• Title/Summary/Keyword: flow capacity test

Search Result 342, Processing Time 0.029 seconds

RELATIONSHIP BETWEEN SALIVARY CARIES-RELATED TESTS AND DENIAL CARIES EXPERIENCE IN KOREAN DENTAL COLLEGE STUDENTS (타액 우식 관련 검사와 치아 우식 경험과의 관계에 관한 연구)

  • Kim, Jae-Gon;Kim, Young-Shin;Baik, Byeong-Ju;Yang, Yeon-Mi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.1
    • /
    • pp.67-74
    • /
    • 2005
  • The aim of this study was to analyze the relationship between salivary flow, salivary buffer capacity, level of mutans streptococci and dental caries experience in Korean dental college students. A total of 81 students of the school of dentistry, Chonbuk national university, mean age of 26.1 years, were subjected to oral examination to establish the DMFT and DMFS according to WHO guidelines. Saliva samples from the students were collected for quantitating stimulated and unstimulated salivary flow rate. Buffering capacity was estimated using a commercial colorimetric strip test, and number of mutans streptococci was determined from stimulated saliva using a strip mutans test. The means of DMFT and DMFS were 6.57 and 12.65, respectively. The stimulated salivary flow rate was correlated with DMFT(${\acute{o}}\;=\;-0.219$) and high levels of salivary mutans streptococci were significantly correlated with higher DMFT and DMFS scores(P<0.05). Level of mutans streptococci was significantly correlated with dental caries experience, in both DMFT and DMFS score, and buffering capacity was inversely correlated to DMFT score. However, unstimulated salivary flow rate was not correlated with caries experience.

  • PDF

A Study on the Performance of HCFC22 and Alternative Refrigerants in Heat Pumps (열펌프를 이용한 R22대체 혼합냉매의 성능에 관한 연구)

  • Song, Y.J.;Jung, D.G.
    • Solar Energy
    • /
    • v.18 no.1
    • /
    • pp.69-79
    • /
    • 1998
  • This paper is concerned about the performance of HCFC22 alternative refrigerants used in heat pumps and industrial chillers. A water-to-water breadboard heat pump with counter-current heat exchangers and a hermetic compressor was built to carry out the experiments with various refrigerants. For each test, more than 40 temperatures, 4 pressures, power input, mass flow rates of the heat transfer fluids were measured. Refrigerants tested were HCFC22, R290(Propane), an azeotrope of 45%Propane/55%R134a mixture, and a nonazeotropic mixture of Calor 50. All tests were conducted under ARI test A condition. It is found that the COP and capacity of propane were 18% and 2.5% higher than those of HCFC22 while the COP and capacity of 45%Propane/55%R134a mixture were 3.5% and 5.3% higher than those of HCFC22 respectively. Also the COP and capacity of Calor 50 were 17% and 7.8% higher than those of HCFC22. Compressor discharge temperatures of alternative refrigerants were roughly $35^{\circ}C$ lower than that of HCFC22 indicating that these refrigerants are good from the view point of compressor reliability. The charging amounts for the alternative refrigerants were reduced by 40-60% as compared to that of HCFC22. Overall, it can be said that hydrocarbon containing alternative refrigerants are excellent in thermodynamic performance but should be used with considerable care due to their flammability.

  • PDF

Comparison of The Effects of Respiratory Exercise between Smokers and Non-smokers on Pulmonary Function and Muscle Activity of Rectus Abdominis with The Elderly People

  • Jun, Hyun Ju;Kim, Ki Jong
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.8 no.2
    • /
    • pp.1146-1151
    • /
    • 2017
  • The purpose of this study was to compare the effects of respiratory exercise on cardiopulmonary function and muscle activity of rectus abdominis in smokers and non-smokers with elderly people. All the participants were older than 65 years, and twenty non-smokers, and twenty smokers participated. Non-smokers and smokers were randomly divined into 10 feedback breathing exercises (FBE) and a balloon-blowing exercise (BBE) group. The FBE and the BBE were performed three times a week for four weeks. Forced vital capacity (FVC), forced expiratory volume at one second (FEV1), forced expiratory volume at one second/forced vital capacity (FEV1/FVC), peak expiratory flow (PEF), and vital capacity (VC) were measured as pulmonary function. EMG was used to measure the activity of the rectus abdominis. In the FBE and BBE groups, $FEV_1$ was significantly lower in non-smokers compared to smokers at two and four weeks (p<.05), $FEV_1/FVC$, PEF and VC were significantly lower in non-smokers compared to smokers to pre-test, two weeks, four weeks and six weeks (p<.05). Muscle activity of rectus abdominis was significantly difference in the BBE group at pre-test, two weeks, four weeks, and six weeks (p<.05). These results suggest that respiratory exercise was effective in improving pulmonary function and rectus muscle activity.

A Study on the Behavior of Deformation in Soft Soils Subjected to Lateral Flow (측방유동을 받는 연약지반의 변형거동에 관한 연구)

  • 안종필;홍원표
    • Geotechnical Engineering
    • /
    • v.10 no.2
    • /
    • pp.25-40
    • /
    • 1994
  • In order to investigate behavior of lateral flow by plasticity of soils and construction control due to it, in the case of unsymmetrical surcharge load on the soft soils, we examine the existing theoretical background, and compared and analysed the experimental results by model test. After model test fabricated by model test apparatus, which made full remolding samples of soft soils, we observed the state of behavior for deformation with increasing load step to constant time interval. The critical surcharge and ultimate capacity showed tendency to approach to the proposed value of Jaky and Meyerhof, and the lateral flow pressure of which the maximum value was acted on the depth calculated by z/H=0.26+1.71cu and one third value of the maximum lateral flow pressure acted on the ground surface, approach the trapezoid distribution And maximum lateral flow pressure will be calculated by proposed equation of Hong or simple equation which($\alpha=0.4$) the flow pressure coefficient . of proposed equation by Tschebotarioff exchanged to($\alpha=K_0$) . Basides, the failure surcharge by [(q/$y_m$)-q] and [$S_y-(y_m/S_y)$] showed the smaller than ultimate bearing capacity, especially failure criteria line of control diagram of [$S_y(y_m/S_y)$] will be calculated by following equation. $S_y.=3.15exp[-0.58(y_m/S_y)$

  • PDF

Analysis of 3D Facial dimensions and Pulmonary Capacity of Korean Children for Designing of Children's Dust Masks (어린이 보건용 마스크의 인증기준 마련을 위한 3D 얼굴치수 및 호흡량 연구)

  • Seo, Hyekyung;Kim, Jennifer Ivy;Yoon, Jong-Seo;Shin, Donghoon;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.4
    • /
    • pp.269-282
    • /
    • 2017
  • Objectives: Currently, masks against yellow dust and fine particulates are being certified with no consideration of facial dimensional variations among children and adults. The aims of this study were to develop masks against yellow dust and fine particulates for children in Korea and provide basic data to suggest new test methods for mask certification that consider the breathing capacity of children. Methods: A total of 730 study participants aged from six to 13 years old were recruited in the Seoul, Gyeonggi, and Incheon region. This study used a 3D scanning instrument to obtain 16 facial anthropometric data points. Literature reviews, a comparison of breathing capacity between adults and children, and analysis of children's pulmonary physiological data were conducted in order to suggest new test standards for certifying children's masks against yellow dust and fine particulates. In addition, types of children's masks, choice of wearing a mask or not, and reasons for not wearing masks were surveyed. Results: Based on a clustering analysis of participants' facial dimensions, facial shapes were classified into three groups: small, medium, and large. The sizes of children's masks were subtracted by using 3D sketch techniques(Large: $121.25mm{\times}89.46mm$, Medium: $111.92mm{\times}78.55mm$, Small: $102.13mm{\times}72.87mm$). In certifying children's mask, flow rates of $60{\ell}/m$ for the filtering efficiency test and $20{\ell}/m$ for the breathing resistance test were recommended, since children's pulmonary physiological capacity is about 60-70% of adults' pulmonary capacity. Conclusions: The results of this study suggest that three mask sizes for children would be sufficient and practical for providing protection against yellow dust and fine particulates. Revising current test methods for certifying respiratory protective devices for children is important, since children's pulmonary physiological capacity substantially differs from that of adults. Therefore, it is recommended that new test standards for certifying children's masks be promulgated in the near future.

Study on Crashworthiness of Icebreaker Steel: Part I Steel Properties (쇄빙선 강재의 내충격 특성에 관한 실험적 연구: 제1부 강재 특성)

  • Noh, Myung-Hyun;Lee, Jae-Yik;Park, Sung-Ju;Choung, Joonmo
    • Journal of Ocean Engineering and Technology
    • /
    • v.30 no.4
    • /
    • pp.268-276
    • /
    • 2016
  • This paper presents a study on the crashworthiness of the scaled-down stiffened panels used on a Korean icebreaker. In order to validate the crashworthiness of the panels, this paper provides various mechanical properties such as the results of a CVN test, quasi-static tensile test, and high-speed tensile test at arctic temperatures. Two types of steels (EH32 and FH32) were chosen for the material tests. CVN tests revealed that the two steels were equivalent up to −60℃ in terms of their impact energy absorption capacity. However, the toughness of FH32 was significantly superior to that of EH32. EH32 showed slightly higher flow stresses at all temperature levels compared to FH32. The improvement ratios of the yield strengths, tensile strengths, plastic hardening exponents, etc. for FH32, which were obtained from quasi-static tensile tests, showed an apparent ascending tendency with a decrease in temperature. Dynamic tensile test results were obtained for the two temperatures levels of 20℃ and −60℃ with two plastic strain rate levels of 1 s−1 and 100 s−1. A closed form empirical formula proposed by Choung et al. (2011;2013) was shown to be effective at predicting the flow stress increase due to a strain rate increase.

Discharge Capacity for Vertical Drain Boards with Hydraulic Gradient Variation (동수경사 변화에 따른 연직배수재의 통수능)

  • Kim, Ju-Hyong;Lee, Kwang-Wu;Cho, Sam-Deok;Chang, Gap-Shik
    • Journal of the Korean Geosynthetics Society
    • /
    • v.9 no.2
    • /
    • pp.11-20
    • /
    • 2010
  • This paper studies the discharge capacity of vertical drain boards that is controlling hydraulic gradient among many factors in the specification. The KS K 0940(2008), a testing method based on the conventional Delft type method for measuring the discharge capacity of a vertical drain, was specified in Korea Standard recently. In this test method, the variation in hydraulic gradient can result in large differences in the discharge capacity for the same vertical drain board.

  • PDF

Influence of Evjenth-Hamberg Stretching on the Lung Function of Adults with Forward Head Posture

  • Kim, Nyeon Jun;Koo, Ja Pung
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.9 no.4
    • /
    • pp.1663-1668
    • /
    • 2018
  • This study was conducted to examine the effects of Evjenth-Hamberg stretching of the sternocleidomastoid, upper trapezius, and pectoralis major on the lung function of adults with forward neck posture. The subjects were 20 adult students in P university located in Pohang, Korea, whose degree of head forward displacement measured according to NEW YORK state posture test was mild. The subjects were randomly and equally assigned to the Evjenth-Hamberg Stretching group (EHSG, n=10) and the control group (CG, n=10). Their forced vital capacity (FVC), slow vital capacity (SVC), and maximal voluntary ventilation (MVV) were measured before and after the experiment. In within-group comparison, only the EHSG experienced statistically significant improvement in FVC, forced expiratory volume in the first second (FEV1), and peak expiratory flow (PEE) after the experiment, compared to before the experiment (.05

Correlation between the Diaphragmatic Contraction Pressure and the Slow Vital Capacity

  • Lee, Jae-Seok;Han, Dong-Wook;Kang, Tae-Wook
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.14 no.3
    • /
    • pp.47-53
    • /
    • 2019
  • PURPOSE: This study measured the external pressure on abdomen during maximal inspiration. The study determined the correlation between the diaphragmatic contraction pressure and the lung capacities to verify whether or not the measured pressure values can represent diaphragmatic contractility. METHODS: The study included 32 healthy subjects (16 males and 16 females). The researchers fabricated their own diaphragmatic pressure belt (DiP Belt) to measure DCP. DiP Belt device was fixed on the front of the abdomen and the diaphragmatic contractility was measured during maximal inspiration. The lung capacities were measured using a portable digital spirometer device (Pony Fx, COSMED, Italy). A digital spirometer is a device that is used to test the flow of air entering and exiting the lungs. RESULTS: DCP showed significant positive correlations with vital capacity (VC), inspiratory reserve volume (IRV) and inspiratory capacity (IC). Among values of lung capacities, IC showed especially strong positive correlations with the DCP (r =.714, p<.010). For the males, DCP showed significant positive correlations with IRV and IC, and DCP showed significant negative correlation with the expiratory reserve volume (ERV). For the females, DCP showed significant positive correlation with tidal volume (VT), but any significant correlation was not found with any of the other values of lung capacities. CONCLUSION: DCP showed high correlations with IRV and IC associated with inspiratory capacity. Therefore, The DiP Belt can be looked upon as a simple device that is very useful for measuring diaphragmatic contractility.

Development of the Oil Consumption Rate Test Method and Measurement Data Analysis for an Automatic Transmission System (자동변속기 오일 소요유량 시험법개발 및 측정데이터 분석)

  • Jeong, H.S.;Oh, S.H.;Yi, J.S.;Lim, J.S.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.6 no.1
    • /
    • pp.10-16
    • /
    • 2009
  • Automatic power transmission systems consisted of a torque converter and several planetary gear sets, clutches and brakes are controlled by a hydraulic shift control circuit and an electronic transmission control unit. The hydraulic circuit serves for the operation of the torque converter and lubrication oil supply of the transmission system as well as for the actuation of clutches for the automatic gear shift. The complicated hydraulic control circuit constructed by many spools, solenoids, orifices and flow passages are integrated into one small valve block and it is powered by one hydraulic pump. In this paper, a test equipment was developed to measure the oil consumption of each component at various wide operating conditions. Test data about 730 sets acquired from five test items are analyzed and discussed on the oil capacity of the circuit.

  • PDF