• 제목/요약/키워드: flow balance

검색결과 828건 처리시간 0.054초

FAMILY MOLD의 유동 밸런스와 금형 내압에 관한 연구 (A Study on Flow Balance and Cavity Pressure in Family Mold)

  • 김태철;이대근;홍기복;김영근;박인수
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.603-607
    • /
    • 2002
  • Cavity pressure is a factor of what is occurring inside the mold and is used as one of the process parameters that control the overall injection molding cycle. The insight of cavity pressure is able to predict part quality and optimum process condition. In this paper, it is adapted ejector pin sensor to measure the cavity pressure and investigates the flow balance and the cavity pressure according to different runner thickness for adjusting the flow balance. Flow balance is very important to have not the poor results such as flash and warpage in the family mold. This paper predicted flow balance and cavity pressure using CAE analysis tool and compared with the test results. The results of analysis and test have a good agreement with the cavity pressure profile and flow pattern of the test.

  • PDF

자기장 치료법이 무릎 뼈관절염 환자의 통증 역치, 혈류량 및 균형능력에 미치는 영향 (Effects of Magnetic Therapy to Improve on Pain Threshold, Blood Flow, and Balance in Patient with Knee Osteoarthritis)

  • 김경훈;김동훈
    • 대한통합의학회지
    • /
    • 제11권3호
    • /
    • pp.127-135
    • /
    • 2023
  • Purpose : This study was performed to evaluate the effects of magnetic therapy (MT) on pain threshold, blood flow, and balance in patients with knee osteoarthritis. Methods : A single-blind, randomized controlled trial (RCT) was conducted with 30 patient with knee osteoarthritis. They were randomly allocated 2 groups; magnetic therapy group (MTG; n=15) and placebo magnetic therapy group (PG; n=15). The MTG group received 30 minutes magnetic therapy and 20 minute conservative physical therapy (Hotpack, ICT), magnetic therapy was conducted in magnetic therapy device (OM-100, NUGA, Korea). In the placebo magnetic group received 30 minutes placebo magnetic therapy and 20 minute conservative physical therapy. Each group performed 50 minutes a day 3 times a week for 8 weeks. The primary outcome pressure pain threshold test, blood flow, balance ability were measured by a pressure threshold meter (Commander algometer, JTECH medical, USA), laser dofler image (Moor LDI2-IR, Moor instruments, USA), balance measurement system (BioRescue, Marseille, France). The measurement were performed before and after the 8 weeks intervention period. Results : Both groups demonstrated significant improvement of outcome in pain threshold, blood flow, and balance ability during intervention period. magnetic therapy group revealed significant differences in pain threshold, blood flow, and balance as compared to the placebo magnetic therapy group groups (p<.05). Our results showed that magnetic therapy was more effective than placebo therapy on pain threshold, blood flow, and balance in patients with knee osteoarthritis. Conclusion : Our findings indicate that magnetic therapy can improve pain threshold, blood flow, and Balance, highlight the benefits of magnetic therapy. This study will be able to be used as an intervention data for recovering pain threshold, blood flow, and balance in patients with knee osteoarthritis.

CAE를 이용한 TV Speaker Grille 사출 성형의 최적화 (Optimization Condition for Injection Molding of TV Speaker Grille Using CAE)

  • 김범호;장우진;김정훈;정지원;박영훈
    • 폴리머
    • /
    • 제25권6호
    • /
    • pp.855-865
    • /
    • 2001
  • MOLDFLOW사의 CAE S/W를 사용하여 A사의 TV speaker grille의 최적 성형 조건을 도출하였는데 캐비티 안으로 충전되는 수지의 양을 조절하는 방법 중 flow balance, runner balance, 그리고 이 두 가지를 절충한 세 가지 방법으로 유동과 보압 해석을 수행하였다. 또한 실제로 각각의 온도별 점도와 전단속도를 측정한 결과(local database)를 이용하여 해석하고, standard database에 의한 해석결과와 비교 검토하였다. Speaker grille에서 flow balance는 성형품의 weld line을 최소화함으로써 양호한 외관과 weld line의 기계적 물성 저하를 최소화시켰으나, 제품 중앙부의 과충전으로 인한 과도한 변형이나 gas가 발생하는 단점이 나타났다. Runner balance는 각 gate로부터 사출되는 수지의 양을 균등하게 조절함으로써 flow balance의 단점을 보완하였으나, weld line의 외관과 기계적 물성이 저하하는 단점이 나타났다. 그러나 flow balance와 runner balance를 절충한 형태의 runner의 직경을 변형함으로써 두 방법이 가지는 단점을 보완하였다. 또한 각각의 온도에 대한 점도와 전단속도를 실측한 local database와 기존의 standard database에 의한 해석 결과를 비교한 결과, 실측의 점도가 다소 높게 측정되고 온도 분포의 편차가 넓게 나타났음에도 불국하고 두 data의 해석 결과는 거의 차이가 없음이 확인되었다.

  • PDF

Effects of treadmill training with real optic flow scene on balance and balance self-efficacy in individuals following stroke: a pilot randomized controlled trial

  • Kang, Hyungkyu;Chung, Yijung
    • Physical Therapy Rehabilitation Science
    • /
    • 제1권1호
    • /
    • pp.33-39
    • /
    • 2012
  • Objective: The objective of this study is to investigate the effect of treadmill training with real optic flow scene on functional recovery of balance and balance self-efficacy in stroke patients. Design: Single blind, Randomized controlled trial. Methods: Nine patients following stroke were divided randomly into the treadmill with optic flow group (n=3), treadmill with virtual reality group (n=3), and control group (n=3). Subjects in the treadmill with optic flow group wore a head-mounted display in order to receive a speed modulated real optic flow scene during treadmill training for 30 minutes, while those in the treadmill with virtual reality group and control group received treadmill training with virtual reality and regular therapy for the same amount of time, five times per week for a period of three weeks. Timed up and go test (TUG) and activities-specific balance confidence scale (ABC scale) were evaluated before and after the intervention. Results: TUG in the treadmill training with optic flow group showed significantly greater improvement, compared with the treadmill training with virtual reality group and control group (p<0.05). Significantly greater improvement in the ABC scale was observed in the treadmill training with optic flow group and the tread mill training with virtual reality group, compared with the control group (p<0.05). Conclusions: Findings of this study demonstrate that treadmill training with real optic flow scene can be helpful in improving balance and balance self-efficacy of patients with chronic stroke and may be used as a practical adjunct to routine rehabilitation therapy.

  • PDF

비대면 체간 안정화 운동 프로그램이 근 두께, 체간 근력, 최대 호기량, 정적 균형에 미치는 영향 (Effect of the Untact Trunk Stabilization Exercise Program on Muscle Thickness, Trunk Strength, Maximal Expiratory Flow, and Static Balance)

  • 이동우;정모범
    • 대한물리의학회지
    • /
    • 제16권1호
    • /
    • pp.73-81
    • /
    • 2021
  • PURPOSE: This study examined effects of the untact trunk stabilization exercise program on muscle thickness, trunk strength, maximal expiratory flow, and static balance. METHODS: The subjects were 20 normal adults divided into 10 in the contact exercise group and 10 in the untact exercise group. The trunk stabilization exercise program was conducted for four weeks. The muscle thickness was measured using ultrasound. The maximal expiratory flow was measured using Personal Best Full Range Peak Flow Meter. The static balance was measured through Bio-rescue; and the trunk muscle strength was measured by bending the upper body forward and measuring the time for maintaining the posture. RESULTS: Both contact and untact exercise groups showed significant differences in muscle thickness, muscle strength, maximal expiratory flow, and static balance (p < .05). A significant difference in muscle thickness on ultrasound was observed between the contact and untact exercise groups (p < .05). CONCLUSION: Activation of the transverse abdominal muscle requires accurate instructions of the contact exercise, but despite environmental constraints, the untact exercise program is as effective as the contact exercise for improving muscle strength, maximum expiratory flow, and static balance.

다수 빼기 사출성형에서 캐비티간 충전균형을 위한 새로운 런너의 설계 (A Novel Runner Design for Flow Balance of Cavities in Multi-Cavity Injection Molding)

  • 박서리;김지현;류민영
    • 폴리머
    • /
    • 제33권6호
    • /
    • pp.561-568
    • /
    • 2009
  • 소형 플라스틱 부품들은 대부분 다수 캐비티 빼기 사출금형에서 성형된다. 이러한 다수 빼기 캐비티 금형에서의 사출성형은 캐비티간의 흐름 균형이 중요하다. 캐비티간 흐름의 불균형은 성형품의 캐비티간 물성 및 품질의 편차를 초래한다. 캐비티간의 흐름균형은 런너와 게이트에서의 흐름균형을 통하여 이루어지게 되는데 런너와 게이트에서 기하학적인 균형을 이루어도 열적 불균형으로 캐비티간 흐름의 불균형을 초래한다. 본 연구에서는 캐비티간 흐름의 균형을 위해 고안한 스크류 타입의 런너을 이용하여 캐비티간 충전균형을 고찰하였다. 여러 형태의 스크류 런너에서 결정성 수지와 비결정성 수지, 그리고 점도가 높은 수지와 점도가 낮은 수지를 이용하여 캐비티간 흐름을 관찰하였다. 흐름의 균형은 성형조건 중 사출속도에 따라 다르게 나타나기 때문에 사출속도를 변화해 가며 관찰하였다. 실험 결과를 성형해석과 비교 검토하였으며 서로 잘 일치함을 확인할 수 있었다. 스크류 런너에서 수지가 흐르면서 스크류 채널을 따라 회전운동을 하여 스크류 단면에서 온도가 균일하게 됨을 확인하였다. 그리구 이러한 균일한 온도 때문에 캐비티간 흐름 균형이 이루어지고 있음을 확인하였다. 결론적으로 실험에 사용된 새롭게 고안된 스크류 타입의 런너는 캐비티간 충전균형을 이루는데 매우 효과적임을 실험과 해석을 통해 검증할 수 있었다.

혈류제한 운동이 만성 발목 불안정성을 가진 성인의 발목 근력 및 균형능력에 미치는 영향 (Effects of Blood Flow Restriction Exercise on Ankle Strength and Balance Ability in Adults with Chronic Ankle Instability)

  • 연강미;이효정
    • 대한통합의학회지
    • /
    • 제11권1호
    • /
    • pp.121-130
    • /
    • 2023
  • Purpose : This study aimed to investigate the effect of blood flow restriction exercise on ankle muscle strength and balance ability to achieve maximum efficiency with the same exercise intensity and time. Methods : Twenty-six adults are randomly assigned to experimental group (n=13) and comparison group (n=13). The experimental group performed ankle joint strength exercises with blood flow restriction applied while the comparison group performed ankle joint strength exercises without blood flow restriction applied three times a week for four weeks. The digital muscle measurement, Y-balance test, and Cumberland ankle instability tool were used to evaluate the subject's muscle strength, dynamic balance, and ankle instability index before and after the intervention. Results : In within-group comparison muscle strength, all the two groups showed significant improvements post intervention (p<.05). In between-group comparison, there was significant difference in the change of dorsiflexion, eversion strength pre and post intervention (p<.05). but plantarflexion was no significant difference between pre and post intervention in the group comparison (p>.05). In within-group comparison dynamic balance, all the two groups showed significant improvements post intervention (p<.05). In between-group comparison, there was no significant difference in the change of Y-balance score pre and post intervention (p>.05). In within-group comparison ankle instability index, all the two groups showed significant improvements post intervention (p<.05). In between-group comparison, there was no significant difference in the change of CAIT score pre and post intervention (p>.05). Conclusion : The results of this study show that ankle joint strength exercise improved the strength and balance ability of those complaining of chronic ankle instability, and ankle joint strength exercise applied with blood flow restriction was more effective in dorsiflexion and eversion strength exercise than ankle joint strength exercise without blood flow restriction.

역스월 유로 입력을 가지는 밸런스 슬리브를 적용한 고압 다단 펌프의 진동 특성 (Vibration Characteristics of High Pressure Multi-Stage Pump with Anti-Swirl Injection Balance Sleeve)

  • 곽현덕;이용복;김창호;이봉주
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.214-219
    • /
    • 2002
  • As the tangential flow inside the clearance of tribe elements such as bearings and seals is increased as the shaft speed increases, the system stability will be decreased due to the increment of the instability parameter. To reduce the tangential flow inside the clearance of the balance sleeve, anti-swirl injection mechanism is applied. The balance sleeve is used in resisting the axial force induced by impeller in high pressure multi-stage pump. In this paper, total three cases are experimentally investigated; original balance steeve, anti-swirl injection balance steeve with 0 axial degree and anti-swirl injection balance sleeve with 30 axial degree. Experiments are focused in the comparison of vibration level and leakage flow rate. The results clearly shows that the anti-swirl injection balance sleeve with 0 axial degree improves the vibration characteristics. However, the anti-swirl injection balance sleeve with 30 degree aggravates the vibration characteristics. In the standpoint of leakage performance, both anti-swirl injection balance sleeves show the better result than the original balance sleeve.

  • PDF

역스월 유로 입력을 가지는 밸런스 슬리브를 적용한 고압 다단 펌프의 진동 특성 (Vibration Characteristics of High Pressure Multi-stage Pump with Anti-swirl Injection Balance Sleeve)

  • 곽현덕;이용복;김창호;이봉주
    • 한국소음진동공학회논문집
    • /
    • 제12권8호
    • /
    • pp.632-638
    • /
    • 2002
  • As the tangential flow inside the clearance of tribo elements such as bearings and seals is increased as the shaft speed increases, the system stability will be decreased due to the increment of the instability parameter. To reduce the tangential flow inside the clearance of the balance sleeve, anti-swirl injection mechanism is applied. The balance sleeve is used in resisting the axial force induced by impeller in high pressure multi-stage pump. In this paper, total three cases are experimentally investigated; original balance sleeve, anti-swirl injection balance sleeve with 0 axial degree and anti-swirl injection balance sleeve with 30 axial degree. Experiments are focused in the comparison of vibration level and leakage flow rate. The results clearly shows that the anti-swirl injection balance sleeve with 0 axial degree improves the vibration characteristics. However, the anti-swirl injection balance sleeve with 30 degree aggravates the vibration characteristics. In the standpoint of leakage performance, both anti-swirl injection balance sleeves show the better result than the original balance sleeve.