• 제목/요약/키워드: fluid system

검색결과 5,212건 처리시간 0.039초

계지탕(桂枝湯) 방후주문(方後註文)에 관한 연구(硏究) (A study on post-formula instruction of Kyejitang(桂枝湯))

  • 김강;맹웅재
    • 한국의사학회지
    • /
    • 제23권1호
    • /
    • pp.23-41
    • /
    • 2010
  • Greater yang disease(太陽病) is a syndrome induced by peripheral obstruction. One of them is "wind stroke(中風)" with the obstruction in lymphatic system. The other obstruction appearing on circulatory system is called "cold damage(傷寒)." Kyejitang(桂枝湯) is the formula prescribed for greater yang wind stroke pattern(太陽中風證) which is caused by peripheral lymphatic duct obstruction. Ramulus Cinamoni acts as a vasodilator and Radix Paeoniae relieves the abdominal tension. They make blood move to the internal organ and this can remove the retention of peripheral lymphatic system. Covering the patient with a blanket and getting him/her to have hot and thin rice gruel causes slight Diaphoresis, contributing to relieving the retention of lymphatic system. Disharmony between nutrient and defense(營衛不和) means that pressure becomes different between lymphatic system and vascular system. Kyejitang(桂枝湯) is called releasing muscles formula(解肌劑) because it can resolve such pressure difference. Diaphoresis is not a means to eliminate pathogenic qi(邪氣) from the body. That is the syndrome proving that the body fluid has moved around when disordered fluid distribution is corrected. Therefore, diaphoresis should be induced weakly all the time. If diaphoresis is induced excessively, body fluid will move more than desired and then illness cannot be cured. In Sanghanlun(傷寒論), dispersing drugs aim at addressing the retention in the exterior field, but it actually applies to the entire exterior and interior to make body fluid move. Therefore, diaphoresis does not just act on exterior field, and freeing the stool does not only apply to interior field. Distribution of body fluid changed by pathogenic qi(邪氣) influences the whole body because the human body has a closed circulatory system. Sanghanlun(傷寒論) has included treatments for pathogenic disease. However, its value should not be limited to pathogenic disease. It is because controlling blood flow by sending body fluid to the place a doctor wants is certainly worth using for treatment of non-exogenous disease or chronic illnesses.

Passive control system for seismic protection of a multi-tower cable-stayed bridge

  • Geng, Fangfang;Ding, Youliang;Song, Jianyong;Li, Wanheng;Li, Aiqun
    • Earthquakes and Structures
    • /
    • 제6권5호
    • /
    • pp.495-514
    • /
    • 2014
  • The performance of passive control system for the seismic protection of a multi-tower cable-stayed bridge with the application of partially longitudinal constraint system is investigated. The seismic responses of the Jiashao Bridge, a six-tower cable-stayed bridge using the partially longitudinal constraint system are studied under real earthquake ground motions. The effects of the passive control devices including the viscous fluid dampers and elastic cables on the seismic responses of the bridge are examined by taking different values of parameters of the devices. Further, the optimization design principle of passive control system using viscous fluid dampers is presented to determine the optimized parameters of the viscous fluid dampers. The results of the investigations show that the control objective of the multi-tower cable-stayed bridge with the partially longitudinal constraint system is to reduce the base shears and moments of bridge towers longitudinally restricted with the bridge deck. The viscous fluid dampers are found to be more effective than elastic cables in controlling the seismic responses. The optimized parameters for the viscous fluid dampers are determined following the principle that the peak displacement at the end of bridge deck reaches to the maximum value, which can yield maximum reductions in the base shears and moments of bridge towers longitudinally restricted with the bridge deck, with slight increases in the base shears and moments of bridge towers longitudinally unrestricted with the bridge deck.

A Study on Ferro Fluid Dynamic Bearing Spindel Characteristics by High Frequency Vibration Ssystem

  • Miwa, M.;Harita, H.;Nishigami, T.;Kaneko, R.;Unozawa, H.
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 proceedings of the second asia international conference on tribology
    • /
    • pp.283-284
    • /
    • 2002
  • Ball bearings (BB) are generally used in spindle of‘ disk drives at present, but they have been known that BB generate high frequency vibration. Fluid dynamic bearings (FDB) having high-rotational accuracy and small vibration characteristics have been developed as next generation spindles. Especially. a ferro fluid bearing (FFB) spindle has the advantage to prevent leakage and dispersion of lubricating oil using a ferro seal. In this study, we measured damping characteristics and frequency characteristics of these bearing spindles using a high-frequency vibration base. High frequency excitation was added to these bearing spindles mounted on the vibration base, and we proved that FFB and FDB spindles have effective damping.

  • PDF

도시철도 소음저감을 위한 MFI(Multi Fluid Injection) 시스템 개발 및 효과에 관한 연구 (A Study on the Development of MFI(Multi Fluid Injection) System and its Effect to Reduce the Noise of Subway)

  • 박종화;김대석;김희오;심재규
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.446-454
    • /
    • 2011
  • The noise of the subway has become a social issue and includes very complex reasons. The friction between rail and train wheel is the most important reason of the noise. In this study, we developed MFI(Multi Fluid Injection) System which sprays the mixed fluid(water, anticorrosive and lubricant) on the rail when the train is approaching to reduce the friction. To verify the system's effect, we measured the internal and external noise of the running train. The measured and analyzed results show that MFI system reduce the noise of the running subway.

  • PDF

Stability Analysis of an Accelerator-Driven Fluid-Fueled Subcritical Reactor System

  • Kim, Do-Sam;Cho, Nam-Zin
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 춘계학술발표회논문집(1)
    • /
    • pp.90-95
    • /
    • 1997
  • In this work, linear dynamics of a circulating fluid-fueled subcritical reactor system with temperature feedback and external neutron source was modeled and examined. In a circulating fluid-fuel system, the stable region is slightly moved by a circulation fluid effect. The effects of subcriticality and temperature feedback coefficient on the reactor stability were tested by calculating frequency response of neutron density originated from reactivity perturbation or external source oscillation of system. The amplitude transfer function has a different shape near subcritical region due to the exponential term in the transfer function. The results of the study show that at a slightly subcritical region, low frequency oscillation in accelerator current or reactivity can be amplified depending on the temperature feedback. However, as the subcriticality increases, the oscillation becomes negligible regardless of the magnitude of the temperature feedback coefficient.

  • PDF

ER 유체를 이용한 반능동식 가변댐퍼의 성능해석 (Performance Analysis of a Semi-Active Variable Damper Featuring Electro-Rheological Fluids)

  • 최승복;정재천;최용빈;허승진;서문석
    • 한국자동차공학회논문집
    • /
    • 제1권1호
    • /
    • pp.90-100
    • /
    • 1993
  • This paper presents some inherent characteristics of a semi-active variable damper featuring electro-rheological (ER) fluid. The damping force of the damper can be selectively adjusted or controlled by employing electric field to the ER fluid domain. This is possible owing to the pressure drop across the piston occured by field-dependent variable yield stress of the ER fluid. This is fundamentally different than the performance of a conventional adjustable viscous damper. To demonstrate the effectiveness and superiority over the conventional one, the proposed damper is incorporated with a suspension system. A quarter car model with the suspension system is formulated and represented by a state equation. By choosing numerical values based on realistic package size, power requirements and suitable ER properties, the performance characteristics of the suspension system are obtained and evaluated in both frequency and time domains. The effects of constant electric field and on-off controlled electric field which relates to the damping force are also examined.

  • PDF

PSD 설계를 위한 성능 시험장치 (Performance Test System for PSD Design)

  • 고광웅;이한주;정동운;이상용;오승협
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2003년도 제20회 춘계학술대회 논문집
    • /
    • pp.119-122
    • /
    • 2003
  • In this Study, the types of PSD performance test systems were reviewed. And as a results of that reviewing process, a suitable PSD performance test system type for PSD design was proposed. PSD performance test systems can be classified with pulsating methods - the pulsating whole feeding system and the pulsating working fluid. The pulsating working fluid method can be re-classified with the devices of pulsating working fluid - a piston-type pulsator and a restrict-type pulsator. The pulsating-working-fluid performance test system with restrict-type pulsator was proposed to be a suitable type for identification of main-design-parameters.

  • PDF

Boussinesq equations for internal waves in a two-fluid system with a rigid lid

  • Liu, Chi-Min
    • Ocean Systems Engineering
    • /
    • 제6권1호
    • /
    • pp.117-128
    • /
    • 2016
  • A theoretical study of Boussinesq equations (BEs) for internal waves propagating in a two-fluid system is presented in this paper. The two-fluid system is assumed to be bounded by two rigid plates. A set of three equations is firstly derived which has three main unknowns, the interfacial displacement and two velocity potentials at arbitrary elevations for upper and lower fluids, respectively. The determination of the optimal BEs requires a solution of depth parameters which can be uniquely solved by applying the $Pad{\acute{e}}$ approximation to dispersion relation. Some wave properties predicted by the optimal BEs are examined. The optimal model not only increases the applicable range of traditional BEs but also provides a novel aspect of internal wave studies.

유체의 유량 및 유속 측정 시스템 개발에 관한 연구 (A Study on the Development of Measurement System for Fluid Volume and Flow Rate)

  • 이석원;이태진;남윤석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 D
    • /
    • pp.2492-2494
    • /
    • 2003
  • Urine analysis is one of the most important medical examination in the hospital. Not only the data for the ingredients of urine through chemical analysis, but also the data related to fluid dynamics, e.g., peak flow rate, average flow rate, may provide some useful information about patient's state of health. Therefore, we develop the portable system to measure and analyse fluid volume/flow rate in this study. This system can store and print the measured data during the pre-specified time interval, and provide some meaningful data related with fluid dynamics. We explain the method and the technical stuff to implement the system, and show the result.

  • PDF