• Title/Summary/Keyword: floor-plans

Search Result 281, Processing Time 0.031 seconds

A Study on the Design Guidelines of a Storage for Conservation of Relics in a Museum (문화재 보존을 위한 박물관 수장고의 공간계획 지침 연구)

  • Jung Sung-Wook
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.3 s.56
    • /
    • pp.144-154
    • /
    • 2006
  • Except the time when relics of a museum are exhibited or loaned to the public, they are stored in a storage. In addition, it is common view that collections are exhibited a few of total stored collections in a museum. Therefore, the environmental condition of a storage is an important factor. Hereby, the purpose of this study is to suggest the design guidelines of a storage for conservation of relics in a museum. The results from this study are as follows briefly. First, location of storages has to be located and centralized above ground against preservation environment and additional renovation. Second, for storage size, It is reasonable to secure long-term experimental data after planning about 20% of whole section in present domestic situation. Third, in order to prevent environmental deterioration due to short storage floor space, adequate storage height has to be secured against a mezzanine deck and spare storages need to be planned. Where a mezzanine deck is designed, detailed plans have to be supported for equal micro climate in a storage. Fourth, in respect of environmental control of storages, finish materials with adjustment ability on relative humidity have to be used after the system is installed jointly direct and indirect way by air chamber, considering domestic condition for management of intermittent ventilation.

A Study on the Office Space by Gwathmey Siegel (구아쓰미 씨게일의 업무공간에 관한 연구)

  • 김용립
    • Korean Institute of Interior Design Journal
    • /
    • no.9
    • /
    • pp.98-107
    • /
    • 1996
  • The purpose of this study is to find out the characteristics of the office space as designed by Gwathemy Siegel and thereby to understand the current trend of interior design of working space in the United States. Unlike most architects, Gwathmey Siegel have extended themselves into interior designing of over twenty offices including law firms, financial institutions and design firms and have successfully won reputation as interior designers. They have distinguished themselves by their ability to turn up and take advantage of the possbility of shaping in a given structure. Their liberal use of fixed furniture and architectural lighting , in addition to ceilings and walls , set them apart from others in the field . The major design elements and principles of Gwathmey Siegel include, among others : 1) Curved and slanted walls on the floor plans endow the office space with forms. Fixed furniture and architectural lighting frequently serve as from -creating elements. 2) The openness of the reception and waiting areas and the irregularity of the corridor walls add a sense of variety in the office. 3) In terms of color and materials, subtle changes of texture and value and the various patterns of joint lines further enrich the space. 4) The principle of symmetry , rough or partial , as applied in the layout of rooms and furniture creates a sense of balance in the space.

  • PDF

Review of Research Literature on Interruptions and Performance for Hospital Design: Hospital and Office Comparison (병원 디자인을 위한 업무간섭에 관한 문헌조사 연구: 병원과 사무실의 비교)

  • Seo, Hyun-Bo
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.20 no.1
    • /
    • pp.27-34
    • /
    • 2014
  • Purpose: The purpose of this study was to identify the role of the physical environment in task interruptions in the healthcare settings. Many dangerous events such as airplane crash and medical errors are the result of human errors and, these errors are often the result of interruptions during a critical task of professional workers. In fact, the physical environment that determines accessibility and visibility among people affects interruptions significantly, but architectural studies have given little attention to the management of interruptions. Methods: Therefore, the researcher reviewed research literature in other fields to find out how the physical environment affected interruptions. Many studies were from management, human factors, and health care, but few from architecture. First the author examined the impact of interruptions, second described the social context of interruptions and the role of the physical environment. Results: Findings included that description of the physical environment was not very clear in studies from management and human factors, while little work had been done on interruptions in architecture. The author proposed study design that compensated shortcomings of each field by combining approaches from management, human factors, and architecture. Implications: Unit design strategies such as distributed nurse stations can affect interruptions and layout analysis such as space syntax analysis can evaluate visibility and accessibility of floor plans in the preliminary design phase.

A Study on the Reference Building based on the Building Design Trends for Non-residential Buildings (건축물 설계현황 분석을 통한 국내 비주거용 표준건물의 설정에 관한 연구)

  • Jeong, Young-Sun;Jung, Hae-Kwon;Jang, Hee-Kyung;Yu, Ki-Hyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.1-11
    • /
    • 2014
  • The Korean government plans to introduce the building energy performance standard which regulates the annual energy consumption of buildings. This paper aimed to set up the reference building from database based on the building design trends for non-residential buildings. We surveyed the design data of 435 non-residential buildings which were granted building permission from 2007 to 2011. And we conducted estimation on the heating & cooling load and the energy consumption of the reference building using ECO2 program. From results, the reference building of non-residential buildings was office building which had a total 7 floors and $20,838m^2$ gross floor area. And it suggests the design reference data of building envelope, HAVC, heat source equipment and lighting system for the reference building. The total annual energy use of the reference building was $151.9kWh/m^2yr$.

A Study on the Guideline of Spatial Composition and Circulation in Triages and Entrances Area in Emergency Departments for Efficient Infection Control (응급부 진입구역과 환자분류구역의 감염관리를 위한 환자동선과 공간구성 계획에 대한 연구)

  • Kang, Jeeeun;Kwon, Soonjung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.25 no.1
    • /
    • pp.41-49
    • /
    • 2019
  • Purpose: After Mers breakout in 2015, major hospital in Korea have been renovated the emergency department to make a separate infection control zone for high-risk patient with potential infection and to improve a triage area and an entrance area for efficient patient evaluation. However, there are no specific design standards to reinforce infection control for patients and staffs safety. Therefore, it is important to establish of initial design factors in the triage and entrance area as a guideline. Methods: 5 cases which had been recently renovated are selected to analyze patient circulation and spatial composition in a triage area and an entrance area. The partial floor plans of each case are represented as bubble diagrams to help understanding of different patient circulation flows. Based on this analysis, significant design factors which should be considered in planning stage for infection control have been extracted. Results: 13 design factors are established. Using these design factors, patient circulation diagram is generated to provide an optimized suggestion for efficient infection control. Implications: This suggestion provides basic databases to start to establish design guideline in the triage area and the entrance area to minimize infection spreading in the emergency department.

Analysis on the Building System Integration Methods of the Salk Institute for Biological Studies (솔크 생물학 연구소에 적용된 건물시스템 통합기법 분석에 관한 연구)

  • Choi, Joon Sung
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.7
    • /
    • pp.59-68
    • /
    • 2018
  • Salk Institute for Biological studies is widely considered as architectural masterpiece of Louis Kahn's. Its iconic plaza with symmetrical concrete structures, overlooking the Pacific ocean in La Jolla, has been acclaimed as a facade to the sky. Little has been written on Kahn's achievements in the building system integration in order to bridge the gap between technology and design. This paper explores the technical issues, the design intents, and the major building systems to identify the Kahn's integration methods between building systems. The project is analysed into four major systems; structure, mechanical, envelope, and interior system. The integration methods of building systems are investigated in physical, visual, and functional aspects. The most distinguished cases of building system integration are the introduction of the interstitial floors between the laboratories and the creation of the smooth and warm materiality of exposed concrete walls. Kahn proposed open floor plans for the laboratories which are capable of easily adapting to changing needs. He also introduced the interstitial floors which are framed of the vierendeel truss systems and deliberately overlapped the structure systems with the mechanical systems such as ducts, water pipes, and electric conduits. The exposed concrete walls mixed with pozzolan ashes look very much like granite or limestone as the result of the physical and visual integration between structure, envelope, and interior systems.

A Study on the Critical Safety Management Buildings and factors by Analyzing the Actual State of Building Safety Management (건축물 안전관리 실태분석을 통한 중점안전관리 대상 및 요소 설정에 관한 연구)

  • Kim, Eun-Hee
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.35 no.4
    • /
    • pp.37-44
    • /
    • 2019
  • According to the statistical surveys and studies, insufficient maintenance in the use of existing buildings caused fire and collapse accidents. In this respect, I analyzed the data managed by the current building maintenance and inspection system to find out the actual state of safety management and proposed two significant results. First, regarding the state of the buildings, the safety management status of the small-sized ones, where 20 years or more passed after construction, is the worst and a priority improvement plan is required. Second, there are eight deeply concerning factors for the fire incidents and collapse accidents of buildings. In the order of high risk, these factors are structural strength (seismic design), exterior wall finishing material, basement floor, interior finishing materials, other evacuation facilities, corridors stairs entrances, rooftop, fire partition. We need to have more special designs and management plans regarding high-risk factors as a system to prevent accidents in the building.

A Study on the Analysis of the Spatial Composition of Rehabilitation Department in Regional Public Hospital (지방의료원 재활의학부의 공간구성 분석 연구)

  • Lee, Joorang;Chai, Choul Gyun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.27 no.1
    • /
    • pp.35-44
    • /
    • 2021
  • Purpose: To presenting basic data for the spatial composition required when planning the future department of rehabilitation medicine by analyzing the spatial composition of the location, size, area, and plan type of the rehabilitation department of the Regional Public Hospital. Methods: 3 Methods have been used in this paper. 1) Analyzing drawings to derive the net floor area of each room. 2) A literature survey about rehabilitation healthcare system. 3) Observation survey for user circulation analysis. Results: 1) Rehabilitation is an overall process of treatment that helps to play a role as an individual in society, away from the perspective of treating physical damage. The Department of Rehabilitation Medicine of the local medical center must provide rehabilitation medical services corresponding to the recovery and maintenance period for community rehabilitation. 2) The Department of Rehabilitation Medicine can be classified into diagnostics area, examination area, treatment area, management area, and interface area based on the rehabilitation treatment process. Implication: It can be used as basic data when planning related facilities by analyzing the characteristics of the space plan of the required room according to the relationship between activities, movement lines, and operation plans based on user behavior.

Denoising Traditional Architectural Drawings with Image Generation and Supervised Learning (이미지 생성 및 지도학습을 통한 전통 건축 도면 노이즈 제거)

  • Choi, Nakkwan;Lee, Yongsik;Lee, Seungjae;Yang, Seungjoon
    • Journal of architectural history
    • /
    • v.31 no.1
    • /
    • pp.41-50
    • /
    • 2022
  • Traditional wooden buildings deform over time and are vulnerable to fire or earthquakes. Therefore, traditional wooden buildings require continuous management and repair, and securing architectural drawings is essential for repair and restoration. Unlike modernized CAD drawings, traditional wooden building drawings scan and store hand-drawn drawings, and in this process, many noise is included due to damage to the drawing itself. These drawings are digitized, but their utilization is poor due to noise. Difficulties in systematic management of traditional wooden buildings are increasing. Noise removal by existing algorithms has limited drawings that can be applied according to noise characteristics and the performance is not uniform. This study presents deep artificial neural network based noised reduction for architectural drawings. Front/side elevation drawings, floor plans, detail drawings of Korean wooden treasure buildings were considered. First, the noise properties of the architectural drawings were learned with both a cycle generative model and heuristic image fusion methods. Consequently, a noise reduction network was trained through supervised learning using training sets prepared using the noise models. The proposed method provided effective removal of noise without deteriorating fine lines in the architectural drawings and it showed good performance for various noise types.

Experimental investigation of local stress distribution along the cross-section of composite steel beams near joints

  • Sangwook Park;Patricia Clayton;Todd A. Helwig;Michael D. Engelhardt;Eric B. Williamson
    • Steel and Composite Structures
    • /
    • v.51 no.5
    • /
    • pp.563-573
    • /
    • 2024
  • This research experimentally evaluated the local stress distribution along the cross-section of composite beams under both positive and negative moments. The experiment utilized a large-scale, two-story, two-by-three bay steel gravity frame with a concrete on metal deck floor system. The composite shear connections, which are nominally assumed to be pinned under gravity loading, can develop non-negligible moment-resisting capacity when subjected to lateral loads. This paper discusses the local stress distribution, orshear lag effects, observed near the beam-to-column connections when subjected to combined gravity and lateral loading. Strain gauges were used for measurements along the beam depth at varying distances from the connection. The experimental data showed amplified shear lag effects near the unconnected region of the beam web and bottom flange under the applied loading conditions. These results indicate that strain does not vary linearly across the beam cross-section adjacent to the connection components. This insight has implications for the use of experimental strain gauge data in estimating beam demands near the connections. These findings can be beneficial in informing instrumentation plans for future experimental studies on composite beams.