• Title/Summary/Keyword: fluid and flow

Search Result 7,251, Processing Time 0.032 seconds

Advanced Flow Visualization Technologies and Blue Ocean Strategy (첨단 유동가시화 기법들과 Blue Ocean 전략)

  • Lee, Sang-Joon
    • Journal of the Korean Society of Visualization
    • /
    • v.4 no.2
    • /
    • pp.3-5
    • /
    • 2006
  • Recently, the next-generation advanced flow visualization techniques such as holographic PIV, aynni.c PIV, echo-PIV, micro/nano-PIV, and X-ray PIV have been introduced. These advanced mea-surement techniques have a big potential as the core technology for analyzing outmost thermo-fluid flows in future. They would be indispensable in solving complicated thermo-fluid flow problems not only in industrial fields such as automotive, space, electronics, aero- and hydro-dynamics. steel, and information engineering, but also in the research fields of medical science, bio-medical engineering, environmental and energy technology etc. Especially, NT (Nano Technology) and BT (Bio Technology) strongly demand these advanced measurement techniques, because it is impossible for conventional measurement methods to observe the nano- and bio-fluidic flow phenomena. In this article, the basic principle of these high-tech flow visualization techniques and their practical applications which cannot be resolved by conventional methods, such as blood flows in a micro-tube, in vivo analysis of micro-circulation, and flow around a living body are introduced as a blue ocean strategy.

  • PDF

A NOTE ON THE UNSTEADY FLOW OF DUSTY VISCOUS FLUID BETWEEN TWO PARALLEL PLATES

  • AJADI SURAJU OLUSEGUN
    • Journal of applied mathematics & informatics
    • /
    • v.18 no.1_2
    • /
    • pp.393-403
    • /
    • 2005
  • We study the isothermal flow of a dusty viscous incompressible conducting fluid between two types of boundary motions- oscillatory and non-oscillatory, under the influence of gravitational force. Within the frame work of some physically realistic approximations and suitable boundary conditions, closed form solutions were obtained for the velocity profiles and the skin friction of the particulate flow. These results show that for a constant pressure gradient, only the velocity profile of the fluid and the skin friction are unaffected by gravity, while magnetic field is seen to affect both the fluid, particle velocities and the skin friction. Thus, our results are extension of previous results in literature, and graphical demonstration of some these solutions have been presented.

A Numerical Simulation of Heat and Fluid Flow in the Motor Block Room of a Motorized Car (동력객차 동력실 내부의 열유체 유동의 수치 시뮬레이션)

  • 김학범;허재경;이기열
    • Proceedings of the KSR Conference
    • /
    • 1998.11a
    • /
    • pp.589-594
    • /
    • 1998
  • Heat and fluid flow in the motor block room of a motorized car is numerically simulated. The motorized car, composed of a motor block room and a passenger room, supplies additional Power to achieve the design speed. A motor block, a transformer, and a fan are equipped in the motor block room. Flow phenomena in the ducts on the motor block and power transformer are investigated. Also, the three dimensional heat and fluid flow in the motor block room is simulated to give a qualitative information of the flow characteristics.

  • PDF

Hall Effect on Couette Flow with Heat Transfer of a Dusty Conducting Fluid Between Parallel Porous Plates Under Exponential Decaying Pressure Gradient

  • Attia Hazem A.
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.569-579
    • /
    • 2006
  • In the present study, the unsteady Couette flow with heat transfer of a dusty viscous incompressible electrically conducting fluid under the influence of an exponential decaying pressure gradient is studied without neglecting the Hall effect. The parallel plates are assumed to be porous and subjected to a uniform suction from above and injection from below while the fluid is acted upon by an external uniform magnetic field is applied perpendicular to the plates. The governing equations are solved numerically using finite differences to yield the velocity and temperature distributions for both the fluid and dust particles.

PIV Investigations of the Flow Mixing Enhancement by Pulsatile Flow in a Grooved Channel (맥동유동에 의한 그루브 채널내 유동혼합 촉진에 관한 PIV 이용 연구)

  • 김동욱;김서영;이대영;이윤표
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.4
    • /
    • pp.324-331
    • /
    • 2004
  • Particle Image Velocimetry (PIV) measurements have been carried out to investigate the pulsatile flow characteristics in a triangular grooved channel. The results showed that a vortex was generated at the tip of the groove and flowed into the groove rotating inside during the acceleration phase of the main stream promoting the mixing of the fluid. Then, at the deceleration phase of the main stream, the vortex entrained fluid from the relatively slow moving main stream to grow bigger than the groove size. Finally the vortex was ejected to the main stream carrying the fluid away from the groove, resulting in the enhancement of mixing between the stagnant fluid in the groove and the main stream in the channel. It was found that the fluid mixing enhancement is maximized when the pulsatile period is the same as the time duration which the vortex takes to grow larger enough to fill the groove and to be ejected to the main stream.

Study on Fluid Flow in Rectangular Duct past $90^{\circ}$ Mitered Elbow (사각덕트내 직각엘보우를 지난 유체유동에 관한 연구)

  • 윤영환;배택희;박원구
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.26 no.6
    • /
    • pp.670-678
    • /
    • 2002
  • Fluid flow in a rectangular duct with $90^{\circ}$ mitered elbow is measured by 5W laser doppler velocity meter. The fluid flow is also computed by commercial software of STAR-CD for comparison between measured and computed velocity profiles in the duct. Reynolds numbers for the comparison are 1,608 and 11,751 based on mean velocity and hydraulic diameter of the duct. First, the fluid flow of Reynolds number equal to 1,608 is predicted by assumptions of both laminar and turbulent models. But, even though the Reynolds number is less than 2,300~3,000, the computation by turbulent model is closed to the experimental data than that by laminar model. Second, the computation for Reynolds number of 11,751 by turbulent model also predicted the experimental data satisfactorily.

EXTENSION OF AUSMPW+ SCHEME FOR TWO-FLUID MODEL

  • Park, Jin Seok;Kim, Chongam
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.17 no.3
    • /
    • pp.209-219
    • /
    • 2013
  • The present paper deals with the extension of AUSMPW+ scheme into two-fluid model for multiphase flow. AUSMPW+ scheme is the improvement of a single-phase AUSM+ scheme by designing pressure-based weighting functions to prevent oscillations near a wall and shock instability after a strong shock. Recently, Kitamura and Liou assessed a family of AUSM-type schemes with two-fluid model governing equations [K. Kitamura and M.-S. Liou, Comparative study of AUSM-Family schemes in compressible multi-phase flow simulations, ICCFD7-3702 (2012)]. It was observed that the direct application of the single-phase AUSMPW+ did not provide satisfactory results for most of numerical test cases, which motivates the current study. It turns out that, by designing pressure-based weighting functions, which play a key role in controlling numerical diffusion for two-fluid model, problems reported in can be overcome. Various numerical experiments validate the proposed modification of AUSMPW+ scheme is accurate and robust to solve multiphase flow within the framework of two-fluid model.

Helical flow of Newtonian and non-Newtonian fluid in an nnulus (뉴튼 및 비뉴튼 유체의 헬리컬 유동에 관한 연구)

  • Woo, Nam-Sub;Seo, Byung-Taek;Bae, Kyung-Su;Hwang, Young-Kyu
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1634-1639
    • /
    • 2004
  • The present study concerns a experimental study of fully developed laminar flow of a Newtonian and non-Newtonian fluid through a concentric annulus with a combined bulk axial flow and inner cylinder rotation for the various radius ratio. This study shows the fundamental difference between Newtonian and non-Newtonian fluid flow in an annulus for various radius ratio.

  • PDF

Modeling of Nozzle Flow Inside a Y-JET Twin-Fluid Atomizer (Y-JET 2-유체 분무노즐 내부유동의 모델링)

  • In, Wang-Kee;Lee, Sang-Yong;Song, Si-Hong
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.7 s.94
    • /
    • pp.1841-1850
    • /
    • 1993
  • A simplified one-dimensional analysis has been performed to predict the local pressure distributions in Y-Jet twin-fluid atomizers. Fluid compressibility was considered both in the gas(air) and two-phase(mixing) ports. The annular-mist flow model was adopted to analyze the flow in the mixing port. A series of experiments also has been performed; the results show that the air flow rate increases and the liquid flow rate decreases with the increase of the air injection pressure and/or with the decrease of the liquid injection pressure. From the measured injection pressures and flow rates, the appropriate constants for the correlations of the pressure loss coefficients and the rate of drop entrainment were decided. The local pressures inside the nozzle by prediction reasonably agree with those by the experiments.

A Numerical Study on Flow Analysis of a Valveless Bidirectional Piezoelectric Micropump (밸브 없는 양방향 피에조 마이크로펌프의 유동해석)

  • Lee, Sang-Hyuk;Hur, Janet;Hur, Nahm-Keon
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.3
    • /
    • pp.14-21
    • /
    • 2008
  • A numerical simulation on the flow field of a valveless bidirectional piezoelectric micropump has been performed. In this type of micropump, the oscillation of the piezoelectric diaphragm generates the blowing and suction flow through the oblique channel from the pumping chamber. The angle between the oblique and main channel causes the variation of flow distribution through upstream and downstream channels in suction and blowing modes. In the suction flow mode, the working fluid flows from both the upstream and downstream of the main channel to the pumping chamber through the oblique channel. However, in the blowing flow mode, the fluid pushed out of the pumping chamber flows more toward the downstream of the main channel due to the inertia of the fluid. In the present study, the effects of geometries such as the angle of oblique channel and the shape of main channel on the flow rate of the up/downstream were investigated. The flow rate obtained from the pump and the energy required to the pump were also analyzed for various displacements and frequencies of the oscillation of the diaphragm.