• 제목/요약/키워드: flow capacity test

검색결과 344건 처리시간 0.025초

구강 프로바이오틱스와 에센셜 오일 함유 양치액의 구강환경변화 (Changes of Oral Environment Between Probiotics and a Mouthwash Containing Essential Oil)

  • 이수영
    • 대한통합의학회지
    • /
    • 제11권3호
    • /
    • pp.219-226
    • /
    • 2023
  • Purpose : The purpose of this study was to compare changes of salivary flow rate, salivary buffering capacity, and S. mutans after using a mouthwash containing essential oil or probiotics widely used as oral lactic acid bacteria in the oral environment. Methods : Fifty-three healthy adults aged 20 years or older voluntarily participated in this study after they were informed of the purpose of this study. Subjects were divided into a group treated with probiotics (L. reuteri) and a group treated with mouthwash containing essential oil. To evaluate changes in the oral environment, salivary flow rate, salivary buffering capacity, and S. mutans test were performed at baseline and 4 weeks later. Unstimulated and stimulated salivary flow samples were collected for 5 minutes and results were recorded in ml per minute. Salivary buffering capacity was divided into scores of 1 (low), 2 (moderate) and 3 (high) according to the color of the strip. The amount of S. mutans was classified as scores of 0, 1, 2, and 3 according to the decision table. Data collected in this study were analyzed at the 95 % significance level using the SPSS Version 23.0 program. Results : Both the unstimulated salivary flow rate and the stimulated salivary flow rate increased statistically after the intervention compared to those before intervention in the probiotics group. However, there was no statistically significant difference between the probiotics group and the mouthwash group. Salivary buffering capacity and S. mutans results showed no statistically significant differences between the probiotics group and the mouthwash group either. The salivary buffering capacity and the salivary flow rate showed a positive correlation. Conclusion : To improve the oral environment, such as salivary flow rate and salivary buffering capacity, an optimal product can be selected in consideration of individual preference and cost-effectiveness.

순환식 병류형 곡물건조기 개발 (I) -시작기의 성능시험 - (Development of a Rice Circulating Concurrent-flow Dryer (I) - Performance Test of Pilot Scale Dryer -)

  • 한재웅;금동혁;한종규;김훈;홍상진
    • Journal of Biosystems Engineering
    • /
    • 제31권4호
    • /
    • pp.349-354
    • /
    • 2006
  • This study was performed to evaluate the performances for a concurrent flow rice dryer of pilot scale with devices for circulating rice. The pilot scale dryer with the capacity of 700 kg was developed to obtain design informations for the development of actual scale dryer of holding capacity of 10 tons. Three drying tests were conducted at two temperature levels of $100^{\circ}C\;and\;120^{\circ}C$, and two air flow rates levels of $28.5cmm/m^2\;and\;57.1cmm/m^2$. Drying conditions for Test-1, Test-2 and Test-3 were $100^{\circ}C\;-28.5cmm/m^2,\;120^{\circ}C-28.5cmm/m^2\;and\;120^{\circ}-57.1cmm/m^2}$ respectively. Drying rates were 0.73%(w.b./h) for Test-1, 0.90%(w.b./h) for Test-2 and 1.46%(w.b./h) for Test-3. The crack ratios of brown rice after drying ranged from 2.4% to 8.4%, and increased with the increase of drying rate and airflow rate. The energy consumptions were from 6,225 kJ/kg to 6,993 kJ/kg which was higher than that of conventional cross-flow rice circulating type dryer used in Korea. This results were due to the lower ambient air temperatures of $4.5^{\circ}C\;to\;13.4^{\circ}C$ during drying tests.

PVDF 중공사막을 이용한 진공 막 증류 모듈의 공급수 조건에 따른 열성능 특성에 관한 실험적 연구 (An Experimental Study on the Characteristic of Thermal Performance according to Feed Water Conditions to of Vacuum Membrane Distillation Module using PVDF Hollow Fiber)

  • 주홍진;곽희열
    • 상하수도학회지
    • /
    • 제31권4호
    • /
    • pp.339-346
    • /
    • 2017
  • In this study, thermal performance test of VMD module was performed, prior to the construction of the demonstration plant using the vacuum membrane distillation (VMD) module of the capacity of $400m^3/day$ and to the commercialization of the VMD module. For the thermal performance test, the experimental equipment of capacity of $2m^3/day$ was constructed. The permeate flux test and thermal performance test according to feed water conditions such as temperature and flow rate were conducted. The VMD module used in the study was manufactured by ECONITY Co., LTD with PVDF hollow fiber membrane. As a result, the Performance Ratio (PR) of the VMD module showed the maximum value of 0.904 under the condition of feed water temperature of $75^{\circ}C$ and flow rate of $8m^3/h$. PR value of the VMD module using PVDF hollow fiber membrane showed linearly increasing relationship with feed water temperature and flow rate. Also, The permeate flux of the VMD module was analyzed to have maximum value of 18.25 LMH and the salt rejection was 99.99%.

현장성능시험에 의한 터보냉동기의 정상상태모델 개발 (Steady-state Modelling of Centrigugal Chiller through On-Site Test)

  • 장영수;신영기;백영진;김영일
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.83-88
    • /
    • 2001
  • This paper presents modelling and analyzing method of centrifugal chiller which has a rated capacity of 200 RT(703 kW) through on-site performance test. Field data of chiller installed in the clean-room building of KIST have been collected, Simple models were developed for predicting the heat exchangers and system performances by regression of chiller operation data during 5 days in August. The models proposed here account for the effect of variations of cooling capacity, temperatures and flow rates of secondary fluids. The models are consistent with real performance data from June to September within ${\pm}5%$ error. The COP of centrifugal chiller are estimated under the standard rating conditions and reduced mass flow rate of chilled and cooling water.

  • PDF

아이스 슬러리의 원형관내 대류열전달에 관한 연구 (Convective Heat Transfer of Using an Ice Slurry in n circular pipe)

  • 정동주;최은수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.130-135
    • /
    • 2000
  • To enhance heat transfer characteristics of water, fine ice was added to it. The convective heat transfer characteristics of the ice slurry were investigated in a flow loop with a constant heat flux test section. The Nusselt number and Fanning friction coefficient of water flow were found to be similar to the expected curve by Petukhov. The Nusselt number of the ice sin flow was higher than the Nusselt number of water. Effective thermal capacity of the 10.84% ice slurry was found to have 2.39 times of the thermal capacity of water.

  • PDF

평행류 열교환기가 적용된 무선통신 중계기 냉각용 슬림형 공조기 (Slim Air-Conditioner with Parallel Flow Heat Exchangers for Cooling of Telecommunication Cabinet)

  • 조진표;김내현
    • 설비공학논문집
    • /
    • 제21권2호
    • /
    • pp.87-93
    • /
    • 2009
  • Slim telecommunication cabinet cooler, equipped with parallel flow heat exchangers and operating with R-22, is developed. The performance is compared with imported one, equipped with fin-tube heat exchangers and operating with R-134a. Test results show that the newly-developed cooler increases the cooling capacity by 6% and EER by 33%. The refrigerant charge for the developed cooler is 500g compared with 1250g for the imported one. The adoption of parallel flow heat exchanger appears to have reduced the refrigerant charge. In addition, it is shown that the reduced air flow rates through parallel heat exchangers as compared with those through fin-tube heat exchangers are beneficial to the reduction of the equipment noise.

흐름의 입사각이 점성토 지반의 수리저항성능에 미치는 영향 (Effect of Incidence Angle of Current on the Hydraulic Resistance Capacity of Clayey Soil)

  • 김영상;한병덕;강경오
    • 한국해안·해양공학회논문집
    • /
    • 제24권1호
    • /
    • pp.26-35
    • /
    • 2012
  • 지금까지 하천 및 해류에서의 지반의 수리저항 특성에 대한 연구는 흐름의 방향을 고려하지 않고 주 흐름방향에 대해서만 고려해 왔다. 최근 왕복류 흐름에 의한 지반의 수리저항특성에 대한 연구결과에 의하면 세립질 및 조립질 시료 모두에서 일방향 흐름보다 왕복류를 고려한 양방향 흐름에서 세굴률이 크게 발생 하는 것으로 나타났다. 그러나 해안구조물이 설치되는 해안 또는 협곡에서 흐름의 방향은 반드시 $180^{\circ}$를 이루지 않으므로 흐름의 입사각이 지반의 수리저항성능에 미치는 영향에 대한 검토가 반드시 필요하다. 이에 흐름방향을 고려할 수 있도록 개선된 수리저항성능 실험기를 이용하여 인공적으로 조성된 점성 세립질 및 점성 조립질 시료에 대하여 $0^{\circ}$, $90^{\circ}$, $135^{\circ}$, $180^{\circ}$의 입사각을 갖는 흐름에 대한 일방향 및 양방향 수리저항성능을 평가하였다. 실험결과 세립질 및 조립질 시료 모두에서 입사각이 커짐에 따라 수리저항성능은 감소하고 세굴률이 증가하는 것으로 나타났다. 압밀압력이 낮은 경우에는 세립토의 수리저항성능이 급격히 떨어지나 압밀압력이 큰 경우에는 조립토의 수리저항성능이 세립토에 비해 약간 더 빠르게 감소하는 것으로 나타났다. 최종적으로는 양방향 흐름일 경우 가장 큰 세굴률이 발생하므로 다양한 흐름방향에 노출되는 구조물의 경우는 양방향 흐름에 대해 수리저항성능을 평가하는 것이 타당한 것으로 판단된다.

An Experimental Investigation of Thermodynamic Performance of R-22 Alternative Blends

  • Kim, Chang-Nyeon;Park, Young-Moo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.36-44
    • /
    • 1998
  • R-410a and R-407c which have the best potential among R-22 alternatives were tested as drop-in refrigerants against a set of R-22 baseline tests. The performance evaluations were carried out in a psychometric calorimeter test facility using the residential spilt type air conditioner under the ARI rating conditions. Except the lubricant and hand-operated expansion valve, the other parts of the air conditioner were the same with the commercial system. Performance characteristics were measured; compressor power, capacity, VCR, mass flow rate and COP. The tests showed that R-407c can be directly charged into the current refrigeration system because its vapor pressure and other thermochemical properties are similar to those of R-22. However, it is required to change the volume flow rate of compressor in order to achieve the volumetric capacity of R-22. This results from its relatively small VCR and capacity. Meanwhile, R-410a has vapor pressure values too high to be substituted for the current system and this resulted relatively low COP of R-410a compared to that of R-22.

  • PDF

R-22 대체용 혼합냉매의 열역학적 성능에 대한 실험연구 (An experimental investigation of thermodynamic performance of R-22 alternative blends)

  • 황의필;김창년;박영무
    • 설비공학논문집
    • /
    • 제9권1호
    • /
    • pp.82-91
    • /
    • 1997
  • R-410a and R-407c witch have the best potential among the substances being considered as R-22 alternatives were tested as "drop in" refrigerants against a set R-22 baseline tests for comparison. The performance evaluations were carried out in a psychrometric calorimeter test facility using the residential split-type air conditioner under the ARI rating conditions. Other than the use of different lubricant and a hand-operated expansion valve, one of the commercial systems was selected for the experiment. Performance characteristics were measured; compressor power, capacity, VCR, mass flow rate and COP. The tests showed that R-407c can be directly applied to the existing refrigeration system because of its similar vapor pressure and other thermopysical properties with those of R-22. However, it required change to the volume flow rate of compressor in order to achieve the similar performance with R-22 because of its relatively small VCR and capacity. Meanwhile, R-410a has too high a vapor pressure to be applied to the existing system and this feature results in relatively low COP of the system compared to that of R-22. But this could be improved by changing compressor design considering R-410a's relatively high VCR and capacity compared to those of R-22.

  • PDF

Relationship between Saliva Factors Measured Using the SILL-Ha Saliva Test System and Blood Cell Counts according to Perceived Stress Scale Scores in Female College Students

  • Lee, Sun-Mi;Jung, Eun-Ha;Jun, Mi-Kyoung
    • 치위생과학회지
    • /
    • 제21권3호
    • /
    • pp.150-157
    • /
    • 2021
  • Background: Stress as a cause of mental health problems is known to be more prevalent in women than in men and has a negative effect on several aspects of physical health, such as the composition of blood and saliva. This study investigated the relationship of perceived stress with blood cell counts, saliva flow rate, and saliva factors. Methods: We recruited women in their 20s with a high prevalence of stress. Stress was evaluated using the Korean version of the perceived stress scale. Blood tests included white blood cell, hemoglobin, and platelet. We then examined the saliva flow rate and cariogenic bacteria level, acidity, occult blood, buffer capacity, leukocyte level, protein level, and ammonia level using rinse water with the SILL-Ha saliva test system. Results: In a total of 70 participants, the average age was 21.64 years old, the average perceived stress score was 16.96±4.32, and high levels of stress were reported by 80% of the participants (n=56). The high-stress group had lower hemoglobin levels. In addition, the high-stress group showed a lower saliva flow rate than the low-stress group, and there was a difference in the salivary acidity and buffer capacity. The total perceived stress score showed a positive correlation with acidity and negative correlation with buffer capacity and the hemoglobin level. Conclusion: This study found that stress in female college students might affect the composition of blood and saliva. High levels of stress were positively correlated with the hemoglobin level, saliva flow rate, and acidity and negatively correlated with the buffer capacity.