• 제목/요약/키워드: floor dust

검색결과 38건 처리시간 0.025초

집먼지진드기 항원량과 알레르기 자각증상의 계절적 변화 - 알레르기 천식환자가구와 정상가구의 비교 - (Seasons Variation of House Dust Mites Allergen and Perceived Allergic Symptoms)

  • 김용순;박지원;송영신
    • 한국보건간호학회지
    • /
    • 제16권1호
    • /
    • pp.30-44
    • /
    • 2002
  • The purpose of this study were to identify seasons variation of house dust mites allergen and perceived allergic symptom. The subjects were consisted of 29 family with allergy patients and 34 family without allergy patients. Perceived allergic symptoms were accessed and house dust was sampled from beds, floor of bedroom, kitchen and livingroom in spring(August), summer (July), fall(October) and winter(January) and tested using two-site ELISA. The results were as follows; 1) In all family, amount of house dust mites allergen(Der fI) of livingroom floor was the highest in summer$(4.73{\mu}g/1g\;of\;dust)$, and then fall$4.67{\mu}g/1g\;of\;dust)$, winter$(3.94{\mu}g/1g\;of\;dust)$, spring$(1.73{\mu}g/1g\;of\;dust)$. 2) In family with allergy patients, amount of house dust mites allergen(Der fI) of bedroom floor was highest in fall $(9.75{\mu}g/1g\;of\;dust)$. 3) In family with allergy patients, amount of house dust mites allergen(Der fI) of mattress was highest in fall$(8.23{\mu}g/1g\;of\;dust)$. 4) Perceived allergic symptom scores of family with allergy patients were higher than family without allergy patients in all seasons. In family without allergy patients, perceived allergic symptom scores was the highest in spring(4.29) and perceived allergic symptom scores of family with patients was the highest in winter(2.49). 5) The relationship of house dust mites allergen and perceived allergic symptom scores were positively related (r=.941, p=.000). Perceived allergic symptoms were correlated with amount of house dust mites allergen, That is, perceived allergic symptoms were became worse by house dust mites allergen. So House dust mites allergen reducing strategies and intervention should be recommended in further study.

  • PDF

일부 초등학교 바닥 먼지내 포함하고 있는 유해물질 성분에 대한 현장 평가 (On-site Investigation of Hazardous Substances in Floor Dust of Several Primary Schools)

  • 김기연;김현태;이권섭
    • 한국산업보건학회지
    • /
    • 제24권4호
    • /
    • pp.478-483
    • /
    • 2014
  • Objectives: The main objective of this study is to assess the levels of hazardous substances in floor dust in primary schools located in the city of Busan in Korea. Materials and Methods: An on-site investigation of three primary schools was performed between April and May 2013. The hazardous substances measured in this study were 14 heavy metals (Cu, Fe, Pb, Mn, Ni, Zn, Cr, Cd, As, Al, Sn, Co, Mo and Si) and the biological agents were bacteria, fungi and endotoxin). Results: Among the heavy metals, Cd, Co, Pb and Cr were not detected in the floor dust from the three primary schools. The mean levels of other heavy metals were as follows: $20({\pm}10)ng/cm^2$ for As, $30({\pm}20)ng/cm^2$ for Al, $5({\pm}4)ng/cm^2$ for Sn, $20({\pm}20)ng/cm^2$ for Mo, $1,340({\pm}620)ng/cm^2$ for Si, $110({\pm}100)ng/cm^2$ for Cu, $240({\pm}50)ng/cm^2$ for Fe, $30({\pm}30)ng/cm^2$ for Mn, $10({\pm}10)ng/cm^2$ for Ni, and $50({\pm}30)ng/cm^2$ for Zn. It was found that mean concentrations of bacteria, fungi and endotoxin in the floor dust of primary schools were $4.7{\time}10^7({\pm}2.2{\time}10^7)cfu/cm^2$, $6.3{\time}10^6({\pm}6.4{\time}10^6)cfu/cm^2$, and $8,140({\pm}5,801)EU/cm^2$, respectively. The predominant species identified in the floor dust of the primary schools were Pseudomonas spp. for bacteria and Penicillium spp.,Cladosporidium spp.,and Aspergillus spp. for fungi, which would be somewhat similar to the microbial distribution pattern of other general environments. Conclusions: Based on the results obtained from this study, the levels of heavy metals, microbes and endotoxin distributed in the floor dust of primary school were higher than those reported for other general facilities. Thus, preventive measures should be prepared for the health care of children.

어린이가 생활하는 실내공간의 바닥먼지 중 프탈레이트 농도와 노출수준: DEHP를 중심으로 (Concentrations and Exposure Levels via Intake of Phthalates in Dust Deposits in Indoor Children's Living Areas: Focusing on DEHP)

  • 전성호;김경희;최재욱
    • 한국환경보건학회지
    • /
    • 제48권1호
    • /
    • pp.52-58
    • /
    • 2022
  • Background: Few studies have evaluated the exposure to phthalates via inhalation of floor dust in children's living areas. Objectives: This study evaluated the concentration and exposure level of phthalates emitted from indoor floor dust in children's living areas. Methods: This study utilized the results of a survey conducted by the Ministry of Environment in 2019. Indoor dust was collected from 150 households with children aged 3~7 and 67 daycare centers or local children's centers by using vacuum cleaners. It was analyzed by gas chromatography mass spectrometry. Six types of phthalates were analyzed: Bis (2-ethylhexyl) phthalate (DEHP), Dibutyl phthalate (DBP), Benzyl butyl phthalate (BBP), Di-N-octyl phthalate (DNOP), Diisononyl phthalate (DINP), Di -isodecyl phthalate (DIDP). Results: The medians of DEHP concentrations were 1,028 and 1,937 mg/kg in homes and daycare centers, respectively. The median and maximum values of daily intake were calculated by applying the median and 95th percentile values (the upper 5% of the total concentration) in dust measured in the homes. The DEHP median value was 1.6 ㎍/kg/bw/day, and a maximum A value of 7.8 ㎍/kg/bw/day was calculated. When the childcare center values were applied, the median daily intake of DEHP was 3.1 ㎍/kg/bw/day and the maximum value was 29.2 ㎍/kg/bw/day. As a result of calculating the daily intake by integrating the values of home and childcare facilities, the median and maximum values of daily intake were 1.9 and 10.9 ㎍/kg/bw/day, respectively. Conclusions: This study derives phthalate concentrations among the floor dust in homes and childcare facilities where children mainly spend time, and suggests their intake of phthalates through this. In particular, it was newly suggested that the phthalate concentrations in homes and childcare facilities are different, resulting in differences in intake.

Occurrence of Phthalates in Indoor Dust from Children's Facilities and Apartments in Seoul

  • Kim, Ho-Hyun;Lim, Young-Wook;Yang, Ji-Yeon;Shin, Dong-Chun
    • 한국대기환경학회지
    • /
    • 제25권5호
    • /
    • pp.382-391
    • /
    • 2009
  • The aim of the study was to assess the levels in typical central borough of phthalate exposure by monitoring children's facilities (19 kindergartens and 21 elementary schools) and households (17 old apartments and 22 new apartments) via sampling indoor floor dust. A vacuum cleaner specifically prepared for sampling dust was attached to a filter of a vacuum cleaner dust collecting container. During the sample preparation process, containers made of glass were used and analysis was performed using GC-MSD. The mean concentration of DEHP was $412{\mu}g/g$, DnBP was $24{\mu}g/g$, and BBzP was $10{\mu}g/g$ dust. The indoor characteristics including floor, wall materials, years after construction, water leakage history for the past three years, and ventilation were also examined to categorize phthalate esters from the dust samples. From the flooring and wallpaper materials of kindergartens and elementary schools, DEHP in the dust sample appeared at a statistically significant level (p<0.05) when PVC materials were present. DEHP in the indoor dust also increased significantly (p<0.01) during the construction period. The daily intake of DEHP measured from indoor dust was 0.08~$19.7{\mu}g/kg/day$ for children and 0.02~$1.1{\mu}g/kg/day$ for adults (women). The results clearly revealed that phthalate exposure is greater in children than in adults (women) due to the indoor dust.

먼지 피해의 환경분쟁조정 사례 분석과 배상액 산정안 제언 (Dispute Mediation Cases and Suggestions for Calculating Compensation for Dust Damage)

  • 박정호
    • 한국환경과학회지
    • /
    • 제32권10호
    • /
    • pp.693-701
    • /
    • 2023
  • In this study, we analyzed 82 dust damage dispute mediation cases over the past 5 years and evaluated cases where the probability of damage was verified through dust concentration measurement, modeling prediction, and chemical composition analysis. The cause of dust damage was a construction site, which accounted for most of the damage (97%), and was closely related to the distance from the construction site, total floor area of the construction site, and construction duration. Compensation was decided in only 33% of dust damage cases, and in only 6% (five cases) were damages determined using scientific techniques such as dust measurement, and forecasting. The main criteria for determining compensation were whether administrative measures were taken and evidence of damage in the form of videos and photos. In the future, measuring or model for the amount of dust damage is necessary to determine whether the limit has been exceeded and to revise the standard for calculating compensation through various lines of evidence of dust damage.

바닥난방이 육계의 사육환경 및 생산성에 미치는 영향 (Effect of Floor Heating System on Housing Environment and Performance in Broiler Production)

  • 최희철;이덕수;서옥석;한정대;강희설;권두중;곽정훈;강보석;장병귀
    • 한국가금학회지
    • /
    • 제26권3호
    • /
    • pp.189-193
    • /
    • 1999
  • This experiment was conducted to investigate the effect of floor heating system on housing environment and performance in broiler production. PVC heating pipes(in 25cm spacing) were covered with concrete under the litter. Floor heating system was compared with conventional direct heating system. Each treatment had two replicates of 110 birds each. Litter moisture content was significantly reduced in floor heating system than conventional direct heating system(P〈0.05). Dust concentration was higher in floor heating system because of low litter moisture content. CO$_2$concentration was 2,900ppm and 1,500ppm on the direct heating system and floor heating system, respectively at the age of 1 week. Body weight was significantly higher in floor heating system at 7 weeks of age(P〈0.05). The results of the trial show that floor heating was useful heating system for broiler production.

  • PDF

모의 실험주택 모니터링 결과를 활용한 실내공기 및 바닥먼지 중 Di(2-ethyl-hexyl) phthalate (DEHP)의 이론적 총량 비율 산출 (Calculation of the Theoretical Total Amount Ratio of Di(2-ethyl-hexyl) Phthalate in Indoor Air and Floor Dust in a Test House)

  • 천사호;이가원;김승중;정승표;강다영;김기태
    • 한국환경보건학회지
    • /
    • 제49권6호
    • /
    • pp.324-333
    • /
    • 2023
  • Background: Human exposure to phthalates in indoor environments occurs via dermal absorption, oral ingestion of indoor dust, and inhalation of indoor air. However, systematic studies to investigate the exposure rate to phthalates among the three exposure routes in indoor environments are currently limited. Objectives: A theoretical exposure ratio between inhalation and oral exposure was calculated based on the total amount of di(2-ethyl-hexyl) phthalate (DEHP) emitted into indoor air and deposited into floor dust in a test house. Methods: Flooring and wallpaper containing DEHP were installed in a test house and the concentration of DEHP in both indoor air and floor dust were monitored for five months. Based on the measured DEHP concentrations, the theoretical total amount ratio of DEHP that could be exposed through inhalation and oral ingestion was calculated. Results: Considering the period of operation in the test house, the theoretical total amount of DEHP through inhalation and oral ingestion exposures in the entire test house space was calculated to be 0.014 mg and 5.5 mg, respectively. The exposure ratio of the two routes between inhalation and oral exposure corresponding to the total DEHP amount in flooring and wallpaper was 6.0×10-7% and 2.3×10-4%, indicating that theoretical oral exposure to DEHP is approximately 380 times higher than inhalation. Conclusions: Monitoring results from a test house has shown that oral exposure is the main exposure route for DEHP in indoor environments. The experimental design employed in this study and theoretical exposure ratio obtained can be applied to investigate actual exposure to DEHP and to determine the exposure characteristics of various types of semi-volatile organic compounds.

Correlation of Air Pollutants and Thermal Environment Factors in a Confined Pig House in Winter

  • Choi, Hong L.;Kim, Ki Y.;Kim, Hyunook
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제18권4호
    • /
    • pp.574-579
    • /
    • 2005
  • Optimal management of indoor air quality in a confined pig house, especially in winter, is indispensable for preventing infectious respiratory disease to workers and animals. This study was performed to elucidate the correlation of aerial contaminants and climate factors in a confinement. It was observed that indoor air contaminants ion in the confinement was the highest at 2:00-5:00 pm in a day, followed by 8:00-11:00 pm and 8:00-11:00 am. This was attributed to the increase of pig activities in the afternoon. The concentration of total dust and total airborne bacteria was found to have a significant correlation with temperature and relative humidity (p<0.05). Correlation of total dust and total airborne bacteria, total dust and ammonia, and total dust and odor were shown statistically significant at 95% confidence level. In conclusion, temperature and total dust concentration correlated significantly with all the parameters except for hydrogen sulfide ($H_2S$). This could be explained by the fact the dryness of pig feces by increase of interior temperature and resuspension of feed deposited on the floor by the pig activity, resulted in high generation of dust which adsorbed and carried the airborne bacteria and odor compounds in a confined pig house. It was proved that the adsorptive capacity of dust with ammonia ($NH_3$) was higher than that with hydrogen sulfide ($H_2S$).

제올라이트와 석분을 이용한 고성능 바닥재의 개발에 관한 기초적 연구 (The Fundamental study on Development of high performance Floor materials using the Zeolite and Stone dust)

  • 류희정;임병호;최영준;이승조;김태곤;박정민;김화중
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.785-790
    • /
    • 1997
  • In domestic, it is not a little results to use natural mineral, stone and sludge as a construction materials. Accordingly, it is required to study for higher application from of resources these materials in its economic and environmental aspects. So, the purpose of this study is to develop the excellent construction materials, a as compare with existing floor materials in material capacity and economic aspects, using natural zeolite, stone dust and sludge. In this viewpoint, this paper investigated to the required capacity such as, compressive strength, bending strength and absorption according to experiment.

  • PDF

강화폴리에스테르튜브(XL 튜브)에 진동형 히트 파이프를 결합한 고성능 난방 패널의 성능에 관한 연구 (A Study on the highly efficient ondol system combined the strengthen polyethylene pipe with pulsating heat pipe)

  • 김창희;김종수;우재호;공상운
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.578-583
    • /
    • 2008
  • Korea which has change of clear season is using unique heater by the name of On-dol being invented since ancient times. Floor-heating device has no radiator, and generates no noise and dust. It can obtain satisfied heating sense than other heating system in low room temperature. And also it is a pleasant system that equals bottom and top temperature in a room. The purpose of this study is to develop the Floor-heating device using pulsating heat pipe. It propose floor-heating device using pulsating heat pipe of the dry process which alternative polyethylene pipe(low XL pipe) that is used widely to existent floor heating system and produce pilot Experiment and analyzed operation condition and performance of most suitable. In this study, main purpose is to develop floor-heating system using pulsating heat pipe by finding an optimum working condition according to changing ratio and evaluating a performance.

  • PDF