• 제목/요약/키워드: flow dependency

검색결과 195건 처리시간 0.033초

부력을 최소화한 대향류 삼축 메탄-공기 비예혼합 화염 소화에서 에지화염의 거동 (Behavior of the Edge Flame on Flame Extinction in Buoyancy minimized Methane-Air Non-premixed Counter Triple Co-flow Flames)

  • 박진욱;박정;윤진한;길상인
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2014년도 제49회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.81-84
    • /
    • 2014
  • A Experimental study on flame extinction behavior was investigated using He curtain flow with counter triple co-flow burner. Buoyancy force was suppressed up to a microgravity level of $10^{-2}-10^{-3}g$ by using He curtain flow. The stability maps were provided with a functional dependency of diluent mole fraction and global strain rate to clarify the differences in flame extinction behavior. The flame extinction curves had C-shapes at various global strain rates. The oscillation and extinction modes were different each other in terms of the global strain rate, and the flames extinction modes could be classified into five modes such as (I) and (II): an extinction through the shrinkage of the outmost edge flame forward the flame center after self-excitation and without self-excitation, respectively, (III): an extinction through rapid advancement of a flame hole while the outmost edge flame is stationary, (IV): self-excitation occurs in the outermost edge flame and the center edge flame and then a donut shaped flame is formed and/or the flame is entirely extinguished, (V): shrinkage of the outermost edge flame without self-excitation followed by shrinkage or survival of the center flame. These oscillation and extinction modes could be identified well to the behavior of edge flame. The result also showed that the edge flame was influenced significantly by the conductive heat losses to the flame center or ambient He curtain flow.

  • PDF

Viscous Flow Behavior of (90-x)SiO2-xNa2O-10RO (x = 15-40) Glasses with Low Sintering Temperature

  • Lee, Hansol;Park, Hyun-A;Kim, Hyeong-Jun;Chung, Woon Jin
    • 한국세라믹학회지
    • /
    • 제56권2호
    • /
    • pp.167-172
    • /
    • 2019
  • Silicate glasses with varying SiO2 and Na2O contents were prepared and their viscous flow property at the elevated temperature was studied. When the glass powders were packed and sintered at 550℃ to examine their feasibility as a low sintering temperature glass frit, contrary to expectations, glasses with lower SiO2 content than 60 mol% showed no vitrification after sintering. High temperature microscopy revealed the viscous flow change of the silicate glasses with varying temperature and duration time and also indicated that the viscous flow was limited at low SiO2 content. X-ray diffraction (XRD) on the sintered samples and Raman spectroscopy were carried out to shed light on the compositional dependency of viscous flow of silicate glasses.

대형 와 모사를 사용한 혼합 탱크 내의 농도장과 유동장의 동시 해석 (Simultaneous Analysis of Concentration and Flow Fields in A Stirred Tank Using Large Eddy Simulation)

  • 윤현식;전호환;하만영
    • 대한기계학회논문집B
    • /
    • 제27권9호
    • /
    • pp.1282-1289
    • /
    • 2003
  • Transport of a scalar quantity, such as chemical concentration or temperature, is important in many engineering applications and environmental flows. Here we report on results obtained from the large eddy simulations of flow and concentration fields inside the tank performed using a spectral multi-domain technique. The computations were driven by specifying the impeller-induced flow at the blade tip radius (Yoon et al.). This study focused on the concentration development at different molecular diffusivities in a stirred tank operated under turbulent conditions. The main objective of the work presented here is to study the large-scale mixing structure at different molecular diffusivities in a stirred tank by using the large eddy simulation. The time sequence of concentration and flow fields shows the flow dependency of the concentration development. The presence of spatial inhomogenieties is detailed by observing the time variation oflocal concentration at different positions.

초전도케이블 냉각유로의 열 및 유동 특성 해석 (The thermal & hydraulic analysis of the cooling passage for HTS power cable)

  • 홍용주;염한길;김효봉;고득용
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.167-170
    • /
    • 2003
  • The thermal and hydraulic characteristics of the cooling passage for HTS power cable should be carefully investigated to get the highly reliable and economic operation. In this study, the pressure drop and temperature change of the coolant flowing the corrugated passage was estimated using the simple one-dimensional approach, and the temperature distribution in the radial direction was calculated. The results show the dependency of the mass flow rate, thermal conductivities on the cooling performance of the HTS cable.

  • PDF

2상류용 전류형식 전자기유량계 이론 및 환상류에서의 3차원 가상포텐셜 분포의 수치적 계산 (Theory of a Current-Type Electromagnetic Flowmeter for Two-Phase Flow and Numerical Computation of the 3D Virtual Potential Distributions for Annular Flow)

  • 오병도;김무환;안예찬
    • 대한기계학회논문집B
    • /
    • 제27권6호
    • /
    • pp.714-725
    • /
    • 2003
  • The theory of the current-type electromagnetic flowmeter for a high temporal resolution was developed for two-phase flow measurements. To predict the output of the current-type flowmeter, the three-dimensional virtual potential distribution C and the newly introduced flow pattern coefficient f were derived and computed. The output of flowmeter depends on the liquid conductivity (sensitive to temperature) and flow configurations of the two-phase flow with the sinusoidal excitation over 100 Hz. The flow pattern coefficient was specially devised to separate the dependency on the flow configuration of the two-phase flow from that on the liquid conductivity which can be expressed with the calibration of single-phase flow. Using the finite difference method, the three-dimensional virtual potential distributions were computed for the electrode of finite size. By taking derivative of the virtual potential, the weight functions were evaluated and compared with existing analytic series solution for the point-electrode. There was a reasonable correspondence between the present and existing results. In addition, the flow pattern coefficients were evaluated for annular flows with various film thicknesses, and compared with the experimental results by the impedance spectroscopy. The numerical results agreed well with the experimental data.

스월형 분사기 분무 예측 모델에서의 격자 의존성 연구 (Study of Grid Dependency of Sheet Atomization Model of a Pressure-Swirl Atomizer)

  • 문윤완;설우석;윤영빈
    • 대한기계학회논문집B
    • /
    • 제34권9호
    • /
    • pp.817-824
    • /
    • 2010
  • 본 연구에서는 개선된 액막 분열 모델을 개발하였고 그에 따른 계산격자 의존성을 고찰하였다. 액막 및 액적 추적을 위해 라그랑지-오일러 액적 추적 모델을 사용하였기 때문에 계산격자의 크기에 한계가 있으므로 매우 작은 격자를 사용하는데 제약을 받는다. 또한 유동장내로의 분사기의 액막 주입 시선회유동이 존재하므로 선회 유동을 정확히 예측하기 위해서는 계산격자가 충분히 작아야 한다. 이러한 상반된 조건으로부터 두 목적을 달성하기 위해 10$\times$10mm부터 0.625$\times$0.625mm까지 다양한 계산격자를 구성하여 수치적 고찰을 수행하였고 가장 효율적인 격자의 크기는 1.25$\times$1.25mm인 것을 알 수 있었다.

Ideograph를 이용한 최적화 및 병렬성 정보 표현에 관한 연구 (A Study on the Optimization and Parallelism Information Representation using Ideograph)

  • 정성옥;고광만
    • 지능정보연구
    • /
    • 제6권2호
    • /
    • pp.41-47
    • /
    • 2000
  • 최적화란 비효율적인 코드를 구분해 내서 실행 속도 및 기억 공간의 효율성을 높여 주는 방법으로 컴파일러의 각 단계에서 수행된다. Augustus K. Uht에 의해 제안된 Ideograph는 입력 프로그램에 대한 제어 의존성과 자료 의존성에 관한 정보를 동시에 표현할 수 있어 코드 최적화 단계에서 효과 적으로 이용될 수 있으며 프로그램에 존재하는 병렬성을 표현하는데 효과적이다. 구문 트리는 원시 프로그램을 정보를 효율적으로 표현할 수 있는 중간 표현으로서 컴파일러 구 현에 널리 사용되고 있다. 본 논문에서는 원시 프로그램의 중간 표현이 구문 트리를 입력으로 받아 최적화 정보를 추출한 후 제어 흐름 및 자료 흐름 분석 정보를 추출하여 제어 의존성과 자료 의 존성을 Ideograph에 동시에 표현한다.

  • PDF

Effect of 2-Methylaminoethyl-4,4'-Dimethoxy-5, 6, 5' ,6'-Dimethyl­enedioxybiphenyl-2-Carboxylic Acid-2'-Carboxylate Monohydro­chloride (DDB-S) on Indocyanine Green (ICG) Clearance in Rats

  • Lee Kyoung-Jin;Kim Jae-Ryung;Lee Chi-Ho
    • Archives of Pharmacal Research
    • /
    • 제28권1호
    • /
    • pp.115-119
    • /
    • 2005
  • The clearance of ICG, a known hepatic blood flow marker was investigated in rats in order to examine whether DDB-S influences hepatic blood flow. The effect of DDB-S on the protein binding and blood-to-plasma partition of ICG was measured. The steady-state plasma concentration of ICG was monitored before and after co-administration of various concentration of DDB-S, and ICG clearance was estimated from the steady-state concentration and the infusion rate of ICG. There was no significant difference in protein binding and blood-to-plasma partition of ICG with and without addition of DDB-S (10, 20, and 40 ${\mu}g/mL)$. When ICG was infused into DDB-S pretreated rats, the steady-state concentrations of ICG decreased and the calculated ICG clearance increased. However, no dose-dependency of ICG Css on DDB-S Css was observed. Since DDB-S did not affect the protein binding and blood-to-plasma partition of ICG, the increased clearance of ICG with co-administration of DDB-S seems to be due to the increased hepatic blood flow by DDB-S.

유입부 형상이 저전압 전동기 냉각홴의 공력성능에 미치는 영향 (Effects of Inlet Vent Shape on Aerodynamic Performance of a Low-Voltage Electric Motor Cooling Fan)

  • 박재민;허만웅;김광용
    • 한국유체기계학회 논문집
    • /
    • 제19권5호
    • /
    • pp.42-49
    • /
    • 2016
  • Aerodynamic analysis of a low-voltage electric motor has been performed with various inlet vent shapes. Effects of inlet vent shape on aerodynamic performance of a motor cooling fan have been investigated numerically using three-dimensional Reynolds-averaged Navier-Stokes equations. The k-${\varepsilon}$ turbulence model was used for the analysis of turbulence. The finite volume method and unstructured tetrahedral grids were used in the numerical analysis. Optimal grid system in the computational domain was selected through a grid-dependency test. From the results of the flow analysis, considerable energy loss by flow separation was observed in the flow passage. It was found that mass flow rate through the cooling fan in the low-voltage motor can be increased by modifying the inlet vent shape. And, some inlet vent shapes were suggested to improve the aerodynamic performance of the motor cooling fan.

초음파를 이용한 기체 유동장내 분진 모니터링 (Particle Monitoring Using Ultrasound in the Gas Flow)

  • 장경영;김주철;김홍준;황원호
    • 한국정밀공학회지
    • /
    • 제21권10호
    • /
    • pp.78-85
    • /
    • 2004
  • The particle amount monitoring technique using ultrasound is proposed to determine the proper maintenance time of the filter in the supply process of pure gas in the unit of oxygen plant. There are advantages that it is adaptable in high temperature and high pressure, and it is not disturbed by being exposed in the gas flow, and it can be implemented very economically. The applicability of the ultrasonic technique is pre-studied through the theoretical analysis for the dependency of attenuation of ultrasonic wave on the particles in the gas flow. For the purpose, absorption, scattering and dispersion models are considered, and the attenuation by absorption and the change rate of the propagation speed are calculated fur the specific range of particle size and the ultrasonic wave frequency. It was expected by simulation that the absorptive attenuation by particles was the most sensitive to the change of particle amount. The experimental result showed high correspondence with the theoretical expectation so that this ultrasound attenuation measurement was proved to be highly effective for monitoring the amount of floating particles in the gas flow.