• 제목/요약/키워드: floor stiffness

검색결과 229건 처리시간 0.025초

Connection stiffness and natural frequency of DuraGal lightweight floor systems

  • Zhao, X.L.;Taplin, G.;Alikhail, M.
    • Structural Engineering and Mechanics
    • /
    • 제15권3호
    • /
    • pp.269-284
    • /
    • 2003
  • This paper reports a series of component tests on a lightweight floor system and a method to predict the natural frequency of the floor using a frame analysis program. Full-scale floor tests are also briefly described. DuraGal steel Rectangular Hollow Sections (in-line galvanised RHS) are used as joists, bearers and piers in DuraGal lightweight floor systems. A structural grade particleboard is used as decking. Connection stiffness between different components (bearer, joist, pier and floor decking) was determined. A 40% composite action was achieved between the RHS joist and the particleboard. Both 2D and 3D models were developed to study the effect of connection stiffness on predicting the natural frequency of DuraGal lightweight floor systems. It has been found that the degree of shear connection between the bearer and the joist has a significant influence on the floor natural frequency. The predicted natural frequencies are compared with measured values from full scale floor testing.

완충재 동탄성계수와 경량바닥충격음 저감량의 상관성 (Correlation Between Dynamic Stiffness of Resilient Materials and Lightweight Floor Impact Sound Reduction Level)

  • 김경우;정갑철;손장열
    • 한국소음진동공학회논문집
    • /
    • 제18권8호
    • /
    • pp.886-895
    • /
    • 2008
  • Resilient materials are generally used for the floating floors to reduce the floor impact sound. Dynamic stiffness of resilient material have a close relation with the floor impact sound reduction. In this study, to examine the relationship between dynamic stiffness and lightweight impact sound level, the dynamic stiffness and floor impact sound level of 51 resilient materials were measured. The impact sound level of each of these resilient materials, whose dynamic stiffness was measured, was measured before and after installation, and the level difference (${\Delta}L$) was analyzed. The result of test showed that the dynamic stiffness of resilient materials decreased, the lightweight impact sound level also decreased, and there was a correlation between the dynamic stiffness and the lightweight impact sound, especially in the low frequency domain.

초고층건물 초기 구조시스템 선정을 위한 강성증가요인 효과 분석 (Analysis of Effects of Stiffness Increment Factors for Deciding the Initial Structural System of Tall Buildings)

  • 이재철;정종현
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2007년도 정기 학술대회 논문집
    • /
    • pp.857-862
    • /
    • 2007
  • The purpose of this research is to compare the stiffness increment effects with the floor plan shapes by the stiffness increment factors. For this, we generated the standard floor plans with Box and T type shapes. Then applied the stiffness increment factors -outrigger, material strength, member section- to those floor plans, and generated several alternative analysis models that make the effects of the factors to the lateral displacement exposed. Finally, we analyzed the stiffness increment effects and compared with each other by the stiffness increment factors. As a result, we found that the increment effects have not influence to floor plan shapes, and orders of stiffness increment effects are outrigger, core wall and material strength. We expect that the results of this study could be effectively utilized in the schematic structural design of tall buildings.

  • PDF

바닥판의 휨강성이 고층건물의 지진거동에 미치는 영향 (The Effect of the flexural stiffness of Floor Slabs on The Seismic Response of Multi-story Building Structures)

  • 김현수
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring
    • /
    • pp.170-177
    • /
    • 2000
  • Recently many high-rise apartment buildings are constructed using the box system which is composed only of concrete walls and slabs. Commercial softwares such as ETABS used for the analysis of high-rise apartment buildings are employing the rigid diaphragm assumption for simplicity in the analysis procedure. In general the flexural stiffness of floor slabs are ignored in the analysis, This assumption may be reasonable for the estimation of seismic response of framed structures. But in the case of the box system used in the apartment buildings floor slabs has major effects on the lateral stiffness of the structure. So if the flexural stiffness of slabs in the box system is ignored the lateral stiffness may be significantly underestimated, For these reasons it is recommended to use plate elements to represent the floor slabs. In the study A typical frame structure and a box system structure are chosen as the example structure. When a 20 story frame structure is subjected to the static lateral loads the displacements of the roof are 15.33cm and 17.52cm for the cases with and without the flexural stiffness of the floor slabs. And in case of box system the roof displacement was reduced from 16.18cm to 8.61cm The model without the flexural stiffness of floor slabs turned out to elongate the natural periods of vibration accordingly.

  • PDF

완충재 구성방법에 따른 동탄성계수 및 중량바닥충격음 저감특성 평가 (Evaluation of the Dynamic Stiffness and Heavy-weight Floor Impact Sound Reduction by Composition of Resilient Materials)

  • 김경우;정갑철;손장열
    • 한국소음진동공학회논문집
    • /
    • 제18권2호
    • /
    • pp.247-254
    • /
    • 2008
  • Resilient materials are generally used for the floating floors to reduce the floor impact sound. Dynamic stiffness of resilient material, which has the most to do with the floor impact sound reduction. The resilient materials available in Korea include EPS(styrofoam), recycled urethane types, EVA(ethylene vinylacetate) foam rubber, foam PE(polyethylene). glass fiber & rock wool, recycled tire, foam polypropylene. compressed polyester, and other synthetic materials. In this study, we tested dynamic stiffness of resilient material and floor impact sound reduction characteristic to a lot of kinds of resilient materials. It was found that dynamic stiffness of multi-layered damping material could be estimated if know value of each layer that compose whole structure. And the test showed that the amount of the heavy-weight impact sound reduction appeared by being influenced from this dynamic stiffness of resilient material. The dynamic stiffness looked like between other resilient materials, a similar to the amount of the heavy-weight impact sound reduction was shown.

분리된 천정의 설치를 통한 목구조 바닥의 내화성능 및 충격음 차단성능 향상 (Improvement of Fire Resistance and Impact Sound Insulation Performance for Timber Framed Floor by Installation of Isolated Ceiling)

  • 박주생;김세종;이상준
    • 한국가구학회지
    • /
    • 제24권4호
    • /
    • pp.426-432
    • /
    • 2013
  • Fire resistance and impact sound insulation tests were performed for a floor assembly, of which stiffness was reinforced by shortening the span of floor joists by installing glulam beam additionally in the middle or one thirds of the original span, and which an additional ceiling component was installed apart from floor structure. By applying the isolated ceiling, timber framed floor showed 1 hour of fire resistance even in case that dead load was increased by considering cement mortar layer for radiant floor heating. Insulation performance against light and heavy impact sound was improved significantly by applying the sound absorbing layer of big mass and high elasticity in addition to the stiffness improvement and isolated ceiling.

  • PDF

설치면 강성에 따른 드럼세탁기의 동특성 및 설계대책 (The Influence of the floor rigidity on front-loading washer installation and its vibrational behavior)

  • 위훈;정지덕
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.248-251
    • /
    • 2004
  • The vibrational behavior of a front load washing machine is heavily influenced by the floor stiffness on which the washing machine is installed. In case the floor stiffness is extremely low like a wooden floor (we call it a 'soft floor, S/F'), it is quite probable that a washer's rigid body mode exists in the operating frequency range. In this case, the outer frame vibration level would be very high, but the mitigation scheme is quite limited except the excitation force abatement by acquisition of the optimal inertia in the internal vibratory system and the diaphragm's stiffness with the minimum force transfer.

  • PDF

슬림 합성보 바닥시스템의 사용성 평가 (Serviceability Evaluation of Slim Composite Floor System)

  • 은희창
    • KIEAE Journal
    • /
    • 제8권6호
    • /
    • pp.63-70
    • /
    • 2008
  • Slim floor construction is becoming used throughout many countries. It combines the advantages of flat slab construction with significant inherent resistance to fire. The slim floor system with web openings leads to the reduction of its self-weight. Although the system has enough strength and stiffness, it is necessary to evaluate and improve the effects of dynamic vibration to be able to annoy the residents. Thus, this study evaluates the serviceability of vibration effects based on the dynamic test of five slim composite beams. Based on the experimental results, the initial stiffness and natural frequency of all specimens exhibit the similar trend regardless of the opening and the shape of cross section. The decrease in natural frequency is deeply related to the reduction in the stiffness of specimens and thus, it can be concluded that the damage of slim composite floor can be detected by the measurement of natural frequency instead of the load-carrying capacity and the stiffness.

완충재 종류에 따른 중량바닥충격음 저감특성 평가 (A Study on the Heavy-weight Floor Impact Sound Reduction Evaluation of Characteristics by Resilient Materials)

  • 김경우;양관섭;정진연;임정빈;정갑철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1145-1148
    • /
    • 2007
  • Resilient materials are generally used for the floating floors to reduce the floor impact sound. Dynamic stiffness of resilient material, which has the most to do with the floor impact sound reduction. The resilient materials available in Korea include EPS (Styrofoam), recycled urethane types, EVA (Ethylene Vinylacetate) foam rubber, foam PE (Polyethylene), glass fiber & rock wool, recycled tire, foam polypropylene, compressed polyester, and other synthetic materials. In this study, we tested floor impact sound reduction characteristic to a lot of kinds of resilient material. The result of test showed that the amount of the heavy-weight impact sound reduction appeared by being influenced from this dynamic stiffness of resilient material. The dynamic stiffness looked like between other resilient materials, a similar to the amount of the heavy-weight impact sound reduction was shown.

  • PDF

완충재 종류에 따른 경량바닥충격음 저감특성 평가 (Evaluation of the Light-weight Floor Impact Sound Reduction Characteristics by Types of Resilient Material)

  • 김경우;양관섭;정진연;임정빈;정갑철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.830-834
    • /
    • 2008
  • Resilient materials are generally used for the floating floors to reduce the floor impact sound. Dynamic stiffness of resilient material, which has the most to do with the floor impact sound reduction. The resilient materials available in Korea include EPS (Styrofoam), recycled urethane types, EVA (Ethylene Vinylacetate) foam rubber, foam PE (Polyethylene), glass fiber & rock wool, recycled tire, foam polypropylene, compressed polyester, and other synthetic materials. In this study, we tested floor impact sound reduction characteristic to a lot of kinds of resilient material. The result of test showed that the amount of the Light-weight impact sound reduction appeared by being influenced from this dynamic stiffness of resilient material. As the decreasing dynamic stiffness of resilient material, the impact sound reduction amount is increased, especially in the low frequency domain.

  • PDF