• Title/Summary/Keyword: fluid and flow

Search Result 7,252, Processing Time 0.034 seconds

A Numerical Study on the Reduction of Water Hammering in a Simple Water Supply Pipe System

  • Lim, Ki-Won;Cha, Dong-Jin
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.2
    • /
    • pp.51-61
    • /
    • 2001
  • A numerical study has been conducted to characterize the transient pressure in a simple water supply pipe system with an air chamber by utilizing a commercial code that employs the method of characteristics. Some results produced for validation in the study agree quite well with the previously reported. Several parameters are than varied. Among them are the valve closure time, the wave speed, the static pressure, the polytropic exponent, the air chamber volume, the diameter and the shape of orifice in the air chamber, etc, while the water temperature and velocity are kept constant at $20^\circ{C}$ and 0.8m/s, respectively. Results reported in this parametric study may be useful to understand the unsteady behavior of the system.

  • PDF

Thermal Comfort and Air Flow Patterns for Indoor Unit Positions and Ventilation Rates in Cooling Operation (냉방조건에서 실내기 위치 및 환기량에 따른 열쾌적성 및 유동 특성)

  • Koh, Jae-Yoon;Kang, Tae-Wook;Park, Yool
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.4
    • /
    • pp.221-229
    • /
    • 2008
  • This study analyze indoor thermal comfort properties such as PMV, PPD and fluid variables when the cooling loads are light, occupant and ventilation. There are 6 cases to study for the indoor unit installation conditions and ventilation rates. Numerical method is used to study the indoor environmental properties and experimental study is adapted to analyze reaching time by variable cooling load conditions.

Numerical analysis for the optimum design of a triple-glazed airflow window (환기식 3중 집열창의 최적설계를 위한 수치해석 연구)

  • Kim, H.J.;Hwang, K.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.4
    • /
    • pp.484-496
    • /
    • 1997
  • The fluid flow and heat transfer characteristics of conjugate forced and natural convection in the triple-glazed airflow window, where the outer air passes through a space contrived between the interior and exterior window panes, were studied numerically by a finite volume method for the elliptic form of the Navier-Stokes equations. The investigation focused on the influence of window geometry, ventilastion rate and solar energy on the temperature, velocity distribution and thermal performance of the airflow window. The comparison between the triple-glazed airflow window and the enclosed triple-glazed window was also made to evaluate the effect of buoyancy upon which the thermal performance of the window depended.

  • PDF

A Study on the Pressure Loss Characteristics of Micro-Channel PCHE (마이크로 채널 PCHE의 압력손실 특성에 관한 연구)

  • Kim, Jin-Hyuck;Baek, Seung-Whan;Jeong, Sang-Kwon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.11
    • /
    • pp.751-759
    • /
    • 2010
  • A newly developed type PCHE(Printed Circuit Heat Exchanger), which has a longitudinal corrugation flow channel, was fabricated using etching and diffusion bonding to evaluate its hydraulic performance. The pressure drop characteristics obtained from the experimental results are presented and the local friction factors associated with different hydraulic diameters and inclination angles are discussed. The results of a three-dimensional numerical simulation are presented, conducted using commercial CFD(Computational Fluid Dynamics) software at lower Reynolds number range. The numerical results were validated by experimental data obtained from helium gas experimental apparatus. The results of CFD prediction show fairly good agreement with the experimental data.

Effects of Inner Jet Injection on Particle Deposition in the Annular Modified Chemical Vapor Deposition Process Using Concentric Tubes (환상형원관을 사용하는 수정된 화학증착(MCVD)방법에서 내부 제트분사가 입자부착에 미치는 영향)

  • 최만수;박경순
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.1
    • /
    • pp.212-222
    • /
    • 1994
  • In the annular Modified Chemical Vapor Deposition process using two concentric tubes, the inner tube is heated to maintain high temperature gradients to have high thermophoretic force which can increase particle deposition efficiency. However, higher axial velocity in a narrow gap between inner and outer tubes can result in a longer tapered entry length. In the present paper, a new concept using an annular jet from the inner tube is presented and shown to significantly reduce the tapered entry length with maintaining high efficiency. Effects of a jet injection on heat transfer, fluid flow and particle deposition have been studied. Of particular interests are the effects of jet velocity, jet location and temperature on the deposition efficiency and tapered length . Torch heating effects from both the previous and present passes are included and the effect of surface radiation between inner and outer tubes is also considered.

Skin Effect of Rotating Magnetic Fields in Liquid Bridge

  • Zhang, Yi;Zeng, Zhong;Yao, Liping;Yokota, Yuui;Kawazoe, Yoshi;Yoshikawa, Akira
    • Journal of Magnetics
    • /
    • v.22 no.2
    • /
    • pp.333-343
    • /
    • 2017
  • A rotating magnetic field (RMF) ${\Phi}_1-{\Phi}_2$ model was developed in consideration of the skin effect. The rotating magnetic field's induced three-dimensional flow was simulated numerically, and the influence of the skin effect was investigated. The rotating magnetic field drives the rotating convection in the azimuthal direction, and a secondary convection appears in the radial-meridional direction. The results indicate that ignoring the skin effect results in a smaller azimuthal velocity component and larger radial and axial velocity components, and that the deviation becomes more obvious with the larger dimensionless shielding parameter K.

A Numerical Analysis on the Airflow Characteristics in Super Cleanrooms with Different Design Types (초청정 클린룸 공조방식에 따른 기류특성에 관한 수치해석)

  • 노광철;이승철;오명도
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.9
    • /
    • pp.751-761
    • /
    • 2003
  • We performed the numerical analysis on the airflow characteristics in the two type of cleanroom systems, which are the axial fan type (AFT) and the fan filter unit (FFU). A computational fluid dynamic model was applied to investigate and compare the nonuniformity, the deflection angle and the air ventilation effectiveness of the two designs of cleanrooms when dampers are adjusted and not adjusted. And the flow-resistance models of the various components were used in this simulation. We know that the airflow characteristics of the cleanrooms are largely affected by damper adjusting And we also find out that the FFU system is superior to the AFT system through the comparison of the cleanroom performance indices.

Experimental and Analytical Investigation on Operating Characteristics for an Ejector Ramjet

  • Okai, Keiichi;Taguchi, Hideyuki;Futamura, Hisao
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.726-733
    • /
    • 2004
  • Experiments and numerical calculations were conducted on the flow field of a model ejector ramjet configuration to investigate fundamental fluid dynamic aspects of its pumping and mixing effects. Also a one-dimensional flight performance analysis program was constructed with a simple ejector modeling. After comparing the model with some of the previous experimental and numerical results, a flight performance analysis was conducted with the program. The present states of the program and some features to be improved are presented.

  • PDF

A Study on the Performance of Paper Heat Exchanger for Exhaust Heat Recovery (배기열 회수용 종이 열교환기의 성능에 관한 연구)

  • Yoo, Seong-Yeon;Chung, Min-Ho;Choi, Jae-Ho;Kwon, Hwa-Kil;Lee, Chun-Woo;Lee, Ki-Seong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.245-250
    • /
    • 2003
  • In order to control indoor air quality and save energy, it is needed to install a suitable ventilation system equipped with heat exchanger for heat recovery. The purpose of this research is to find the performance of paper heat exchanger for exhaust heat recovery, which exchanges latent heat as well as sensible heat. Experimental apparatus comprises heat exchanger model, constant temperature and humidity chamber, fan and measurement systems for temperature, pressure and flow rate. Thermal performance and pressure loss of the paper heat exchanger are measured and compared at various air velocities and outdoor conditions. Experimental results show that paper heat exchanger can recover $50{\sim}70%$ of the enthalpy difference between supply and exhaust air.

  • PDF

Thermohydrodynamic Bubbly Lubrication Analysis of High-Speed Journal Bearing (공기 혼합오일에 대한 고속 저어널 베어링 열유체 윤활 해석)

  • 전상명
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.06a
    • /
    • pp.201-211
    • /
    • 2001
  • The influence of aerated oil on high-speed journal bearing is examined by classical thermohydrodynamic lubrication theory coupled with analytical models for viscosity and density of aerated oil in fluid-film bearing. Convection to the walls, mixing with supply oil and re-circulating oil, and some degree of journal misalignment are considered. The considered Parameters for the study of bubbly lubrication are oil aeration level, air bubble size, shaft misalignment and shaft speed. The results show that deliberate oil aeration can more clearly bring on the increasing load capacity under high-speed operation of plain journal hearing than previous normal speed operation. And the load capacity may be increased more by oil aeration under the conditions of shaft misalignment and the increasing speed.

  • PDF