• Title/Summary/Keyword: floor-plans

Search Result 281, Processing Time 0.023 seconds

A Study of Korean Traditional Housing Design Characteristics Reflected in Apartment Model Houses in Busan (아파트 모델하우스에 나타난 한국 전통주거의 디자인 특성에 관한 연구)

  • 이양경;오찬옥
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2002.04a
    • /
    • pp.66-70
    • /
    • 2002
  • The purpose of this study was to identify the Korean traditional housing design characteristics in apartment model houses. 37 floor plans of apartment model houses in Busan were collected and analyzed. Also, 31 design element check-lists were checked through the field study in apartment model houses. The results were as follows: 1) Korean traditional housing design characteristics in aspects of space organization, such as harmony with nature, hierarchy, focal space, flexibility, were founded in apartment houses. 2) Korean traditional housing design characteristics in aspects of scale, material, color, and motif were mostly founded in the master bedroom and the living room in apartment house. 3) Also, the larger the size of apartment houses were, the more Korean traditional housing design characteristics were founded.

  • PDF

A Study on the Characteristics of the Interior Design of the Apartments in Busan - Focused on the living rooms of apartment units in modelhouse - (부산지역 아파트의 실내디자인 특성에 관한 연구 - 모델하우스의 거실공간을 중심으로 -)

  • 윤지영
    • Korean Institute of Interior Design Journal
    • /
    • no.32
    • /
    • pp.47-54
    • /
    • 2002
  • This study attempts to analyze the characteristics of interior design of the apartments in Busan that people will reside since 2001 and to find out the effects of minimalism in the interior space. The companies which are in construction of the apartments of more than 50 Pyung were selected, and the design of the living rooms of their model houses were analyzed in terms of the floor plans, architectural elements, furniture and lightings. The results reveals that the living rooms of the newly-distributed apartments in Busan show similar design characteristics without distinctive differences among the companies. The new trends provide a flexible wall which makes it possible to manipulate the number of rooms according to the family preference, art-wall design in one-side of the walls and a coffered ceiling design, which can be interpreted to be closely related to the concept of minimalism with expression of simple horizontal and vertical lines, exclusive use of decorative forms, colors and materials, and use of natural materials

A COMPUTER SIMULATION MODEL AS A MEANS OF EMERGENCY EVACUATION TRAINING FOR CONSTRUCTION PROJECTS

  • Chung-Suk Cho;Dong-Cheol Shin
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.864-868
    • /
    • 2009
  • Fire safety management on any construction site should start with recognizing fire risks in the workplace, understanding the extent of the risks, and proper assessment of the controls necessary to reduce the risks. However, the most important step to prevent fire-related accidents on jobsites is the constant review and monitoring of processes and controls by all individuals involved. This study was conducted to analyze the effectiveness of using computer simulation as an addition to maps or floor plans in safety training and management. Simulex was used on a real project to model various egress routes and to identify potential problem areas of the evacuation strategy. This study highlights the efficacy of simulated emergency evacuation as a training tool that visually shows constantly altering means of egress.

  • PDF

Analysis on Energy Demand Resulting From the Change in Window Area & Installation of Interior Exterior Blinds (기존 노후건축물의 최적 리모델링 개선안 연구)

  • Kim, Dae-Won;Chung, Kwang-Seop;Kim, Young-Il;Nam, Ariasae;Oh, Se Min
    • Journal of Energy Engineering
    • /
    • v.23 no.2
    • /
    • pp.207-216
    • /
    • 2014
  • The energy loss can be divided into the loss caused by heat transfer and the loss caused by air flow. Heat transfer is the loss resulting from the heat transmittance of external wall, roof, and floor, and represents one of the most vulnerable elements of existing buildings. To prevent such loss, it is necessary to increase the mean heat transmittance of entire external wall, including the window, to a level above the standard regional value and ensure the air-tightness of window. The old buildings have the structure which is prone to the loss of greater air flow due to the air infiltration through the exit/entrance door upward along the stairway by the stack effect and simultaneous suction of air from each floor, and becomes even vulnerable to the loss of heat insulation for each floor, although the external wall and windows are the most vulnerable parts. The improvement plans for each floor need to be submitted in tandem with the diagnosis of whole building, regarding the diagnosis plan and energy improvement measures based on the survey of site, rather than adhering to the misconception that the replacement of window alone will result in energy-savings.

Sound Pressure and Vibration Characteristics of Reinforced Concrete Slab with Heavy Weight Mortar for Cross-section Recovery (단면 회복용 중량 모르타르를 사용한 철근콘크리트 슬래브의 음압 및 진동 특성)

  • Jae-Sung Kim;Jin-Man Kim
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.12 no.3
    • /
    • pp.298-305
    • /
    • 2024
  • This paper is a basic study to improve floor impact noise of reinforced concrete slabs. Considering the case where thickness differences occur due to construction, changes in sound insulation characteristics were analyzed when the cross section of a reinforced concrete slab was restored with mortar. The houses subject to analysis were divided into two types, 84 type and 59 type, with different floor plans. When pre-mortaring was done with heavy mortar to restore the cross section on the reinforced concrete slab, the case was when pre-mortaring was done with the reinforced concrete slab alone and with general mortar. Compared with, the difference between vibration acceleration level and sound pressure was measured. As a result of measuring the vibration acceleration level of the slab after pouring the mortar, the CS mortar was 66.4 dB and the ES mortar was 66.1 dB at 84 type 63 Hz, which was more than 2 dB lower than that of regular mortar. In addition, compared to the reinforced concrete slab alone, CS mortar was reduced by 5.5 dB and ES mortar was reduced by 4.6 dB, showing relatively excellent values. As for the floor impact sound pressure, the 84B type was similar at 63 Hz for CS mortar and general mortar at 67.3 dB, and the reduction compared to the reinforced concrete slab alone was 3.6 dB for CS mortar, 2.7 dB for ES mortar, and 2.7 dB for general mortar was reduced by 1.4 dB. By pouring mortar to compensate for the thickness of the reinforced concrete slab, the vibration acceleration level and floor impact noise were reduced, and when a heavy mortar using copper smelting slag fine aggregate was used, relatively excellent performance was found.

A Study on the Possibility of Producing a Floor Plan of 「Donggwoldo(東闕圖)」 through the Use of Rubber Sheeting Transformation - With a Focus on the Surroundings near the Geumcheongyo Bridge in Changdeokgung Palace - (러버쉬팅변환을 통한 「동궐도(東闕圖)」의 평면도 제작 가능성 연구 - 창덕궁 금천교 주변을 중심으로 -)

  • Lee, Jae-Yong;Kim, Young-Mo
    • Korean Journal of Heritage: History & Science
    • /
    • v.50 no.4
    • /
    • pp.104-121
    • /
    • 2017
  • The present study attempted to produce the floor plan of the surroundings near Geumcheongyo Bridge in Changdeokgung Palace of the Late Joseon Period through the use of rubber sheeting transformation based on the drawing principles of "Donggwoldo(東闕圖)". First, the study compared the actual sizes of the major buildings that have existed since the production of "Donggwoldo(東闕圖)" with the sizes depicted in the picture to reveal that the front elevation of the buildings was produced by reducing it by approximately 1/200. However, the study could not confirm the same production proportions for the side elevation. Only the lengths of the side elevation were depicted at around half of the actual proportions, and as the diagonal line angles were found to be at an average of $39^{\circ}$, the study confirmed they were drawn in a manner similar to cabinet projection. Second, the study created an obliquely projected floor plan by inversely shadowing the drawing principles of "Donggwoldo(東闕圖)" and produced a floor plan of the surroundings near Geumcheongyo Bridge in Changdeokgung Palace through the use of rubber sheeting transformation. Projective transformation was confirmed as most suitable during the transformation, and with standard error of 2.1208m, the relatively high accuracy of the transformation shows that the production of a floor plan for "Donggwoldo(東闕圖)" is significant. Furthermore, it implies the possibility of producing floor plans for various documentary paintings produced using the paralleled oblique drawing method in addition to "Donggwoldo(東闕圖)". Third, the study evaluated the accuracy of the spatial information provided by the produced floor plan by comparing the three items of Geumcheongyo Bridge location, Geumcheongyo Bridge and Jinseonmun Gate arrangement, and Geumcheon stone embankment location. The results confirmed the possibility of utilizing the floor plan as a useful tool which helps understand the appearance of the surroundings at the time of "Donggwoldo(東闕圖)" production because it is parallel to the excavation results of the Geumcheongyo Bridge and its context. Therefore, the present study is significant in that it seeks the possibility of producing spatial information recorded in "Donggwoldo(東闕圖)" by applying rubber sheeting transformation and consequently in that it presents a new methodology for understanding the appearance of the East Palace of the Late Joseon Period.

Development of BIM Templates for Vest-Pocket Park Landscape Design (소공원의 조경설계를 위한 BIM 템플릿 개발)

  • Seo, Young-hoon;Kim, Dong-pil;Moon, Ho-Gyeong
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.44 no.1
    • /
    • pp.40-50
    • /
    • 2016
  • A BIM, which is being applied actively to the construction and civil construction industries, is a technology that can maximize efficiency of various sectors from initial planning and design, construction, and maintenance, to demolition; however, it is in the introductory phase in the field of domestic landscaping. In order to introduce and promote BIM in the field of landscape design, this study developed a prototype of a library and template and analyzed the performance of trial application. For the development of a prototype, annotations and types were analyzed from floor plans of existing small parks, and components of landscape template were deduced. Based on this, play facilities, pergola, and benches were madeintofamily and templates, making automatic design possible. In addition, annotations and tags that are often used in landscape design were made, and a 3D view was materialized through visibility/graphic reassignment. As for tables and quantities, boundary stone table, mounding table, summary sheet of quantities, table of contents, and summary sheet of packaging quantities were grouped and connected with floor plans; regarding landscaping trees, classification criteria and name of trees that are suitable for domestic situations were applied. A landscape template was created to enable the library file format(rfa) that can be mounted on a building with BIM programs. As for problems that arose after the trial application of the prepared template, some CAD files could not be imported; also, while writing tables, the basis of calculation could not be made automatically. Regarding this, it is thought that functions of a BIM program and template need improvement.

A Study on the Architectural Planning Characteristics of Medical Buildings - Focused on Cheong-ju Area (메디컬빌딩의 건축계획특성 연구 - 청주지역을 중심으로)

  • Baek, Sang Yeol;Kim, Gi Soo
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.21 no.3
    • /
    • pp.69-77
    • /
    • 2015
  • Purpose: Under a trend of hospitals that repeated expansion in line with fast increasing factors of medical demands in the past, medical buildings where clinic businesses have regularly gathered in one building have exponentially increased since separation of prescribing and dispensing in 2000. Thus, this study aims at analyzing characteristics of architectural plan of the current medical buildings, identifying strengths and weaknesses through Post Occupancy Evaluation and suggesting an architectural planning method of medical buildings to be planned in the future. Methods: Scope of study has been limited to 23 medical buildings that are registered in the building register as medical buildings out of the Class 1 neighborhood facilities build as 5 floors or more in Cheongju region since 2000 and being actually used for the usage. Study method is to define concepts of the medical buildings through literature review and advanced researches, analyze characteristics of architectural plan through drawing analysis and site survey. Results: General characteristics of architectural plans for the medical buildings in Cheongju have been analyzed. There are the most frequencies in general commercial area and semi-residential area, most of them are reinforced concrete structure and the Class 1 neighborhood facilities. Average land area is $482.68m^2$, gross floor area $3720.8m^2$, the number of underground floors level 1.16, the number of floors level 7.76, total number of floors 8.92, the building-to-land ratio 67.28%, floor area ratio 452.6%, height 31.44m, and the number of parked vehicles 24.16. Implications: This research will contribute to the establishment of the planning methods which increase the quality of Medical Buildings in Cheongju.

A Study on Area Planning of Air Conditioning Room for Hospital Design Focused on System (체계중심병원설계를 위한 공조실 면적 계획에 관한 연구)

  • Kim, Eun Seok;Yang, Nae Won
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.25 no.4
    • /
    • pp.27-35
    • /
    • 2019
  • Purpose: As the improvement in quality of medical environment and the spatial consideration for the prevention of infection in the hospital have become increasingly important in the recent years, specific and practical planning for air conditioning room's area has become a major issue accordingly. However, the air conditioning room tends to be discussed focusing on technical factors such as air conditioning systems that are irrelevant to building plans, while discussions of most departments related to the medical functions have actively taken placed. Therefore, this study aims to investigate the factors influencing the planning for the air conditioning room area, and through subsequent analysis of the area of the air conditioning room, to propose a way to improve effective planning for the air conditioning room area. Methods: This study examines the case hospitals that fall into two types: each floor supply system and concentrated supply system, and compares and analyzes the air conditioning room area-related factors and the characteristics of changes in the interior of air conditioning room before and after remodeling through air conditioning floor plan of those case hospitals. Results: The air conditioning room can be classified into the net area of the functional space such as duct passages, and the public area such as aisle space, and of those the public area is an important factor in calculating the area of the air conditioning room. The public area of the air-conditioning room should not be planned considering only the spaces for mobile passage or maintenance activities, but should be planned taking into account internal changes such as expansion and replacement of equipment in the future from the beginning. Implications: When planning a medical facility, it is used as basic data for the planning of the air conditioning room area, which is a significant fixed factor in the initial setting.

Study on the Escape Safety of University Dormitory with the Consideration of Plan Types (대학 기숙사의 평면 형태에 따른 피난 안전성 검토)

  • Jeong, Hyeon-Jae;Jeong, Gun-Sik;Ahn, Young-Chull
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.6
    • /
    • pp.1-7
    • /
    • 2010
  • University dormitory has some weaknesses against disaster such as fire because of high population density and strict control of access in night time. The purpose of this study is suggestion of a guide of effective floor plan for improvement of evacuation safety. Plans for preventing disasters are studied and evacuation safeties are analysed using network model analysis method according to plan types. The weakness of disaster prevention is quantified, and effectiveness of bidirectional evacuation is confirmed. The circuit type floor plan shows best evacuation characteristics and this result is anticipated to be adopted to design process of new dormitories and will contribute to improvement of evacuation safety.