• 제목/요약/키워드: flexural test

검색결과 1,915건 처리시간 0.025초

Effect of length and content of steel fibers on the flexural and impact performance of self-compacting cementitious composite panels

  • Denise-Penelope N. Kontoni;Behnaz Jahangiri;Ahmad Dalvand;Mozafar Shokri-Rad
    • Advances in concrete construction
    • /
    • 제15권1호
    • /
    • pp.23-39
    • /
    • 2023
  • One of the important problems of concrete placing is the concrete compaction, which can affect the strength, durability and apparent quality of the hardened concrete. Therefore, vibrating operations might be accompanied by much noise and the need for training the involved workers, while inappropriate functioning can result in many problems. One of the most important methods to solve these problems is to utilize self-compacting cementitious composites instead of the normal concrete. Due to their benefits of these new materials, such as high tensile, compressive, and flexural strength, have drawn the researchers' attention to this type of cementitious composite more than ever. In this experimental investigation, six mixing designs were selected as a base to acquire the best mechanical properties. Moreover, forty-eight rectangular composite panels with dimensions of 300 mm × 400 mm and two thickness values of 30 mm and 50 mm were cast and tested to compare the flexural and impact energy absorption. Steel fibers with volume fractions of 0%, 0.5% and 1% and with lengths of 25 mm and 50 mm were imposed in order to prepare the required cement composites. In this research, the composite panels with two thicknesses of 30 mm and 50 mm, classified into 12 different groups, were cast and tested under three-point flexural bending and repeated drop weight impact test, respectively. Also, the examination and comparison of flexural energy absorption with impact energy absorption were one of the other aims of this research. The obtained results showed that the addition of fibers of longer length improved the mechanical properties of specimens. On the other hand, the findings of the flexural and impact test on the self-compacting composite panels indicated a stronger influence of the long-length fibers.

강섬유 보강 초고강도 콘크리트 보의 휨강도 예측기법의 제안 (Prediction of Flexural Capacity of Steel Fiber-Reinforced Ultra High Strength Concrete Beams)

  • 양인환;조창빈
    • 대한토목학회논문집
    • /
    • 제30권3A호
    • /
    • pp.317-328
    • /
    • 2010
  • 이 연구에서는 강섬유보강 초고강도 콘크리트 보의 휨강도를 산정하기 위한 실제적인 기법을 제시하였다. 14개의 보 부재에 대해 휨실험을 수행하여 휨거동 특성을 분석하였으며, 실험결과를 기존의 설계기준 및 제안기법에 의한 예측결과와 비교 분석하였다. ACI 544 위원회의 휨강도 제안식에 의한 예측값은 실험값을 과소평가하고 있으며, 이는 인장응력블록을 너무 작게 산정하기 때문이다. 인장응력블록을 정밀하게 모델링하기 위하여 노치를 갖는 프리즘 시편의 3점 휨인장실험자료의 역해석을 수행하였으며, 역해석을 통해 산정한 인장연화곡선을 인장응력블록 모델링에 적용하였다. 휨강도 실험값에 대한 제안기법에 의한 예측값의 비는 0.98~1.14를 나타내고 있다. 따라서, 이 연구에서의 제안기법은 강섬유보강 초고강도 콘크리트 보의 휨강도를 더욱 정확하게 예측할 수 있다고 판단된다.

재하된 H형강 휨재의 열응력해석을 이용한 한계온도 산정 (Calculation of Limit Temperature on H-Beam Flexural Member Through the Thermal Stress Analysis under the Lateral Load)

  • 윤성기;이치형;구본훈
    • 한국강구조학회 논문집
    • /
    • 제27권4호
    • /
    • pp.387-397
    • /
    • 2015
  • 국내의 내화성능평가는 대부분 사양적설계 방법인 품질시험을 통해 이뤄지고 있다. 하지만 시험 특성상 많은 비용과 시간을 요구하며 다양한 건축구조에 대한 내화성능평가에는 어려움이 많다. 따라서 본연구에서는 성능적 설계를 위한 연구로 유한요소 구조해석 프로그램인 ABAQUS를 사용해 H형강 휨재를 대상으로 변수에 따른 열응력 해석을 통해 내화성능을 검토하며, 하중비별 한계온도를 제안한다.

실험자료를 기반한 국내 원형단면 철근콘크리트 휨교각의 손상수준 별 횡변위비 산정 (Estimation of Drift Ratio by Damage Level for Flexural RC Piers With Circular Cross-Section Based on Experimental Data in Korea)

  • 남현웅;홍기증;김익현
    • 한국지진공학회논문집
    • /
    • 제26권6호
    • /
    • pp.255-265
    • /
    • 2022
  • In order to determine fragility curves, the limit state of piers for each damage level is suggested in this paper based on the previous test results in Korea, including our test results. In previous studies, the quantitative measures for damage levels of piers have been represented by curvature ductility, lateral drift ratio, or displacement ductility. These measures are transformed to lateral drift ratios of piers for consistency, and the transformed values are compared and verified with our push-over test results for flexural RC piers with a circular cross-section. The test specimens are categorized concerning the number of lap-splices in the plastic hinge region and whether seismic design codes are satisfied or not. Based on the collected test results in Korea, including ours, the lateral drift ratio for each pier damage level is suggested.

외부철판이 사용된 DH Beam의 휨거동에 대한 실험 및 비선형해석 (Experiment and Nonlinear Analysis of DH Beams with Steel Form)

  • 문정호;오영훈
    • 콘크리트학회논문집
    • /
    • 제26권2호
    • /
    • pp.171-179
    • /
    • 2014
  • 이 연구는 DH beam의 구조성능을 평가하는 것을 목적으로 하였다. DH beam을 사용하는 DH 공법은 얇은 철판을 성형하여 거푸집 및 구조적 역할을 할 수 있는 철판을 철근과 함께 공장에서 선조립하여 현장으로 반입하여 콘크리트를 타설하는 공법이다. 이 때 DH 판이 거푸집 역할 뿐 아니라 휨강도에 기여할 것으로 여겨져서 이 연구에서는 DH 판의 휨강도 기여도를 평가하고자 하였다. 총 5개의 실험체를 대상으로 실험 및 해석적 연구를 수행하였다. 실험체는 2개의 정모멘트 실험체, 2개의 부모멘트 실험체, 그리고 1개의 RC 실험체로 구성되었다. RC 실험체는 DH beam과 비교를 목적으로 제작하였다. DH beam에 대한 실험 결과는 휨강도를 산정하는 설계식 그리고 RC 실험체에 대한 실험 결과 등과 비교를 통하여 DH beam은 철판이 항복하면서 충분히 휨강도에 기여하고 있음을 알 수 있었다. 그리고 비선형 구조해석에서는 두 개의 실험체에 대하여 DH 판이 있는 경우와 없는 경우를 대상으로 휨강도, 콘크리트의 주인장변형률, 그리고 철근의 응력을 비교하였으며, 해석에서도 DH 판이 휨강도에 충분히 기여함을 알 수 있었다. 이상과 같은 실험 및 해석적 연구의 결과 DH beam의 철판은 콘크리트와 합성단면을 형성하여 충분한 휨강도를 갖는 것으로 보였다.

Effects of relining materials on the flexural strength of relined thermoplastic denture base resins

  • Sun, Yunhan;Song, So-Yeon;Lee, Ki-Sun;Park, Jin-Hong;Ryu, Jae-Jun;Lee, Jeong-Yol
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권5호
    • /
    • pp.361-366
    • /
    • 2018
  • PURPOSE. The aim of this study was to evaluate the effects of relining materials on the flexural strength of relined thermoplastic denture base resins (TDBRs). MATERIALS AND METHODS. For shear bond strength testing, 120 specimens were fabricated using four TDBRs (EstheShot-Bright, Acrytone, Valplast, Weldenz) that were bonded with three autopolymerizing denture relining resins (ADRRs: Vertex Self-Curing, Tokuyama Rebase, Ufi Gel Hard) with a bond area of 6.0 mm in diameter and were assigned to each group (n=10). For flexural strength testing, 120 specimens measuring $64.0{\times}10.0{\times}3.3mm$ (ISO-1567:1999) were fabricated using four TDBRs and three ADRRs and were assigned to each group (n=10). The thickness of the specimens measured 2.0 mm of TDBR and 1.3 mm of ADRR. Forty specimens using four TDBRs and 30 specimens using ADRRs served as the control. All specimens were tested on a universal testing machine. For statistical analysis, Analysis of variance (ANOVA) with Tukey's test as post hoc and Spearman's correlation coefficient analysis (P=.05) were performed. RESULTS. Acry-Tone showed the highest shear bond strength, while Weldenz demonstrated the lowest bond strength between TDBR and ADRRs compared to other groups. EstheShot-Bright exhibited the highest flexural strength, while Weldenz showed the lowest flexural strength. Relined EstheShot-Bright demonstrated the highest flexural strength and relined Weldenz exhibited the lowest flexural strength (P<.05). Flexural strength of TDBRs (P=.001) and shear bond strength (P=.013) exhibited a positive correlation with the flexural strength of relined TDBRs. CONCLUSION. The flexural strength of relined TDBRs was affected by the flexural strength of the original denture base resins and bond strength between denture base resins and relining materials.

시험방법에 따른 신ㆍ구 콘크리트의 부착강도 특성 (Characteristics of Bond Strength with Measuring Methods of Concrete)

  • 장흥균;김성환;홍창우;윤경구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.597-600
    • /
    • 2003
  • The development and maintenance of a sound bond are an essential requirements of concrete repair and replacement. The bond property of a bonded overlay to its substrate concrete during the lifetime is one of the most important performance requirements which should be quantified. A standard or a verified bond strength measurement method is required at field for screening, selecting materials and quality control for overlay or repair materials. This study compares the nipple pipe direct tensile test, flexural adhesion test, and core pull-off test with their test results. Substantial differences in the failure stresses of three test methods were attributed to their different geometries and loading conditions. From these comparison and investigation, core pull-off test was relatively good because the coefficient of variation values were about 2%. It would be suitable for use in-situ because of its simplicity and accuracy.

  • PDF

Experimental and microstructural evaluation on mechanical properties of sisal fibre reinforced bio-composites

  • Kumar, B. Ravi;Hariharan, S.S.
    • Steel and Composite Structures
    • /
    • 제33권2호
    • /
    • pp.299-306
    • /
    • 2019
  • The natural fibre composites are termed as bio-composites. They have shown a promising replacement to the current carbon/glass fibre reinforced composites as environmental friendly materials in specific applications. Natural fibre reinforced composites are potential materials for various engineering applications in automobile, railways, building and Aerospace industry. The natural fibre selected to fabricate the composite material is plant-based fibre e.g., sisal fibre. Sisal fibre is a suitable reinforcement for use in composites on account of its low density, high specific strength, and high hardness. Epoxy is a thermosetting polymer which is used as a resin in natural fibre reinforced composites. Hand lay-up technique was used to fabricate the composites by reinforcing sisal fibres into the epoxy matrix. Composites were prepared with the unidirectional alignment of sisal fibres. Test specimens with different fibre orientations were prepared. The fabricated composites were tested for mechanical properties. Impact test, tensile test, flexural test, hardness test, compression test, and thermal test of composites had been conducted to assess its suitability in industrial applications. Scanning electron microscopy (SEM) test revealed the microstructural information of the fractured surface of composites.

폴리머 콘크리트 샌드위치 패널의 휨크리이트 특성 (Flexural Creep Properties of Sandwich Panels with Polymer Concrete Facings)

  • 연규석;김광우;함형길;김관호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1995년도 봄 학술발표회 논문집
    • /
    • pp.55-59
    • /
    • 1995
  • This study was experimentally carried out to evaluate flexural creep properties of sandwich panels with polymer concrete facings. Specimen was made using polymer concrete facing and polyestyrene form core that has an excellent insulation capacity. Test results showed that, in 90 days of loading, the flexural creep was 1/292 under 40% of stresslevel and 1/780 under 60% stress level.

  • PDF

순수휨 구간내 스터럽이 보강된 고강도 콘크리트 보의 휨거동 연구 (Flexural Behavior of High-Strength Concrete Beams with Confinement in Pure Bending Zone)

  • 장일영;박훈규;황규철;남성현
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.959-964
    • /
    • 2002
  • The purpose of this study is to establish flexural behavior of high-strength concrete by means of both theoretical approach and experimental analysis of beams in which confinement stirrups have been introduced into pure bending zone. The experiment was carried out on full-scale high-strength reinforced concrete beams whose compressive strengths are 400 and 700kgf/cm$^2$, and confined with rectangular closed stirrups. The test results are reviewed in terms of flexural capacity and ductility.

  • PDF