• 제목/요약/키워드: fluorescence detector

검색결과 185건 처리시간 0.028초

UV-Vis 분광분석에 의한 전기변압기 내 절연지 열화도 측정 (Application of UV-Vis Spectroscopic Analysis for Transformer Insulating Paper Degradation)

  • 공호성;한흥구
    • Tribology and Lubricants
    • /
    • 제35권3호
    • /
    • pp.151-157
    • /
    • 2019
  • Insulated oil degradation produces charged by-products, such as acids and hydro-peroxides, which tend to reduce the insulating properties of the oil. In this study, UV-vis spectroscopy measurement technology is developed and experimentally compared with other measurement methods, such as the titration method and IR spectroscopy, to validate its ability to monitor the degradation of electrical insulating paper. The degradation characteristics of the insulating paper are appropriately represented through various types of measurement methods, such as the Tan (delta) method, $CO_2$ gas production measurement, the titration method, and IR spectroscopy. The results are demonstrated to be well comparable to a change in the fluorescence emission ratio (FER), which is defined as the shift in fluorescence intensity in the measured wavelength range, and also to the chromatic ratio, which is defined as a color shift to longer wavelength ranges. The results also show that, by using UV-vis spectroscopy, it is possible to detect the degradation of the insulating paper. This study suggests that UV-vis spectroscopy can be applied as an alternative to high-performance liquid chromatography, which is the internationally recognized measurement technology for cellulose paper degradation. The FER detector is also verified to be useful as an effective condition-monitoring device for power transformers.

The Allosteric Transition of the Chaperonin GroEL from Escherichia coli as Studied by Solution X-Ray Scattering

  • Kuwajima Kunihiro;Inobe Tomonao;Arai Munehito
    • Macromolecular Research
    • /
    • 제14권2호
    • /
    • pp.166-172
    • /
    • 2006
  • This is a short review article of our recent studies on the ATP-induced, allosteric conformational transition of the chaperonin GroEL complex by solution X-ray scattering. We used synchrotron X-ray scattering with a two-dimensional, charge-coupled, device-based X-ray detector to study (1) the specificity of the chaperonin GroEL for its ligand that induced the allosteric transition, and (2) the identification of the allosteric transition of GroEL in its complicated kinetics induced by ATP. Due to the dramatically increased sensitivity of the X-ray scattering technique based on the use of the two dimensional X-ray detector and synchrotron radiation, different allosteric conformational states of GroEL populated under different conditions were clearly distinguished from each other. It was concluded that solution X-ray scattering is an extremely powerful tool for investigating the equilibrium and kinetics of cooperative conformational transitions of oligomeric protein complex, especially when combined with other spectroscopic techniques such as fluorescence spectroscopy.

Development of a multi-modal imaging system for single-gamma and fluorescence fusion images

  • Young Been Han;Seong Jong Hong;Ho-Young Lee;Seong Hyun Song
    • Nuclear Engineering and Technology
    • /
    • 제55권10호
    • /
    • pp.3844-3853
    • /
    • 2023
  • Although radiation and chemotherapy methods for cancer therapy have advanced significantly, surgical resection is still recommended for most cancers. Therefore, intraoperative imaging studies have emerged as a surgical tool for identifying tumor margins. Intraoperative imaging has been examined using conventional imaging devices, such as optical near-infrared probes, gamma probes, and ultrasound devices. However, each modality has its limitations, such as depth penetration and spatial resolution. To overcome these limitations, hybrid imaging modalities and tracer studies are being developed. In a previous study, a multi-modal laparoscope with silicon photo-multiplier (SiPM)-based gamma detection acquired a 1 s interval gamma image. However, improvements in the near-infrared fluorophore (NIRF) signal intensity and gamma image central defects are needed to further evaluate the usefulness of multi-modal systems. In this study, an attempt was made to change the NIRF image acquisition method and the SiPM-based gamma detector to improve the source detection ability and reduce the image acquisition time. The performance of the multi-modal system using a complementary metal oxide semiconductor and modified SiPM gamma detector was evaluated in a phantom test. In future studies, a multi-modal system will be further optimized for pilot preclinical studies.

초고에너지 우주선과 고층대기 극한방전 현상 관측을 위한 TUS(Tracking Ultraviolet Setup) 및 Pinhole Camera 개발 및 진행상황

  • 김민빈;김지은;김예원;나고운;박일흥;서정은;이직;정애라
    • 천문학회보
    • /
    • 제37권2호
    • /
    • pp.209.1-209.1
    • /
    • 2012
  • TUS(Tracking Ultraviolet Setup)는 5x1019 eV 이상의 초고에너지 우주선의 스펙트럼과 그 기원, 그리고 고층대기 극한방전 현상(TLE) 관측을 위한 우주망원경이다. 위성 Lomonosov의 탑재체로 2013년에 발사예정에 있으며 지구로부터 550km 상공에서 지구를 돌며 3년 이상 임무를 수행할 예정이다. TUS는 크게 반사경과 Detector Module 두 부분으로 나뉜다. 7개의 육각형 프레넬 거울을 이용한 $2m^2$ 크기의 반사경과 256개의 PMT(Photo Multiplier Tube)로 구성된 Detector Module을 이용하여 지구 대기에서 초고에너지 우주선에 의해 발생하는 UV fluorescence와 Cherenkov light를 관측한다. TUS Detector Module의 한 부분인 Pinhole Camera는 본 연구단의 기술로 직접 개발한 탑재체로서 TUS 반사경을 통하지 않고 두개의 $8{\times}8$ 어레이 MAPMT (Multi Anode PMT)가 직접 지구를 바라보며 고층대기 극한방전 현상을 관측한다. Pinhole camera는 TUS의 시야각을 포괄하는 넓은 시야각을 가지고 있으며 빠른 트리거 시스템으로 고층대기 극한 방전 현상을 관측하며, 이 방전현상과 TUS가 관측하는 초고에너지 우주선과의 상관 관계를 연구한다. 현재 TUS 및 Pinhole Camera는 러시아에서 조립되어 우주환경 인증 시험 및 인터페이스 테스트가 진행되고 있다. 본 발표에서는 TUS와 Pinhole Camera를 소개하고 현재까지의 진행상황 및 테스트 결과에 대해 보고하고자 한다.

  • PDF

The New X-ray Induced Electron Emission Spectrometer

  • Yu.N.Yuryev;Park, Hyun-Min;Lee, Hwack-Ju;Kim, Ju-Hwnag;Cho, Yang-Ku;K.Yu.Pogrebitsky
    • 한국결정학회:학술대회논문집
    • /
    • 한국결정학회 2002년도 정기총회 및 추계학술연구발표회
    • /
    • pp.5-6
    • /
    • 2002
  • The new spectrometer for X-ray Induced Electron Emission Spectroscopy (XIEES) .has been recently developed in KRISS in collaboration with PTI (Russia). The spectrometer allows to perform research using the XAFS, SXAFS, XANES techniques (D.C.Koningsberger and R.Prins, 1988) as well as the number of techniques from XIEES field(L.A.Bakaleinikov et all, 1992). The experiments may be carried out with registration of transmitted through the sample x-rays (to investigate bulk samples) or/and total electron yield (TEY) from the sample surface that gives the high (down to several atomic mono-layers in soft x-ray region) near surface sensitivity. The combination of these methods together give the possibility to obtain a quantitative information on elemental composition, chemical state, atomic structure for powder samples and solids, including non-crystalline materials (the long range order is not required). The optical design of spectrometer is made according to Johannesson true focusing schematics and presented on the Fig.1. Five stepping motors are used to maintain the focusing condition during the photon energy scan (crystal angle, crystal position along rail, sample goniometer rail angle, sample goniometer position along rail and sample goniometer angle relatively of rail). All movements can be done independently and simultaneously that speeds up the setting of photon energy and allows the using of crystals with different Rowland radil. At present six curved crystals with different d-values and one flat synthetic multilayer are installed on revolver-type monochromator. This arrangement allows the wide range of x-rays from 100 eV up to 25 keV to be obtained. Another 4 stepping motors set exit slit width, sample angle, channeltron position and x-ray detector position. The differential pumping allows to unite vacuum chambers of spectrometer and x-ray generator avoiding the absorption of soft x-rays on Be foil of a window and in atmosphere. Another feature of vacuum system is separation of walls of vacuum chamber (which are deformed by the atmospheric pressure) from optical elements of spectrometer. This warrantees that the optical elements are precisely positioned. The detecting system of the spectrometer consists of two proportional counters, one scintillating detector and one channeltron detector. First proportional counter can be used as I/sub 0/-detector in transmission mode or by measuring the fluorescence from exit slit edge. The last installation can be used to measure the reference data (that is necessary in XANES measurements), in this case the reference sample is installed on slit knife edge. The second proportional counter measures the intensity of x-rays transmitted through the sample. The scintillating detector is used in the same way but on the air for the hard x-rays and for alignment purposes. Total electron yield from the sample is measured by channeltron. The spectrometer is fully controlled by special software that gives the high flexibility and reliability in carrying out of the experiments. Fig.2 and fig.3 present the typical XAFS spectra measured with spectrometer.

  • PDF

2-Bromoacetyl-6-methoxynaphthalene을 형광유도체화제로 HPLC와 SPE를 이용한 생약제제 중 Ursodeoxycholic acid의 정량 (Determination of Ursodeoxycholic Acid in Crude Drug Formulations by HPLC and SPE Using Selective Pre-column Derivatization with 2-Bromoacetyl-6-methoxynaphthalene)

  • 진창화;임수희;이기진;심형섭;조의환;염정록
    • 약학회지
    • /
    • 제46권6호
    • /
    • pp.392-397
    • /
    • 2002
  • A simple and sensitive high performance liquid chromatographic method to quantitate ursodeoxycholic acid in crude drug pharmaceuticals was investigated. Ursodeoxycholic acid react with 2-bromoacetyl-6-methoxynaphthalene (Br-AMN) in the presence of triethylamine to form highly fluorescent derivative. The derivatization procedure was performed at 7$0^{\circ}C$ and completed within 30 min. The optimal wavelength of the fluorescence detector are λ$_{ex}$=300 nm and λ$_{em}$ = 460 nm. The LOD of the ursodeoxycholic acid was 25 ng/mι based on the S/N =3, and the LOQ was 80 ng/mι based on S/N = 10. Crude drug pharmaceuticals pretreated by solid phase extraction (Sep-pak $C_{18}$ cartridge) which were shown very good separation and recovery values for the compound.d.

The pharmacokinetics of tramadol hydrochloride in Korean healthy volunteers

  • Choi, Young-Wook;Lee, Hee-Joo;Han, Sang-Beom;Chun, In-Koo;Gwak, Hye-Sun
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2003년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.1
    • /
    • pp.313.2-314
    • /
    • 2003
  • This study was conducted to investigate the pharmacokinetic characteristics of a synthetic opioid, Tridol\ulcornerCapsule (tramadol hydrochloride from Yuhan Pharmaceutical Co., Ltd., Korea) in 24 healthy Korean volunteers after a single dose administration. The volunteers received two capsules of 50 mg dose. Plasma samples were obtained over a 24-hour interval, and tramadol concentrations were obtained over a 24-hour intervalm and tramadol concentrations were determined by validated HPLC methods with a fluorescence detector. (omitted)

  • PDF

Determination of Prazosin in Human Plasma by a Validated HPLC Method with Application to Single-dose Pharmacokinetics

  • Youngah Cho;Junghyun Oh;Hyesun Gwak;Eunsun Noh;Lee, Nayoung;Inkoo Chun
    • 한국응용약물학회:학술대회논문집
    • /
    • 한국응용약물학회 2003년도 Annual Meeting of KSAP : International Symposium on Pharmaceutical and Biomedical Sciences on Obesity
    • /
    • pp.105-105
    • /
    • 2003
  • A rapid and reproducible high performance liquid chromatographic assay of prazosin in human plasma was developed. After addition of internal standard (IS, terazosin hydrochloride) and alkalization of the plasma, the drug and IS were extracted into t-butylmethylether. The organic phase was back-extracted into 0.05% phosphoric acid and 50 ${\mu}\ell$ of the acid solution was injected into a reverse-phase C18 column with a mobile phase consisting of water : acetonitrile : triethylamine = 75 : 25 : 0.1 (pH 5.0). The samples were detected utilizing a fluorescence detector. A

  • PDF

HPLC를 이용한 뇨 및 혈액중 Metocurine Iodide의 미량분석 (Microanalysis of Metocurine Iodide in Urine and Blood by HPLC)

  • 김경님;이종필;김효진;김박광
    • 약학회지
    • /
    • 제38권4호
    • /
    • pp.379-388
    • /
    • 1994
  • A new method for the analysis of metocurine iodide in biological fluids was developed. Metocurine iodide was quantitatively extracted with rose bengal from aqueous layer into dichloromethane layer and the amount of metocurine iodide was calculated from the amount of rose bengal which was determined by HPLC with fluorescence detector. It was possible to analyze metocurine iodide without the effect of co-prescribed drugs in the concentration range of $0.09{\sim}9.10\;{\mu}g/ml$. The detection limits of metocurine iodide in urine and blood were 0.8 and 1.2 ng at S/N=3, each respectively.

  • PDF

새로운 HPLC용 형광유도체화제인 1-(N,N-dimethylamino) pyrene-6-sulfonyl chloride를 이용한 아민화합물의 분석 (Determination of Amine Compounds Using 1-(N,N-Dimethylamino) pyrene-6-sulfonyl chloride as a New Fluorescent Derivatizing Reagent for HPLC)

  • 이윤중;김용희;조정길
    • 약학회지
    • /
    • 제35권4호
    • /
    • pp.288-294
    • /
    • 1991
  • A new fluorescent derivatizing reagent was developed to be used in HPLC for the trace determination of primary and secondary amines. This new reagent, 1-(N,N-dimethylamino)pyrene-6-sulfonyl chloride, was synthesized by the chlorination of sodium 1-(N,N-dimethylamino)pyrene-6-sulfonate which was obtained from 1-(N,N-dimethylamino)pyrene after sulfonation. Ephedrine and norephedrine were derivatized quantitatively by this reagent. The optimum conditions for the derivatization such as pH, reagent concentration, reaction time and reaction temperature ware examined. The structures of derivatives were identified by IR, $^{1}$H-NMR and MS methods. The fluorescence properties and the stability of the derivatives were examined. The derivatives were separated on silica column with an isocratic elution using the mixture of n-hexane and ethylacetate and monitored by fluorescene detector. Linear calibration curves were obtained and detection limits in a 10 $\mu$l injection volume were 5 picomole for ephedrine and norephedrine.

  • PDF