• Title/Summary/Keyword: flow test

Search Result 6,521, Processing Time 0.04 seconds

포항 지열 개발지역에서의 지열 저류층에 대한 SP 모델링

  • ;;;Kasumi Yasukawa
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.417-421
    • /
    • 2004
  • Self-potential (SP) survey was carried out at Pohang geothermal field. SP measurement showed clear positive anomaly at northern part of the test wells, which can be a up-flow zone of the deep geothermal water due to electrokinetic potential generated by hydrothermal circulation. To give a clearer image of the fluid flow pattern around the test wells, a two-dimensional numerical simulation was applied to construct a numerical block model of the fluid flow system based on SP and magnetotelluric survey results. The result suggests existence of two high permeability zones including the main manifestation area in the northern part of the test wells.

  • PDF

Hydraulic Model Test and Numerical Analysis of Grass Concrete in River Environment (자연형 호안공법의 그라스콘의 수리모형실험 및 수치해석 연구)

  • Jang, Suk-Hwan;Park, Sung-Bum;Park, Sang-Woo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.1244-1248
    • /
    • 2007
  • This study aims at investigating the in situ applying grass concrete system in river environments which widely used nowadays and reviewing the effect and flow resistance for grass concrete structure through the physical experiments by hydraulic model test and developing application method in river bed which has rigid flood resistance. Grass concrete structure has been independently tested under high velocity flow under the super critical condition, as well as sud critical flow measuring velocity and water surface elevation along the cross section. This results shows grass concrete system is also suited to use in aggressive river environments such as repairing a flood damaged embankment that had placed at risk the adjacent drainage channel with vegetation.

  • PDF

An experimental study on the performance of a window system air-conditioner using R407C and R410B (R407C 및 R410B 적용 창문형 에어컨의 성능에 관한 실험적 연구)

  • Kim, M.H.;Shin, J.S.;Kim, K.J.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.4
    • /
    • pp.536-544
    • /
    • 1997
  • This study presents test results of a residential window system air-conditioner using R22 and two potential alternative refrigerants, R407C and R410B. A series of performance tests was performed for the basic and liquid-suction heat exchange cycle in a psychrometric calorimeter test facility. For R407C, the same rotary compressor was used as in the R22 system. However, compressor for the R410B system was modified to provide the similar cooling capacity. The evaporator circuit was changed to get a counter-cross flow heat exchanger to take advantage of zeotropic mixture's temperature glide, and liquid-line suction-line heat exchange cycle was also considered to improve the performance of the system. Test results were compared to those for the basic R22 system.

  • PDF

The Effect of Flow Induction Machine in Water Circulation System of Cheongna Canal Way (청라지구 물순환체계내 주운수로의 흐름유발시설 설치효과)

  • Kim, Dong-Eon;Choi, Gye-Woon;Park, Young-Sik;Yoon, Geun-Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.77-81
    • /
    • 2010
  • This study carried out hydraulic model test for water circulation system in Cheongna district as part of Incheon Free Economic Zone. Canal way project of Cheongna was planned to establish for environment-friendly water circulation system, improve quality of life and diversification of traffic through using boat as a water-friendly international business city. The navigation canal, There are two intake facility in central park and it can purify water 15,000$m^3$ per day. After purify, water move to 8 facility of water culture area which supplies water in canal way. This process called water circulation system in cheongna. Also, there are several flow induction machine in canal way except south-north way. Therefore, this study will verify about validity of water circulation system's safety through hydraulic model test.

  • PDF

Experimental and Analytical Researches on Mechanical Properties Related to Formability of AZ31B Alloy Sheet (AZ31B 합금판재 성형관련 기초물성 시험 및 해석 연구)

  • Kim, S.H.;Park, K.D.;Jang, J.H.;Kim, K.T.;Lee, H.W.;Lee, G.A.;Choi, S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.05a
    • /
    • pp.366-369
    • /
    • 2008
  • In this paper, tension tests and formability tests are performed to construct a database related to mechanical properties and the formability of the AZ31B Mg alloy sheet. A forming test with a hemi-spherical punch is conducted at varying temperatures to establish a forming limit diagram. In order to verify the applicability of the analysis using the conventional flow hardening model, a finite element analysis is performed on the hemi-spherical punch forming process and the results are compared with experimental ones. The study investigates problems involving a computational analysis that does not consider flow softening of the magnesium alloy at elevated temperatures.

  • PDF

Prediction of Aeroacoustics Noise of Pantograph via Low Speed Wind Tunnel Test and Flow Simulation (저속풍동실험 및 유동해석을 통한 고속전철 판토그라프의 유동소음 해석)

  • 조운기;이종수
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.1207-1214
    • /
    • 2001
  • The paper deals with the computational approach in analysis and design of pantograph panhead strips of high-speed railway in aerodynamic and aeroacoustic concerns. Pantograph is an equipment such that the electric power is supplied from catenary system to train. Due to the nature of complexity in high-speed fluid flow, turbulence and downstream vortices result in the instability in the aerodynamic contact between panhead strips and catenary system, and consequently generate the considerable levels of flow-induced sound. In this paper, based on the preceding low speed wind-tunnel test and simulations, the aerodynamic and aeroacoustic characteristics in low speed are analyzed.

  • PDF

Flow Dynamics in a Supersonic Diffuser at Minimum Starting Condition to Simulate Rocket's High Altitude Test on the Ground

  • Yeom, Hyo-Won;Yoon, Sang-Kyu;Sung, Hong-Gye;Kim, Yong-Wook;Oh, Seung-Hyup
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.442-447
    • /
    • 2008
  • A numerical analysis has been conducted to investigate and characterize the unsteadiness of flow structure and oscillatory vacuum pressure inside of a supersonic diffuser equipped to simulate the high-altitude rocket test on the ground. A physical model of concern includes a rocket motor, a vacuum chamber, and a diffuser, which have axisymmetric configurations, using nitrogen gas as a driving fluid. Emphasis is placed on investigating physical phenomena of very complex and oscillatory flow evolutions in the diffuser operating at very close to the starting condition, i.e. minimum starting condition, which is one of major important parameters in diffuser design points of view.

  • PDF

Comparison Study on Aerodynamic Performance and Wake Flow Field for a MW-Class Wind Turbine Model (대형 풍력터빈 모형의 공력 성능 및 후류 유동장에 대한 비교 연구)

  • Jeong, Duwon;Won, Young Soo;Kang, Seung-Hee
    • Journal of the Korean Society of Visualization
    • /
    • v.17 no.2
    • /
    • pp.32-38
    • /
    • 2019
  • A comparison study between computational-fluid-dynamics simulation and wind tunnel test for a megawatt-class wind turbine is conducted. For the study, flow-field in wake, basic aerodynamic performance, and effect of the yaw error for a 1/86 scaled-down model of the NREL offshore 5 MW wind turbine are numerically calculated using commercial software "FloEFD" with $k-{\varepsilon}$ turbulence model. The computed results are compared to the wind tunnel test performed by the constant-velocity mode for the model. It is shown that discrepancy are found between the two results at lower tip-speed ratio and higher yaw angle, however, the velocity-defection distribution in the wake, the torque coefficient at moderated and high tip-speed ratios are in good agreement with the wind tunnel test.

Numerical simulation of complex hexagonal structures to predict drop behavior under submerged and fluid flow conditions

  • Yoon, K.H.;Lee, H.S.;Oh, S.H.;Choi, C.R.
    • Nuclear Engineering and Technology
    • /
    • v.51 no.1
    • /
    • pp.31-44
    • /
    • 2019
  • This study simulated a control rod assembly (CRA), which is a part of reactor shutdown systems, in immersed and fluid flow conditions. The CRA was inserted into the reactor core within a predetermined time limit under normal and abnormal operating conditions, and the CRA (which consists of complex geometric shapes) drop behavior is numerically modeled for simulation. A full-scale prototype CRA drop test is established under room temperature and water-fluid conditions for verification and validation. This paper describes the details of the numerical modeling and analysis results of the several conditions. Results from the developed numerical simulation code are compared with the test results to verify the numerical model and developed computer code. The developed code is in very good agreement with the test results and this numerical analysis model and method may replace the experimental and CFD method to predict the drop behavior of CRA.

Durability Assessment by Structural and Fatigue Analysis of Flow Control Valves (FCVs) for Hydrogen Refueling Stations (수소 충전소용 유량제어밸브(FCV)의 구조 및 피로해석을 통한 내구 성능 평가)

  • CHOI, INHO;HA, TAE IL;KIM, HAN SANG
    • Journal of Hydrogen and New Energy
    • /
    • v.33 no.3
    • /
    • pp.240-246
    • /
    • 2022
  • This study was conducted to develop a domestic product for a flow control valve for a hydrogen refueling station, and a domestic prototype was manufactured and the durability performance evaluation was conducted through comparison with an imported products. The stress generated by the internal pressure was checked and safety was confirmed using a commercial structural analysis program, ABAQUS, in accordance with the withstand pressure test standards. In addition, after identifying the weak areas the fatigue life was predicted through a commercial software, fe-safe. This fatigue analysis showed that the hydrogen gas repeated test criteria were satisfied.