• Title/Summary/Keyword: flaw

Search Result 539, Processing Time 0.026 seconds

Side-Channel Cryptanalysis on Stream Cipher HC-128 for Mobile Ad-Hoc Network Environments (이동 Ad-Hoc 네트워크 환경에 적합한 스트림 암호 HC-128의 부채널 안전성 분석)

  • Bae, KiSeok;Park, YoungHo;Moon, SangJae
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.17 no.6
    • /
    • pp.11-17
    • /
    • 2012
  • The HC-128 stram cipher which selected for the final eSTREAM portfolio is suitable for mobile Ad-Hoc network environments because of the ability of high-speed encryption in restricted memory space. In this paper, we analyzed the vulnerability of side channel analysis attack on HC-128 stream cipher. At the first, we explain a flaw of previous theoretical analysis result which defined the complexity of side-channel attack of HC-128 stream cipher as 'low' and then re-evaluate the security against side-channel attack by estimating the concrete complexity for recovering the secret key. As a result, HC-128 stream cipher is relatively secure against side-channel attack since recovering the secret key have $2^{65}$ computation complexity which is higher than other stream cipher's one.

Comparison of Non-Destructive Testing Images using $^{192}Ir$ and $^{75}Se$ with Computed Radiography System (Computed Radiography 시스템에 $^{192}Ir$$^{75}Se$ 동위원소를 적용하여 촬영한 비파괴검사 영상 비교)

  • Kang, Sang-Mook;Chol, Chang-Il;Lee, Seung-Kyu;Park, Sang-Ki;Kim, Yong-Kyun
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.1
    • /
    • pp.26-33
    • /
    • 2010
  • A computed Radiography (CR) system by use of reusable Image Plate (IP) offers a convenient and reliable way to replace a conventional film-screen system for NDT (non-destructive testing) field. The quality of a radiography to detect a defect of welded objects depends on the procedure embracing several factors such as measurement conditions, image plate type/class, radiation energy, radiation type, and source to image plate distance. Also, the ability of images to detect a flaw reduces with increasing object thickness. In the study, the properties of gamma ray source were summarized for NDT field and inspection images of CR image system manufactured by FUJI were acquired using $^{75}Se$ and $^{192}Ir$ with welded objects. We analyzed the gray scale of hole defect image by using XCAP image processing program and calculated the image contrast and SNR in definition. Also the sesitivities of image quality indicator(IQI) were calculated for hot and cooling tube image of $^{75}Se$ and $^{192}Ir$.

Mechanical Behavior of Directionally Solicified (Y2O3)ZrO2/Al2O3 Eurtctic Fibers

  • Park, Deok-Yong;Yang, Jenn-Ming
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • The microstructural features and mechanical behavior of directionally solidified $(Y_2O_3)ZrO_2/Al_2O_3$ eutectic fibers after extended beat treatment in oxidizing environment were investigated. The fiber was grown continuously by an Edge-defined Film-fed Growth (EFG) technique. The microstructure was characterized using X-Ray Diffraction (XRD) and Scanning Electron Microscopy(SEM). The microstructure of the fiber in the as-fabricated state consists of highly oriented colonv and fine lamellar microstructure along the fiber axis. Tensile strength of the $(Y_2O_3)ZrO_2/Al_2O_3$ eutectic fiber remained unchanged with heat treatment at temperatures between $1200^{\circ}C$ and $1500^{\circ}C$ up to 300h. The weibulls modulus remained fairly constant after extended thermal exposure. The fracture toughness and crack propagation behavior were investigated. The fracture toughness ($K_{1C}$) of the $(Y_2O_3)ZrO_2/Al_2O_3$ eutectic fiber in the as-fabricated state were measured to be 3.6 ${\pm}$ 0.5 MPa${\cdot}m^{1/2}$ by an indentation technique and 2.2 ${\pm}$ 0.2 MPa${\cdot}m^{1/2}$ by assuming elliptical flaw of a semi-infinite solid, respectively. The $(Y_2O_3)ZrO_2/Al_2O_3$ eutectic fiber showed a radial (Palmqvist) crack type and exhibited an orthotropic crack growth behavior under 100 g load.

Effect of Alumina Particle Size on R-curve Behavior of (Y,Nb)-TZP/${Al_2}{O_3}$ Composites (알루미나 입도가 (Y,Nb)-TZP/${Al_2}{O_3}$ 복합체의 R-curve 거동에 미치는 영향)

  • Lee, Deuk-Yong;Kim, Dae-Joon;Kim, Bae-Yeon;Song, Yo-Seung
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.10
    • /
    • pp.936-941
    • /
    • 2001
  • The influence of the ${Al_2}{O_3}$ particle size on flaw tolerance of the $ZrO_2/{Al_2}{O_3}$ composites prepared by mixing 5.31 mol% ${Y_2}{O_3}$-4.45 mol% ${Nb_2}{O_5}$-90.31 mol% $ZrO_2$ and ${Al_2}{O_3}$ was investigated. The composites exhibited rising R-curve behavior and plateau fracture toughness of 7.9 and $8.8MPam^{1/2}$ for the additions of 20 vol% of 0.2 and $2.8{\mu}m$ ${Al_2}{O_3}$ particles, respectively. The difference in the fracture toughness resistance was attributed mainly to the grain size of tetragonal $ZrO_2$ phase in the composites, which scaled with the ${Al_2}{O_3}$ particle size.

  • PDF

Safety Margin Improvement Against Failure of Zr-2.5Nb Pressure Tube (Zr-2.5Nb압력관 파손에 대한 안전여유도 개선)

  • Jeong, Yong-Hwan;Kim, Young-Suk
    • Nuclear Engineering and Technology
    • /
    • v.27 no.5
    • /
    • pp.775-783
    • /
    • 1995
  • This study is to assess the effects of increasing wall thickness on the safety margin of pressure tube in operating and of lowering initial hydrogen concentration on the DHC growth in respect to the improvement of the reliability of pressure tube in CANDU reactors. The pressure tube with thicker wall of 5.2 mm shows much higher safety margin for flaw tolerance by 25% than the current 4.2mmm tube. The thicker pressure tubes have a great benefit in LBB assessment including the initial crack depth at which DHC occurs, the crack length at onset of leaking and the available time for action. The resistance for the pressure tube ballooning at LOCA accident is also increased with the thicker tube. The calculations for Heq concentration after 20 years of operation as a function of wall thickness and initial hydrogen concentration show that the 5.2 mm nil thickness tube with 5 ppm initial hydrogen concentration is the most resistant to DHC. with the lower initial hydrogen concentration, TSS temperature for the precipitation or hydride decreases and the crack growth during cooldown reduces.

  • PDF

Analysis on the design characteristics of blouse for silver generation in domestic and foreign (실버 세대를 위한 국내·외 블라우스에 나타난 디자인 특성 분석)

  • Kim, Da Eun;Lee, Kyoung Hee
    • The Research Journal of the Costume Culture
    • /
    • v.23 no.1
    • /
    • pp.32-44
    • /
    • 2015
  • Increasing of Korean old women's rate is demographic characteristics attributed an aging society, silver generation would lead to silver fashion market with steady competitiveness and interest in fashion. So the study attempts to use foundation material for silver's fashion design by analyzing design characteristics and processing development of design representative women's top. Selecting brand for collecting photo using study represents a mid- and premium-priced with reference Brand Yearbook. After selecting brand on domestic and foreign I have collected picture from Internet shopping mall and web-site of fashion brand, from October 2013 to July 2014, but I selected 840 pictures based on front poses for easy decision. In order to search design characteristics according to sort of silver blouse design on domestic and foreign. I have examined shape, color, pattern, fabric sensation, inside composition line and decoration with reference standard of analysis in preceding research. Data analysis method was conducted on analysis of frequency and cross analysis using SPSS statistical package 21.0. The conclusion of design characteristic according to type of blouse design for silver, H-silhouette in shirt blouse seems to fit in body transformation and expose silhouette with correcting the body flaw. Using soft material in T-shirt blouse they are able to conceal a body defect and express beautiful silhouette. By using detail in pullover shirt blouse and tunic blouse for point of design, it express glamour and luxurious. Most of blouse are printed various pattern, it would looks more gorgeous using pattern.

A Study on the Flow Control around a Circular Cylinder by Control rods (제어봉을 부착한 원형실린더 주위 유동제어에 관한 연구)

  • Gim, Ok-Sok;Lee, Gyoung-Woo;Cho, Dae-Hwan
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2007.05a
    • /
    • pp.169-174
    • /
    • 2007
  • The purpose in having a control rod an a buoy system is to control the motion of it. The system may be composed entirely af a single circular cylinder finder and a lang mooring anchor cable. A control rod has one function to perform in meeting its purpose, and that is to develop a control force in consequence of its orientation and movement relative to the water. The forces and moments generated as a result of the effects of mutual interference, then determine the stability characteristics of the body. In this paper, the study of control-rod-attached buoy's 2-dimensional section was accomplished. model tests and numerical simulations had been carried out with different diameters of control rods. and varying the Reynolds number $Re=5,000{\sim}25,000$ based an the cylinder diameter(D=50mm) to. predict the performance af the body and the 2 frame particle tracking method had been used to obtain the velocity distribution in the flaw field 50mm circular cylinder had been used during the whale experiments and measured results had been compared with each other.

  • PDF

A Study of Development of Diagnostic System for Web Application Vulnerabilities focused on Injection Flaws (Injection Flaws를 중심으로 한 웹 애플리케이션 취약점 진단시스템 개발)

  • Kim, Jeom-Goo;Noh, Si-Choon;Lee, Do-Hyeon
    • Convergence Security Journal
    • /
    • v.12 no.3
    • /
    • pp.99-106
    • /
    • 2012
  • Today, the typical web hacking attacks are cross-site scripting(XSS) attacks, injection vulnerabilities, malicious file execution and insecure direct object reference included. Web hacking security systems, access control solutions, access only to the web service and flow inside but do not control the packet. So you have been illegally modified to pass the packet even if the packet is considered as a unnormal packet. The defense system is to fail to appropriate controls. Therefore, in order to ensure a successful web services diagnostic system development is necessary. Web application diagnostic system is real and urgent need and alternative. The diagnostic system development process mu st be carried out step of established diagnostic systems, diagnostic scoping web system vulnerabilities, web application, analysis, security vulnerability assessment and selecting items. And diagnostic system as required by the web system environment using tools, programming languages, interfaces, parameters must be set.

A Development of an Array Guided Wave Ultrasonic Testing System for pipe inspection (배관 진단을 위한 배열형 유도초음파 검사시스템 개발)

  • Cho, Hyun-Joon;Lee, Dong-Hoon;Kang, To;Park, Jin-Ho;Han, Seong-Jin
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.5
    • /
    • pp.29-35
    • /
    • 2015
  • Pipes, commonly used in energy and petrochemical facilities, have various types of defects induced by diverse factors and this is often issued in NDE society. Ultrasonic guided wave inspection method are normally adopted to insure the healthiness of industry pipes. Recently, ultrasonic guided wave inspection is shifted to adopt arrayed probes and system. And here we developed an array guided wave ultrasonic testing system can adapt arrayed probes and focusing methods. In this paper, an array guided wave ultrasonic testing system is presented including a transmitting focusing technique and flaw signal level enhancement.

A Study on the Safety of Lifting Cable for Construction of Coastal Structures (항만건설을 위한 케이슨 들고리의 안전성에 관한 연구)

  • Kwak, Kae Hwan;Jang, Ki Woong;Kim, Jong Hyo
    • Journal of Korean Society of Steel Construction
    • /
    • v.10 no.1 s.34
    • /
    • pp.85-99
    • /
    • 1998
  • This paper describes an experimental study to examine collapse causes of the lifting cable due to brittle failure of an fitting anchor under the lifting works. Also, in this study an collapse mechanism that was obtained from stress analysis was compared with an actual collapse procedure. Fractographical analysis as well as chemical component test, tension test and Charpy V-Notch impact test for the fractured steel members were carried out. And then, its results were compared with that of normal steel members. Circumferential surface flaws were developed at internal facets of the fitting anchor before tensile stress occurred. Hence, a higher stress than nominal stress was occurred at flaws by stress concentration at the crack tip. Also, stress intensity factor of members increased by crack size of the potential flaws. Because the stress intensity factor at the crack tip was greater than critical values(fracture toughness), brittle fracture occurred under the lifting works. It is judged that the main collapse of the lifting cable is due to brittle fracture of the fitting anchor.

  • PDF