• 제목/요약/키워드: fluoroscopy time

검색결과 99건 처리시간 0.029초

EDLC를 이용한 X선 투시촬영장치용 하이브리드 X선 제너레이터 (Hybrid Type X-Ray Generator Using EDLC for Fluoroscopy X-Ray System)

  • 서영민;홍순찬
    • 조명전기설비학회논문지
    • /
    • 제28권9호
    • /
    • pp.89-98
    • /
    • 2014
  • A diagnostic fluoroscopy X-ray system uses a 32kW or greater X-ray generator for obtaining real-time moving images and high-resolution images. Fluoroscopy X-ray systems have to use a high-capacity AC power source to perform long-time low-power fluoroscopy and short-time high-power spot exposure. In this paper, we propose a hybrid type X-ray generator for fluoroscopy X-ray system which can perform fluoroscopy and spot exposure with a low-capacity AC power source and an energy storage device. The characteristics of energy storage devices are compared and each energy storage device is modelled to equivalent circuit. And the characteristics of available energy are analyzed as a function of output voltage and power. A 32kW class hybrid X-ray generator with EDLC as an energy storage device for fluoroscopy X-ray system was constructed, and its validity was verified by means of simulations and experiments.

Accuracy and Safety in Pedicle Screw Placement in the Thoracic and Lumbar Spines : Comparison Study between Conventional C-Arm Fluoroscopy and Navigation Coupled with O-Arm$^{(R)}$ Guided Methods

  • Shin, Myung-Hoon;Ryu, Kyeong-Sik;Park, Chun-Kun
    • Journal of Korean Neurosurgical Society
    • /
    • 제52권3호
    • /
    • pp.204-209
    • /
    • 2012
  • Objective : The authors performed a retrospective study to assess the accuracy and clinical benefits of a navigation coupled with O-arm$^{(R)}$ system guided method in the thoracic and lumbar spines by comparing with a C-arm fluoroscopy-guided method. Methods : Under the navigation guidance, 106 pedicle screws inserted from T7 to S1 in 24 patients, and using the fluoroscopy guidance, 204 pedicle screws from T5 to S1 in 45 patients. The position of screws within the pedicle was classified into four groups, from grade 0 (no violation cortex) to 3 (more than 4 mm violation). The location of violated pedicle cortex was also assessed. Intra-operative parameters including time required for preparation of screwing procedure, times for screwing and the number of X-ray shot were assessed in each group. Results : Grade 0 was observed in 186 (91.2%) screws of the fluoroscopy-guided group, and 99 (93.4%) of the navigation-guided group. Mean time required for inserting a screw was 3.8 minutes in the fluoroscopy-guided group, and 4.5 minutes in the navigation-guided group. Mean time required for preparation of screw placement was 4 minutes in the fluoroscopy-guided group, and 19 minutes in the navigation-guided group. The fluoroscopy-guided group required mean 8.9 times of X-ray shot for each screw placement. Conclusion : The screw placement under the navigation-guidance coupled with O-arm$^{(R)}$ system appears to be more accurate and safer than that under the fluoroscopy guidance, although the preparation and screwing time for the navigation-guided surgery is longer than that for the fluoroscopy-guided surgery.

Epidural Injection시술시 투시율 변화에 따른 선량비교연구 (Comparative study of dose due to the change of fluoroscopy pulse rate of Epidural Injection treatment time)

  • 서정범;오동훈;이정범;이종웅
    • 대한디지털의료영상학회논문지
    • /
    • 제15권1호
    • /
    • pp.21-26
    • /
    • 2013
  • To be investigated and measures to reduce the medical exposure of patients to change the Epidural Injection time Fluoroscopy Pulse Rate in this study. Was conducted in 50 patients who underwent surgery Epidural Injection performed by interventional care of Konkuk University Hospital from January to April 2013. The treatment time with the change of Pulse rate, is measured in minutes fluoroscopy time, and measured the area dose (${\mu}Gym^2$) and depth dose (mGy). Using the Image J program, to measure the PSNR and SNR. The fluoroscopy time as a result surgery, there was no significance in the statistical analysis, and depth dose is 34.3 to 34.9%, was reduced from 35.8 to 38.7% the area dose. It is possible to reduce the appropriate Pulse rate, to reduce the dose without statistical analysis significance fluoroscopy time.

  • PDF

투시하에 시행한 고관절 확대계측 촬영술의 유용성에 관한 분석 (A Study on the Usefulness of Total Hip Replacement Arthroplasty Using Fluoroscopy)

  • 이희정;손순룡;엄준용;진정헌;김건중
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제22권1호
    • /
    • pp.21-26
    • /
    • 1999
  • To make a comparative analysis for clinical application of total hip replacement arthroplasty(THRA) using fluoroscopy, we have performed total hip replacement arthroplasty making 30 patients an object with general radiography and fluoroscopy respectively. The results are as follows : 1) Reexamination rate was 80% of patients and mean 3.9 sheets in the general radiography, where as it was 46.7% and 0.37 sheets in the fluoroscopy(p<0.01) 2) Add examination was 2 cases in the general radiography, but fluoroscopy was no add examination. 3) The total film sheet used was mean 10.16 in the general radiography and 6.73 in the fluoroscopy. 4) In the cause of reexmination and add examination, inaccurate position of patient accounted for 72.6% in the general radiography and poor exposure condition accounted for 45.5% in the fluoroscopy. Total hip replacement arthroplasty using the fluoroscopy decreased reexamination and add examination rate, for these reasons, this method was effective abatement of pain, exposured radiation dose, and examination time and so on.

  • PDF

Accuracy of Pedicle Screw Insertion Using Fluoroscopy-Based Navigation-Assisted Surgery : Computed Tomography Postoperative Assessment in 96 Consecutive Patients

  • Lee, Keong Duk;Lyo, In Uk;Kang, Byeong Seong;Sim, Hong Bo;Kwon, Soon Chan;Park, Eun Suk
    • Journal of Korean Neurosurgical Society
    • /
    • 제56권1호
    • /
    • pp.16-20
    • /
    • 2014
  • Objective : Two-dimensional fluoroscopy-based computerized navigation for the placement of pedicle screws offers the advantage of using stored patient-specific imaging data in providing real-time guidance during screw placement. The study aimed to describe the accuracy and reliability of a fluoroscopy-based navigation system for pedicle screw insertion. Methods : A total of 477 pedicle screws were inserted in the lower back of 96 consecutive patients between October 2007 and June 2012 using fluoroscopy-based computer-assisted surgery. The accuracy of screw placement was evaluated using a sophisticated computed tomography protocol. Results : Of the 477 pedicle screws, 461 (96.7%) were judged to be inserted correctly. Frank screw misplacement [16 screws (3.3%)] was observed in 15 patients. Of these, 8 were classified as minimally misplaced (${\leq}2mm$); 3, as moderately misplaced (2.1-4 mm); and 5, as severely misplaced (>4 mm). No complications, including nerve root injury, cerebrospinal fluid leakage, or internal organ injury, were observed in any of the patients. Conclusion : The accuracy of pedicle screw placement using a fluoroscopy-based computer navigation system was observed to be superior to that obtained with conventional techniques.

Merit of Zone III Resuscitative Endovascular Occlusion of the Aorta under Real-Time Fluoroscopy in Hybrid ER: A Case of REBOA in Traumatic Cardiac Arrest

  • Lee, Sung Do;Chung, Seungwoo;Ki, Young Jun;Seo, Sang Hyun;Park, Chan Yong
    • Journal of Trauma and Injury
    • /
    • 제33권3호
    • /
    • pp.191-194
    • /
    • 2020
  • Resuscitative endovascular balloon occlusion of the aorta (REBOA) is a novel technique to maintain proximal arterial pressure. It is important to locate the balloon catheter correctly in performing REBOA but it is inaccurate to check the catheter position by external measurement. Even if the position of the catheter is initially confirmed by X-ray, it is difficult to determine the location of the catheter that changes according to various situations. We performed REBOA under real-time fluoroscopy and could maintain the catheter in correct position under various situations.

Radiation safety for pain physicians: principles and recommendations

  • Park, Sewon;Kim, Minjung;Kim, Jae Hun
    • The Korean Journal of Pain
    • /
    • 제35권2호
    • /
    • pp.129-139
    • /
    • 2022
  • C-arm fluoroscopy is a useful tool for interventional pain management. However, with the increasing use of C-arm fluoroscopy, the risk of accumulated radiation exposure is a significant concern for pain physicians. Therefore, efforts are needed to reduce radiation exposure. There are three types of radiation exposure sources: (1) the primary X-ray beam, (2) scattered radiation, and (3) leakage from the X-ray tube. The major radiation exposure risk for most medical staff members is scattered radiation, the amount of which is affected by many factors. Pain physicians can reduce their radiation exposure by use of several effective methods, which utilize the following main principles: reducing the exposure time, increasing the distance from the radiation source, and radiation shielding. Some methods reduce not only the pain physician's but also the patient's radiation exposure. Taking images with collimation and minimal use of magnification are ways to reduce the intensity of the primary X-ray beam and the amount of scattered radiation. It is also important to carefully select the C-arm fluoroscopy mode, such as pulsed mode or low-dose mode, for ensuring the physician's and patient's radiation safety. Pain physicians should practice these principles and also be aware of the annual permissible radiation dose as well as checking their radiation exposure. This article aimed to review the literature on radiation safety in relation to C-arm fluoroscopy and provide recommendations to pain physicians during C-arm fluoroscopy-guided interventional pain management.

Successful Localization of Intraoral Foreign Body with C-arm Fluoroscopy

  • Kang, Young-Hoon;Byun, June-Ho;Choi, Mun-Jeong;Park, Bong-Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제36권5호
    • /
    • pp.219-223
    • /
    • 2014
  • During surgical procedures, unexpected material, including surgical instruments and tissue segments, may get lost in the surgical field. Most of these should be immediately removed to prevent further complications, such as vital organ irritation, infection, and inflammatory pseudo-tumor formation. However, it is not always easy to define the exact location of the foreign body, especially if the item is very small and/or it is embedded in the soft tissue of the head and neck region. Intraoperative real-time radiological imaging with C-arm fluoroscopy can be useful to trace the three-dimensional location of small and embedded foreign bodies in the oral and maxillofacial area. We describe an unusual case of an embedded micro-screw in the intrinsic tongue muscle that had been dropped into the sublingual space during a lower alveolar bone graft procedure. The lost foreign body was accurately identified with C-arm fluoroscopy and safely removed without any further complications.

Digital subtraction angiography vs. real-time fluoroscopy for detection of intravascular injection during transforaminal epidural block

  • Park, Kibeom;Kim, Saeyoung
    • Journal of Yeungnam Medical Science
    • /
    • 제36권2호
    • /
    • pp.109-114
    • /
    • 2019
  • Background: Transforaminal epidural block (TFEB) is an effective treatment option for radicular pain. To reduce complications from intravascular injection during TFEB, use of imaging modalities such as real-time fluoroscopy (RTF) or digital subtraction angiography (DSA) has been recommended. In this study, we investigated whether DSA improved the detection of intravascular injection during TFEB at the whole spine level compared to RTF. Methods: We prospectively examined 316 patients who underwent TFEB. After confirmation of final needle position using biplanar fluoroscopy, 2 mL of nonionic contrast medium was injected at a rate of 0.5 mL/s under RTF; 30 s later, 2 mL of nonionic contrast medium was injected at a rate of 0.5 mL/s under DSA. Results: Thirty-six intravascular injections were detected for an overall rate of 11.4% using RTF, with 45 detected for a rate of 14.2% using DSA. The detection rate using DSA was statistically different from that using RTF (p=0.004). DSA detected a significantly higher proportion of intravascular injections at the cervical level than at the thoracic (p=0.009) and lumbar (p=0.011) levels. Conclusion: During TFEB at the whole spine level, DSA was better than RTF for the detection of intravascular injection. Special attention is advised for cervical TFEB, because of a significantly higher intravascular injection rate at this level than at other levels.

C-arm 형광투시를 이용한 하악관절돌기골절의 비관혈적 도수정복 (Closed Manual Reduction of Mandibular Condylar Fracture Assisted by C-arm Fluoroscopy)

  • 최의철;강상규;정성균
    • 대한두개안면성형외과학회지
    • /
    • 제10권2호
    • /
    • pp.131-134
    • /
    • 2009
  • 저자들은 보편적으로 보존치료가 불가능 하여 관혈적 정복술이 필요한 하악의 관절돌기골절 증례에서 당뇨, 고혈압의 병력, 고령으로 인한 절개 및 박리, 전신마취 시간증가로 발생할 수 있는 합병증을 줄이기 위해 우선적으로 시행한 형광투시하의 비관혈적 도수정복만으로 정확한 정복에 성공할 수 있었고 이후 골 유합까지 유지하여 만족스런 결과를 얻었기에 보고하는 바이다.