Proposed Distribution Voltage Control Method for Connected Cluster PV Systems

  • Lee, Kyung-Soo;Yamaguchi, Kenichiro;Kurokawa, Kosuke
    • Journal of Power Electronics
    • /
    • v.7 no.4
    • /
    • pp.286-293
    • /
    • 2007
  • This paper proposes a distribution voltage control method when a voltage increase condition occurs due to reverse power flow from the clustered photovoltaic (PV) system. This proposed distribution voltage control is performed a by distribution-unified power flow controller (D-UPFC). D-UPFC consists of a hi-directional ac-ac converter and transformer. It does not use any energy storage component or rectifier circuit, but it directly converts ac to ac. The distribution model and D-UPFC voltage control using the ATP-EMTP program were simulated and the results show the voltage increase control in the distribution system.

Development of A New Device for Controlling Infinitesimal Flows inside a Lab-On-A-Chip and Its Practical Application (랩온어칩 내부 미세유동 제어를 위한 새로운 장치의 개발 및 적용)

  • Kim, Bo-Ram;Kim, Guk-Bae;Lee, Sang-Joon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.305-308
    • /
    • 2006
  • For controlling micro-flows inside a LOC (lab-on-a-chip) a syringe pump or an electronic device for EOF(electro-osmotic flow) have been used in general. However, these devices are so large and heavy that they are burdensome in the development of a portable micro-TAS (total analysis system). In this study, a new flow control system employing pressure chambers, digital switches and speed controllers was developed. This system could effectively control the micro-scale flows inside a LOC without any mechanical actuators or electronic devices We also checked the feasibility of this new control system by applying it to a LOC of micro-mixer type. Performance tests show that the developed control system has very good performance. Because the flow rate in LOC is controlled easily by throttling the speed controller, the flows in complicate microchannels network can be also controlled precisely.

  • PDF

FFC Design for PI Flow Control System Designed by CDM

  • Oh, Kyu-Kwon;Yu, Kee-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.151.3-151
    • /
    • 2001
  • A design of PI controller to be used to control the first-order lag plus dead time process, such as a flow process, by the coefficient diagram method (CDM) is investigated. The factor of the dead time of process is first approximated to be the first-order by the Pade approximation. The response of the flow control system designed by CDM satisfy both transient and steady state specifications. However, the transient response generally still has long rise time. In order to improve the speed of the system response, a feedforward controller (FFC) is added into the PI control system. The structure of the FFC is a phase lead structure with two designed parameters and one derivative time obtained from the reaction curve of the flow process ...

  • PDF

A Study on the Control Characteristics of FHA by Using PLC (PLC를 이용한 ER밸브-FHA의 제어특성에 관한 연구)

  • Jang, Sung-Cheol;Hong, Soon-Nam
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.2
    • /
    • pp.331-336
    • /
    • 2013
  • The purpose of this study is to visualize the characteristics of ER fluids as preceding step of developing 3 port ER valves. As the strength of the electric field increases, more clusters in flow are made and these clusters are thought to be the reasons of the load flow rate being increased and the outlet flow rate being decreased. The ER Valves and load and outlet flow rate check method are considered to be applied to the fluid power control system. Using the manufactured pressure control valve, a one-link manipulator with FHA in robot system is driven. As a result, it is experimentally confirmed that the pressure control valve using ER fluids is applicable to use in driving actuator. If it applies characteristics of the ER fluids, it will be able to apply in the control system for the ER Valve which occurs from industrial controller(PLC).

Power Flow Control of Four Channel Resonant Step-Down Converters

  • Litvani, Lilla;Hamar, Janos
    • Journal of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.1393-1402
    • /
    • 2019
  • This paper proposes a new power flow control method for soft-switched, four channel, five level resonant buck dc-dc converters. These converters have two input channels, which can be supplied from sources with identical or different voltages, and four output channels with arbitrary output voltages. They are specially designed to supply multilevel inverters. The design methodology for their power flow control has been developed considering a general case when the input voltages, output voltages and loads can be asymmetrical. A special emphasize is paid to the limitations and restrictions of operation. The theoretical studies are confirmed by numerical simulations and laboratory tests carried out at various operation points. Exploiting the advantages of the newly proposed power control strategy, the converter can supply five level inverters in dc microgrids, active filters, power factor correctors and electric drives. They can also play an interfacing role in renewable energy systems.

A Computational Study of the Fluidic Thrust Vector Control Using Secondary Flow Injection (2차 유동 분사를 이용한 추력벡터 제어에 관한 수치해석적 연구)

  • Lim, Chae-Min;Kim, Heuy-Dong
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.496-501
    • /
    • 2003
  • Computational study is performed to understand the fluidic thrust vectoring control of an axisymmetric nozzle, in which secondary gas injection is made in the divergent section of the nozzle. The nozzle has a design Mach number of 2.0, and the operation pressure ratio is varied to obtain the different flow features in the nozzle flow. The injection flow rate is varied by means of the injection port pressure. Test conditions are in the range of the nozzle pressure ratio from 3.0 to 8.26 and the injection pressure ratio from 0 to 1.0. The present computational results show that, for a given nozzle pressure ratio, an increase of the injection pressure ratio produces increased thrust vector angle, but decreases the thrust efficiency.

  • PDF

Experimental Study of the Superheat and Control of the Refrigerant Flow-Rate in the Evaporator of a Multi-type Air-Conditioning System (멀티형 공조시스템의 증발기 과열도에 관한 실험적 연구 및 냉매유량 제어)

  • 김태섭;홍금식;손현철
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.221-221
    • /
    • 2000
  • The heat exchange part in a modern multi-type air-conditioning system employs multiple-pass heat exchangers. The heat-transfer performance of an each pass in such an exchanger depends strongly on the length of the two-phase region and the mass flow of the refrigerant. The total length and diameters of the pipes, the exit conditions, and the arrangement of each pass as well as the geometrical shape of the distributor at the branching sections are considered to be major factors affecting the heat-transfer performance. The refrigerant commonly used in these systems is HCFC-22. The two objectives of this paper are to investigate the characteristics of the refrigerant flow rate and the superheat in the evaporator of a multi-type air-conditioning system for a single or simultaneous operating conditions and to control the superheat and the refrigerant flow rate of the evaporator.

  • PDF

A Method for Estimating Fluid Force in Proportional Directional Control Valves with Spool (스풀형 비례 방향/유량제어밸브의 유체력 검증법)

  • Lee, I.Y.;Son, J.M.;Shin, H.B.;Son, J.H.
    • 유공압시스템학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.109-115
    • /
    • 2010
  • In establishing a simulation program for hydraulic valves, it is always a big obstacle to incorporate correctly flow forces on valve body into the simulation program. This paper suggests a method to estimate flow forces on spool in proportional directional/flow control valves with spool structure. Furthermore, suggests a way to obtain simulation program for spool valves, in which flow force mechanism is fully reflected.

  • PDF

Applicable Road Design Method of Debris-Flow Control Structure (토석류 차단시설의 도로적용 설계 방안)

  • Lee, Yong-Soo;Kim, Jin-Hwan;Yu, Jun;Chung, Ha-Ik
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.243-246
    • /
    • 2009
  • Localized rainfall due to abnormal climate has caused extensive damages killing several tens to hundreds of people for yearly basis. The typhoon 'Lusa' of year 2002 has resulted 5,400 billion won of property damage and the damages for roads were approximated to be 2,860 billion won at 12,377 locations holding 53% damage of total. The recent typhoon, 'Aewinia' of yeat 2006 caused the 1,400 billion-won property damage including sweeping and flooding of 127 roads and 65 rivers, respectively. There are needs to minimize the damages for important structures for repeated heavy rainfalls every year and, especially, because debris flow might be a main cause of road damage, the design criteria and guideline for roads are required to be improved. Therefore, this paper presented design method of debris-flow control structure for road protection.

  • PDF

A Study on Development of Vane Damper for Industry Flow Control Fan (산업용 유량제어 송풍기 베인댐퍼 개발에 관한 연구)

  • Yi, Chung-Seob;Jeong, In-Guk;Yun, Ji-Hun;Suh, Jeong-Se;Jang, Sung-Cheol
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.1
    • /
    • pp.137-143
    • /
    • 2012
  • In this study, it was conducted to design each components of vane damper for industrial flow control fan and the flow rates were analysed by experimental and numerical method. Through environmental test, it could be confirmed that the designed vane damper was appropriate. Also, almost identical results with test could be drawn from numerical method. Finally, flow rates of electric and pneumatic actuator were measured by test. As the results, difference of flow rate according to opening ratio was smaller in pneumatic actuator than that in electric actuator.