• 제목/요약/키워드: flat system

검색결과 1,658건 처리시간 0.024초

평판 유도발열체의 거리·주파수 가변특성에 관한 연구 (A study on the Distance and Frequency Variable Characteristics of Flat Plate Induction Heating Element)

  • 우형균;신대철
    • 조명전기설비학회논문지
    • /
    • 제27권6호
    • /
    • pp.68-74
    • /
    • 2013
  • Induction-heated system is innovative system which applied IH(Induction Heating) magnetic induction heating generated from induction-heated metallic package and high-frequency power circuit technique for thermal converse technique. In this occurs not burning, so that the working environment and deterioration of products can be improved. This technique is used high frequency inverter. By using high frequency inverter high frequency in the range of kHz can be made with conventional alternative current. In this contribution IGBT module is used for high frequency inverter. In this paper are discussed analysis of characteristics according to the each frequency and produced Flat plate induction heating system using 1.5kW-class half-bridge resonant inverter. In addition, operating characteristics of the system to changes in the distance between the coil and the heater, applications of system are also discussed.

Design of a Catadioptric System with Corrected Color Aberration and Flat Petzval Curvature Using a Graphically Symmetric Method

  • Lim, Tae-Yeon;Park, Sung-Chan
    • Current Optics and Photonics
    • /
    • 제2권4호
    • /
    • pp.324-331
    • /
    • 2018
  • This paper describes a symmetric method for determining a combination of element power and optical material to design a catadioptric system with corrected color aberration and flat Petzval curvature. To graphically obtain the solutions, a glass chart containing the Abbe number, the refractive index, and the optical power, which are closely related to these aberrations, is suggested. First, we recompose an optical system as a doublet of the specific lens and an equivalent single lens, and then locate both lenses on lines that are symmetric to each other on a glass chart, through changing the lens parameters effectively. Utilizing this method, an achromatic catadioptric system with flat Petzval curvature is obtained.

연약지반의 복합적 평가를 위한 전기비저항 탄성파 Flat DMT 장비 적용 (Application of Resistivity Seismic Flat Dilatometer (RSDMT) System for Multiple Evaluation of the Soft Soil Site)

  • 방은석;김영상;박삼규;김동수
    • 한국지반공학회논문집
    • /
    • 제28권12호
    • /
    • pp.111-122
    • /
    • 2012
  • 딜라토메터 시험과 동시에 탄성파 속도와 전기비저항 값을 도출할 수 있는 전기비저항 탄성파 Flat DMT 장비를 소개하였다. 탄성파 속도 측정 부분의 신뢰성을 높이기 위해서 자동 가진원, PC기반 신호 획득 장비 및 운영 프로그램의 개발을 통해 자동화 시스템을 구축하였다. 실제 전기비저항 측정을 위해서 전기비저항 측정 모듈의 거리계수를 실험적으로 도출하였다. 개발된 장비의 현장 검증 실험을 연약 지반 개량 공사가 진행될 부지에서 수행하였으며 비교를 위해 SPT, 피에조 콘, 벤더 엘리먼트 실험 및 지표면 전기비저항 탐사 등을 동시에 수행하였다. 개발된 장비를 통해서 한 번의 관입 실험으로 다양한 지반 정수의 도출이 가능하였으며 모든 측정 모듈에서 반복성 및 신뢰성을 확인함으로써 개발된 장비를 검증하고 적용성을 평가할 수 있었다.

평균년 표준기상데이터를 이용한 평판형 태양열 집열기 설치각 산정에 관한 연구 (A Study on the Setting Angle for the Flat-Plate Solar Collector' using Typical Meteorological Year Weather Data)

  • 최정민
    • 설비공학논문집
    • /
    • 제14권12호
    • /
    • pp.1084-1091
    • /
    • 2002
  • In general, flat-plate solar collectors are generally fixed in place at some angles. The most common method is to orient solar collectors toward the true south, where variations up to 15 degrees east or west are acceptable and the tiIt angle of the collectors is calculated from latitude and different heating applications. However, the best angle of flat-plate collectors depends upon whether the dominant load occurs in the winter, summer, or evenly all year. Moreover, this setting angle must consider the average insolation characteristics of the region exactly. In this study, the setting angle of flat-plate solar collectors is presented for Busan area by using domestic typical meteorological year weather data, so that the fixed flat-plate solar collectors must be set as quantitatively as possible.

Inversion-Based Robust Output Tracking of Differentially Flat Nonlinear Systems

  • Joo, Jin-Man;Park, in-Bae;Park, Yoon-Ho
    • Transactions on Control, Automation and Systems Engineering
    • /
    • 제3권1호
    • /
    • pp.21-26
    • /
    • 2001
  • In this study, we propose a two degree of freedom robust output tracking control method for a class of nonlinear system. We consider hyperbolically nonminimum phase single-input single-output uncertain nonlinear systems. We also consider the case that the nominal input-state equation is differentially flat. Nominal stable state trajectory is obtained in the flat output space via the flat output. Nominal feedforward control input is also computed from the nominal state trajectory. Due to the nature of the method, the generated flat output trajectory and control input are noncausal. Robust feedback control is designed to stabilize the systems around the nominal trajectory. A numerical example is given is given to demonstrate that robust tracking is achieved.

  • PDF

수직진동 사용성을 고려한 플랫 플레이트 슬래브의 최소두께 제안 (Minimum Thickness of Flat Plate Slab Satisfying Floor Vibration Criteria)

  • 이민정;김동현;한상환
    • 한국소음진동공학회논문집
    • /
    • 제16권6호
    • /
    • pp.574-581
    • /
    • 2006
  • Flat plate slab systems are more economical rather than reinforced concrete frame systems because flat plate slab system reduces story height. Furthermore flat plate systems are more popularly needed in construction practice due to flexibility of plan. Korean Concrete Provisions 2003 provide the minimum thickness of the slab that satisfies serviceability requirement to the static displacement. However, floor thickness in residence buildings may not satisfy the floor vibration criteria although the thickness satisfies the serviceability requirements in current design provisions. This study estimates the dynamic properties of floor vibration for existing flat plate slabs, and proposes the slab thickness satisfying the floor vibration criteria. The dynamic response analysis using finite element method and reliability analysis are carried out for this Purpose.

컴퓨터 시물레이션 에 의한 太陽熱 集熱器 의 最適設計 에 관한 硏究 (The Analysis of Optimum Design Parameters for a Flat-Plate solar Collector Through Computer Simulation)

  • 조수원;김종보
    • 대한기계학회논문집
    • /
    • 제8권1호
    • /
    • pp.1-9
    • /
    • 1984
  • In the utilization of solar energy most often a flat solar collector is used for solar heating, system. Since solar energy is absorbed through this solar collector, it is considered to be a most important part in the whole solar heating system. The purpose of the present investigation is to evaluate the influence of varying design parameters for thermal performances of flat-plate solar collector. By analysing these parameters, optimum design of solar collector would become possible. Specification of the existing solar collector are utilized in calculation as a starting point. Analysis is carried out numerically for "Unit Solar Collector" which is composed of fin and tube. Among design parameters. such parameters as mass flow rate per unit area, tube spacing and fin thickness are selected as variables in the computer simulation model. Results are presented for thermal performances of flat-plate solar collector for each important design parameters, so that predictions become possible through numerical analysis without performing experiments whenever it is required. required.

지속가능한 초고층 건물을 위한 80층 RC 플랫 플레이트 건물의 연쇄붕괴 저항성능 평가 (An Evaluation for Progressive Collapse Resisting Capacity of a 80F RC Flat Plate for Sustainable Super Tall Building)

  • 서대원;김해진;신성우
    • KIEAE Journal
    • /
    • 제10권5호
    • /
    • pp.151-157
    • /
    • 2010
  • This study is connected with evaluation of the progressive collapse resisting capacity for sustainable RC super tall building design. As the progressive collapse is not considered in current design codes in Korea, differences between linear static and dynamic analysis based on the GSA guidelines was analyzed for better evaluation, and the analysis model of flat plate system was determined. Finally, the progressive collapse resisting capacity was evaluated for structural system of super tall building. According to this study, the results by linear dynamic analysis were underestimated than the results by linear static analysis. Thus, the dynamic coefficient value of 2 provides conservative approach. The Effective Beam Width's model, currently used in field, is useful for the analysis about lateral force, but this model does not consider the effect of load redistribution by the slab. Hence, finite element analysis considering slab element will be needed for progressive collapse resisting capacity of the flat plate system. Finally, analysis model of 80-story building designed based on KBC(Korea Building Code) shows the weakness against progressive collapse because the DCR value is over 2. Thus, the countermeasure for alternative loading path such as installment of spandrel beam and reinforcements around slab is required to prevent the progressive collapse.

대면적 X-ray 검출기를 위한 분할 구동 시스템 (Seperate Driving System For Large Area X-ray Detector In Radiology)

  • 이동길;박지군;김대환;남상희;안상호;박효덕
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.388-391
    • /
    • 2003
  • The properties of these detectors can be controlled by electronics and exposure conditions. Flat-panel detectors for digital diagnostic imaging convert incident x-ray images to charge images. Flat panel detectors gain more interest real time medical x-ray imaging. Active area of flat panel detector is $14{\times}17$ inch. Detector is based on a $2560{\times}3072$ away of photoconductor and TFT pixels. X-ray conversion layer is deposited upper TFT array flat panel with a 500m by thermal deposition technology. Thickness uniformity of this layer is made of thickness control technology(5%) of thermal deposition system. Each $139m{\times}139m$ pixel is made of thin film transistor technology, a storage capacitor and charge collection electrode having geometrical fill factor of 86%. Using the separate driving system of two dimensional mosaic modules for large area, that is able to 4.2 second per frame. Imaging performance is suited for digital radiography imaging substitute by conventional radiography film system..

  • PDF