• Title/Summary/Keyword: floor finishing material

Search Result 71, Processing Time 0.025 seconds

Prediction of Concentration Decay of Volatile Organic Compounds from Ondol Floor and Furniture (주택에 설치한 온돌 마루 및 붙박이 가구에서 발생하는 휘발성유기화합물의 농도 감소 예측)

  • Cho, Hyun;Pang, Seung-Ki;Baik, Yong-Kyu;Sohn, Jang-Yeul
    • KIEAE Journal
    • /
    • v.5 no.1
    • /
    • pp.51-57
    • /
    • 2005
  • In this study, time-dependent concentration variations of VOCs from fixed furniture and Ondol floor widely used as finishing material of the floor were measured, and prediction equations were developed based on the measured results. VOCs were measured and analyzed based on EPA TO-17 and NIOSH 1500, 1501 method respectively, and GC/FID were used for the analysis of VOCs concentration. Measurements were carried out for 10 days after the installation of furniture and for 40 days after the installation of the floor in the residence constructed more than 10 years ago. In both case of floor and furniture installation, time-dependent concentration decay of VOCs can be properly converted into logarithmic scale. Especially in case of furniture, toluene showed the highest concentration and took longest time to decay. As a result of the prediction of VOCs concentration decay under different air change rate using estimated equations, concentration decay rate of indoor VOCs increased rapidly as the air change rate also increased.

Content analysis of advertised eco-interior products and materials (친환경 실내 디자인 마감재의 유형별 광고특성 연구)

  • Oh, So-Yeon;Kim, Kyu-Lee;Kwon, Hyun-Joo;Lee, Soo-Jin;Lee, Yeun-Sook
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2006.05a
    • /
    • pp.264-267
    • /
    • 2006
  • The purpose of this study is to examine the advertisements of eco-friendly interior products and finishing materials in 3 interior design magazines which have been published for 4 years since 2002: to identify specific types of the products and materials that consumers can choose and to analyze their special ingredients which have functions and effectiveness related to health. Literature review and content analysis on the advertisements were employed. The results are as follows: The amount of advertisements has been continuously increasing due to the public concerns on well-being and finishing material types absolutely took the greatest proportion (92.8%) among them. Floor coverings, wall papers, and paints are the big 3 materials in the finishing material advertisements. The frequently mentioned health-related ingredients in them were charcoal, natural jade, nanosilver, yellow soil and quartz porphyry, And their main functions were emission of negative ions and ultra infrared. However, it's not easy to find their scientific test results on health. Objective guidelines are needed for the right selection of interior products and materials to maintain healthy interior environment.

  • PDF

Effect of Pen Floor Condition Depending upon Housing Orientation on the PerFormance of Finishing Hanwoo Steers (우사의 향방에 따른 사육장 바닥면의 조건이 비육말기 거세한우의 생산성에 미치는 영향)

  • 김동균;정다운
    • Journal of Animal Environmental Science
    • /
    • v.10 no.1
    • /
    • pp.37-46
    • /
    • 2004
  • In order to investigate the effect of floor condition on the fattening performance of cattle, sixteen finishing Hanwoo steers of weighting 570kg were fed for 16 weeks to slaughter on two types of sawdust bedding pen oriented to the south(SP) and the north(NP) then obtained following results. The floor condition of SP roofed by transparent material was dry and flat during overall experimental period, whereas, that of NP roofed by solid slate was muddy and rough even in summer and fall, and then frozen in winter period resulted in interfering with the locomotion and resting behavior of steers. Average daily dry matter intake of steers was not different between tow treatments, however, the average daily gain of steers in NP and SP was 0.64kg and 0.75kg, respectively, meaning that gained 14.3% less for the NP group(p<0.05), accordingly, feed requirement(feed/gain) and TDN/gain increased by 15.9% and 15.5%, respectively. No significant differences were found in slaughter weight, carcass weight, dressing percentage, meat yield index and meat quality traits between two treatments. In conclusion, this study revealed that poor floor condition of feeding pen could decrease weight gain and feed efficiency of cattle by increasing energy consumption for locomotion and conductive energy loss while resting on the floor surface. These results indicates that housing orientation of cattle shed and the selection of roof material are important factors in beef cattle production.

  • PDF

Thermal Bridge and Heat Transfer Analysis for Each Part in Residential Building According to Construction of Wood-based Finishing Material (목질 마감재 구성에 따른 주거용 건축물 부위별 열교 및 전열성능 분석)

  • Seo, Jungki;Jeong, Su-Gwang;Kim, Sumin
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.3
    • /
    • pp.343-359
    • /
    • 2017
  • Many researches and policies have been carried out for saving energy in buildings. However, there are a few studies of thermal characteristics of wood-based materials that have been widely used as structural materials and finishing materials in buildings. In this study, thermal bridging areas were found to investigate thermal performance of residential building using non wood-based materials and wood-based materials. And heat transfer analysis of 16 case studies according to composition of structural materials and finishing materials was conducted. Also in this experiment, Physibel Trisco was used as the heat transfer analysis simulation tool, which conforms to the calculation method of ISO 10211. Analytical modeling was also carried out according to the ISO 10211, and the boundary temperature conditions were set at room temperature $20^{\circ}C$ and outdoor temperature $-11.3^{\circ}C$ (Seoul standard) according to the energy saving design standard in South Korea. Applied structures are classified according to the cases of concrete structure with non wood-based finishing materials, concrete structure with wood-based finishing materials and wood structure. Analyzed building elements were divided into a wall, a roof, an interlayer floor and a bottom floor. As a result, it can be confirmed that the thermal bridge of the concrete structure and wood structure were caused by the geometrical and material causes. In addition, the structural thermal bridge was caused in the discontinuity of the insulation in the concrete structure. Also it was confirmed that the linear heat transfer coefficient of the wall decreases when the wood-based materials are applied to the concrete structure.

The Effect of Aerated Concrete containing Foam Glass Aggregate on the Floor Impact Sound Insulation (발포유리 혼합기포 콘크리트의 바닥충격음 차단성능 영향에 관한 연구)

  • Yun, Chang-Yeon;Jeong, Jeong-Ho;Kim, Myung-Jun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.5
    • /
    • pp.414-422
    • /
    • 2013
  • As structure-borne sound, the floor impact sound is one of the serious noises in residential building. Most of heating system applied to the typical Korean residential building is floor heating system which is called ondol. The ondol usually consists of finishing material, mortar with heating coil, light-weight aerated concrete and reinforced concrete. This study focused on the isolation of heavy-weight impact sound and modification of mortar and light-weight aerated concrete. Specifically the glass foam aggregate was added on light-weight aerated concrete. Also, water-cement ratio and amount of cement on mortar were revised. The sound pressure level of heavy-weight impact was measured in reverberation chamber using both bang-machine and impact ball. The size of specimen was 1 m by 1 m. Substitution ratio of glass foam aggregate on light-weight aerated concrete shows relationship with heavy-weight impact sound pressure level. In addition, heavy-weight impact sound pressure level was decreased with increment of water-cement ratio and amount of cement on mortar.

Quality Control Techniques for Bare Concrete Floor Construction to Ensure Serviceability for Occupants (거주자 사용성 확보를 위한 콘크리트 맨바닥 시공 품질 관리 기법)

  • Mauk, Ji-wook;Choi, Kyung-suk;Kim, Jeong-jin;Seok, Won-kyun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.19-20
    • /
    • 2023
  • The pre-qualification system related to floor impact noise is considered ineffective, and thus, the introduction of a post-verification system is being prepared. This is because the performance, which was notarized in the qualification test due to various reasons, was not uniformly confirmed on building construction fields. Industry practitioners perceive that this is due to the influence of factors such as the flatness, levelness and/or thickness of the floor. However, it is very difficult to confirm such facts in a short period of time on the fields, and since the practical application of technology to measure and evaluate quantitatively and the establishment of a system are insufficient, it cannot be said to be a problem that can be brought to the surface. In fact, even when considering the conventional measurement of the dynamic modulus of elasticity, measurements are performed under controlled variables, such as placing a 200mm×200mm buffer material on a flat test-floor. However, in the fields, it is common to lay down larger productions(for example, 900mm×600mm) on the bare floor where significant variables are not controlled, and to construct finishing layers corresponding to the pre-qualified floor system without separately confirming the realization of the dynamic modulus of elasticity in the field conditions. In this study, spatial information of the bare floor on the field was measured and evaluated through a laser scanner. Technical methods for assessing the smoothness, flatness, and thickness of construction surfaces were reviewed, providing key insights for grading the quality of construction based on these criteria. Through further detailed and thorough investigations, it is expected that results suitable for practical application and systematization will be derived.

  • PDF

Preliminary Tests of Mortars Containing Magnetite as Fine Aggregate (자철석 혼입 모르터의 기초물성 연구)

  • Yoon, Sang Chun;Yang, Sung Chul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.3
    • /
    • pp.82-88
    • /
    • 2013
  • In this project a preliminary experimental research work was done to apply mortars containing magnetite as fine aggregates unto floor finishing materials in order to make indoor environment eco-friendly and to have noiseproof control between floors. Crushed magnetites were substituted as sands in the mix design with a range of 0, 20, 40, 60, 100%. First far-infrared radiation tests to determine emissivity and emission power were done in accordance with the KICM test standard and an outstanding result was obtained. Density and compressive strength test results also showed that as the substitution increases, test values increase in a linear trend. However dry shrinkage test results revealed that as the substitution increases, shrinkage strain also increases. To clearly seek a solution about this problem, more experimental works should be done on oncoming experimental program.

The Effect on the Granodiorite Suspension Coated Indoor Finishing Materials for Reduction of TVOC Emissions (실내 마감재료의 TVOC 방출 저감을 위한 화강섬록암 현탁액 도포효과)

  • Lee, Jong-Gyu;Kim, Ji-Hyun;Lee, Jae-Yong;Lee, Soo-Yong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.5
    • /
    • pp.93-99
    • /
    • 2008
  • The environment draws attention in the global community and a growing number of Koreans have interest in improving the quality of life, the importance of house environment has attracted the attention of the public. Against this backdrop, constructors have unveiled environmentally -friendly projects. However, they failed to establish people-oriented environment by being occupied with maximizing profitability through the improvement of brand image and caused sick house syndrome that has recently made controversy. In this regard, the study analyzed the mechanism of discharge of TVOC, one of the sick house syndrome-causing materials, that affects IAQ and its characteristics and examined the effect that granodiorite has on reduction of the discharge of TVOC in order to minimize damage. Experimental sample consisted of interior finishing materials frequently used in ceiling, wall and floor and adhesives used at a time of construction, and the TVOC of building materials was measured through the use of septum bottle unlike In the existing chamber method. Measures to counter the sick house syndrome were suggested by reducing the possible damage from the stage of selection of building material and by figuring out the effect that the granodiorite has on reduction of the discharge of TVOC.

A Study on the Interrelation of Material and Space in Modern Interior Design (현대 실내디자인에 있어 재료와 공간의 상호관계성에 관한 연구)

  • 이상협;김문덕
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2003.05a
    • /
    • pp.187-191
    • /
    • 2003
  • Modern interior design is expanding diversely, with the rapid development of technology and change of era. The basic of interior space that is rapidly changing consists of floor, wall and ceiling, and these are formed by materials, materials for structure or finishing materials. In the modern interior space, materials are utilized to present an atmosphere that meets the trend of the dissolution of post-modernism and the trend of minimalism. Accordingly, in this study, designers who take serious view on the relation of space and material, and the relation focusing on completed works, in modern interior design were investigated. The interrelation of the representation of each material, organic space, minimal space, and the space of Oriental fusion style were investigated through the works of modern interior designers, such as Karim Rashid and Ettore Sottsass.

  • PDF

The effect of dynamic property of absorbing sheet on the amplification of heavy weight floor impact noise (완충재의 동특성에 따른 중량충격음 증폭에 관한 해석적 연구)

  • Hwang, J.S.;Moon, D.H.;Park, H.G.;Hong, S.G.;Hong, Geon-Ho;Lim, J.H.;Kim, Y.N.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.05a
    • /
    • pp.527-528
    • /
    • 2010
  • Previous experimental results performed by many researchers for a couple of decades in South Korea have shown that an absorbing sheet inserted in a conventional floating slab system for thermal insulation or vibration absorption may amplify the vibration of the slab system at specific frequency ranges depending on the material properties of the sheet. The amplified vibration, consequently, results in the heavy weight floor impact noise exceeding the sound level limit for an apartment house, 50dB. In this study, the amplification mechanism is examined through numerical analysis and a new slab system is proposed to reduce the amplification and control the noise. The new slab system consists of studs connecting the base slab and upper concrete finishing yielding the dramatically increased stiffness of the slab. The numerical simulation is performed to investigate the effect of the slab system with studs on the vibration and noise control. The results show that the performance of the slab is sensitive to the number and location of studs, and the heavy weight floor impact noise can be reduced up to 6-7dB compared to the conventional slab system at the optimal stud location.

  • PDF