High Performance Flexible Inorganic Electronic Systems

  • Park, Gwi-Il;Lee, Geon-Jae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.115-116
    • /
    • 2012
  • The demand for flexible electronic systems such as wearable computers, E-paper, and flexible displays has increased due to their advantages of excellent portability, conformal contact with curved surfaces, light weight, and human friendly interfaces over present rigid electronic systems. This seminar introduces three recent progresses that can extend the application of high performance flexible inorganic electronics. The first part of this seminar will introduce a RRAM with a one transistor-one memristor (1T-1M) arrays on flexible substrates. Flexible memory is an essential part of electronics for data processing, storage, and radio frequency (RF) communication and thus a key element to realize such flexible electronic systems. Although several emerging memory technologies, including resistive switching memory, have been proposed, the cell-to-cell interference issue has to be overcome for flexible and high performance nonvolatile memory applications. The cell-to-cell interference between neighbouring memory cells occurs due to leakage current paths through adjacent low resistance state cells and induces not only unnecessary power consumption but also a misreading problem, a fatal obstacle in memory operation. To fabricate a fully functional flexible memory and prevent these unwanted effects, we integrated high performance flexible single crystal silicon transistors with an amorphous titanium oxide (a-TiO2) based memristor to control the logic state of memory. The $8{\times}8$ NOR type 1T-1M RRAM demonstrated the first random access memory operation on flexible substrates by controlling each memory unit cell independently. The second part of the seminar will discuss the flexible GaN LED on LCP substrates for implantable biosensor. Inorganic III-V light emitting diodes (LEDs) have superior characteristics, such as long-term stability, high efficiency, and strong brightness compared to conventional incandescent lamps and OLED. However, due to the brittle property of bulk inorganic semiconductor materials, III-V LED limits its applications in the field of high performance flexible electronics. This seminar introduces the first flexible and implantable GaN LED on plastic substrates that is transferred from bulk GaN on Si substrates. The superb properties of the flexible GaN thin film in terms of its wide band gap and high efficiency enable the dramatic extension of not only consumer electronic applications but also the biosensing scale. The flexible white LEDs are demonstrated for the feasibility of using a white light source for future flexible BLU devices. Finally a water-resist and a biocompatible PTFE-coated flexible LED biosensor can detect PSA at a detection limit of 1 ng/mL. These results show that the nitride-based flexible LED can be used as the future flexible display technology and a type of implantable LED biosensor for a therapy tool. The final part of this seminar will introduce a highly efficient and printable BaTiO3 thin film nanogenerator on plastic substrates. Energy harvesting technologies converting external biomechanical energy sources (such as heart beat, blood flow, muscle stretching and animal movements) into electrical energy is recently a highly demanding issue in the materials science community. Herein, we describe procedure suitable for generating and printing a lead-free microstructured BaTiO3 thin film nanogenerator on plastic substrates to overcome limitations appeared in conventional flexible ferroelectric devices. Flexible BaTiO3 thin film nanogenerator was fabricated and the piezoelectric properties and mechanically stability of ferroelectric devices were characterized. From the results, we demonstrate the highly efficient and stable performance of BaTiO3 thin film nanogenerator.

  • PDF

(Development of Ring Core Auto-Classifier by Multi-Motor Control) (여러 개의 모터에 의하여 제어되는 링-코어 자동 선별기 개발)

  • Park, In-Gyu
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.39 no.2
    • /
    • pp.104-115
    • /
    • 2002
  • Core is the main component of inductor. This core should be classified into around 10 classes according to the value of inductance and Q. The coil should be winded with the outer-boundary of this core by different number of turns. Theses kind of precise inductors would be required in the future environment which PCs and communication devices demand more high speed and lower voltage level. It would be quite unefficient that only one core is classified once a time. There, it will be developed so that 10 cores are classified simultaneously. For the operation of classifying 10 cores once in a time, suppose 10 test instruments could be used. In this case, it would take much cost since a test instrument Is expensive. So, by using only one test instrument, it is really more desirable that this system is developed. Each core classified by 10 different classes is to be stored into the corresponding box through the corresponding rubber hose. 10 cores are passed on a serial line and are placed on each testing slot. Here, each core located at each slot is tested, and then the bowl located on the top of a step motor is moved into the corresponding spot by rotating step motor with some angles. Each bowl connected with the corresponding box through rubber hose. Actually 100 hoses are connected, 10 step motors are rotated at 10 different angles, so the size is really so big, the shape of connecting 100 hoses is so complicated. Therefore it is anticipated that the system would be going to be easily out of ordered. In this paper the main purpose is to make several suggestions to be able to work well in these kinds of being affected by the abnormal operation of motors and the flow of cores.

Cardiopulmonary Resuscitation and Pediatric Advanced Life Support for Pediatric Dentist (소아치과의사를 위한 심폐소생술과 소아고급생명구조술)

  • Kim, Jongbin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.2
    • /
    • pp.243-255
    • /
    • 2017
  • Cardiopulmonary resuscitation (CPR) is an emergency treatment that stimulates blood circulation and breathing when the function of the heart stops or stops breathing. CPR can be divided by basic life support (BLS) and advanced life support (ALS). BLS involves the use of chest compression to force the blood flow to the main organs, rescue breathing to improve the breathing to the respiratory failure patient and the use automated external defibrillator (AED). The categories of advanced life support include advanced cardiovascular life support (ACLS) for adult and pediatric advanced life support (PALS) for children. In the treatment of dental care for children, which is extremely difficult to deal with, and for a variety of reasons, the use of sedation is considered to treat the children who are unlikely to cooperate with dentistry. This is why there is an increasing possibility of an emergency situation involving cardiac arrest. PALS includes the BLS, and it presents a systematic algorithm to treat respiratory failure, shock and cardiogenic cardiac arrest. In order to manage emergency situations in the pediatric dental clinic, respiratory support is most important. Therefore, mastering professional PALS, which includes respiratory care and core cases, particularly upper airway obstruction and respiratory depression caused by a respiratory control problem, would be highly desirable for a physician who treats pediatric dental patients. Regular training and renewal training every two years is necessary to be able to immediately implement professional skills in emergency situations.

DENTAL MANAGEMENT OF A PATIENT WITH MOYAMOYA DISEASE UNDER GENERAL ANESTHESIA (모야모야병(moyamoya disease) 환자의 전신마취 하 치과 치료)

  • Sang, Eun Jung;Song, Ji-Soo;Shin, Teo Jeon;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg;Lee, Sang-Hoon;Hyun, Hong-Keun
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.13 no.2
    • /
    • pp.108-113
    • /
    • 2017
  • Moyamoya disease is a disorder in which certain arteries in the brain are constricted. Blood flow can be blocked by the constriction and blood clots. The patients frequently experience transient ischemic attacks (TIA), cerebral hemorrhage, or may not experience any symptoms at all. It is reported that they have a higher risk of recurrent stroke and a distinct underlying pathophysiology. A 3-year-8-month old boy with moyamoya disease experienced cerebral infarctions five times, and he underwent a cerebrovascular anastomosis surgery four years ago. He showed swallow disturbance, general delayed development, hemiplegia, and strabismus. Also he had hypocalcified teeth with or without multiple caries lesions in all dentitions. Dental treatment under general anesthesia using sevoflurane was performed due to his lack of cooperation. Moyamoya disease is associated with various medical conditions requiring a thoughtful deliberation and a careful examination before and during dental treatment. Pain and anxiety control during dental treatment is important because hyperventilation induced by crying has been seen to trigger TIA. Both isoflurane and sevoflurane are commonly used in patients with MMD, but dynamic autoregulation is better preserved during sevoflurane than isoflurane anesthesia. So sevoflurance general anesthesia may be recommendable to manage dental patients having multiple caries with moyamoya disease.

A Study on Chemical Compositions of Sediment and Surface Water in Nakdong River for Tracing Contaminants from Mining Activities (광해오염원 추적을 위한 낙동강 지역 퇴적물 및 하천수의 화학조성 연구)

  • Kim, Jiyun;Choi, Uikyu;Baek, Seung-Han;Choi, Hye-Bin;Lee, Jeonghoon
    • Journal of the Korean earth science society
    • /
    • v.37 no.4
    • /
    • pp.211-217
    • /
    • 2016
  • There have been found mine tailings, wastes, and mining drainage scattered in the area of Nakdong River due to the improper maintenance of the abandoned mines. These contaminants can flow into rivers during the heavy rain periods in summer. Along the study area beginning Seokpo-myeon, Bonghwa-gun of Gyeongsangbuk-do untill Dosan-myeon, Andong-si, there are one hundred five mines including sixty metalliferous mines and forty-five nonmetal mines, which can adversely affect the adjacent rivers. To verify the contamination, we collected sediments, seepage water and surface water for a year both in rainy season and dry season. This study found that sediments, containing high concentrations of heavy metals caused by mining activities, are dispersed throughout the entire river basin (68 sample points with pollution index, based on the concentration of trace element, (PI) >10 among the total of 101 samples). The results of river water analysis indicated the increased concentrations of arsenic and cadmium at branches from Seungbu, Sambo, Okbang and Janggun mine, which concerns that the river water may be contaminated by mining drainage and tailing sediments. However, it is difficult to sort out the exact sources of contamination in sediments and waters only by using the chemical compositions. Thus the control of mining pollution is challenging. To prevent water from being contaminated by mining activities, we should be able to divide inflow rates from each origin of the mines. Therefore, there should be a continued study about how to trace the source of contaminants from mining activities by analyzing stable isotopes.

HPLC Method for Simultaneous Quantitative Detection of Quercetin and Curcuminoids in Traditional Chinese Medicines

  • Ang, Lee Fung;Yam, Mun Fei;Fung, Yvonne Tan Tze;Kiang, Peh Kok;Darwin, Yusrida
    • Journal of Pharmacopuncture
    • /
    • v.17 no.4
    • /
    • pp.36-49
    • /
    • 2014
  • Objectives: Quercetin and curcuminoids are important bioactive compounds found in many herbs. Previously reported high performance liquid chromatography ultraviolet (HPLC-UV) methods for the detection of quercetin and curcuminoids have several disadvantages, including unsatisfactory separation times and lack of validation according the standard guidelines of the International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use. Methods: A rapid, specific, reversed phase, HPLC-UV method with an isocratic elution of acetonitrile and 2% v/v acetic acid (40% : 60% v/v) (pH 2.6) at a flow rate of 1.3 mL/minutes, a column temperature of $35^{\circ}C$, and ultraviolet (UV) detection at 370 nm was developed. The method was validated and applied to the quantification of different types of market available Chinese medicine extracts, pills and tablets. Results: The method allowed simultaneous determination of quercetin, bisdemethoxycurcumin, demethoxycurcumin and curcumin in the concentration ranges of $0.00488-200{\mu}g/mL$, $0.625-320{\mu}g/mL$, $0.07813-320{\mu}g/mL$ and $0.03906-320{\mu}g/mL$, respectively. The limits of detection and quantification, respectively, were 0.00488 and $0.03906{\mu}g/mL$ for quercetin, 0.62500 and $2.50000{\mu}g/mL$ for bisdemethoxycurcumin, 0.07813 and $0.31250{\mu}g/mL$ for demethoxycurcumin, and 0.03906 and $0.07813{\mu}g/mL$ for curcumin. The percent relative intra day standard deviation (% RSD) values were $0.432-0.806{\mu}g/mL$, $0.576-0.723{\mu}g/mL$, $0.635-0.752{\mu}g/mL$ and $0.655-0.732{\mu}g/mL$ for quercetin, bisdemethoxycurcumin, demethoxycurcumin and curcumin, respectively, and those for intra day precision were $0.323-0.968{\mu}g/mL$, $0.805-0.854{\mu}g/mL$, $0.078-0.844{\mu}g/mL$ and $0.275-0.829{\mu}g/mL$, respectively. The intra day accuracies were 99.589%-100.821%, 98.588%-101.084%, 9.289%-100.88%, and 98.292%-101.022% for quercetin, bisdemethoxycurcumin, demethoxycurcumin and curcumin, respectively, and the inter day accuracy were 99.665%-103.06%, 97.669%-103.513%, 99.569%-103.617%, and 97.929%-103.606%, respectively. Conclusion: The method was found to be simple, accurate and precise and is recommended for routine quality control analysis of commercial Chinese medicine products containing the flour flavonoids as their principle components in the extracts.

Estimation of Travel Time in Natural River and Dam Outflow Conditions Considering Rainfall Conditions and Soil Moisture Accounting (강우조건과 토양함수상태를 고려한 자연하천과 댐 방류량 조건에서의 도달시간 산정)

  • Kim, Dong Phil;Kim, Kyoung Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.4
    • /
    • pp.537-545
    • /
    • 2018
  • Determination of the time parameters such as the travel time in the design flood is very important. The travel time is mainly used for flood and river management, and the travel time of non flood season is used for maintenance flow and management of the river. Estimation of travel time for natural rivers is mainly based on the geomorphological factors of the basin. In addition to the topographical factors, the travel time is calculated by considering the factors of the runoff curve, velocity and rainfall intensity. However, there is no study on the estimation of travel time considering both the rainfall condition and the soil moisture accounting by the frequency period. Therefore, the travel time calculation is divided into the case of setting the Hwanggang Dam and the Imjin bridge water level station of Imjin river as the natural river considering rainfall condition by the frequency period and the soil moisture accounting, and the case of traveling the Imjin bridge water level station according to the condition of outflow of the Hwanggang Dam. For the sections set as natural rivers, the results were verified by comparing with the newly developed travel time calculation method. Based on the results, the travel times of the Hwanggang Dam outflow conditions were calculated. The time to travel in this study can be secured flood control of the Imjin river basin and time to prepare for danger when outflowing the the Hwanggang Dam.

Similitude Law on Material Non-linearity for Seismic Performance Evaluation of RC Columns (RC기둥의 내진성능평가를 위한 재료비선형 상사법칙)

  • Lee, Do-Keun;Cho, Jae-Yeol
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.3
    • /
    • pp.409-417
    • /
    • 2010
  • This paper discusses a series of experiments including material improvement in order to ensure quality of grouting for the post-tensioned structure. In prestressed concrete, grouting refers to the construction procedure of filling empty space of duct enclosing with strands using cementitious material, To date, adequate quality control of the grouting has not been established in Korea because the relationship between the grouting and durability of post-tensioned structure is not well-recognized. The Korean standard does not consider the important material characteristic, wick effect, which is caused by strands in the ducts and current standard testing method unlikely quantify reasonable material segregation. As a result, the grout material, which meets the current material standards, may exhibit excessive bleeding water or shrinkage during construction. In this study, international codes and standards related to grouting were surveyed. The ratio of constituents and novel admixtures were suggested to meet equivalently with these standards. Performance of this enhanced grout was compared to common domestic grout using the international standard testing method. A series of mock-up specimens considering geometry of PC beam was constructed and grout flow pattern was observed as the grout was injected. It was observed that the grouting performance was highly influenced by material properties and filling characteristic can be varied depending on geometry of ducts.

Principles and Applications of Multi-Level H2O/CO2 Profile Measurement System (다중 수증기/이산화탄소 프로파일 관측 시스템의 원리와 활용)

  • Yoo, Jae-Ill;Lee, Dong-Ho;Hong, Jin-Kyu;Kim, Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.11 no.1
    • /
    • pp.27-38
    • /
    • 2009
  • The multi-level profile system is designed to measure the vertical profile of $H_2O$ and $CO_2$ concentrations in the surface layer to estimate the storage effects within the plant canopy. It is suitable for long-term experiments and can be used also in advection studies for estimating the spatial variability and vertical gradients in concentration. It enables the user to calculate vertical fluxes of water vapor, $CO_2$ and other trace gases using the surface layer similarity theory and to infer their sources or sinks. The profile system described in this report includes the following components: sampling system, calibration and flow control system, closed path infrared gas analyzer(IRGA), vacuum pump and a datalogger. The sampling system draws air from 8 inlets into the IRGA in a sequence, so that for 80 seconds air from all levels is measured. The calibration system, controlled by the datalogger, compensates for any deviations in the calibration of the IRGA by using gas sources with known concentrations. The datalogger switches the corresponding valves, measures the linearized voltages from the IRGA, calculates the concentrations for each monitoring level, performs statistical analysis and stores the final data. All critical components are mounted in an environmental enclosure and can operate with little maintenance over long periods of time. This report, as a practical manual, is designed to provide helpful information for those who are interested in using profile system to measure evapotranspiration and net ecosystem exchanges in complex terrain.

Occurrence of Fusarium wilt on Cyclamen Casued by Fusarium oxysporum f. sp. cyclaminis and Selection of Resistant Cultivars (Fusarium oxysporum f. sp. cyclaminis에 의한 시클라멘 시들음병 발생 및 저항성 품종 선발)

  • Kim, Jin-Young;Kim, Hong-Gi;Hong, Sun-Sung;Kim, Jin-Won;Park, Kyeong-Yeol
    • Research in Plant Disease
    • /
    • v.9 no.2
    • /
    • pp.79-84
    • /
    • 2003
  • A wilt disease of commercial cyclamen (Cyclamen persicum) which grown in greenhouse was found in Gyeo-nggi province of Korea during the period from August, 2001 to July, 2002. The disease incidence was up to 42.7% in Kimpo, Gyeonggi province. The disease was more severe in ebb and flow irrigation system than con-ventional overhead flooding\'s. The wilted cyclamen plants showed the chlorosis of leaves and followed by the death. The vascular tissues of the infected basal stem and bulb were discolored with black streaks. The casual fungus was identified to be Fusarium oxysporum f. sp. cyclaminis on the basis of mycological characteristics. Effect of infected soil showed 100% infection rate when the cyclamen plants were grown in potting with infested soil. Examine resistant cultivar showed ‘Matis red’, ‘Schubert’, ‘Victoria’ and ‘Chopin’ were the resistant cultivars but most of cultivars were susceptible to Fusarium wilt. The control effect of chemicals for cyclamen wilt was not much efficient to curative effects even though. Benomyl WP and Fludioxonil SC on the Fusarium wilt had only preventive effects by soil drenching in the pot before inoculation of F. oxysporum. This is the first report on the fusarium wilt of cyclamen caused by F. oxysporum f. sp. cyclaminis in Korea.