• Title/Summary/Keyword: flow balance

Search Result 822, Processing Time 0.026 seconds

A Study on Flow Balance and Cavity Pressure in Family Mold (FAMILY MOLD의 유동 밸런스와 금형 내압에 관한 연구)

  • 김태철;이대근;홍기복;김영근;박인수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.603-607
    • /
    • 2002
  • Cavity pressure is a factor of what is occurring inside the mold and is used as one of the process parameters that control the overall injection molding cycle. The insight of cavity pressure is able to predict part quality and optimum process condition. In this paper, it is adapted ejector pin sensor to measure the cavity pressure and investigates the flow balance and the cavity pressure according to different runner thickness for adjusting the flow balance. Flow balance is very important to have not the poor results such as flash and warpage in the family mold. This paper predicted flow balance and cavity pressure using CAE analysis tool and compared with the test results. The results of analysis and test have a good agreement with the cavity pressure profile and flow pattern of the test.

  • PDF

Effects of Magnetic Therapy to Improve on Pain Threshold, Blood Flow, and Balance in Patient with Knee Osteoarthritis (자기장 치료법이 무릎 뼈관절염 환자의 통증 역치, 혈류량 및 균형능력에 미치는 영향)

  • Kyong-Hun Kim;Dong-Hoon Kim
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.11 no.3
    • /
    • pp.127-135
    • /
    • 2023
  • Purpose : This study was performed to evaluate the effects of magnetic therapy (MT) on pain threshold, blood flow, and balance in patients with knee osteoarthritis. Methods : A single-blind, randomized controlled trial (RCT) was conducted with 30 patient with knee osteoarthritis. They were randomly allocated 2 groups; magnetic therapy group (MTG; n=15) and placebo magnetic therapy group (PG; n=15). The MTG group received 30 minutes magnetic therapy and 20 minute conservative physical therapy (Hotpack, ICT), magnetic therapy was conducted in magnetic therapy device (OM-100, NUGA, Korea). In the placebo magnetic group received 30 minutes placebo magnetic therapy and 20 minute conservative physical therapy. Each group performed 50 minutes a day 3 times a week for 8 weeks. The primary outcome pressure pain threshold test, blood flow, balance ability were measured by a pressure threshold meter (Commander algometer, JTECH medical, USA), laser dofler image (Moor LDI2-IR, Moor instruments, USA), balance measurement system (BioRescue, Marseille, France). The measurement were performed before and after the 8 weeks intervention period. Results : Both groups demonstrated significant improvement of outcome in pain threshold, blood flow, and balance ability during intervention period. magnetic therapy group revealed significant differences in pain threshold, blood flow, and balance as compared to the placebo magnetic therapy group groups (p<.05). Our results showed that magnetic therapy was more effective than placebo therapy on pain threshold, blood flow, and balance in patients with knee osteoarthritis. Conclusion : Our findings indicate that magnetic therapy can improve pain threshold, blood flow, and Balance, highlight the benefits of magnetic therapy. This study will be able to be used as an intervention data for recovering pain threshold, blood flow, and balance in patients with knee osteoarthritis.

Optimization Condition for Injection Molding of TV Speaker Grille Using CAE (CAE를 이용한 TV Speaker Grille 사출 성형의 최적화)

  • 김범호;장우진;김정훈;정지원;박영훈
    • Polymer(Korea)
    • /
    • v.25 no.6
    • /
    • pp.855-865
    • /
    • 2001
  • The optimization condition of injection molding for a commercial product of TV speaker grille of A Company was induced using a CAE software of Moldflow. The flow and packing phase analysis was performed by using flow balance, runner balance, and the intermediate one by using the above two balances, which were used for controlling the amount of packing resins into the cavity, Later, the analysis performed by using the measured viscosity (local database) at various shear rates and the results were compared with the computer simulation using the standard database. Flow balance induced minimized weld line resulted in a better appearance and physical properties of the were line, but exhibited a disadvantage of large deformation and gas formation due to over-packing of the molten resin in the center of the speaker grille. Runner balance improved the disadvantage of the flow balance by controlling the amount of molten resin injected from the gate, however resulted reduced mechanical properties and poor appearance of the weld line. However, the modified method induced from the flow and runner balance improved the disadvantages by changing the runner size. In addition, the analyses based on the local database and the standard database were compared. Although the measured viscosity was slightly higher and the temperature distribution was broader than the standard database, no distinct difference was obtained from the analysis using the two different databases.

  • PDF

Effects of treadmill training with real optic flow scene on balance and balance self-efficacy in individuals following stroke: a pilot randomized controlled trial

  • Kang, Hyungkyu;Chung, Yijung
    • Physical Therapy Rehabilitation Science
    • /
    • v.1 no.1
    • /
    • pp.33-39
    • /
    • 2012
  • Objective: The objective of this study is to investigate the effect of treadmill training with real optic flow scene on functional recovery of balance and balance self-efficacy in stroke patients. Design: Single blind, Randomized controlled trial. Methods: Nine patients following stroke were divided randomly into the treadmill with optic flow group (n=3), treadmill with virtual reality group (n=3), and control group (n=3). Subjects in the treadmill with optic flow group wore a head-mounted display in order to receive a speed modulated real optic flow scene during treadmill training for 30 minutes, while those in the treadmill with virtual reality group and control group received treadmill training with virtual reality and regular therapy for the same amount of time, five times per week for a period of three weeks. Timed up and go test (TUG) and activities-specific balance confidence scale (ABC scale) were evaluated before and after the intervention. Results: TUG in the treadmill training with optic flow group showed significantly greater improvement, compared with the treadmill training with virtual reality group and control group (p<0.05). Significantly greater improvement in the ABC scale was observed in the treadmill training with optic flow group and the tread mill training with virtual reality group, compared with the control group (p<0.05). Conclusions: Findings of this study demonstrate that treadmill training with real optic flow scene can be helpful in improving balance and balance self-efficacy of patients with chronic stroke and may be used as a practical adjunct to routine rehabilitation therapy.

  • PDF

Effect of the Untact Trunk Stabilization Exercise Program on Muscle Thickness, Trunk Strength, Maximal Expiratory Flow, and Static Balance (비대면 체간 안정화 운동 프로그램이 근 두께, 체간 근력, 최대 호기량, 정적 균형에 미치는 영향)

  • Lee, Dong-Woo;Jeong, Mo-Beom
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.16 no.1
    • /
    • pp.73-81
    • /
    • 2021
  • PURPOSE: This study examined effects of the untact trunk stabilization exercise program on muscle thickness, trunk strength, maximal expiratory flow, and static balance. METHODS: The subjects were 20 normal adults divided into 10 in the contact exercise group and 10 in the untact exercise group. The trunk stabilization exercise program was conducted for four weeks. The muscle thickness was measured using ultrasound. The maximal expiratory flow was measured using Personal Best Full Range Peak Flow Meter. The static balance was measured through Bio-rescue; and the trunk muscle strength was measured by bending the upper body forward and measuring the time for maintaining the posture. RESULTS: Both contact and untact exercise groups showed significant differences in muscle thickness, muscle strength, maximal expiratory flow, and static balance (p < .05). A significant difference in muscle thickness on ultrasound was observed between the contact and untact exercise groups (p < .05). CONCLUSION: Activation of the transverse abdominal muscle requires accurate instructions of the contact exercise, but despite environmental constraints, the untact exercise program is as effective as the contact exercise for improving muscle strength, maximum expiratory flow, and static balance.

A Novel Runner Design for Flow Balance of Cavities in Multi-Cavity Injection Molding (다수 빼기 사출성형에서 캐비티간 충전균형을 위한 새로운 런너의 설계)

  • Park, Seo-Ri;Kim, Ji-Hyun;Lyu, Min-Young
    • Polymer(Korea)
    • /
    • v.33 no.6
    • /
    • pp.561-568
    • /
    • 2009
  • Small injection molded articles are generally molded by multi-cavity injection molding. The most important thing in multi-cavity molding is flow imbalance among the cavities because it affects the physical property and the quality of products. The cavity filling balance can be achieved by flow balance in the runner through the thermal balance. In this study, novel screw type runner or helical type runner has been developed for the flow balance in the runner and performed experiment and computer simulation. Flow balance has been observed using various screw type runners for several resins such as amorphous and crystalline polymers including low and high viscosities grades. Flow balance experiments have been performed for various injection speeds since the flow balance can be affected by injection speed among the injection conditions. Experimental results have been compared with computational results and they showed good agreement. The cavity filling balance can be achieved by the screw runner where the temperature distribution is uniform through the circulation flow along the screw channel in the screw runner. It has been verified that the novel screw runner is very effective device in flow balance in the multi-cavity injection molding. cavity filling imbalance, multi-cavity injection molding, runner design, screw runner, thermal balance.

Effects of Blood Flow Restriction Exercise on Ankle Strength and Balance Ability in Adults with Chronic Ankle Instability (혈류제한 운동이 만성 발목 불안정성을 가진 성인의 발목 근력 및 균형능력에 미치는 영향)

  • Gang-Mi Youn;Hyo-Jeong Lee
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.11 no.1
    • /
    • pp.121-130
    • /
    • 2023
  • Purpose : This study aimed to investigate the effect of blood flow restriction exercise on ankle muscle strength and balance ability to achieve maximum efficiency with the same exercise intensity and time. Methods : Twenty-six adults are randomly assigned to experimental group (n=13) and comparison group (n=13). The experimental group performed ankle joint strength exercises with blood flow restriction applied while the comparison group performed ankle joint strength exercises without blood flow restriction applied three times a week for four weeks. The digital muscle measurement, Y-balance test, and Cumberland ankle instability tool were used to evaluate the subject's muscle strength, dynamic balance, and ankle instability index before and after the intervention. Results : In within-group comparison muscle strength, all the two groups showed significant improvements post intervention (p<.05). In between-group comparison, there was significant difference in the change of dorsiflexion, eversion strength pre and post intervention (p<.05). but plantarflexion was no significant difference between pre and post intervention in the group comparison (p>.05). In within-group comparison dynamic balance, all the two groups showed significant improvements post intervention (p<.05). In between-group comparison, there was no significant difference in the change of Y-balance score pre and post intervention (p>.05). In within-group comparison ankle instability index, all the two groups showed significant improvements post intervention (p<.05). In between-group comparison, there was no significant difference in the change of CAIT score pre and post intervention (p>.05). Conclusion : The results of this study show that ankle joint strength exercise improved the strength and balance ability of those complaining of chronic ankle instability, and ankle joint strength exercise applied with blood flow restriction was more effective in dorsiflexion and eversion strength exercise than ankle joint strength exercise without blood flow restriction.

Vibration Characteristics of High Pressure Multi-Stage Pump with Anti-Swirl Injection Balance Sleeve (역스월 유로 입력을 가지는 밸런스 슬리브를 적용한 고압 다단 펌프의 진동 특성)

  • 곽현덕;이용복;김창호;이봉주
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.214-219
    • /
    • 2002
  • As the tangential flow inside the clearance of tribe elements such as bearings and seals is increased as the shaft speed increases, the system stability will be decreased due to the increment of the instability parameter. To reduce the tangential flow inside the clearance of the balance sleeve, anti-swirl injection mechanism is applied. The balance sleeve is used in resisting the axial force induced by impeller in high pressure multi-stage pump. In this paper, total three cases are experimentally investigated; original balance steeve, anti-swirl injection balance steeve with 0 axial degree and anti-swirl injection balance sleeve with 30 axial degree. Experiments are focused in the comparison of vibration level and leakage flow rate. The results clearly shows that the anti-swirl injection balance sleeve with 0 axial degree improves the vibration characteristics. However, the anti-swirl injection balance sleeve with 30 degree aggravates the vibration characteristics. In the standpoint of leakage performance, both anti-swirl injection balance sleeves show the better result than the original balance sleeve.

  • PDF

Vibration Characteristics of High Pressure Multi-stage Pump with Anti-swirl Injection Balance Sleeve (역스월 유로 입력을 가지는 밸런스 슬리브를 적용한 고압 다단 펌프의 진동 특성)

  • 곽현덕;이용복;김창호;이봉주
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.8
    • /
    • pp.632-638
    • /
    • 2002
  • As the tangential flow inside the clearance of tribo elements such as bearings and seals is increased as the shaft speed increases, the system stability will be decreased due to the increment of the instability parameter. To reduce the tangential flow inside the clearance of the balance sleeve, anti-swirl injection mechanism is applied. The balance sleeve is used in resisting the axial force induced by impeller in high pressure multi-stage pump. In this paper, total three cases are experimentally investigated; original balance sleeve, anti-swirl injection balance sleeve with 0 axial degree and anti-swirl injection balance sleeve with 30 axial degree. Experiments are focused in the comparison of vibration level and leakage flow rate. The results clearly shows that the anti-swirl injection balance sleeve with 0 axial degree improves the vibration characteristics. However, the anti-swirl injection balance sleeve with 30 degree aggravates the vibration characteristics. In the standpoint of leakage performance, both anti-swirl injection balance sleeves show the better result than the original balance sleeve.