragmatic hernia. On developing any symptoms, surgery must be performed. When diaphragmatic hernia is incidentally found in adults without trauma, it is placed under observation for a time period. We diagnosed the diaphragmatic herniation of a right hepatic lobe by 16-slice CT scan without surgery.

Reference Levels for Radiation Dose in Angiography and Interventional Radiology : In the Cerebrum (혈관 조영 검사 및 중재적 방사선 시술시 방사선량에 대한 참고 기준치 : 대뇌 중심으로)

  • Han, Jae-Bok
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.3
    • /
    • pp.302-308
    • /
    • 2011
  • The aim of this study is to compare reference levels for radiation dose in angiography and interventional radiology. Proposed reference levels for various procedures and classification of diseases are provided by fluoroscopy time and kerma area product(KAP) rate normalizing the body habitus focusing the cerebrum. Subarachnoid hemorrhage(SAH) represents the highest KAP-rates and aneurysm represents the lowest KAP-rates. According to these types of procedures, internal carotid artery(ICA), common carotid artery(CCA), and vertebral artery(VA) show the highest KAP-rates and guglielmi detachable coil shows the lowest KAP-rates. Therefore, the present study can suggested reference levels for patient radiation dose and is expected to be further useful in the field of radiation dose education and management of angiography and interventional radiology.

Paraplegia Following Celiac Plexus Block -A case report- (복강신경총 차단후 하지마비 -증례 보고-)

  • Na, Ae-Ja;Moon, Dong-Eon;Suh, Jae-Hyun
    • The Korean Journal of Pain
    • /
    • v.6 no.1
    • /
    • pp.129-132
    • /
    • 1993
  • Paraplegia complicating a block of the celiac plexus with alcohol for recurrent stomach cancer is described. A 33 year old male patient was admitted to control for severe epigastric pain. With the patient in prone position, the needle was advanced further than 2 cm on the anterior margin of $L_1$ vertebral body under fluoroscopy. 3 ml of 1% lidocaine and 5 ml of conray were injected through each needle, and the diffusion of the contrast medium was checked, This was followed by 7 ml of pure alcohol and 8 ml of 50% alcohol for each needle. At that time, the patient was very satisfied with loss of abdominal pain. About 30 minutes after injection of alcohol, suddenly patient complained of severe burning pain on back and both extremities. Thereafter, loss of sensation and paralysis in both extremities were developed slowly. The senstivity to cold recovered 3 days after block. By the 33rd day after the block, sensation had recovered in both extremities, the bladder and rectum. Movement of the right ankle joint and left great toe was also possible.

  • PDF