• Title/Summary/Keyword: fluorescent color

Search Result 216, Processing Time 0.027 seconds

A Control Circuit for Blinking and Color Variaton Operations of Fluorescent Lamps (형광램프의 점멸 및 가변색 동작을 위한 제어회로)

  • 송상빈;곽재영;여인선
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.1
    • /
    • pp.28-35
    • /
    • 2001
  • In this paper, an electronic starter and controller are develor:ed for blinking and color variation oI:'||'&'||'pound;fations of fluorescent ]arrps, which would be suitElble for use in an advertising panel. The deve1oporl electrornc starters enable single-pulse ignition for fluorescent lamps of 2O-4Q[W] according to the start signal of controller, and the lamp life is e;.qxccted to go beyond 3,OCO hours with blinking o]:ffations for minimum 0.2[s]. Also, the controller based on a micro-controller can handle up to 128 fluorescent lanlpS and have ten modes of blinking pattems and 7-color variation mxles.

  • PDF

A Conspicuity Effect Study of Fluorescent Orange Color Traffic Sings for Work Zone Application (공사구간 형광주황색 교통안전표지 적용에 따른 주목성 효과 연구)

  • Ko, Sangkeun;Choi, Keechoo;Lee, Sang-Soo;Yun, Ilsoo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.5D
    • /
    • pp.437-444
    • /
    • 2012
  • This study intended to improve traffic safety in work zones using fluorescent orange color traffic signs. For this end, the current problems of existing traffic signs and facilities in work zones were analyzed and some good examples of foreign countries were compared. More specifically, in order to identify current problems, the basic shape and color of traffic signs in use were examined through literature review, surveys and field studies. It was found that the fluorescent color worked more effectively than other colors in terms of visibility and conspicuity in work zone sign system. For evaluation, both Conspicuity surveys and in-door simulator experiments were conducted to effectively assess the merits and demerits of different types of traffic signs for work zones. The results of evaluations showed that black lettering on a fluorescent orange background outperformed more than 70% in terms of visibility and ability to call drivers' attention compared with those from black/red lettering on yellow/white backgrounds currently used at work zones on expressways and national highways. In addition, simulated driving experiment disclosed that drivers recognized the fluorescent orange background sign 15m ahead compared with the yellow background sign and 25m ahead compared with the white background sign, respectively. As for the diamond-shaped "Under Construction" sign, drivers recognized fluorescent orange background 11m ahead compared with the yellow background sign and 19m ahead compared with the white background sign, respectively.

The effect of an EML sequence and an interlayer on the performance of the phosphorescent-fluorescent mixed WOLEDs

  • Baek, Heume-Il;Lee, Chang-Hee
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1215-1218
    • /
    • 2008
  • We investigate the effect of a light emitting layer (EML) sequence and an interlayer on the performance of the phosphorescent-fluorescent mixed white organic light emitting diodes. Two types of phosphorescent-fluorescent mixed system were evaluated. The proper position of each primary color EML was crucial to obtain best performance in each system whereas the effect of an interlayer was found to be different in both systems.

  • PDF

Digital Color Imaging Systems for Quantitative Evaluation of Skin Lesions (피부병변의 정량적 평가를 위한 디지털 컬러 영상 시스템)

  • Han, Byung-Kwan;Jung, Byung-Jo
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.195-198
    • /
    • 2007
  • In this paper, we introduce a digital cross-polarization and fluorescent color imaging system for quantitative evaluation of skin lesions. We describe the characterization of the imaging systems and the quantitative image analysis methods to show the feasibility for quantitative evaluation of skin lesions. The polarization color image was used to compute erythema and melanin index image which are useful for quantitative evaluation of pigmentation and vascular skin lesions, respectively. The fluorescent color image was used to quantitatively evaluate "sebum" and "vitiligo". In quantitative evaluation of various skin lesions, we confirmed the clinical efficacy of the imaging systems for dermatological applications. Finally, we sure that the imaging systems can be utilized as important assistant tools for the evaluation of skin lesions by providing reproducible quantitative result for widely distributed skin lesions.

상동산 SCHEELITE의 특성연구 <특히 Powellite 진부 구명을 위하여>

  • 황재운
    • Journal of the Korean Professional Engineers Association
    • /
    • v.3 no.10
    • /
    • pp.3-6
    • /
    • 1970
  • The scheelite occurred in Sang Dong mine are disseminated with a fine grain, and shelved pale blue or white color under the fluorescence. But among them, We can often observe the yellow fluorescent color mineral grains, which were called the powellite from the past time without any detail mineral study. I studied the characteristics of Sang-Dong scheelite and the so called powellite. In the result, the so called powellite is proved to be the molybdenum bearing scheelite in the view of specific gravity, index of refraction, chemical composition, other microscopic properties, and dressing. Such a scheelite is contained usually Zor 3% Mo, and oftenly 4 or 6% Mo, and fluorescent colors are pale yellow, leman yellow and chrome yellow.

  • PDF

Highly Sensitive Fluorescence Probes for Organic Vapors: On/off and Dual Color Fluorescence Switching

  • An, Byeong-Kwan;Kwon, Soon-Ki;Park, Soo-Young
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.10
    • /
    • pp.1555-1559
    • /
    • 2005
  • High-performance fluorescent probes which exhibit either on/off or dual color fluorescence switching in response to the presence of organic vapors with a rapid response, a high sensitivity and a high-contrast on/off signaling ratio were demonstrated on the basis of the vapor-controlled AIEE phenomenon.

The Effect of Color Reproduction Properties at TFT-LCD using High Color Reproduction CCFL

  • Han, Jeong-Min;Ok, Chul-Ho;Seo, Dae-Shik
    • Transactions on Electrical and Electronic Materials
    • /
    • v.8 no.5
    • /
    • pp.215-217
    • /
    • 2007
  • Recently, color reproduction properties have attracted lots of attention with mass production of LCD especially corresponding to TV application and achievement of color reproduction properties such as CRT have been considered one of technical goals for high quality display. However, revision of the color reproduction properties only with CF(color filter) have fundamental limitations and resultant decrease in the transmittance of panel causes demand on high brightness of BL(Back Light). In this paper, we present such a method in which by optimization of original light spectrum from the BL source will improves the color reproduction properties corresponding to them of the CRT. When the intensity of RED and Green-Blue from ramp is revised densely, the characteristics different from CCFL(Cold Cathode Fluorescent Lamp) used before become added so that about 11 % of the color reproduction properties is improved compare to the existing LCD panel.

Study on full color RGB LED source lighting for general lighting and Improvement of CRI (Color Rendering Index)

  • Park, Yung-Kyung
    • Science of Emotion and Sensibility
    • /
    • v.15 no.3
    • /
    • pp.381-388
    • /
    • 2012
  • The purpose of this study is to check if LED lighting can be used as general lighting and examine the color rendering property of full color RGB LED lighting. CRI is one of the important properties of evaluating lighting. However the present CRI does not fully evaluate LED lightings. Firstly, the performance of a simple task was compared other than comparing CRI values for different lighting. For experimental preparation three types of lightings were used; standard D65 fluorescent tube, general household fluorescent tube, and RGB LED lighting. All three lightings show high error for Purple-Red. All three lightings show similar error for all hues and prove that color discrimination is not affected by the lighting. This proves that LED could be used as general lighting. Secondly, problems of the conventional CIE CRI method are considered and new models are suggested for the new lighting source. Each of the models was evaluated with visual experiment results obtained by the white light matching experiment. The suggested model is based on the CIE CRI method but replaces the color space model by CIELAB, color difference model by CIEDE2000, and chromatic adaptation model by CAT02.

  • PDF

Effects of Correlated Color Temperature of LED Light Sources and a Flourescent Light Source on Visual Performance (LED광원과 형광광원의 상관색온도가 시작업 성능에 미치는 영향)

  • Baik, Seung-Heon;Jeong, In-Young;Shin, Hwa-Young;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.1
    • /
    • pp.18-26
    • /
    • 2009
  • Recently, from an environmental conservative point of view, the need of high-efficiency lighting system, using LED(Light Emitting Diode) light sources have been increased. However, applied LED light sources without regard to its color and pattern provide visual discomfort to occupant. The objective of this study is not only to evaluate the performance of task work under different correlated color temperature condition, but also furnish the preliminary data as concerning its purpose and user of inner space. For the purpose of this study, two types of LED light sources and a fluorescent light source were selected. Thirty undergraduate students served as the participants. Two different task work sheets were conducted to evaluate the accuracy and duration of time. Results from subjective performance, task work of error modification showed that LED light sources were 2.5[%] higher in accuracy with 17.1[%] lower duration than a fluorescent light source. In the case of reading task work, It is presented 20.6[%] decrease with the LED light sources comparison with a fluorescent light source.

Development of Microfluidic Polydiacetylene Sensor Chip for pH detection (pH 검출을 위한 미세유동 폴리디아세틸렌 센서칩 개발)

  • Hwang, Hyun-Jin;Song, Si-Mon
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2415-2418
    • /
    • 2008
  • Polydiacetylenes (PDAs) are very attractive chemical substances which have distinctive features of color change and fluorescence emission by thermal or chemical stress. Especially, when PDAs contact with solutions of a particular pH, such as a strong alkaline sodium hydroxide (NaOH) solution or a strong acidic hydrogen chloride (HCl) solution, PDAs change their color from non-fluorescent blue to fluorescent red. In this study, we propose a novel method to detect alkaline pH using PDAs and NaOH solutions by hydrodynamic focusing on a microfluidic chip. Preliminary results indicate that the fluorescent intensity of PDAs increases in respond to the NaOH solution concentrations. Also, the fluorescence is quenched back when the PDAs are in contact with a HCl solution. These results are useful in a microfluidic PDA sensor chip design for pH detection.

  • PDF