• Title/Summary/Keyword: fluence

Search Result 379, Processing Time 0.024 seconds

Characterization of saturation of CR-39 detector at high alpha-particle fluence

  • Ghazaly, M. El;Hassan, Nabil M.
    • Nuclear Engineering and Technology
    • /
    • v.50 no.3
    • /
    • pp.432-438
    • /
    • 2018
  • The occurrence of saturation in the CR-39 detector reduces and limits its detection dynamic range; nevertheless, this range could be extended using spectroscopic techniques and by measuring the net bulk rate of the saturated CR-39 detector surface. CR-39 detectors were irradiated by 1.5 MeV high alpha-particle fluence varying from $0.06{\times}10^8$ to $7.36{\times}10^8\;alphas/cm^2$ from Am-241 source; thereafter, they were etched in a 6.25N NaOH solution at a temperature of $70^{\circ}C$ for different durations. Net bulk etch rate measurement of the 1.5 MeV alpha-irradiated CR-39 detector surface revealed that rate increases with increasing etching time and reaches its maximum value at the end of the alpha-particle range. It is also correlated with the alpha-particle fluence. The measurements of UV-Visible (UV-Vis) absorbance at 500 and 600 nm reveal that the absorbance is linearly correlated with the fluence of alpha particles at the etching times of 2 and 4 hour. For extended etching times of 6, 10, and 14.5 hour, the absorbance is saturated for fluence values of $4.05{\times}10^8$, $5.30{\times}10^8$, and $7.36{\times}10^8\;alphas/cm^2$. These new methods pave the way to extend the dynamic range of polymer-based solid state nuclear track detectors (SSNTDs) in measurement of high fluence of heavy ions as well as in radiation dosimetry.

Evaluation of the Breast plan using the TLD and Mosfet for the skin dose (열형광선량계(TLD)와 MOSFET을 이용한 유방암 방사선치료계획에 대한 피부선량 평가)

  • Kim, seon myeong;Kim, young bum;Bak, sang yun;Lee, sang rok;Jeong, se young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.107-113
    • /
    • 2015
  • Purpose : The measurement of skin dose is very important that treatment of breast cancer. On account of the cold or hot dose as compared with prescription dose, it is necessary to analyse the skin dose occurring during the various plan of the breast cancer treatment. At our hospital, we want to apply various analyses using a diversity of dosimeters to the breast cancer treatment. Subjectss and Methods : In the study, the anthropomorphic phantom is used to find out the dose difference of the skin(draining site), scar and others occurring from the tangential treatment plan of breast cancer. We took computed tomography scan of the anthropomorphic phantom and made plans for the treatment planing using open and wedge, Field-in-Field, Dose fluence. Using these, we made a comparative analysis of the dose date points by using the Eclipse. For the dose comparison, we place the anthropomorphic phantom in the treatment room and compared the measurement results by using the TLD and MOSFET on the dose data points. Results : On the central point of treatment planing basis, the upward and downward skin dose measured by the MOSFET was the highest when the fluence was used. The skin dose of inner and outer was distinguished from the figure(5.7% ~ 10.3%) when the measurements were fulfilled by using TLD and MOSFET. The other side of breast dose was the lowest in the open beam, on the other hand, is highest in the Dose fluence plan. In the different kinds of treatment, the dose deviation of inner and outer was the highest, and so this was the same with the TLD and MOSFET measurement case. The outer deviation was highest in the TLD, and the Inner'was highest in the MOSFET. Conclusion : Skin dose in relation to the treatment plan was the highest in the planing using the fluence technique in general and it was supposed that the high dose had been caused by the movement of the MLC. There's some differences among the all the treatment planning, but the sites such as IM node occurring the lack of dose, scar, drain site are needed pay close attention. Using the treatment planning of dose fluence is good to compensate the lack of dose, but It increases the dose of the selective range rather than the overall dose. Therefore, choosing the radiotherapy technique is desirable in the lights of the age and performance of the patient.

  • PDF

Neutron Fluence Evaluation for Reactor Pressure Vessel Using 3D Discrete Ordinates Transport Code RAPTOR-M3G (3차원 수송계산 코드(RAPTOR-M3G)를 이용한 원자로 압력용기 중성자 조사량 평가)

  • Maeng, Young Jae;Lim, Mi Joung;Kim, Byoung Chul
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.10 no.1
    • /
    • pp.107-112
    • /
    • 2014
  • The Code of Federal Regulations, Title 10, Part 50, Appendix H requires surveillance program for reactor pressure vessel(RPV) that the peak neutron fluence at the end of the design life of the vessel will exceed $1.0E+17n/cm^2$ (E>1.0MeV). 2D/1D Synthesis method based on DORT 3.1 transport calculation code has been widely used to determine fast neutron(E>1.0MeV) fluence exposure to RPV in the beltline region. RAPTOR-M3G(RApid Parallel Transport Of Radiation-Multiple 3D Geometries) performing full 3D transport calculation was developed by Westinghouse and KRIST(Korea Reactor Integrity Surveillance Technology) and applied for the evaluations of In-Vessel and Ex-Vessel neutron dosimetry. The reaction rates from measurement and calculation were compared and the results show good agreements each other.

Study on the Fluence and LET Distribution of Projectile Fragments Produced from Heavy Ion Therapeutic Beams

  • Komori, Masataka;Fukumura, Akifumi;Hirai, Masaaki;Kanai, Tatuaki;Kohno, Ryosuke;Kohno, Toshiyuki;Matsufuji, Naruhiro;Nanbu, Syuya;Nishio, Teiji
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.216-218
    • /
    • 2002
  • Fluence and LET spectrum for 290,400 MeV/u $\^$12/C and 400 MeV/u $\^$20/Ne beams have been measured by a $\Delta$E-E counter telescope. Total charge-changing cross sections are deduced from measured fluence. The measured cross sections agree with previous measurements, however, they are disagreement with a model calculation. To dose-averaged LETs, the model calculation can reproduce the measured LETs except for peak LETs at Bragg peak region.

  • PDF

Numerical analysis of fs laser ablation of metals (금속의 펨토초 어블레이션의 수치해석)

  • Oh B.K.;Kim D.S.;Kim J.G.;Lee J.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.657-658
    • /
    • 2006
  • Although there are many numerical models to simulate fs laser ablation of metals, no model can analyze the ablation phenomena over a wide range of fluence. In this work, a numerical code for simulating the fs laser ablation phenomena of metals has been developed. The two temperature model is employed to predict the ablation rate and the crater shape of metals using phase explosion mechanism in the relatively high fluence regime. Also, the ultrashort thermoelastic model is used for the low fluence regime to account for spallation of the sample by high strain rate. It has been demonstrated that the thermoelastic stress generated within the sample can exceed the yield stress of the material even near the threshold fluence. Numerical computation results are compared with the experiment for Cu and Ni and show good agreement. Discussions are made on the hydrodynamic model considering phase change and hydrodynamic flow.

  • PDF

TSV Formation using Pico-second Laser and CDE (피코초 레이저 및 CDE를 이용한 TSV가공기술)

  • Shin, Dong-Sig;Suh, Jeong;Cho, Yong-Kwon;Lee, Nae-Eung
    • Laser Solutions
    • /
    • v.14 no.4
    • /
    • pp.14-20
    • /
    • 2011
  • The advantage of using lasers for through silicon via (TSV) drilling is that they allow higher flexibility during manufacturing because vacuums, lithography, and masks are not required; furthermore, the lasers can be applied to metal and dielectric layers other than silicon. However, conventional nanosecond lasers have disadvantages including that they can cause heat affection around the target area. In contrast, the use of a picosecond laser enables the precise generation of TSVs with a smaller heat affected zone. In this study, a comparison of the thermal and crystallographic defect around laser-drilled holes when using a picosecond laser beam with varing a fluence and repetition rate was conducted. Notably, the higher fluence and repetition rate picosecond laser process increased the experimentally recast layer, surface debris, and dislocation around the hole better than the high fluence and repetition rate. These findings suggest that even the picosecond laser has a heat accumulation effect under high fluence and short pulse interval conditions. To eliminate these defects under the high speed process, the CDE (chemical downstream etching) process was employed and it can prove the possibility to applicate to the TSV industry.

  • PDF

Transition of Femtosecond Laser Ablation Mechanism for Sodalime Glass Caused by Photoinduced Defects

  • Jeoung, Sae-Chae;Choi, Jun-Rye;Park, Myung-Il;Park, Mi-Ra;Choi, Dae-Sik
    • Journal of the Optical Society of Korea
    • /
    • v.7 no.3
    • /
    • pp.150-155
    • /
    • 2003
  • Femtosecond laser ablation mechanism was systematically investigated on sodalime glass in ambient conditions. The ablation crater diameter was measured for varying numbers of laser pulses as for varying well as the laser fluence. The analysis of the results with a one dimensional spatial Gaussian fluence distribution reveals that the inherent ablation mechanism has been altered from a multi-photon process to a single photon excitation due to defect sites that have been accumulated by successive laser pulses. Furthermore, the transition between the two regimes was found to be a function of both the laser fluence and the number of laser shots.

영광 원자력발전소 원자로 건물내 중성자 스펙트럼 측정

  • 손중권;신상운;조찬희
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.594-599
    • /
    • 1998
  • 출력 운전중 원자로 건물내의 중성자 에너지 스펙트럼의 분포를 살펴보기 위해 중성자 스펙트럼 측정을 수행하였다. 영광4흐기 원자로 건물내 100ft 상에서 4곳, 122ft 상에서 4곳, 144 ft 상에서 8곳을 Bonner Multisphere Spectrometer(BMS) 시스템을 이용하여 중성자 스펙트럼을 측정하였다. BMS는 Cf-252 선원으로 교정하였으며 측정된 데이터는 BUNKI 코드를 이용하여 unfolding 하여 에너지 스펙트럼을 얻었다 분석 결과 100 ft의 경우 평균 중성자 에너지는 0.100 ~ 1.954 MeV, Fluence는 4.913$\times$$10^2$ ~ 1.478$\times$$10^4$ n/$\textrm{cm}^2$, 선량율은 0.56 ~ 289.37 mrem/hr의 분포를, 122 ft의 경우 평균 중성자 에너지는 0.122 ~ 0.320 MeV, Fluence는 4.586$\times$$10^{0}$ ~ 7.743$\times$$10^3$ n$\textrm{cm}^2$, 선량율은 0.05 ~ 201.46 mrem/hr의 분포를, 144 ft의 경우 평균 중성자 에너지는 0.062 ~ 0.578 MeV, Fluence는 7.922$\times$$10^{0}$ ~ 1.703$\times$$10^2$ n/$\textrm{cm}^2$, 선량율은 0.10 ~ 45.58 mrem/hr의 분포를 보였다.

  • PDF

Polyimide Surface Modification using UV Laser (UV 레이저를 이용한 폴리이미드 표면 개질에 관한 연구)

  • Oh, Jae-Yong;Lee, Jung-Han;Park, Duk-Su;Shin, Bo-Sung
    • Laser Solutions
    • /
    • v.13 no.3
    • /
    • pp.13-18
    • /
    • 2010
  • In this paper, polyimide (PI) surface was modified by UV Laser with a low laser fluence and investigated changes of surface geometry and chemical characteristics by SEM (scanning electron microscope), X-ray diffraction (XRD), XPS (x-ray photoelectron spectroscopy) and the measurements of contact angle of water. PI surface was peeled off and modified with microstructure fabrications by photochemical ablation over the laser fluence of 50 mJ/cm2. As laser fluence increased, delamination of PI surface was occurred largely and strongly. In chemical characteristics, the O/C and N/C atomic ratios increased and contact angle decreased from $80^{\circ}$ to $40^{\circ}$.

  • PDF

Design of a New Capsule Controlling Neutron Flux and Fluence and Temperature of lest Specimen

  • Choo, Kee-Nam;Kang, Young-Hwan;Taiji Hoshiya;Motoji Niimi;Takashi Saito
    • Nuclear Engineering and Technology
    • /
    • v.29 no.2
    • /
    • pp.148-157
    • /
    • 1997
  • A new capsule that has a unique structure in which the test environments including neutron flux and fluence, and irradiation temperature can be controlled precisely during irradiation, was conceptually designed. The capsule structure and instrumentation were successfully designed according to the JMTR's standard procedures of capsule design. Based on the target irradiation, the details of the irradiation such as neutron fluence and irradiation temperature ore calculated and the related capsule safety was evaluated. In addition, the effects of design parameters including the changes in inner-capsule configuration, heater capacity, and Helium gas pressure on the specimen temperature were analyzed with a computer program. Through these thermal and strength evaluations, this capsule was proved to be safe during the irradiation in the JMTR.

  • PDF