• Title/Summary/Keyword: fluidity

Search Result 1,021, Processing Time 0.032 seconds

Adsorption and Fluidity Properties of Recycled Cement Powder (재생미분말의 흡착특성과 유동특성)

  • Lee, Jong-Kyu;Chu, Yong-Sik;Jung, Suk-Jo
    • Journal of the Korean Ceramic Society
    • /
    • v.43 no.12 s.295
    • /
    • pp.846-851
    • /
    • 2006
  • This paper discuss the adsorption and fluidity properties of recycled cement powder with different hydration hysteresis and particle size. Reactivity of hydrated fine powder was negligible low. Therefore, the adsorption and fluidity properties with super-plasticizer for hydrated recycled cement powder was very important for using additive material. Adsorption amount of super-plasticizer was increased by the finer hydrated recycled cement powder addition. And the fluidity of hydrated recycled cement powder was very poor than un-hydrated cement powder. To Improve the fluidity of hydrated recycled cement powder, PC super-plasticizer is the more effective than NS super-plasticizer.

A Study on Fluidity ability, Filling ability Properties of High Fluidity Concrete with Illite Powder (일라이트 미분말을 혼입한 고유동 콘크리트의 유동성 및 충전성에 관한 연구)

  • Lee, Dong-Un;Lee, Maeng-Gyo;Park, Hyun-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8363-8369
    • /
    • 2015
  • This study is to be investigate properties of workability, compacting and compressive strength replaced by the illite powder in high fluidity concrete. For this purpose, illite powder has replaced the binder of high fluidity concrete of 5%, 10%, 15%, 20%. After concrete mixing, slump flow test, reach time slump flow 500mm, O-lot test were conducted on fresh high fluidity concrete. And compressive strength was determined 28 days for the hardened high fluidity concrete specimens. According to the test results, the workability, filling height of high fluidity concrete were increased in 10% replacement of illite powder. Furthermore, the compressive strength of high fluidity concrete was increased in 10% replacement of illite powder.. It was possible to confirm that optimal mixture ratio of illite powder seems to exist, and it is shown to be 10% according to our experimental results.

Evaluation of Filling Performance of Steel Concrete Panel (SCP) Mock-up Member with Low-binder based High-fluidity Concrete (저분체 기반 고유동 콘크리트의 Steel Concrete Panel Mock-up 부재 충전 성능 평가)

  • Park, Gi Joon;Park, Jung Jun;Kim, Sung Wook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.4
    • /
    • pp.477-483
    • /
    • 2019
  • Recently, precast type SCP modules are being used instead of PSC structures in order to reduce the construction period and costs of special structures such as nuclear power plants and LNG storage tanks. The inside of the SCP module is connected with a stud for the integral behavior of the steel and concrete, and the use of high fluidity concrete is required. High fluidity concrete generally has a high content of binder, which leads to an increase in hydration heat and shrinkage, and a problem of non-uniform strength development. Therefore, in this study, fluidity and passing performance of high fluidity concrete according to material properties are investigated to select optimum mix design of low binder based high fluidity concrete. Mechanical properties of high fluidity concrete before and after pumping are examined using pump car. The filling performance of SCP mock-up members was evaluated by using high fluidity concrete finally.

A Fundamental Study on the Estimation of Construction Cost of High Fluidity Concrete Applying Flowing Concrete Method (유동화공법에 의해 제조한 고유동 콘크리트의 원가분석에 관한 기초적 연구)

  • 한민철;손성운;오선교;김성수;한천구
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2002.11a
    • /
    • pp.99-102
    • /
    • 2002
  • This paper discusses the estimation of construction cost of high fluidity concrete using segregation reducing type superplasicizer with 350kgf/cm2 of design strength and 60$\pm$5cm of slump flow in order to verify the cost down effect of high fluidity concrete compared with that of plain concrete with 350kgf/cm2 of design strength and 18cm of slump and with 210kgf/cm2 of design strength and 15cm of slump. According to research, under same strength levels, although material cost of high fluidity concrete is somewhat higher than that of plain concrete due to segregation reducing type superplasticizer, labor cost and equipment cost of high fluidity concrete is cheaper than that of plain concrete. However, based on the strength differences, high fluidity concrete shows lower material cost, labor cost and equipment cost than that of plain concrete due to decreasing in size of member and re-bar caused by high strength development of concrete.

  • PDF

Effects of Pressure, Superheat and Si Content on the Fluidity of Al-Si Alloy during Squeeze Casting (Al-Si 합금의 용탕 단조시 유동도에 미치는 압력, 과열 및 규소 함량의 영향)

  • Lee, Hag-Ju;Jung, Ki-Hwan;Kwon, Hae-Wook
    • Journal of Korea Foundry Society
    • /
    • v.26 no.3
    • /
    • pp.133-139
    • /
    • 2006
  • The effects of applied pressure, superheat and silicon content on the fluidity of Al-Si alloy during squeeze casting were investigated. The Fluidity of Al-7.0wt%Si alloy during squeeze casting was increased with applied pressure up to 60 MPa, meanwhile it rather decreased beyond that. Therefore, the optimum squeeze casting pressure was 60 MPa. The fluidity was increased with superheat up to $150^{\circ}C$. On the other hand, it rather decreased at the superheat of $200^{\circ}C$. The fluidity of Al-Si alloy during squeeze casting was decreased with silicon content in the range of $0.0{\sim}3.0\;wt%$, increased in the range of $3.0{\sim}13.0\;wt%$. The fluidity of Al-15.0 wt%Si alloy was lower than that of Al-13.0 wt%Si alloy.

Effect of Lipid Peroxidation on the Fluidity of Erythrocyte Ghost and Phospholipid Liposomal Membranes

  • Han, Suk-Kyu;Kim, Min;Park, Yeong-Hun;Park, Eun-Ju;Lee, Jeong-Hee
    • Archives of Pharmacal Research
    • /
    • v.15 no.4
    • /
    • pp.309-316
    • /
    • 1992
  • The effects of lipid peroxidation on the fluidity of the lipid bilayers of the human erythrocyte ghosts and egg-lecithin phospholipid liposomes have been studied. For the measurements of the peroxidation extent and the fluidity of the membranes, the thiobarbituric acid-reactive substances and the fluorescence depolarization of 1, 6-diphynyl-1, 3, 5-hexatriene labelled into the membrane were employed, respectively. The lipid peroxidation was performed in hypoxanthine/xanthine oxidase/ferrous ion, and hydrogen peroxide/ferrous ion systems. The results of these experiments show that both of the xanthine oxidase and hydrogen peroxide systems effectively. The lipid peroxidation decreased the fluidity of the membranes, especially at the very early stage of the peroxidation reaction. The decrease in the fluidity of membrane by the lipid peroxidation has been ascribed to the alteration of the polyunsaturated acyl chains of lipids and cross linkages among the membrane components. However, under drastic condition of lipid peroxidation, tdhe fluidity of the membrane rather increased possibly due to the deterioration of the membrane integrity by the peroxidation. Morphological change of the erythrocyte on peroxidation has also been observed.

  • PDF

Variation of Fluidity and Mechanical Properties of Al-Mg Alloys with the Addition of Si, Mn, and Zn (합금원소 Si, Mn, Zn 첨가에 따른 Al-Mg 합금의 유동도 및 기계적 성질 변화)

  • Kim, Jeong-Min;Seong, Ki-Dug;Jun, Joong-Hwan;Kim, Ki-Tae;Jung, Woon-Jae
    • Journal of Korea Foundry Society
    • /
    • v.24 no.3
    • /
    • pp.138-144
    • /
    • 2004
  • Effects of alloying elements such as Si, Mn, Zn on the fluidity and mechanical properties of high ductility Al-Mg based alloys were investigated. The fluidity of alloys was evaluated using a vacuum suction fluidity test, and Si addition was observed to increase the fluidity of AI-Mg binary alloys substantially while Zn somewhat decreased the fluidity. However, both the strength and ductility were significantly deteriorated by the Si additions. It was observed that a small amount of Mn addition to Al-Mg alloy increased the tensile strength effectively without losing much ductility but the effect of Zn addition on the strength was relatively small.

Fluidity Changes of Cement Paste added Superplasticizer and Inorganic Fine Powders for Cement Admixture (고유동화제와 시멘트 혼화용 무기미분체가 첨가된 시멘트 페이스트의 유동성 변화)

  • 김도수;정흥호;박병배;노재성
    • Journal of the Korean Ceramic Society
    • /
    • v.37 no.8
    • /
    • pp.751-759
    • /
    • 2000
  • Effects of the dosage change, from 0 to 2.0 wt% based on cement weight, of naphthalenic (NSF) and polycarboxylic(NT-2) superplasticizers, on the fluidity of cement paste substituted by 10 wt% II-anhydrite and fly ash respectively as well as II-anhydrite and fly ash itself were investigated. Dispersion properties between particles in suspension were investigated by zeta potential test. Initial fluidity and slump loss in the paste system were observed through mini-slump and apparent viscosity changes with elapsed time. Zeta potential on the particle surface was a tendency to increase according to increasing of NSF dosage. Especially, zeta potential of fly ash has the highest value among all particles equivalent to NSF dosage. In the fluidity of cement paste substituted by inorganic particles, the specimen with substitution of 10 wt% II-anhydrite and fly ash for cement was more effective than cement itself to improve initial fluidity and retain stable fluidity of cement paste. In addition, effect of NT-2 and NSF to improve the fluidity of cement paste, addition of 1.0 wt% NT-2 was more effective than 1.5wt% NSF.

  • PDF

A Fundamental Study on the Properties of High-Fluidity Concrete Using Viscosity Agent - Properties of Hardened Concrete - (증점제를 이용한 고유동콘크리트의 특성에 관한 기초적 연구 -경화상태의 특성-)

  • 김기철;박상준;조병영;윤기원;최응규;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.04a
    • /
    • pp.198-201
    • /
    • 1996
  • The purpose of this study is to analyze the properties of high fluidity concrete using the viscosity agent of a cellulose system with W/C of 35~50% in hardened state. It is proven that properties of high fluidity concrete in hardened state is nearly the same with normal concrete in the same W/C and no strength difference by tamping method do not appeared. Therefore, no tamping method is thought to be reguired in high fluidity concrete.

  • PDF

Evaluation of the Fluidity of Fly Ash Cement Paste (플라이 애시 혼합 시멘트 페이스트의 유동성 평가)

  • 이승헌;김홍주;판정열;대문정
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10b
    • /
    • pp.1221-1226
    • /
    • 2000
  • Influence of characters of fly ash on the fluidity of cement paste with polycarboxylic acid type superplasticizer has been investigated in connection with the particle size of distribution, unburned carbon content, specific surface area and shape of fly ash. The fluidity of paste is increased with increasing roundness of fly ash and it is decreased with increasing n-value of Rosin-Rammler distribution function. There is a linear correlation between roundness/n-value and fluidity of fly ash cement paste.