• Title/Summary/Keyword: flow front and void

Search Result 18, Processing Time 0.02 seconds

Visualization of cross-sectional two-phase flow structure during in-tube condensation (관내 응축 시 2상유동 단면구조의 가시화)

  • Pusey, Andree;Kim, Hyungdae
    • Journal of the Korean Society of Visualization
    • /
    • v.14 no.2
    • /
    • pp.18-24
    • /
    • 2016
  • This paper presents an experimental investigation to visualize cross-sectional two-phase flow structure and identify liquid-gas interface for condensation of steam at a low mass flux in a slightly inclined tube using the axial-viewing technique, which permits to look directly into flow during condensation of steam. In this technique, two-phase flow is viewed along the axis of a pipe by locating a high-speed video camera in front of a viewer that is fitted at the outlet of the pipe. A short section of the pipe is illuminated and is recorded through the viewer, which is kept free of liquid by mildly introducing air. Experiments were conducted in a pipe of 19.05 mm in inner diameter at atmospheric pressure. Cross-sectional two-phase flow structure is obtained at a steam mass flux of $2.62kg/m^2s$ as a function of steam quality in the range from 0.5 to 0.9. The results show that stratified-wavy flow is a unique flow pattern observed in the scope of the present study. Condensate film thickness, stratification angle and void fraction were measured from the obtained flow structure images. Finally, heat transfer coefficient was calculated using the measurement data and discussed in comparison with existing correlations.

A Study on the Adaptive Reuse Techniques through the History of Buildings in the Historic Urban Area - Focused on the Deep and Narrow Lots of Nammun-ro 2Ga, Cheongju - (역사적 도심 내 건축물의 이력을 통해 본 재생기법에 관한 연구 -청주시 남문로 2가동의 세장형 필지를 대상으로-)

  • Kim, Tai-Young
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.22 no.2
    • /
    • pp.1-8
    • /
    • 2020
  • This study is intended to derive the adaptive reuse techniques through the history and aspects of new construction, extension, repair, and other works, limited to the deep and narrow lots facing Seongan-gil and Nammun-gil in Nammun-ro 2 ga of Cheongju, the historic urban area. The results are as follows. 1) In the case of newly built reinforced concrete buildings, the central part of the top floor of the residence or all floors are opened to the open space(void) to facilitate lighting and ventilation. This is developed as a convection phenomenon due to the temperature difference from the slits between buildings, which affects the entire air flow of the block. 2) The buildings of extension and repair are composed of two-story masonry or steel frame, both the front store facing the road and the house on the back, but it looks like one because it is in contact with each other. If only a small gap between the front and rear buildings is restored to an external space or a space equipped with sun light, a small breath can be provided in lighting and ventilation. 3) The existing two-story wooden stores and houses have lost their external space due to repairs. With minimal intervention to restore the small courtyard, slits, and space under the eaves, it will not only improve lighting and ventilation, but also create a unique appearance as a segment of the elongated store.

MEASUREMENT OF THE SINGLE AND TWO PHASE FLOW USING A NEWLY DEVELOPED AVERAGE BIDIRECTIONAL FLOW TUBE

  • Yun, Byong-Jo;Euh, Dong-Jin;Kang, Kyunc-Ho;Song, Chul-Hwa;Baek, Won-Pil
    • Nuclear Engineering and Technology
    • /
    • v.37 no.6
    • /
    • pp.595-604
    • /
    • 2005
  • A new instrument, an average BDFT (Birectional Flow Tube), was proposed to measure the flow rate in single and two phase flows. Its working principle is similar to that of the Pilot tube, wherein the dynamic pressure is measured. In an average BDFT, the pressure measured at the front of the flow tube is equal to the total pressure, while that measured at the rear tube is slightly less than the static pressure of the flow field due to the suction effect downstream. The proposed instrument was tested in air/water vertical and horizontal test sections with an inner diameter of 0.08m. The tests were performed primarily in single phase water and air flow conditions to obtain the amplification factor(k) of the flow tube in the vertical and horizontal test sections. Tests were also performed in air/water vertical two phase flow conditions in which the flow regimes were bubbly, slug, and churn turbulent flows. In order to calculate the phasic mass flow rates from the measured differential pressure, the Chexal drift-flux correlation and a momentum exchange factor between the two phases were introduced. The test results show that the proposed instrument with a combination of the measured void fraction, Chexal drift-flux correlation, and Bosio & Malnes' momentum exchange model could predict the phasic mass flow rates within a $15\%$ error. A new momentum exchange model was also proposed from the present data and its implementation provides a $5\%$ improvement to the measured mass flow rate when compared to that with the Bosio & Malnes' model.

A Study on the Control Strategy to Minimize Voids in Resin Transfer Mold Filling Process (RTM 공정에서 기공 최소화를 위한 공정 제어에 관한 연구)

  • Lee Doh Hoon;Jeon Young Jae;Lee Woo Il;Um Moo Kwang;Byun Joon Hyung
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2004.04a
    • /
    • pp.292-296
    • /
    • 2004
  • In case of Resin Transfer Molding(RTM) process, 'race-track' effects and non-uniform fiber volume fraction may cause undesirable resin flow pattern and thus result in dry spots, which affect the mechanical properties of the finished parts. In this study, a real time RTM control strategy to prevent these unfavorable effects is proposed. The control strategy consists of two 'stages' depending on the extent the resin front has reached. Through numerical simulations and experiments, the validity of the proposed scheme is demonstrated. The results show that the proposed scheme is effective in reducing the void formation during RTM mold filling.

  • PDF

Full Three Dimensional Rheokinetic Modeling of Mold Flow in Thin Package using Modified Parallel Plate Rheometry (개선된 회전형 레올로지 측정법을 이용한 박형 반도체 패키지 내에서의 3차원 몰드 유동현상 연구)

  • LEE Min Woo;YOO Min;YOO HeeYoul
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2003.11a
    • /
    • pp.17-20
    • /
    • 2003
  • The EMC's rheological effects on molding process are evaluated in this study. When considering mold processing for IC packages, the major concerning items in current studies are incomplete fill, severe wire sweeping and paddle shifts etc. To simulate EMC's fast curing rheokinetics with 3D mold flow behavior, one should select appropriate rheometry which characterize each EMC's rheological motion and finding empirical parameters for numerical analysis current studies present the new rheometry with parallel plate rheometry for reactive rheokinetic experiments, the experiment and numerical analysis is done with the commercial higher filler loaded EMC for the case of Thin Quad Plant Packages (TQFP) with package thickness below 1.0 mm. The experimental results and simulation results based on new rheometry matches well in point of the prediction of wire sweep, filling behavior of melt front advancement and void trapping position.

  • PDF

Artifacts due to Retrograde Flow in the Artery and Their Elimination in 2D TOF MR Angiography (2D TOF 자기공명 혈관조영술에서 동맥혈류의 역류로 인한 영상훼손과 이의 제거)

  • Jung, K.J.;Lee, J.K.;Kim, S.K.;Park, S.H.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.1
    • /
    • pp.38-42
    • /
    • 2001
  • Dark band artifacts are often observed in angiograms of arteries obtained by 2D time-of-flight (TOF) angiography with saturation of veins by presaturation RF pulses. At some arteries the arterial blood velocity varies in a triphasic pattern during a cardiac cycle. The arterial blood, that is saturated by presaturation RF pulses in the saturation band, can flow back into the imaging slice during the retrograde flow phase of the triphasic variation. When such saturated retrograde flow occurs during the acquisition of the central part of the K space, a signal void can result in base images and consequently dark band artifacts can appear in angiograms. This phenomenon is experimentally demonstrated by varying the gap between the imaging slice and the saturation band. Furthermore, a new pulse sequence is proposed to eliminate the dark band artifacts by changing the profile of the saturation band front a rectangle to a ramp.

  • PDF

An Analysis of Mario Botta's residential design (Mario Botta 주거 건축의 특성 분석)

  • 조희라
    • Journal of the Korean housing association
    • /
    • v.12 no.4
    • /
    • pp.195-203
    • /
    • 2001
  • The purpose of this study is to analyze the characteristics of Mario Botta's residential design. The characteristics of Mario Botta's residential design are following as : 1. The residential design of Mario Botta planed from 1960' to 1970's is based on the style composition method of modern design, specially by the influence of Le Corbusier and Louis I. Kahn. Botta's residential design of the 1980's is generally affected by A. Palladio, and is characterized as the representation of classic standard. The residential design of the 1980's shows the establishment level of Mario Botta's residential design, and produces particular Botta's facade. 2. The characteristics of Mario Botta's spatial composition on residential design could be implicated by the spatial distribution of each floor which is divided by three floors, simple and primitive volume which has a symmetry, opening through the massive elimination n the center of front, double skin, the contrast between void and solid, and the inflow of light through the top-light. 3. Most Botta's residential designs have Loggia in the center of facade working as a buffer space which joins outside and inside space together. They also lead the spatial continuous flow. The inside space is combined by the light coming through top-light and vertical opening. 4. They have high accomplishment in complicating details. They show the outside design of a horizontal belt according to the module of concrete block and the decorated design using compositional materials such as an unevenness piled up askew concrete block .

  • PDF

Three-Dimensional Numerical Simulation of Mold-Filing and Void Formation During Vacuum-Assisted Resin Transfer Molding (VARTM 공정에서의 금형 충전 및 기공 형성에 관한 3차원 수치해석)

  • 강문구;배준호;이우일
    • Composites Research
    • /
    • v.17 no.3
    • /
    • pp.1-7
    • /
    • 2004
  • In the vacuum assisted RTM (VARTM) process that has become the center of attention for manufacturing massive composite structures, a good evacuation of air in the fiber preform is recognized as the prime factor. The microvoids, or the dry spots, are formed as a result of improper gate/vent locations and the mold geometry. The non-uniform resin velocity at the flow front leads to the formation of microvoids in the fibers, whereas the air in the microvoids can migrate along with the resin flow during mold filling. The residual air in the internal voids of a composite structure may cause a degradation of the mechanical properties as well as the structural failure. In this study, a unified macro- and micro analysis methods were developed to investigate the formation and transport of air in resin during VARTM process. A numerical simulation program was developed to analyze the three-dimensional flow pattern as well as the macro- and microscopic distribution of air in a composite part fabricated by VARTM process.